974 resultados para Vein-thrombosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The remarkable patency of internal mammary artery (MA) grafts compared to saphenous vein (SV) grafts has been related to different biological properties of the two blood vessels. We examined whether proliferation and apoptosis of vascular smooth muscle cells (VSMC) from human coronary artery bypass vessels differ according to patency rates. METHODS AND RESULTS: Proliferation rates to serum or platelet-derived growth factor (PDGF)-BB were lower in VSMC from MA than SV. Surface expression of PDGF beta-receptor was slightly lower, while that of alpha-receptor was slightly higher in MA than SV. Cell cycle distribution, expression of cyclin E, cdk2, p21, p27, p57, and cdk2 kinase activity were identical in PDGF-BB-stimulated cells from MA and SV. However, apoptosis rates were higher in MA than SV determined by lactate dehydrogenase release, DNA fragmentation, and Hoechst 33258 staining. Moreover, caspase inhibitors (Z-VAD-fmk, Boc-D-fmk) abrogated the different proliferation rates of VSMC from MA versus SV. Western blotting and GSK3-beta kinase assay revealed lower Akt activity in VSMC from MA versus SV, while total Akt expression was identical. Adenoviral transduction of a constitutively active Akt mutant abrogated the different proliferation rates of VSMC from MA versus SV. CONCLUSIONS: Higher apoptosis rates due to lower Akt activity rather than different cell cycle regulation account for the lower proliferation of VSMC from MA as compared to SV. VSMC apoptosis may protect MA from bypass graft disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the score for disseminated intravascular coagulation (DIC) recently published by the International Society for Thrombosis and Haemostasis (ISTH) in a well-defined series of sepsis patients. Thirty-two patients suffering from severe sepsis and eight patients with septic shock were evaluated following the ISTH DIC score. Fibrin monomer and D-dimer were chosen as fibrin-related markers (FRM), respectively. DIC scores for nonsurvivors (n = 13) as well as for septic shock patients were higher (P < 0.04) compared with survivors and patients with severe sepsis, respectively. Using fibrin monomer and D-dimer, 30 and 25% of patients suffered from overt DIC. Overt DIC was associated with significantly elevated thrombin-antithrombin complexes and plasminogen activator inhibitor type-1 levels as well as with significantly lower factor VII clotting activity. Patients with overt DIC had a significantly higher risk of death and of developing septic shock. Since more than 95% of the sepsis patients had elevated FRM, the DIC score was strongly dependent on prolongation of the prothrombin time and platelet counts. The ISTH DIC score is useful to identify patients with coagulation activation, predicting fatality and disease severity. It mainly depends on the prolongation of the prothrombin time and platelet counts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement into the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Autogenous iliac crest has long served as the gold standard for anterior lumbar arthrodesis although added morbidity results from the bone graft harvest. Therefore, femoral ring allograft, or cages, have been used to decrease the morbidity of iliac crest bone harvesting. More recently, an experimental study in the animal showed that harvesting local bone from the anterior vertebral body and replacing the void by a radio-opaque beta-tricalcium phosphate plug was a valid concept. However, such a concept precludes theoretically the use of posterior pedicle screw fixation. At one institution a consecutive series of 21 patients underwent single- or multiple-level circumferential lumbar fusion with anterior cages and posterior pedicle screws. All cages were filled with cancellous bone harvested from the adjacent vertebral body, and the vertebral body defect was filled with a beta-tricalcium phosphate plug. The indications for surgery were failed conservative treatment of a lumbar degenerative disc disease or spondylolisthesis. The purpose of this study, therefore, was to report on the surgical technique, operative feasibility, safety, benefits, and drawbacks of this technique with our primary clinical experience. An independent researcher reviewed all data that had been collected prospectively from the onset of the study. The average age of the patients was 39.9 (26-57) years. Bone grafts were successfully harvested from 28 vertebral bodies in all but one patient whose anterior procedure was aborted due to difficulty in freeing the left common iliac vein. This case was converted to a transforaminal interbody fusion (TLIF). There was no major vascular injury. Blood loss of the anterior procedure averaged 250 ml (50-350 ml). One tricalcium phosphate bone plug was broken during its insertion, and one endplate was broken because of wrong surgical technique, which did not affect the final outcome. One patient had a right lumbar plexopathy that was not related to this special technique. There was no retrograde ejaculation, infection or pseudoarthrosis. One patient experienced a deep venous thrombosis. At the last follow up (mean 28 months) all patients had a solid lumbar spine fusion. At the 6-month follow up, the pain as assessed on the visual analog scale (VAS) decreased from 6.9 to 4.5 (33% decrease), and the Oswestry disability index (ODI) reduced from 48.0 to 31.7 with a 34% reduction. However, at 2 years follow up there was a trend for increase in the ODI (35) and VAS (5). The data in this study suggest that harvesting a cylinder of autograft from the adjacent vertebral body is safe and efficient. Filling of the void defect with a beta-tricalcium phosphate plug does not preclude the use of posterior pedicle screw stabilization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Stent thrombosis is a safety concern associated with use of drug-eluting stents. Little is known about occurrence of stent thrombosis more than 1 year after implantation of such stents. METHODS: Between April, 2002, and Dec, 2005, 8146 patients underwent percutaneous coronary intervention with sirolimus-eluting stents (SES; n=3823) or paclitaxel-eluting stents (PES; n=4323) at two academic hospitals. We assessed data from this group to ascertain the incidence, time course, and correlates of stent thrombosis, and the differences between early (0-30 days) and late (>30 days) stent thrombosis and between SES and PES. FINDINGS: Angiographically documented stent thrombosis occurred in 152 patients (incidence density 1.3 per 100 person-years; cumulative incidence at 3 years 2.9%). Early stent thrombosis was noted in 91 (60%) patients, and late stent thrombosis in 61 (40%) patients. Late stent thrombosis occurred steadily at a constant rate of 0.6% per year up to 3 years after stent implantation. Incidence of early stent thrombosis was similar for SES (1.1%) and PES (1.3%), but late stent thrombosis was more frequent with PES (1.8%) than with SES (1.4%; p=0.031). At the time of stent thrombosis, dual antiplatelet therapy was being taken by 87% (early) and 23% (late) of patients (p<0.0001). Independent predictors of overall stent thrombosis were acute coronary syndrome at presentation (hazard ratio 2.28, 95% CI 1.29-4.03) and diabetes (2.03, 1.07-3.83). INTERPRETATION: Late stent thrombosis was encountered steadily with no evidence of diminution up to 3 years of follow-up. Early and late stent thrombosis were observed with SES and with PES. Acute coronary syndrome at presentation and diabetes were independent predictors of stent thrombosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Stent thrombosis may occur late after drug-eluting stent (DES) implantation, and its cause remains unknown. The present study investigated differences of the stented segment between patients with and without very late stent thrombosis with the use of intravascular ultrasound. METHODS AND RESULTS: Since January 2004, patients presenting with very late stent thrombosis (> 1 year) after DES implantation underwent intravascular ultrasound. Findings in patients with very late stent thrombosis were compared with intravascular ultrasound routinely obtained 8 months after DES implantation in 144 control patients, who did not experience stent thrombosis for > or = 2 years. Very late stent thrombosis was encountered in 13 patients at a mean of 630+/-166 days after DES implantation. Compared with DES controls, patients with very late stent thrombosis had longer lesions (23.9+/-16.0 versus 13.3+/-7.9 mm; P<0.001) and stents (34.6+/-22.4 versus 18.6+/-9.5 mm; P<0.001), more stents per lesion (1.6+/-0.9 versus 1.1+/-0.4; P<0.001), and stent overlap (39% versus 8%; P<0.001). Vessel cross-sectional area was similar for the reference segment (cross-sectional area of the external elastic membrane: 18.9+/-6.9 versus 20.4+/-7.2 mm2; P=0.46) but significantly larger for the in-stent segment (28.6+/-11.9 versus 20.1+/-6.7 mm2; P=0.03) in very late stent thrombosis patients compared with DES controls. Incomplete stent apposition was more frequent (77% versus 12%; P<0.001) and maximal incomplete stent apposition area was larger (8.3+/-7.5 versus 4.0+/-3.8 mm2; P=0.03) in patients with very late stent thrombosis compared with controls. CONCLUSIONS: Incomplete stent apposition is highly prevalent in patients with very late stent thrombosis after DES implantation, suggesting a role in the pathogenesis of this adverse event.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although rare, stent thrombosis remains a severe complication after stent implantation owing to its high morbidity and mortality. Since the introduction of drug-eluting stents (DES), most interventional centers have noted stent thrombosis up to 3 years after implantation, a complication rarely seen with bare-metal stents. Some data from large registries and meta-analyses of randomized trials indicate a higher risk for DES thrombosis, whereas others suggest an absence of such a risk. Several factors are associated with an increased risk of stent thrombosis, including the procedure itself (stent malapposition and/or underexpansion, number of implanted stents, stent length, persistent slow coronary blood flow, and dissections), patient and lesion characteristics, stent design, and premature cessation of antiplatelet drugs. Drugs released from DES exert distinct biological effects, such as activation of signal transduction pathways and inhibition of cell proliferation. As a result, although primarily aimed at preventing vascular smooth muscle cell proliferation and migration (ie, key factors in the development of restenosis), they also impair reendothelialization, which leads to delayed arterial healing, and induce tissue factor expression, which results in a prothrombogenic environment. In the same way, polymers used to load these drugs have been associated with DES thrombosis. Finally, DES impair endothelial function of the coronary artery distal to the stent, which potentially promotes the risk of ischemia and coronary occlusion. Although several reports raise the possibility of a substantially higher risk of stent thrombosis in DES, evidence remains inconclusive; as a consequence, both large-scale and long-term clinical trials, as well as further mechanistic studies, are needed. The present review focuses on the pathophysiological mechanisms and pathological findings of stent thrombosis in DES.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a case of combined central retinal vein and cilioretinal artery occlusion which, due to the absence of the temporal branch retinal artery, was initially misdiagnosed as a combined central retinal vein occlusion and temporal branch retinal artery occlusion. Given that - in contrast to cases of combined central artery and central retinal vein occlusion - the prognosis for cilioretinal artery occlusion with central retinal vein occlusion is quite good, this case illustrates the importance of suspecting an unusual condition in the presence of a combined occlusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This study aimed to evaluate the safety and patency rate of bovine mesenterial vein grafts (BMVG) for vascular access (VA) in hemodialysis patients (HDP), compared to expanded polytetrafluorethylene (ePTFE grafts) over a mid- to long-term period. METHODS: Patency and complication rate of 23 consecutive HDP with BMVG for VA were compared to a control group consisting of 23 similar HDP with ePTFE grafts. In both groups, the graft was placed preferably in a forearm loop configuration. The same surgeon performed all procedures. All patients were followed over a period of 4 yrs. RESULTS: Graft placement was successful in all patients. Patency rates did not differ significantly in both groups. However, there were less severe complications in the BMVG group. CONCLUSION: The BMVG is a viable alternative for HD access in patients where autologous construction is not possible, and should be given priority in patients with a failed ePTFE graft or high risk for infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cryopreserved human blood vessels are important tools in reconstructive surgery. However, patency of frozen/thawed conduits depends largely on the freezing/thawing procedures employed. METHODS: Changes in tone were recorded on rings from human saphenous vein (SV) and used to quantify the degree of cryoinjury after different periods of exposure at room temperature to the cryomedium (Krebs-Henseleit solution containing 1.8M dimethyl sulfoxide and 0.1M sucrose) and after different cooling speeds and thawing rates following storage at -196 degrees C. RESULTS: Without freezing, exposure of SV to the cryomedium for up to 240 min did not modify contractile responses to noradrenaline (NA). Pre-freezing exposure to the cryomedium for 10-120 min attenuated significantly post-thaw maximal contractile responses to NA, endothelin-1 (ET-1) and potassium chloride (KCl) by 30-44%. Exposure for 240 min attenuated post-thaw contractile responses to all tested agents markedly by 62-67%. Optimal post-thaw contractile activity was obtained with SV frozen at about -1.2 degrees C/min and thawed slowly at about 15 degrees C/min. In these SV maximal contractile responses to NA, ET-1 and KCl amounted to 66%, 70% and 60% of that produced by unfrozen controls. Following cryostorage of veins for up to 10 years the responsiveness of vascular smooth muscle to NA was well maintained. CONCLUSION: Cryopreservation allows long-term banking of viable human SV with only minor loss in contractility.