711 resultados para Tread extrusion
Resumo:
The food industry is continually growing with new products becoming available every year. Extrusion combines a number of unit operations in one energy efficient rapid continuous process and can be used to produce a wide variety of snacks foods. The objective of this study was to evaluate the effect of extrusion temperature, screw speed, and amount of cassava leaf flour mixed with cassava starch on the physical properties of extruded snacks processed using a single screw extruder. A central composite rotational design, including three factors with 20 treatments, was used in the experimental design. Dependent variables included the expansion index, specific volume, color, water absorption index, and water solubility index. Among the parameters examined, the amount of cassava leaf flour and extrusion temperature showed significant effects on extruded snack characteristics. Mixtures containing 10% of cassava leaf flour extruded at 100 degrees C and 255 rpm shows favorable levels of expansion, color, water absorption index, and water solubility index.
Resumo:
Thoracolumbar disk extrusion is the most common cause of extradural compression of the spinal cord in dogs. Myelography is one of the most commonly performed techniques for the diagnosis of this affection. This study aimed to evaluate the applicability and effectiveness of lumbar myelography in the diagnosis of thoracolumbar intervertebral disk extrusion in dogs, as well as its major complications. Twenty dogs were used in this study. Animals were included when neurological examination suggested thoracolumbar spine lesion, myelography was used as a complementary diagnostic method, and diagnosis of disk extrusion was surgically confirmed. The accuracy of the exam to predict location and lateralization of extruded disk material were evaluated, as well as complications associated to the procedure. Lumbar myelography exhibited 95% and 60% accuracy for location and lateralization of the lesion, respectively, with minimal complications.
Resumo:
The competitiveness among global markets, the constant need for reducing manufacturing costs and also the growing environmental commitments are fueling the development of techniques for recovery residual parts generated by industrial processes. Among the various areas of a company, we highlight those that involve the processing of raw materials derived from oil, such as polymers (resins), which may take centuries to decompose in the environment and also present as a economic and environmentally strategic point. Thus, this study would examine the recovery of waste polypropylene, from the injection process of a major multinational in the field of home appliances through the recycling by a process comprising the milling, extrusion and chipping of waste material. Easy to deploy, this proposal aims to reduce levels negligible disposal (scrap) of these residues as well as the reintegration of the production process into pieces no visual and no structural importance, aimed at cutting costs and reducing environmental impacts caused. After the survey data in kilograms of waste material generated in a given period of time, and the study of changes in material properties, it would enable the reuse steadily in the injection process
Resumo:
The goal of this work is to report some problems that occur in the in the production of aluminum billets (series 6XXX) produced by the hot top process in the Alcoa aluminum Inc. The aluminum fabrication process is described from its first stage, since the mining until the reduction, smelting and treatment of the metal. One of the plant’s final product, are billets for clients that produce profiles by extrusion. The product’s final quality highly depends on the whole production process. Therefore it’s necessary to use good practices in the treatment of the metal, follow up its fabrication and control its thermal treatment, in order to meet the required standards to satisfy the clients. The billet’s production method and its variables will be detailed through temperature and casting speed, cone of water flow, cooling rate, duration of thermal treatment, degassing and metal “in line “filtering, in other words when it’s still found in its liquid state. The non-conformities of the process were studied by metallographic analysis, both macrostutural and microstructural that will be described and discussed in this work
Resumo:
A large part of hydraulic hoses is produced on a mandrel. The mandrel has longer length and circular profile being produced by extrusion of polyamide polymer, which in this case is imported, then the process is depending on the import process, which entails high shipping costs and fees. This work studies the production of recycled mandrel, using the mandrel that is out of dimensional to produce hoses. After the production of recycled mandrel mechanical tensile and hardness were performed both in the natural and recycled mandrel to compare them. It was observed that recycled mandrel presents the tensile properties and hardness superior to natural mandrel. Thus, this work will directly impact the company`s business ultimately reducing costs, reducing waste and reducing environmental impacts
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Pós-graduação em Biotecnologia - IQ
Resumo:
Objective: evaluate the immediate dental and skeletal changes induced by the Herbst appliance on early treatment of Angle´s Class II malocclusion. Material and Method: several electronic databases such as Scopus, Pub Med, Medline, Cochrane Library, Lilacs and Scielo were searched. The abstracts that fullfilled the selection criteria were selected and those that did not provide enough information about these criteria were selected but the final decision of including them or not on the research, was taken after the complete reading of the article. The selection criteria were: clinical studies with Class II individuals, both male and female, with initial age of 7 to 10 years, treated with the Herbst appliance that analysed the dental and/or skeletal changes evaluated on lateral cephalometric radiographs; researches where the treatment performed did not involve extractions or surgical interventions; studies that included patients without syndromes or health concerns and articles published in English or Portuguese. Results and Conclusions: five articles were selected. The articles showed that significant changes happened in the mandibular sagittal lenght, on facial convexity angle, on maxillo-mandibular relationship, on retroclination of the upper incisors and on distal movement of the upper molars, on proclination of the lower incisors and on extrusion of the lower molars. The appliance exerted a limited effect on the anterior relocation of the maxillary complex and on facial heights. However, more studies about the performance of the Herbst appliance on early treatment of Class II are needed.
Resumo:
Forced orthodontic eruption (FOE) is a non-surgical treatment option that allows modifying the osseous and gingival topography. The aim of this article is to present a clinical case of a FOE, which resulted in an improvement of the amount of available bone and soft-tissues for implant site development. Patient was referred for treatment of mobility and unesthetic appearance of their maxillary incisors. Clinical and radiographic examination revealed inflamed gingival tissue, horizontal and vertical tooth mobility and interproximal angular bone defects. It was chosen a multidisciplinary treatment approach using FOE, tooth extraction, and immediate implant placement to achieve better esthetic results. The use of FOE, in periodontally compromised teeth, promoted the formation of a new bone and soft-tissue in a coronal direction, without additional surgical procedures, enabling an esthetic, and functional implant-supported restoration.
Resumo:
The aim of this paper is to present a complex rehabilitation, of fractured tooth, with implants in anterior region considering the orthodontics extrusion to clinical success. At 7 years old, the patient fractured the maxillary left central incisor and the dentist did a crown with the fragment. Twenty years later, the patient was referred to a dental clinic for orthodontic treatment, with the chief complaint related to an accentuated deep bite, and a professional started an orthodontic treatment. After sixteen months of orthodontic treatment, tooth 21 fractured. The treatment plan included an orthodontic extrusion of tooth 21 and implant placement. This case has been followed up and the clinical and radiographic examinations show excellence esthetic results and satisfaction of patient. The forced extrusion can be a viable treatment option in the management of crown root fracture of an anterior tooth to gain bone in a vertical direction. This case emphasizes that to achieve the esthetic result a multidisciplinary approach is necessary.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
The purpose of this study was to evaluate the macroscopy and microstructure of a double setting alpha-tricalcium phosphate bone cement sphere provided with interconnection channels (alpha-TCP-i), as well as the integration of the implant with the rabbits' orbital tissue, through macroscopic analysis and histopathology. The external and internal surfaces of the alpha-TCP-i were evaluated macroscopically and by electron microscopy. Twelve New Zealand rabbits received 12mm implants of alpha-TCP-i following enucleation of the left eye. The clinical assessment was undertaken daily during the first 15 days, followed by fortnightly assessment until the end of the study period. For the morphological analysis, exenteration was performed in 3 animals per experimental period (15, 45, 90 and 180 days). The external and internal surfaces of the implant appeared solid, smooth and compact, with six channels which interconnected centrally. The micro-architecture was characterized by the formation of columns of hexagonal crystals. No signs of infection, exposure, dehiscence of sutures or extrusion of the implant were noted in any of the animals during the entire period of the study. The morphological evaluation demonstrated the presence of a thin capsule around the implant, from whence appeared fibro-vascular projections, which penetrated it through the interconnecting channels. In the first days after the insertion of the implant, an intense inflammatory reaction was noted. At 180 days, however, there were no signs of inflammation. The alpha-tricalcium phosphate cement implant was well tolerated in this rabbit model and appeared to be relatively inert with some fibrovascular ingrowth through the large channels.
Resumo:
Pós-graduação em Artes - IA