977 resultados para Uniform Surface Heat Flux


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Física - IGCE

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: The thermal entry region in laminar forced convection of Herschel-Bulkley fluids is solved analytically through the integral transform technique, for both circular and parallel-plates ducts, which are maintained at a prescribed wall temperature or at a prescribed wall heat flux. The local Nusselt numbers are obtained with high accuracy in both developing and fully-developed thermal regions, and critical comparisons with previously reported numerical results are performed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As variações da temperatura e do fluxo de calor em solos sob a floresta nativa de Caxiuanã e uma pastagem natural da Ilha do Marajó, foram monitoradas continuamente no período de dezembro de 2001 a fevereiro de 2005. O objetivo foi comparar as respostas térmicas ao aquecimento diário, dos solos desses dois tipos de ecossistemas existentes no leste da Amazônia, para subsidiar modelos regionais de clima e avaliação dos efeitos de desmatamento. Além das medidas de campo das variáveis acima citadas, em três níveis até a profundidade de 0,5 m, esse trabalho apresenta estimativas de fluxo de calor e propriedades dos solos, tais como: difusividade e condutividade térmicas, profundidade de amortecimento e velocidade de propagação do pulso de aquecimento diário, determinados por métodos analíticos. Os resultados mostraram o contraste sazonal e outras diferenças significativas de respostas entre os dois sítios estudados, destacando o papel do conteúdo de água nos perfis térmicos verticais em cada tipo de solo. O ajuste obtido entre as medidas e os valores calculados das variáveis, indica a possibilidade de generalização dos resultados para outros sítios de ecossistemas similares na Amazônia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, it was studied the thermal and fluid dynamic behavior from theorical and experimental point of view of a blast furnace tuyere. The tuyere is responsible for the hot air insuflation into the blast furnace. The parameter used in the comparison was the difference between the cooling water inlet and outlet temperatures. There were used forced convection correlations inside circular sections with adequations for non circular sections. Based on operations dates of flux and thermal loads it was possible to model numerically the tuyere, and, since it was obtained the wall temperatures, estimate the conduction and convection resistances and the heat flux through the walls in contact with the water. The total heat fluxes from wall to water were applied to the energy conservation equation where could be estimated the theorical temperature variation. Compared to the real value, the theorical value presented a difference of 0,2 °C. Considering that the boundary conditions around the tuyere are transitories and that your channels have some rugosity irregularities we can consider the estimation method for cooling system coherent with the real operational parameters

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Priestley and Taylor provided a practical formulation of the partitioning of net radiation between heat flux and evaporation contained within a parameter α. Their model (PTM) needs verification under a range of environmental conditions. Micrometeorological data sets collected over the Amazon forest at the Ducke Reserve site (2°57′S; 59°57′W) gave an opportunity to evaluate α. Evidence presented here and by others shows that there is pronounced diurnal variation in α, with minimum values around midday and maximum values in the morning and evening hours. During unstable and stable conditions in the daylight hours, the Bowen ratio (B) varied from 0.10 to 0.57 and -0.71 to -0.08, respectively, whereas α varied from 0.67 to 1.16 and 1.28 to 3.12, respectively. A mean value of α = 1.16±0.56 was obtained from daytime hourly values for two days. The daily data sets from three expeditions gave a mean of α = 1.03±0.13. This work confirms that α is a function of atmospheric stability over the Amazon forest. Thus the PTM should be applied with caution over time-intervals of one day or less because of the sensitivity to variation in α. The calculated values of α are in general agreement with those reported in literature. © 1991.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The massive urbanization and activities arising from the uncontrolled growth of urban areas, result in changes on the climate, making it unhealthy. One factor that contributes to poor quality of life due to this fact is the islands of heat that consists in the accumulation of surface heat and raises the temperature in the cities. The vegetation consists of urban greening, urban forests and green areas, have the function to minimize this effect. To reconcile these factors, collected data on surface temperature by satellite images, LANDSAT 5 captured on 18/12/2012 point 75 e 76, orbits 221, band 6 and on-site survey with thermo-hygrometer, possessed the data, crossing the conducted vegetative survey and provided a management vision to improve the microclimate of the city under study. The vegetation coverage at urban area directly affects the ambient temperature, improving the urban micro-climate. The different analyzed surface coverage also affects the apparent temperature. Among the studied ranks, the eucalyptus cultivation, native forest, urban area and solo exposed areas with greater vegetation cover have mild temperatures and improved microclimate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental flow boiling heat transfer results are presented for horizontal 1.0 and 2.2 mm I. D. (internal diameter) stainless steel tubes for tests with R1234ze(E), a new refrigerant developed as a substitute for R134a with a much lower global warming potential (GWP). The experiments were performed for these two tube diameters in order to investigate a possible transition between macro and microscale flow boiling behavior. The experimental campaign includes mass velocities ranging from 50 to 1500 kg/m(2) s, heat fluxes from 10 to 300 kW/m(2), exit saturation temperatures of 25, 31 and 35 degrees C, vapor qualities from 0.05 to 0.99 and heated lengths of 180 mm and 361 mm. Flow pattern characterization was performed using high speed videos. Heat transfer coefficient, critical heat flux and flow pattern data were obtained. R1234ze(E) demonstrated similar thermal performance to R134a data when running at similar conditions. [DOI: 10.1115/1.4004933]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aims to compare and validate two soil-vegetation-atmosphere-transfer (SVAT) schemes: TERRA-ML and the Community Land Model (CLM). Both SVAT schemes are run in standalone mode (decoupled from an atmospheric model) and forced with meteorological in-situ measurements obtained at several tropical African sites. Model performance is quantified by comparing simulated sensible and latent heat fluxes with eddy-covariance measurements. Our analysis indicates that the Community Land Model corresponds more closely to the micrometeorological observations, reflecting the advantages of the higher model complexity and physical realism. Deficiencies in TERRA-ML are addressed and its performance is improved: (1) adjusting input data (root depth) to region-specific values (tropical evergreen forest) resolves dry-season underestimation of evapotranspiration; (2) adjusting the leaf area index and albedo (depending on hard-coded model constants) resolves overestimations of both latent and sensible heat fluxes; and (3) an unrealistic flux partitioning caused by overestimated superficial water contents is reduced by adjusting the hydraulic conductivity parameterization. CLM is by default more versatile in its global application on different vegetation types and climates. On the other hand, with its lower degree of complexity, TERRA-ML is much less computationally demanding, which leads to faster calculation times in a coupled climate simulation.