646 resultados para Transtibial prostheses
Resumo:
The objective of modern odontology is to reconstitute to the patient the comfort, the function, the aesthetic form, the phonetic capability, and normal health. However, the more the patient is toothless, the more this objective becomes difficult inside traditional dentistry. As a result of continuous research of materials and techniques, permissible success is now a reality, whitewashing many challenging clinical situations. Thus, the objective of the article was to present a clinical case where association of the universal cast to long abutment pillars and EsthetiCone were used for aesthetic whitewashing. A man presented to the clinic of the Faculty of Dentistry, Universidade Estadual Paulista. After clinical examination and radiographic evaluation evidenced the necessity of substitution of fixed prostheses (15-25), he was presented with disadaptation and a favorable aesthetic solution. Ahead of the evaluated picture and considering the extension of the toothless space made, it was opted more, to the accomplishment of surgery, the setting of 2 implantations in the region and 2 in each edentate side of the posterior portion of the jaw. On 6 implants and 2 teeth, 10 metal ceramic crowns had been confectioned: 4 of them being joined in the region of the 12 to the 22 and the other 6 as unit crowns in the region of the 13, the 14, the 15, the 23, the 24, and the 25. The carried-through treatment was capable to return the aesthetic form, the function, the phonetic capability, the comfort, and the health of the verbal socket.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.
Resumo:
A white female patient presented to the university clinic to obtain implant retained prostheses. She had an edentulous maxillary jaw and presented three teeth with poor prognosis (33, 34 and 43). The alveolar bone and the surrounding tissues were healthy. The patient did not report any relevant medical history contraindicating routine dental treatment or implant surgery, but self-reported a dental history of asymptomatic nocturnal bruxism. The treatment plan was set and two Branemark protocols supported by six implants in each arch were installed after a 6-month healing period. A soft occlusal splint was made due to the patient's history of bruxism, and the lack of its use by the patient resulted in an acrylic fracture. The prosthesis was repaired and the importance of using the occlusal splint was restated. In the 4-year follow-up no fractures were reported.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The treatment of orofacial tumors may cause facial deformities by losses of structures that affect basic functions, i.e. feeding, speech, and the reduction of patient self-steam. A white male patient was diagnosed with epidermoid cancer on the mandibular alveolar ridge with infiltration staging IV A. The patient was submitted to a mandibulectomy associated with a complete extraction of mandibular teeth. For rehabilitation, a conventional denture for the mandibular arch and a removable partial denture for the maxillary arch were fabricated. A correct occlusal adjustment and a satisfactory amount of alveolar bone was favorable for conventional dentures of the prostheses bases improve their retention and stability. After one year of follow-up, the patient was adapted to the prostheses, satisfied with their retention, and reported an improvement on his feeding. The prosthetic rehabilitation of patients after a partial mandibulectomy is essential for their self-steam. Conventional dentures may have their retention and stability improved if they are well fabricated, recorded and have a balanced occlusion. A correct occlusal adjustment and an adequate retention of the prostheses bases may improve their retention and stability. Patients without xerostomy and with a satisfactory amount of alveolar bone may have a favorable prognosis for conventional dentures.
Resumo:
This systematic review aimed to evaluate if the internal connection is more efficient than the external connection and its associated influencing factors. A specific question was formulated according to the Population, Intervention, Control, and Outcome (PICO): Is internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? An electronic search of the MEDLINE and the Web of Knowledge databases was performed for relevant studies published in English up to November 2013 by two independent reviewers. The keywords used in the search included a combination of dental implant and internal connection or Morse connection or external connection. Selected studies were randomized clinical trials, prospective or retrospective studies, and in vitro studies with a clear aim of investigating the internal and/or external implant connection use. From an initial screening yield of 674 articles, 64 potentially relevant articles were selected after an evaluation of their titles and abstracts. Full texts of these articles were obtained with 29 articles fulfilling the inclusion criteria. Morse taper connection has the best sealing ability. Concerning crestal bone loss, internal connections presented better results than external connections. The limitation of the present study was the absence of randomized clinical trials that investigated if the internal connection was more efficient than the external connection. The external and internal connections have different mechanical, biological, and esthetical characteristics. Besides all systems that show proper success rates and effectiveness, crestal bone level maintenance is more important around internal connections than external connections. The Morse taper connection seems to be more efficient concerning biological aspects, allowing lower bacterial leakage and bone loss in single implants, including aesthetic regions. Additionally, this connection type can be successfully indicated for fixed partial prostheses and overdenture planning, since it exhibits high mechanical stability.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to analyze the stress distribution of short implants supporting single unit or splinted crowns by the photo-elasticity method. Four photo-elastic models were produced: A (3.75×7mm); B (3.75×7mm, 3.75×7mm and 3.75×7mm); C (3.75×10mm, 3.75×7mm and 3.75×7mm); D (3.75×13mm, 3.75×7mm and 3.75×7mm). The prostheses were made with Ni-Cr alloy. A load of 100N in the axial and oblique directions was applied, totaling 380 applications, individually capturing their images in each model. The data were randomized and analyzed qualitatively and quantitatively by 2 examiners. The oblique loading was significantly more damaging. The increase in length was favorable for stress distribution (p<0.05). The splinting was beneficial for the transmission of stresses mainly (p<0.05). The splinting of the crowns, as well as increasing the length of the first implant and axial loading was most beneficial in the stress distribution. Short splinted implants behaved better than single unit implants. Increasing of the length of the first implant significantly improved the stress distribution in all analyzed situations.
Resumo:
The technique proposed aims at reducing the weight of individualized ample ocular prostheses using acrylic resins as well as simplifying laboratory procedure. For that, prefabricated hollow spheres made of plastic material, were inserted in the sclera. The average weights of the solid conventional sclera (5.30g) and those of the respective prefabricated plastic ones (3.91g) were compared. The weight reduction was significative with a confidence interval of 95% by the Student t test. ln addition, for illustration purpose, the technique was applied to patients in the ward of the Maxillofacial Prostheses Dicipline of the Dentistry School in the Campus of São José dos Campos - UNESP, having each patient received a solid prosthesis and a hollow prefabricated one made of plastic material. It has been concluded that the prostheses material spheres were inserted are lighter than the ones which received solid spheres; furthermore, thr technique is viable for ample anophtalmic cavities and requires few sessions
Resumo:
For oral rehabilitation with implant-supported prostheses, there are required procedures to create the bone volume needed for installation of the implants. Thus, bone grafts from intraoral or extraoral donor sites represent a very favorable opportunity. This study aimed to review the literature on the subject, seeking to discuss parameters for the indications, advantages and complications of techniques for autogenous bone grafts.
Resumo:
Objectives: This study aimed to assess dimensional changes in acrylic resin base and artificial teeth position after water storage and thermocycling using computer graphics measurements. Methods: Twenty-four waxed replicas were obtained from a previous upper complete denture. For linear measurements, points in cusps tips of left central incisor and second premolars and molars were marked in one of the prostheses with graphite and transferred to the others using an acrylic resin guide. The prostheses were scanned after waxing, polymerization and treatments and the images were exported to “AutoCad 2002 Today®” software for measurements. Results: There was no statistically significant difference in changes of each segment for each group and between the phases evaluated after polymerization and thermocycling. In groups I and III, the values after polymerization are higher than those after treatment, which suggests shrinkage while the prostheses in group II have expanded. Conclusion: The three groups exhibited artificial teeth movement after tests in comparison to the polymerized prosthesis. The prostheses submitted to water storage in kiln at 36ºC during seven days showed different behavior than the other groups.
Resumo:
The aim of his study was to review the current scientific literature in order to discuss the surgical, prosthetics and psychological/psychosocial aspects during the treatment planning of edentulous patients, when a total fixed prosthesis or overdenture is indicated. To identify studies to take part in this review, a search was conducted for the following databases: PubMed, Dentistry and Oral Sciences Source, Journals@Ovid, SpringerLink, Wiley Online Library, Nature (NPG), Oxford Journals. It was used as descriptors: total fixed prostheses and overdentures. Inclusion criteria were: clinical articles, clinical case reports, case series, literature reviews and systematic reviews that addressed the study and comparison of total fixed prostheses and overdentures for a surgical- prosthetic planning. Exclusion criteria were: laboratory and in vitro studies and those whose first language was not English or Portuguese. Of a total of 454 articles, after an analysis according to inclusion and exclusion criteria, 76 articles were selected. During an implantsupported prosthesis rehabilitation with dental in edentulous patients, the use of alternative procedures appear to be effective when compared to more invasive surgical techniques, and thus, the amount of dental implants possible to install associated with prosthetic issues such as lip support, smile line, quantity and quality of mucosa, phonetics, etc., will allow an appropriate treatment planning to each clinical case
Resumo:
Halitosis is the unpleasant odor of exhaust air through the mouth and lungs. There are over 50 causes, and approximately 90% of cases, is of oral origin. May have physiological origin (stress, breath of morning, fasting, and inappropriate diets), local reasons (bad oral hygiene, bacterial plaque retained on the tongue and/or tonsils, lower production of saliva, gum disease) or systemic reasons (diabetes, kidney or liver problems, constipation, etc.). In the Third Age, this problem tends to increase significantly. Thus, the aim of this study was to detect the presence of halitosis in the geriatric group attended in the dental clinic of UNIRP, identifying their incidence and principal causes. The sample consisted of 48 volunteer patients aged 60 years or older and included more than 90% of patients treated in this age group. It was performed a anamnesis and physical examination. The intra-oral halitosis was detected using a breath meter (halimeter). In the group studied, approximately 54.16% had halitosis, 84.61% of these were users of the prosthesis. The tongue coating was present in 80.76% of individuals with halitosis. After brushing the tongue, 88.46% of patients with halitosis have had the initial index oral malodor decreased. Based on the results of this study it was concluded that factors as dental prostheses and tongue coating are critical factors in causing halitosis.
Resumo:
Zirconia abutments are used to obtain satisfactory aesthetic results in implant fixed anterior prostheses when metal abutments promote a grayish mucosal discoloration of the peri-implant soft tissues. However, there is a lack of studies to confirm the clinical performance of the peri-implant soft tissues surrouding zirconia abutments. This study described a case report of a patient treated with implant fixed all-ceramic crown made out on zirconia abutment after 3 years of followup. A 47-year-old female patient was admitted to the dental clinic (Aracatuba Dental School) complaining about the fracture of her implant fixed single crown in the region of the left lateral incisor. The patient chose the replacement of the fractured prosthesis for an allceramic crown. After 3 years of follow-up it was observed that maintenance of the aesthetic results and the peri-implant soft tissue without any inflammation or gingival recessions. Within the limitations of a case report, it can be conclude that zirconia abutments is a effective rehabilitation treatment because it preserves the aesthetics and function through the maintenance of peri-implant tissues.