870 resultados para Time Use


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The 2×2 MIMO profiles included in Mobile WiMAX specifications are Alamouti’s space-time code (STC) fortransmit diversity and spatial multiplexing (SM). The former hasfull diversity and the latter has full rate, but neither of them hasboth of these desired features. An alternative 2×2 STC, which is both full rate and full diversity, is the Golden code. It is the best known 2×2 STC, but it has a high decoding complexity. Recently, the attention was turned to the decoder complexity, this issue wasincluded in the STC design criteria, and different STCs wereproposed. In this paper, we first present a full-rate full-diversity2×2 STC design leading to substantially lower complexity ofthe optimum detector compared to the Golden code with only a slight performance loss. We provide the general optimized form of this STC and show that this scheme achieves the diversitymultiplexing frontier for square QAM signal constellations. Then, we present a variant of the proposed STC, which provides a further decrease in the detection complexity with a rate reduction of 25% and show that this provides an interesting trade-off between the Alamouti scheme and SM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we introduce a pilot-aided multipath channel estimator for Multiple-Input Multiple-Output (MIMO) Orthogonal Frequency Division Multiplexing (OFDM) systems. Typical estimation algorithms assume the number of multipath components and delays to be known and constant, while theiramplitudes may vary in time. In this work, we focus on the more realistic assumption that also the number of channel taps is unknown and time-varying. The estimation problem arising from this assumption is solved using Random Set Theory (RST), which is a probability theory of finite sets. Due to the lack of a closed form of the optimal filter, a Rao-Blackwellized Particle Filter (RBPF) implementation of the channel estimator is derived. Simulation results demonstrate the estimator effectiveness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multiple-input multiple-output (MIMO) techniques have become an essential part of broadband wireless communications systems. For example, the recently developed IEEE 802.16e specifications for broadband wireless access include three MIMOprofiles employing 2×2 space-time codes (STCs), and two of these MIMO schemes are mandatory on the downlink of Mobile WiMAX systems. One of these has full rate, and the other has full diversity, but neither of them has both of the desired features. The third profile, namely, Matrix C, which is not mandatory, is both a full rate and a full diversity code, but it has a high decoder complexity. Recently, the attention was turned to the decodercomplexity issue and including this in the design criteria, several full-rate STCs were proposed as alternatives to Matrix C. In this paper, we review these different alternatives and compare them to Matrix C in terms of performances and the correspondingreceiver complexities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The anti-diuretic neurohypophysial hormone Vasopressin (Vp) and its synthetic analogue Desmopressin (Dp, 1-desamino-vasopressin) have received considerable attention from doping control authorities due to their impact on physiological blood parameters. Accordingly, the illicit use of Desmopressin in elite sport is sanctioned by the World Anti-Doping Agency (WADA) and the drug is classified as masking agent. Vp and Dp are small (8-9 amino acids) peptides administered orally as well as intranasally. Within the present study a method to determine Dp and Vp in urinary doping control samples by means of liquid chromatography coupled to quadrupole high resolution time-of-flight mass spectrometry was developed. After addition of Lys-Vasopressin as internal standard and efficient sample clean up with a mixed mode solid phase extraction (weak cation exchange), the samples were directly injected into the LC-MS system. The method was validated considering the parameters specificity, linearity, recovery (80-100%), accuracy, robustness, limit of detection/quantification (20/50 pg mL(-1)), precision (inter/intra-day<10%), ion suppression and stability. The analysis of administration study urine samples collected after a single intranasal or oral application of Dp yielded in detection windows for the unchanged target analyte for up to 20 h at concentrations between 50 and 600 pg mL(-1). Endogenous Vp was detected in concentrations of approximately 20-200 pg mL(-1) in spontaneous urine samples obtained from healthy volunteers. The general requirements of the developed method provide the characteristics for an easy transfer to other anti-doping laboratories and support closing another potential gap for cheating athletes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To enhance the clinical value of coronary magnetic resonance angiography (MRA), high-relaxivity contrast agents have recently been used at 3T. Here we examine a uniform bilateral shadowing artifact observed along the coronary arteries in MRA images collected using such a contrast agent. Simulations were performed to characterize this artifact, including its origin, to determine how best to mitigate this effect, and to optimize a data acquisition/injection scheme. An intraluminal contrast agent concentration model was used to simulate various acquisition strategies with two profile orders for a slow-infusion of a high-relaxivity contrast agent. Filtering effects from temporally variable weighting in k-space are prominent when a centric, radial (CR) profile order is applied during contrast infusion, resulting in decreased signal enhancement and underestimation of vessel width, while both pre- and postinfusion steady-state acquisitions result in overestimation of the vessel width. Acquisition during the brief postinfusion steady-state produces the greatest signal enhancement and minimizes k-space filtering artifacts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate the use and records of the Child Health Handbook (CHH), especially growth and development. Method Cross-sectional study with 358 mother-child pairs registered in 12 Primary Health Centers (PHCs) of a small municipality. Mothers were interviewed at the PHC from February to April 2013 using a questionnaire. Data analysis was done using WHO Anthro software, Epi InfoTM and Stata. Results Fifty-three percent of the mothers were carrying the CHH at the time of the interview, similar to the proportion of mothers who were instructed to bring the CHH to health appointments. Annotations in the CHH during the visits were reported by 49%. The vaccination schedule was completed in 97% of the CHH, but only 9% and 8% of the CHH, respectively, contained growth charts and properly completed developmental milestones. Conclusion Low rates of use and unsatisfactory record-keeping in the CHH reinforce the need for investment in professional training and community awareness for the CHH to become an effective instrument of promotion of child health.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of cages of different material and shapes for cervical discectomy with fusion (ACDF) has increased during the last few years. The use of additional osteogenic material is controversial. We prospectively evaluated an empty, Plasmapore-covered titanium cage (PCTC) in 45 patients undergoing 58 ACDFs. Patients were evaluated using standard clinical and radiological criteria. Good to excellent outcome was achieved in 93%, 78% and 75% after 3, 12 and 48 months, respectively. Sixty-five percent of patients could resume their prior work after 48 months. Disc space height and lordosis could be preserved in all cases. Two percent of the treated levels showed subsidence and 2% increased segmental motion. There were no procedure-related complications. Implantation of an empty PCTC after microsurgical anterior cervical discectomy is a safe procedure with good results and low incidence of complications. Disc height and lordosis can be preserved with low incidence of subsidence and good fusion rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cannabis use among adolescents and young adults has become a major public health challenge. Several European countries are currently developing short screening instruments to identify 'problematic' forms of cannabis use in general population surveys. One such instrument is the Cannabis Use Disorders Identification Test (CUDIT), a 10-item questionnaire based on the Alcohol Use Disorders Identification Test. Previous research found that some CUDIT items did not perform well psychometrically. In the interests of improving the psychometric properties of the CUDIT, this study replaces the poorly performing items with new items that specifically address cannabis use. Analyses are based on a sub-sample of 558 recent cannabis users from a representative population sample of 5722 individuals (aged 13-32) who were surveyed in the 2007 Swiss Cannabis Monitoring Study. Four new items were added to the original CUDIT. Psychometric properties of all 14 items, as well as the dimensionality of the supplemented CUDIT were then examined using Item Response Theory. Results indicate the unidimensionality of CUDIT and an improvement in its psychometric performance when three original items (usual hours being stoned; injuries; guilt) are replaced by new ones (motives for using cannabis; missing out leisure time activities; difficulties at work/school). However, improvements were limited to cannabis users with a high problem score. For epidemiological purposes, any further revision of CUDIT should therefore include a greater number of 'easier' items.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Interventional catheterization is being increasingly used for relief of residual lesions in congenital heart disease. Exact anatomical imaging is crucial in the planning of an intervention. This can be provided non-invasively and without radiation by contrast-enhanced MR angiography (CEMRA). Aim: To evaluate the accuracy of the measurements of the vessels obtained by CEMRA in comparison to those obtained by conventional X-ray angiography (CXA). Methods: Retrospective blinded measurement of the diameters of aorta and pulmonary arteries on the CEMRA and CXA images, in the same locations. Comparison of the results by Pearson correlation and by calculating the limits of agreement. Results: Twenty-one children with congenital heart disease, mean age 5.6 +- 5.2 years, weight 21.1 +- 18.4 kg, underwent CEMRA and catheterization for assessment or treatment of a residual lesion. The time interval between the CEMRA and the CXA examination was 2.6 +- 2.3 months. A total of 98 measurements, 37 of the aorta and 61 of the pulmonary arteries were performed on the images obtained by each technique. The correlation between CEMRA and CXA measurements was excellent, r = 0.97, p < 0.0001. The mean difference between the two techniques was 0.018 +- 1.1mm; the limits of agreement were -2.14 and +2.18mm. Similar agreement was found for measures of the aorta (r +- 0.97, mean difference 0.20 = 1.08 mm) and of the pulmonary arteries (r +- 0.97, mean difference 0.048 = 0.89 mm). Conclusions: CEMRA provide accurate quantitative anatomical information, which highly agrees with CXA data, and can therefore be used for planning interventional catheterization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: We studied the influence of noninjecting and injecting drug use on mortality, dropout rate, and the course of antiretroviral therapy (ART), in the Swiss HIV Cohort Study (SHCS). METHODS: Cohort participants, registered prior to April 2007 and with at least one drug use questionnaire completed until May 2013, were categorized according to their self-reported drug use behaviour. The probabilities of death and dropout were separately analysed using multivariable competing risks proportional hazards regression models with mutual correction for the other endpoint. Furthermore, we describe the influence of drug use on the course of ART. RESULTS: A total of 6529 participants (including 31% women) were followed during 31 215 person-years; 5.1% participants died; 10.5% were lost to follow-up. Among persons with homosexual or heterosexual HIV transmission, noninjecting drug use was associated with higher all-cause mortality [subhazard rate (SHR) 1.73; 95% confidence interval (CI) 1.07-2.83], compared with no drug use. Also, mortality was increased among former injecting drug users (IDUs) who reported noninjecting drug use (SHR 2.34; 95% CI 1.49-3.69). Noninjecting drug use was associated with higher dropout rates. The mean proportion of time with suppressed viral replication was 82.2% in all participants, irrespective of ART status, and 91.2% in those on ART. Drug use lowered adherence, and increased rates of ART change and ART interruptions. Virological failure on ART was more frequent in participants who reported concomitant drug injections while on opiate substitution, and in current IDUs, but not among noninjecting drug users. CONCLUSIONS: Noninjecting drug use and injecting drug use are modifiable risks for death, and they lower retention in a cohort and complicate ART.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The emphasis on integrated care implies new incentives that promote coordinationbetween levels of care. Considering a population as a whole, the resource allocation systemhas to adapt to this environment. This research is aimed to design a model that allows formorbidity related prospective and concurrent capitation payment. The model can be applied inpublicly funded health systems and managed competition settings.Methods: We analyze the application of hybrid risk adjustment versus either prospective orconcurrent risk adjustment formulae in the context of funding total health expenditures for thepopulation of an integrated healthcare delivery organization in Catalonia during years 2004 and2005.Results: The hybrid model reimburses integrated care organizations avoiding excessive risktransfer and maximizing incentives for efficiency in the provision. At the same time, it eliminatesincentives for risk selection for a specific set of high risk individuals through the use ofconcurrent reimbursement in order to assure a proper classification of patients.Conclusion: Prospective Risk Adjustment is used to transfer the financial risk to the healthprovider and therefore provide incentives for efficiency. Within the context of a National HealthSystem, such transfer of financial risk is illusory, and the government has to cover the deficits.Hybrid risk adjustment is useful to provide the right combination of incentive for efficiency andappropriate level of risk transfer for integrated care organizations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper tests the internal consistency of time trade-off utilities.We find significant violations of consistency in the direction predictedby loss aversion. The violations disappear for higher gauge durations.We show that loss aversion can also explain that for short gaugedurations time trade-off utilities exceed standard gamble utilities. Ourresults suggest that time trade-off measurements that use relativelyshort gauge durations, like the widely used EuroQol algorithm(Dolan 1997), are affected by loss aversion and lead to utilities thatare too high.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, generalizing results in Alòs, León and Vives (2007b), we see that the dependence of jumps in the volatility under a jump-diffusion stochastic volatility model, has no effect on the short-time behaviour of the at-the-money implied volatility skew, although the corresponding Hull and White formula depends on the jumps. Towards this end, we use Malliavin calculus techniques for Lévy processes based on Løkka (2004), Petrou (2006), and Solé, Utzet and Vives (2007).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives The objective of this article is to describe the development of an anatomically accurate simulator in order to aid the training of a perinatal team in the insertion and removal of a fetal endoscopic tracheal occlusion (FETO) balloon in the management of prenatally diagnosed congenital diaphragmatic hernia. Methods An experienced perinatal team collaborated with a medical sculptor to design a fetal model for the FETO procedure. Measurements derived from 28-week fetal magnetic resonance imaging were used in the development of an anatomically precise simulated airway within a silicone rubber preterm fetal model. Clinician feedback was then used to guide multiple iterations of the model with serial improvements in the anatomic accuracy of the simulator airway. Results An appropriately sized preterm fetal mannequin with a high-fidelity airway was developed. The team used this model to develop surgical skills with balloon insertion, and removal, and to prepare the team for an integrated response to unanticipated delivery with the FETO balloon still in situ. Conclusions This fetal mannequin aided in the ability of a fetal therapy unit to offer the FETO procedure at their center for the first time. This model may be of benefit to other perinatal centers planning to offer this procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we use Malliavin calculus techniques to obtain an expression for the short-time behavior of the at-the-money implied volatility skew for a generalization of the Bates model, where the volatility does not need to be neither a difussion, nor a Markov process as the examples in section 7 show. This expression depends on the derivative of the volatility in the sense of Malliavin calculus.