975 resultados para Tomografia axial computorizada
Resumo:
In this work we consider the two-point Green's functions in (1 + 1)-dimensional quantum electrodynamics and show that the correct implementation of analytic regularization gives a gauge invariant result for the vacuum polarization amplitude and the correct coefficient for the axial anomaly.
Resumo:
BACKGROUND: Ultrasonography (US), Computed Tomography (CT), and Magnetic Resonance imaging (MR) were compared for the staging of renal tumors. The differences between these imaging techniques were also studied for their ability to detect adenopathies, vascular invasion, distant intra-abdominal metastases, and particularly adjacent organ invasion. METHODS: Thirty-one patients with solid or complex renal masses were prospectively studied using US, CT, and MR. Differences between the results obtained were studied using the COCHRAN G test and the McNEMAR test. The sensitivity and specificity of each diagnostic technique were compared against a gold standard of the surgical and histopathological findings. RESULTS: The following sensitivities were obtained: For the detection of adenopathy, US 63.6%, CT and MR 90.9%. For vascular invasion, US 42.8%, CT and MR 85.7%. For the adjacent organ invasion, US 28.5%, CT 85.7%, and MR 71.4%. Some of the criteria that suggest invasion of adjacent structures include: the envelopment of the adjacent structures by the tumor, tumor extension into the adjacent structures with an irregular appearance, and alterations in shape, size, and density of adjacent structures. Loss of fat planes between the tumor and adjacent structures is not a sign of tumor invasion. CONCLUSIONS: Significant differences were found in the detection capacity of US in relation to CT and MR, which were similar. All three techniques were highly sensitive and specific only in the detection of distant abdominal metastases. In addition to the accuracy of these diagnostic modalities for the detection and staging of tumors, invasiveness, risks and cost should be considered in relation to relative costs and benefits.
Resumo:
Introduction: Orthodontics has always used lateral cephalometric radiographs (LC) as the main examination in the orthodontic diagnosis and treatment plan. The determination of incisor position is part of most cephalometric analysis, including Tweed analysis. However, all radiographic images have limitations, since it is a bidimensional image of a tridimensional structure and overlapping of bone and dental structures often occurs. Computed tomography (CT) allows a trustworthy diagnostic, mainly for its tridimensional images possibility. In this situation it seems reasonable to question the classic cephalometric analysis, creating factors of comparison with computed tomography data. Aim: For this, it was considered the evaluation of the angle between the long axis of the inferior incisor and the mandibular plane (IMPA) in the lateral cephalograph and in the computed tomography. Methods: Nineteen patients, selected for orthodontic treatment, had constituted the sample of this study, 12 female and 7 male, with ages between 16 years and 4 months and 28 years and 2 months. After the collection of data made by two examiners, statistical analyses for the attainment of the errors intra and inter-examiners had been made, using level of significance of 5%. Results and Conclusion: It was concluded that IMPA can be measured in the lateral cephalometric radiographs with trustworthiness, even that its values were smaller when compared with the computed tomography.
Resumo:
OBJECTIVE: To obtain mean angulation values for renal hila in relation to the horizontal plane traced over the right and left spinal erector muscles, considering the center of the lumbar vertebral spine as a parameter for measuring the renal hila angles. MATERIALS AND METHODS: The authors have analyzed 250 abdominal computed tomography studies of both male and female healthy individuals (128 men with mean age 52.45 ± 17.42 years, and 122 women with mean age 54.39 ± 18.27 years), corresponding to 500 renal hila evaluated. The mean angulation of each hilum in relation to the horizontal plane was obtained taking acute angles into consideration. RESULTS: The comparative study have not found any statistically significant difference in acute angles of renal hila between male and female individuals. The statistical analysis demonstrated limits of 40.40° and 44.54° for mean right hilum angulation and 39.91° and 43.23° for mean left hilum angulation, with a confidence interval of 95% CONCLUSION: Renal hila present similar angulation independently of sex. Higher angulation values correspond to hyper-rotation or excessive rotation, and lower angulation values, to incomplete or reverse rotation. © Colégio Brasileiro de Radiologia e Diagnóstico por Imagem.
Resumo:
The correct radiographic identification of ossification of the pterygospinous and pterygoalar ligaments plays an important role in surgical procedures for the treatment of trigeminal neuralgia. Most of these procedures are performed through the foramen ovale, a site where these ligaments can be found to be partially or completely ossified. We studied the radiographic features of these ossified ligaments and their location in relation to the foramen ovale by the Hirtz axial technique. For this purpose, 93 dry skulls from the Discipline of Anatomy, São José dos Campos Dental School, UNESP, which presented partial or complete ossification of these ligaments, were radiographed. The pterygospinous ligament was detected on 27.97% of radiographs and was partially ossified in 19.36% of cases and completely ossified in 8.61%. The pterygoalar ligament was present in 62.35% of radiographs, being partially ossified in 49.44% and completely ossified in 12.91%. The pterygospinous ligaments was found to be partially and completely ossified on the same radiograph in 3.23% of cases, whereas the pterygoalar ligament appeared partially and completely ossified on the same radiograph in 6.45%. Furthermore, the pterygospinous ligament was thinner than the pterygoalar ligament and located more medially in relation to the foramen ovale. The pterygoalar ligament formed a large bone bar lateral to the foramen ovale, often obliterating the lumen of the latter. The Hirtz axial technique is an excellent tool for the observation of complete or partial ossification of the pterygospinous and pterygoalar ligaments in surgical procedures for the treatment of trigeminal neuralgia performed through the foramen ovale.
Resumo:
Considering that the cutaneous flap can be affected by isquemic complications the extra corporeal shock wave therapy (ESWT) was described as rescue techniques. The present study was developed to analyze histological and with morfometry, twenty one skin samples treated or not with the shock wave therapy, obtained from flap's distal border, used in this study to repair eyelids' experimental defects in dogs. The flap with or without ESWT did not show any histological sign of inflammatory or atrophic alterations. Both group treated showed similar morphometrical characteristics. The ESWT with the protocol used in this study (2500 impulses at 0,15 mJ/mm 2) did not demonstrate significant clinical outcomes as a rescue technique when applied over the oris angularis flap, however results showed no signals of collateral deleterious effects.
Resumo:
Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 με) and point D the highest (442.77 με). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.
Resumo:
The substitution of steel as a raw material in the production of axial pistons for pressure washers by polyphthalamide, polytetrafluoroethylene and glass fiber-based composite was studied. The new production process with composite consists of only two steps, while the production of the steel piston is to comprise of thirteen steps. This replacement would result in an estimated reduction of 80% of water consumption, 83% of electricity consumption, 73% of the total cost and 88% of the final mass. With regard to the main mechanical properties required for the end product, the composite was found to withstand the critical axial loads and it shows acceptable wear resistance in an environment without lubrication, an additional advantage of this replacement. © 2012 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)