974 resultados para VT ablation
Resumo:
Objective: The purpose of this study was to assess the efficacy of Er:YAG laser energy for composite resin removal and the influence of pulse repetition rate on the thermal alterations occurring during laser ablation. Materials and Methods: Composite resin filling was placed in cavities (1.0 mm deep) prepared in bovine teeth and the specimens were randomly assigned to five groups according to the technique used for composite filling removal. In group I (controls), the restorations were removed using a high-speed diamond bur. In the other groups, the composite fillings were removed using an Er: YAG laser with different pulse repetition rates: group 2-2 Hz; group 3-4 Hz; group 4-6 Hz; and group 5-10 Hz. The time required for complete removal of the restorative material and the temperature changes were recorded. Results: Temperature rise during composite resin removal with the Er: YAG laser occurred in the substrate underneath the restoration and was directly proportional to the increase in pulse repetition rate. None of the groups had a temperature increase during composite filling removal of more than 5.6 degrees C, which is considered the critical point above which irreversible thermal damage to the pulp may result. Regarding the time for composite filling removal, all the laser-ablated groups (except for group 5 [10 Hz]) required more time than the control group for complete elimination of the material from the cavity walls. Conclusion: Under the tested conditions, Er: YAG laser irradiation was efficient for composite resin ablation and did not cause a temperature increase above the limit considered safe for the pulp. Among the tested pulse repetition rates, 6 Hz produced minimal temperature change compared to the control group (high-speed bur), and allowed composite filling removal within a time period that is acceptable for clinical conditions.
Resumo:
Objective: The aim of this study was to assess by atomic force microscopy (AFM) the effect of Er,Cr:YSGG laser application on the surface microtopography of radicular dentin. Background: Lasers have been used for various purposes in dentistry, where they are clinically effective when used in an appropriate manner. The Er, Cr: YSGG laser can be used for caries prevention when settings are below the ablation threshold. Materials and Methods: Four specimens of bovine dentin were irradiated using an Er, Cr:YSGG laser (lambda = 2.78 mu m), at a repetition rate of 20 Hz, with a 750-mu m-diameter sapphire tip and energy density of 2.8 J/cm(2) (12.5 mJ/pulse). After irradiation, surface topography was analyzed by AFM using a Si probe in tapping mode. Quantitative and qualitative information concerning the arithmetic average roughness (Ra) and power spectral density analyses were obtained from central, intermediate, and peripheral areas of laser pulses and compared with data from nonirradiated samples. Results: Dentin Ra for different areas were as follows: central, 261.26 (+/- 21.65) nm; intermediate, 83.48 (+/- 6.34) nm; peripheral, 45.8 (+/- 13.47) nm; and nonirradiated, 35.18 (+/- 2.9) nm. The central region of laser pulses presented higher ablation of intertubular dentin, with about 340-760 nm height, while intermediate, peripheral, and nonirradiated regions presented no difference in height of peritubular and interperitubular dentin. Conclusion: According to these results, we can assume that even when used at a low-energy density parameter, Er, Cr: YSGG laser can significantly alter the microtopography of radicular dentin, which is an important characteristic to be considered when laser is used for clinical applications.
Resumo:
It has been demonstrated that laser induced breakdown spectrometry (LIBS) can be used as an alternative method for the determination of macro (P, K. Ca, Mg) and micronutrients (B, Fe, Cu, Mn, Zn) in pellets of plant materials. However, information is required regarding the sample preparation for plant analysis by LIBS. In this work, methods involving cryogenic grinding and planetary ball milling were evaluated for leaves comminution before pellets preparation. The particle sizes were associated to chemical sample properties such as fiber and cellulose contents, as well as to pellets porosity and density. The pellets were ablated at 30 different sites by applying 25 laser pulses per site (Nd:YAG@1064 nm, 5 ns, 10 Hz, 25J cm(-2)). The plasma emission collected by lenses was directed through an optical fiber towards a high resolution echelle spectrometer equipped with an ICCD. Delay time and integration time gate were fixed at 2.0 and 4.5 mu s, respectively. Experiments carried out with pellets of sugarcane, orange tree and soy leaves showed a significant effect of the plant species for choosing the most appropriate grinding conditions. By using ball milling with agate materials, 20 min grinding for orange tree and soy, and 60 min for sugarcane leaves led to particle size distributions generally lower than 75 mu m. Cryogenic grinding yielded similar particle size distributions after 10 min for orange tree, 20 min for soy and 30 min for sugarcane leaves. There was up to 50% emission signal enhancement on LIBS measurements for most elements by improving particle size distribution and consequently the pellet porosity. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Laser induced breakdown spectroscopy (LIBS) has been evaluated for the determination of micronutrients (B, Cu, Fe, Mn and Zn) in pellets of plant materials, using NIST, BCR and GBW biological certified reference materials for analytical calibration. Pellets of approximately 2 mm thick and 15 mm diameter were prepared by transferring 0.5 g of powdered material to a 15 mm die set and applying 8.0 tons cm(-2). An experimental setup was designed by using a Nd:YAG laser operating at 1064 nm (200 mJ per pulse, 10 Hz) and an Echelle spectrometer with ICCD detector. Repeatability precision varied from 4 to 30% from measurements obtained in 10 different positions (8 laser shots per test portion) in the same sample pellet. Limits of detection were appropriate for routine analysis of plant materials and were 2.2 mg kg(-1) B, 3.0 mg kg(-1) Cu, 3.6 mg kg(-1) Fe, 1.8 mg kg(-1) Mn and 1.2 mg kg(-1) Zn. Analysis of different plant samples were carried out by LIBS and results were compared with those obtained by ICP OES after wet acid decomposition. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Surface heat treatment in glasses and ceramics, using CO(2) lasers, has attracted the attention of several researchers around the world due to its impact in technological applications, such as lab-on-a-chip devices, diffraction gratings and microlenses. Microlens fabrication on a glass surface has been studied mainly due to its importance in optical devices (fiber coupling, CCD signal enhancement, etc). The goal of this work is to present a systematic study of the conditions for microlens fabrications, along with the viability of using microlens arrays, recorded on the glass surface, as bidimensional codes for product identification. This would allow the production of codes without any residues (like the fine powder generated by laser ablation) and resistance to an aggressive environment, such as sterilization processes. The microlens arrays were fabricated using a continuous wave CO(2) laser, focused on the surface of flat commercial soda-lime silicate glass substrates. The fabrication conditions were studied based on laser power, heating time and microlens profiles. A He-Ne laser was used as a light source in a qualitative experiment to test the viability of using the microlenses as bidimensional codes.
Resumo:
Aims To verify whether spectral components of atrial electrograms (AE) during sinus rhythm (SR) correlate with cardiac ganglionated plexus (GP) sites. Methods and results Thirteen patients undergoing atrial fibrillation (AF) ablation were prospectively enrolled. Prior to radio frequency application, endocardial AE were recorded with a sequential point-by-point approach. Electrical stimuli were delivered at 20 Hz, amplitude 100 V, and pulse width of 4 ms. A vagal response was defined as a high-frequency stimulation (HFS) evoked atrioventricular block or a prolongation of RR interval. Spectral analysis was performed on single AE during SR, sampling rate of 1000 Hz, Hanning window. Overall, 1488 SR electrograms were analysed from 186 different left atrium sites, 129 of them corresponding to negative vagal response sites, and 57 to positive response sites. The electrogram duration and the number of deflections were similar in positive and negative response sites. Spectral power density of sites with vagal response was lower between 26 and 83 Hz and higher between 107 and 200 Hz compared with negative response sites. The area between 120 and 170 Hz normalized to the total spectrum area was tested as a diagnostic parameter. Receiver operating characteristic curve analysis demonstrated that an area120-170/area(total) value >0.14 identified vagal sites with 70.9% sensitivity and 72.1% specificity. Conclusion Spectral analysis of AE during SR in sites that correspond to the anatomical location of the GP is feasible and may be a simpler method of mapping the cardiac autonomic nervous system, compared with the HFS technique.
Resumo:
The purposes of this study were to evaluate in vitro the influence of different frequencies of Er:YAG laser on the human dentin caries removal capacity. Thirty fragments obtained from third molars were randomly assigned into three groups (n = 10) according to the laser frequency used: 4, 6, and 10 Hz. The caries lesion (+/-1 mm deep) was induced before the irradiation by S. mutans cultures for 6 weeks. The specimens of all groups were irradiated with 200 mJ of energy in noncontact and focused mode under constant refrigeration (water flow: 2.5 mL/min). Quantitative analysis of the caries removal was performed by DIAGNOdent (TM) and the Axion Vision (TM) software. Qualitative analysis was performed by Scanning electron microscope (SEM) and light microscope (LM). Data were analyzed by ANOVA and Fishers` tests. The DIAGNOdent (TM) revealed that the caries removal was similar with 4 and 6 Hz and was superior with 10 Hz (P < 0.05). The analysis with Axion Vision (TM) software revealed that the caries removal was similar with 6 and 10 Hz and the 4 Hz group promoted the lowest caries removal. Through SEM morphologic analysis, some specimens irradiated with 4 Hz presented, under the demineralized dentin, a disorganized collagenous matrix. The LM images revealed that all frequencies used promoted irregular caries removal, being observed over preparations with 6 and 10 Hz. It can be concluded that the increase of Er:YAG laser frequency provided a higher dentin caries removal without selectivity to the disorganized dentin. Microsc. Res. Tech. 74:281-286, 2011. (C) 2010 Wiley-Liss, Inc.
Resumo:
The incidence and progression of disorders associated with an unbalanced immune response has among many factors the gender as a contributory factor. The aims of this work were to evaluate the effects of orchiectomy and the immune response during the experimental Trypanosoma cruzi infection. Young adult, male Calomys callous were i.p. inoculated with 1 x 10(5) blood trypomastigotes of the CM strain of T. cruzi and divided in groups: Control, Sham and Castrated. Castrated group displayed significantly lower values for prostate and seminal vesicle weights indicating a drastic drop of testosterone plasmatic levels. Orchiectomized animals also displayed lesser number of blood parasites, enhanced lytic antibody percentage, splenocyte proliferation and NO concentration when compared to its sham and control counterparts, indicating that steroid gonadal ablation actually influences immune response triggering a more efficient cellular and humoral response which led animals to become more resistant against T cruzi infection. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
The hepatic disposition and metabolite kinetics of a homologous series of diflunisal O-acyl esters (acetyl, butanoyl, pentanoyl, anti hexanoyl) were determined using a single-pass perfused in situ rat liver preparation. The experiments were conducted using 2% BSA Krebs-Henseleit buffer (pH 7.4), and perfusions were performed at 30 mL/min in each liver. O-Acyl esters of diflunisal and pregenerated diflunisal were injected separately into the portal vein. The venous outflow samples containing the esters and metabolite diflunisal were analyzed by high performance liquid chromatography (HPLC). The normalized outflow concentration-time profiles for each parent ester and the formed metabolite, diflunisal, were analyzed using statistical moments analysis and the two-compartment dispersion model. Data (presented as mean +/- standard error for triplicate experiments) was compared using ANOVA repeated measures, significance level P < 0.05. The hepatic availability (AUC'), the fraction of the injected dose recovered in the outflowing perfusate, for O-acetyldiflunisal (C2D = 0.21 +/- 0.03) was significantly lower than the other esters (0.34-0.38). However, R-N/f(u), the removal efficiency number R-N divided by the unbound fraction in perfusate f(u), which represents the removal efficiency of unbound ester by the liver, was significantly higher for the most lipophilic ester (O-hexanoyldiflunisal, C6D = 16.50 +/- 0.22) compared to the other members of the series (9.57 to 11.17). The most lipophilic ester, C6D, had the largest permeability surface area (PS) product (94.52 +/- 38.20 mt min-l g-l liver) and tissue distribution value VT (35.62 +/- 11.33 mL g(-1) liver) in this series. The MTT of these O-acyl esters of diflunisal were not significantly different from one another. However, the metabolite diflunisal MTTs tended to increase with the increase in the parent ester lipophilicity (11.41 +/- 2.19 s for C2D to 38.63 +/- 9.81 s for C6D). The two-compartment dispersion model equations adequately described the outflow profiles for the parent esters and the metabolite diflunisal formed from the O-acyl esters of diflunisal in the liver.
Resumo:
BACKGROUND. Prostate secretory granules (PSG) represent the basic secretory unit of the prostate gland, containing many of its exocrine proteases. Recent analysis of intraluminal corpora amylacea, a proposed by-product of PSG secretion, detected sulfated glycosaminoglycans (GAG) possibly keratan sulfate (KS),indicating a secretory mechanism for GAG in the human prostate surface epithelial cell. METHODS. Immunostains using anti-KS and anti-prostate-specific antigen (PSA) were evaluated on 10 sequential radical prostatectomy specimens, three of which had received neoadjuvant antiandrogen therapy. Extracts of normal secretory tissue as well as a sample composed almost entirely of prostatic stroma were subjected to Western blot analysis, using the same antibody panel. RESULTS. Keratan sulfate secretion from the normal prostate epithelial cell has been confirmed and correlates, as does PSA, with the presence of cytoplasmic PSG. No such correlation exists in most adenocarcinomas or in benign epithelium after androgen ablation. Western blot analyses confirmed tissue immunostains and demonstrated a secretory proteoglycan of 70-95 kDa. CONCLUSIONS. Recognition of PSG heralds a novel secretory mechanism within the human prostate gland that is linked to the secretion of KS. The role of KS in normal prostate secretion remains unknown, although it appears downregulated in neoplastic and androgen-ablated cells. (C) 2000 Wiley-Liss, Inc.
Resumo:
Associations between self-reported 'low iron', general health and well-being, vitality and tiredness in women, were examined using physical (PCS) and mental (MCS) component summary and vitality (VT) scores from the MOS short-form survey (SF-36). 14,762 young (18-23 years) and 14,072 mid-age (45-50 years) women, randomly selected from the national health insurance commission (Medicare) database, completed a baseline mailed self-report questionnaire and 12,328 mid-age women completed a follow-up questionnaire 2 years later. Young and mid-age women who reported (ever) having had 'low iron' reported significantly lower mean PCS, MCS and VT scores, and greater prevalence of 'constant tiredness' at baseline than women with no history of iron deficiency [Differences: young PCS = -2.2, MCS = -4.8, VT = -8.7; constant tiredness: 67% vs. 45%; mid-age PCS = -1.4, MCS = -3.1, VT = -5.9; constant tiredness: 63% vs. 48%]. After adjusting for number of children, chronic conditions, symptoms and socio-demographic variables, mean PCS, MCS and VT scores for mid-age women at follow-up were significantly lower for women who reported recent iron deficiency (in the last 2 years) than for women who reported past iron deficiency or no history of iron deficiency [Means: PCS - recent = 46.6, past = 47.8, never = 47.7; MCS - recent = 45.4, past = 46.9, never = 47.4; VT - recent = 54.8, past = 57.6, never = 58.6]. The adjusted mean change in PCS, MCS and VT scores between baseline and follow-up were also significantly lower among mid-age women who reported iron deficiency only in the last 2 years (i.e. recent iron deficiency) [Mean change: PCS = -3.2; MCS = -2.1; VT = -4.2]. The results suggest that iron deficiency is associated with decreased general health and well-being and increased fatigue.
Resumo:
The purpose of this in vitro study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine previously treated with Er:YAG laser. Twenty caries free extracted human third molars were used. The teeth were divided in four experimental groups (n = 5): (G1) control group; (G2) irradiation of the adhesive system with the Nd:YAG laser; (G3) dentin treatment with Er:YAG laser; (G4) dentin treatment with Er:YAG laser followed by the irradiation of the adhesive system with Nd:YAG laser. The Er:YAG laser fluency parameter for the dentin treatment was of 60 J/cm(2). ne adhesive system was irradiated with the Nd:YAG laser with fluency of 100 J/cm(2). Dental restorations were performed with Adper Single Bond 2/Z250. One tooth from each group was prepared for the evaluation of the adhesive interface under SEM and bond failure tests were also performed and evaluated. The statistical analysis showed statistical significant difference between the groups G1 and G3, G1 and G4, G2 and G3, and G2 and G4; and similarity between the groups G1 and G2, and G3 and G4. The adhesive failures were predominant in all the experimental groups. The SEM analysis showed an adhesive interface with features confirming the results of the mechanical tests. The Nd:YAG laser on the adhesive system did not influence the bond strength in dentin treated or not with the Er:YAG laser.
Resumo:
Background: Over-ventilation causing low arterial carbon dioxide levels (PaCO2) has been associated with the development of neonatal chronic lung disease and adverse outcomes. This may occur very soon after birth. Aim: To investigate the effect on PaCO2 and oxygenation of very premature lambs resuscitated with different tidal volumes and PEEP. Methods: Anaesthetised lambs delivered at 126 days gestation were randomised to 15 min resuscitation with 3 regimes: (1) Laerdal resuscitation bag (B) with 100% oxygen and no PEEP, (2) fixed tidal volume (VT) of 5 mL/kg, or (3) VT of 10 mL/kg, both delivered with a Babylog 8000 ventilator in volume guarantee mode with 8 cm H2O PEEP and variable FiO2. Frequent blood gases were measured and VT, mean airway pressure (Paw), minute volume (MV), ventilation rate (VR), respiratory system compliance (Crs) and alveolar/arterial oxygen difference (AaDO2) were recorded. Results: Twenty lambs were studied. B (1) was associated with more variable VT and peak inspiratory pressures (PIP) compared to fixed tidal volumes (2 and 3). The lambs ventilated with 10 mL/kg were over-ventilated, those ventilated with 5 mL/kg were slightly under-ventilated. Those ventilated with the Laerdal bag had a mean VT of 7.5 mL/kg and were normocarbic. The different tidal volumes had little effect on oxygenation. PEEP improved oxygenation. The table shows the values at 15 minutes expressed as mean and SEM. TABLE. No caption av... TABLE. No caption av... Image Tools Conclusion: Very premature lambs can be effectively resuscitated from birth using volume guarantee ventilation. Within minutes of birth different tidal volumes had a large effect on PaCO2 and no effect on oxygenation. Studies are needed to determine the appropriate tidal volume for resuscitating very premature infants to maintain acceptable levels of PaCO2. © International Pediatrics Research Foundation, Inc. 2004. All Rights Reserved.
Resumo:
PURPOSE: To compare changes in corneal hysteresis (CH) and the corneal resistance factor (CRF) in myopic and hyperopic laser in situ keratomileusis (LASIK) and evaluate their relationship to the number of photoablative pulses delivered, a surrogate for ablation volume. SETTING: Cleveland Clinic Cole Eye Institute, Cleveland, Ohio, USA. METHODS: Preoperative and 1-week postoperative Ocular Response Analyzer measurements in eyes that had femtosecond-assisted LASIK were studied retrospectively. Changes in CH and CRF were compared and tested for correlation with the number of excimer laser pulses. RESULTS: Thirteen myopic eyes and 11 hyperopic eyes were evaluated. Preoperative corneal thickness, CH, CRF, programmed correction magnitude, flap thickness, and total number of fixed spotsize photoablative pulses were similar in the 2 groups (P>.1). Decreases in CH and CRF were greater after myopic LASIK than after hyperopic LASIK (P<.005), and changes in CRF were correlated with the number of excimer laser pulses in the myopic group only (r = -0.63, P = .02). Regardless of ablation profile, changes in CH were more strongly correlated with preoperative CH values than with attempted ablation volume. CONCLUSIONS: With comparable flap thickness and attempted ablation volumes, myopic photoablation profiles were associated with greater decreases in CRF and CH than hyperopic profiles. Results indicate that preoperative corneal biomechanical status, ablation volume, and the spatial distribution of ablation are important factors that affect corneal resistance and viscous dissipative properties differently. Preferential tissue removal in the natively thicker paracentral cornea in hyperopia may partially account for the rarity of ectasia after hyperopic LASIK.