895 resultados para Urinary retention


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vaginal weight cone (VWC) versus assisted pelvic floor muscle training (APFMT) in the treatment of urinary incontinence (UI) in women.One hundred three incontinent women were randomly distributed into two groups: group G1 (n = 51) treated with VWC and G2 (n = 52), APFMT. The following parameters were performed initially and after treatment: (1) clinical questionnaire, (2) visual analogue scale (VAS), (3) 60-min pad test, and (4) subjective and objective assessment of pelvic floor muscle (PFM).There was a significant decrease in nocturia and urine loss after treatment in both groups (p < 0.05). In VAS, there was a significant improvement of all parameters in both groups (p < 0.05). The pad test showed significant decrease in both groups (p < 0.05). There was a significant increase of PFM strength in both groups (p < 0.05).There was no difference between groups treated with VWC and APFMT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PUSPOSE: To evaluate food intake of patients with urinary lithiasis and idiopathic hypercalciuria (IH). MATERIALS and METHODS: Between August 2007 and June 2008, 105 patients with lithiasis were distributed into 2 groups: Group 1 (n = 55) - patients with IH (urinary calcium excretion > 250 mg in women and 300 mg in men with normal serum calcium); Group 2 (n = 50) - normocalciuria (NC) patients . Inclusion criteria were: age over 18, normal renal function (creatinine clearance = 60 mL/min), absent proteinuria and negative urinary culture. Pregnant women, patients with some intestinal pathology, chronic diarrhea or using corticoids were excluded. The protocol of metabolic investigation was based on non-consecutive collection of two 24-hour samples for dosages of: calcium, sodium, uric acid, citrate, oxalate, magnesium and urinary volume. Food intake was evaluated through the quantitative method of Dietary Register of three days. RESULTS: Urinary excretion of calcium (433.33 ± 141.92 vs. 188.93 ± 53.09), sodium (280.08 ± 100.94 vs. 200.44.93 ± 65.81), uric acid (880.63 ± 281.50 vs. 646.74 ± 182.76) and magnesium (88.78 ± 37.53 vs. 64.34 ± 31.84) was significantly higher in the IH group in comparison to the NC group (p < 0.05). As regards the nutritional composition of food intake of IH and NC groups, there was no statistical significant difference in any nutrient evaluated. CONCLUSION: In our study, no difference was observed in the food intake of patients with urinary lithiasis and IH or NC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the prevalence of virulence genes in 158 Escherichia coli strains isolated from 51 clinical cases of UTIs, 52 of pyometra and from 55 fecal samples from healthy dogs by PCR. papC was found in 12 (23.5%) strains isolated from UTIs, 19 (36.5%) from pyometra and 10 (18.2%) from feces. papGII was observed in 3 (5.8%) strains from pyometra, and papGIII in 10 (19.6%) from UTIs, 15 (28.8%) from pyometra and 9 (16.4%) from feces. sfaS was detected in 22 (43.1%) strains from UTIs, 24 (46.1%) from pyometra and 19 (34.5%) from feces. hlyA was observed in 17 (33.3%) strains from UTIs, 18 (34.6%) from pyometra and 7 (12.7%) from feces, while cnf-1 was detected in 11 (21.6%) from UTIs, 21 (40.4%) from pyometra and 9 (16.4%) from feces. iucD was observed in 12 (23.5%) strains from UTIs, 9 (17.3%) from pyometra and 1 (1.8%) from feces. usp was found 17 (33.3%) isolates from UTIs and 36 (69.9%) from pyometra. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relata-se neste artigo o caso de tétano em um gato macho de 3 anos 8 dias após a realização de orquiectomia bilateral, onde o histórico do animal associado aos achados clínicos e laboratoriais propiciaram a definição do diagnóstico. Mesmo após tratamento, o quadro evoluiu para tetania generalizada e óbito. Neste caso, a ação da neurotoxina na musculatura estriada esquelética do esfíncter uretral foi um fator agravante para a doença, levando à retenção vesical e azotemia pós-renal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cárie secundária representa problema de saúde pública e socioeconômico no mundo. A restauração de dentes acometidos por cárie pode criar condições favoráveis à proliferação microbiana na superfície do material restaurador ou na interface dente/restauração, criando ambiente propício para o estabelecimento de cárie secundária. O objetivo deste estudo foi avaliar a capacidade de retenção de placa bacteriana em cimentos de ionômero de vidro convencionais (Chelon-Fil e Vidrion R) e modificados por resina (Vitremer e Fuji II LC) e de resina composta híbrida (Z100), utilizada como controle. Nos testes de retenção de microrganismos, in situ, 12 voluntários utilizaram, por 7 dias, placa de Hawley contendo corpos-de-prova de todos os materiais. A seguir, os corpos-de-prova foram transferidos para tubos contendo 2,0 ml de Ringer-PRAS e os microrganismos presentes em sua superfície foram cultivados em placa com ágar-sangue e ágar Mitis Salivarius Bacitracina, os quais foram incubados, a 37ºC, em anaerobiose (90% N2, 10% CO2), por 10 e 2 dias, respectivamente. Os ionômeros modificados por resina retiveram quantidade de bactérias similar àquela mostrada pela resina testada. Os ionômeros modificados por resina também apresentaram menor número de estreptococos do grupo mutans do que a resina e os cimentos ionoméricos convencionais. Os ionômeros de vidro convencionais apresentaram menor número de estreptococos do grupo mutans que a resina, sendo que essa diferença não foi estatisticamente significativa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the behavior and stress distribution of 3 retention systems associated with implant for facial prosthesis by using the photoelasticity method. A photoelastic model was made from the replica of the orbital region on the left side of a dry skull with two 4-mm implants fixed in the superior orbital region. Three facial prosthetic retention systems were made for this study: O'ring, bar-clip, and magnets. The set (model/retention systems/prosthesis) was placed in a polariscope, and then traction began to be applied to the retention systems. The limit values for removal of the retention system were obtained by tests performed in an EMIC Universal test machine. The results were obtained by observation during the experiments and by photographic record of the stress behavior in the photoelastic model, resulting from the traction of the retention systems. In the magnet system, a lowest formation of fringes was verified both around and between the implants; in the O'ring system, the formation of photoelastic fringes was noted between the implants in the apical region; and in the bar-clip system, there was a greater concentration of colored fringes in the regions between the implants and cervical area. Based on the results obtained, it was concluded that the retention systems produced different stress distribution characteristics that, in general, were concentrated in the area around the implants, and the highest concentration of fringes, in increasing order, occurred ill the retention systems of the magnets, O'ring, and bar-clip.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osseointegrated implants in craniofacial reconstructions improve prostheses retention and stability and comfort and safety for a patient. According to biomechanical principles, the treatment success regarding osseointegration maintenance depends on an adequate surgical technique associated to a retention system that provides favorable tension distribution to implants. Furthermore, patient expectation, esthetics, function, and anatomic limitations must be evaluated during treatment planning. Therefore, the aims of this study were to present available retention systems to implant-supported craniofacial prosthesis and to highlight the advantages, indications, and limitations. A literature review was conducted through a MEDLINE search. Sixteen articles and 2 textbooks met the inclusion criteria and were included in the review. It was concluded that the success of craniofacial rehabilitation with implants depends on an adequate surgical technique and an adequate selection of a retention system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Surgical reconstruction and prosthetic obturation are alternatives for the treatment of cleft in the soft palate.Design: The present case reports the rehabilitation of a patient presenting cleft palate with obturator prosthesis associated with implant-supported retention system.Conclusions: The use of ball attachment system improved speech, masticatory efficiency, swallowing, and social behavior of the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant-supported prostheses.Materials and Methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n = 12). The crowns presented no misfit in group A (control group) and unilateral misfits of 50 mu m, 100 mu m, and 200 mu m in groups B, C, and D, respectively. The crowns were screwed to external hexagon implants with titanium retention screws (torque of 30 N/cm), and the sets were submitted to three different periods of mechanical cycling: 2 x 10(4), 5 x 10(4), and 1 x 10(6) cycles. Screw microhardness values were measured before and after each cycling period. Data were evaluated by two-way ANOVA and Tukey's test (p < 0.05).Results: Mechanical cycling statistically reduced microhardness values of retention screws regardless of cycling periods and groups. In groups A, B, and C, initial microhardness values were statistically different from final microhardness values (p < 0.05). There was no statistically significant difference for initial screw microhardness values (p > 0.05) among the groups; however, when the groups were compared after mechanical cycling, a statistically significant difference was observed between groups B and D (p < 0.05).Conclusions: Mechanical cycling reduced the Vicker's microhardness values of the retention screws of all groups. The crowns with the highest misfit level presented the highest Vicker's microhardness values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the biomechanical behavior of a mandibular distal extension removable partial denture (DERPD) associated with an implant and different retention system, by bidimensional finite element method. Five hemimandible models with a canine and external hexagon implant at second molar region associated with DERPD were simulated: model A, hemimandible with a canine and a DERPD; model B, hemimandible with a canine and implant with a healing abutment associated to a DERPD; model C, hemimandible with a canine and implant with an ERA attachment associated to a DERPD; model D, hemimandible with a canine and implant with an O'ring attachment associated to a DERPD; and model E, hemimandible with a canine and implant-supported prosthesis associated to a DERPD. Cusp tips were loaded with 50 N of axial or oblique force (45 degrees). Finite element analysis was performed in ANSYS 9.0. model E showed the higher displacement and overload in the supporting tissues; the patterns of stress distribution around the dental apex of models B, C, and D were similar. The association between a DERPD and an osseointegrated implant using the ERA or O'ring systems shows lower stress values. Oblique forces showed higher stress values and displacement. Oblique forces increased the displacement and stress levels in all models; model C displayed the best stress distribution in the supporting structures; healing abutment, ERA, and O'ring systems were viable with RPD, but DERPD association with a single implant-supported prosthesis was nonviable.