991 resultados para Switch-type sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The success of artificial prosthetic replacements depends on the fixation of the artificial prosthetic component after being implanted in the thighbone. The materials for fixation are subject to mechanical stresses, which originate permanent deformations, incipient cracks and even fatigue fractures. This work shows the possibility of monitoring the mechanical stress over time in prosthesis. In this way, highly sensitive silicon thin-film piezoresistive sensors were developed attached to prosthesis and their results compared with commercial strain gauge sensors. Mechanical stress-strain experiments were performed in compressive mode, during 10,000 cycles. Experimental data was acquired at mechanical vibration frequencies of 0.5 Hz, 1 Hz and 5 Hz, and sent to a computer by means of a wireless link. The results show that there is a decrease in sensitivity of the thin-film silicon piezoresistive sensors when they are attached to the prosthesis, but this decrease does not compromise its monitoring performance. The sensitivity, compared to that of commercial strain gauges, is much larger due to their higher gauge factors (-23.5), when compared to the GFs of commercial sensors (2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The variation of the physical properties of four differ- ent carbon nanofibers (CNFs), based-polymer nano- composites incorporated in the same polypropylene (PP) matrix by twin-screw extrusion process was investigated. Nanocomposites fabricated with CNFs with highly graphitic outer layer revealed electrical isolation-to-conducting behaviors as function of CNF’s content. Nanocomposites fabricated with CNFs with an outer layer consisting on a disordered pyro- litically stripped layer, in contrast, revealed better mechanical performance and enhanced thermal sta- bility. Further, CNF’s incorporation into the polymer increased the thermal stability and the degree of crystallinity of the polymer, independently on the filler content and type. In addition, dispersion of the CNFs’ clusters in PP was analyzed by transmitted light opti- cal microscopy, and grayscale analysis (GSA). The results showed a correlation between the filler concentration and the variance, a parameter which measures quantitatively the dispersion, for all composites. This method indicated a value of 1.4 vol% above which large clusters of CNFs cannot be dispersed effectively and as a consequence only slight changes in mechanical performance are observed. Finally, this study establishes that for tailoring the physical properties of CNF based-polymer nanocomposites, both adequate CNFs structure and content have to be chosen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryptographic software development is a challenging eld: high performance must be achieved, while ensuring correctness and com- pliance with low-level security policies. CAO is a domain speci c language designed to assist development of cryptographic software. An important feature of this language is the design of a novel type system introducing native types such as prede ned sized vectors, matrices and bit strings, residue classes modulo an integer, nite elds and nite eld extensions, allowing for extensive static validation of source code. We present the formalisation, validation and implementation of this type system

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The intensive use of semiconductor devices enabled the development of a repetitive high-voltage pulse-generator topology from the dc voltage-multiplier (VM) concept. The proposed circuit is based on an odd VM-type circuit, where a number of dc capacitors share a common connection with different voltage ratings in each one, and the output voltage comes from a single capacitor. Standard VM rectifier and coupling diodes are used for charging the energy-storing capacitors, from an ac power supply, and two additional on/off semiconductors in each stage, to switch from the typical charging VM mode to a pulse mode with the dc energy-storing capacitors connected in series with the load. Results from a 2-kV experimental prototype with three stages, delivering a 10-mu s pulse with a 5-kHz repetition rate into a resistive load, are discussed. Additionally, the proposed circuit is compared against the solid-state Marx generator topology for the same peak input and output voltages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new circuit topology is proposed to replace the actual pulse transformer and thyratron based resonant modulator that supplies the 60 kV target potential for the ion acceleration of the On-Line Isotope Mass Separator accelerator, the stability of which is critical for the mass resolution downstream separator, at the European Organization for Nuclear Research. The improved modulator uses two solid-state switches working together, each one based on the Marx generator concept, operating as series and parallel switches, reducing the stress on the series stacked semiconductors, and also as auxiliary pulse generator in order to fulfill the target requirements. Preliminary results of a 10 kV prototype, using 1200 V insulated gate bipolar transistors and capacitors in the solid-state Marx circuits, ten stages each, with an electrical equivalent circuit of the target, are presented, demonstrating both the improved voltage stability and pulse flexibility potential wanted for this new modulator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present an amorphous silicon device that can be used in two operation modes to measure the concentration of ions in solution. While crystalline devices present a higher sensitivity, their amorphous counterpart present a much lower fabrication cost, thus enabling the production of cheap disposable sensors for use, for example, in the food industry. The devices were fabricated on glass substrates by the PECVD technique in the top gate configuration, where the metallic gate is replaced by an electrolytic solution with an immersed Ag/AgCl reference electrode. Silicon nitride is used as gate dielectric enhancing the sensitivity and passivation layer used to avoid leakage and electrochemical reactions. In this article we report on the semiconductor unit, showing that the device can be operated in a light-assisted mode, where changes in the pH produce changes on the measured ac photocurrent. In alternative the device can be operated as a conventional ion selective field effect device where changes in the pH induce changes in the transistor's threshold voltage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A newly developed solid-state repetitive high-voltage (HV) pulse modulator topology created from the mature concept of the d.c. voltage multiplier (VM) is described. The proposed circuit is based in a voltage multiplier type circuit, where a number of d.c. capacitors share a common connection with different voltage rating in each one. Hence, besides the standard VM rectifier and coupling diodes, two solid-state on/off switches are used, in each stage, to switch from the typical charging VM mode to a pulse mode with the d.c. capacitors connected in series with the load. Due to the on/off semiconductor configuration, in half-bridge structures, the maximum voltage blocked by each one is the d.c. capacitor voltage in each stage. A 2 kV prototype is described and the results are compared with PSPICE simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The benefits of cardiac resynchronization therapy (CRT) in the health-related quality of life (HRQL) are largely demonstrated in selected patients with severe congestive heart failure (CHF). However, the differences between responders and non-responders, with regard to the effect of CRT in the various dimensions that constitute HRQL are still a matter of discussion. Objective: To evaluate the impact of CRT on the HRQL of patients with CHF refractory to optimal pharmacological therapy, within 6 months after CRT. Methods: 43 patients, submitted to successful implantation of CRT, were evaluated in hospital just before intervention and in the outpatient clinic within 6 months after CRT. HRQL was analyzed based on the Kansas City Cardiomyopathy Questionnaire (KCCQ). Patients were classified as super-responders (ejection fraction of left ventricle - LVEF - ≥45% post-CRT), n=15, responders (sustained improvement in functional class and LVEF increased by 15%), n=19, and non-responders (no clinical or LVEF improvement), n=9. Results: In the group of super-responders, CRT was associated with an improvement in HRQL for the various fields and sums assessed (ρ<0.05); in responders, CRT has been associated with an improvement of HRQL in the various fields and sums, except in the self-efficacy dimension (ρ<0.05); in non-responders, CRT was not associated with improvement of HRQL. Conclusion: In a population with severe CHF undergoing CRT, the patients with clinical and echocardiographic positive response, obtained a favorable impact in all dimensions of HRQL, while the group without response to CRT showed no improvement. These data reinforces the importance of HRQL as a multidimensional tool for assessment of benefits in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The benefits of cardiac resynchronization therapy (CRT) in the quality of life have been largely demonstrated in selected patients with severe congestive heart failure (CHF). However, the differences between responders and non-responders, with regard to the effect of CRT in the various dimensions of quality of life is still a matter of discussion. Objective: to evaluate the impact of CRT on the quality of life of patients with CHF refractory to optimal pharmacological therapy, within 6 months after CRT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho teve como principal objectivo o desenvolvimento de um analisador de vibrações de dois canais baseado em computador, para a realização de diagnóstico no âmbito do controlo de condição de máquinas. Foi desenvolvida uma aplicação num computador comum, no software LabVIEW, que através de transdutores de aceleração do tipo MEMS conectados via USB, faz a recolha de dados de vibração e procede ao seu processamento e apresentação ao utilizador. As ferramentas utilizadas para o processamento de dados são ferramentas comuns encontradas em vários analisadores de vibrações disponíveis no mercado. Estas podem ser: gráficos de espectro de frequência, sinal no tempo, cascata ou valores de nível global de vibração, entre outras. Apesar do analisador desenvolvido não apresentar inovação nas ferramentas de análise adoptadas, este pretende ser distinguido pelo baixo custo, simplicidade e carácter didáctico. Este trabalho vem evidenciar as vantagens, desvantagens e potencialidades de um analisador desta natureza. São tiradas algumas conclusões quanto à sua capacidade de diagnóstico de avarias, capacidades como ferramenta didáctica, sensores utilizados e linguagem de programação escolhida. Como conclusões principais, o trabalho revela que os sensores escolhidos não são os indicados para efectuar o diagnóstico de avarias em ambiente industrial, contudo são ideais para tornar este analisador numa boa ferramenta didáctica e de treino.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta tese tem como principal objectivo a investigação teórica e experimental do desempenho de um sensor polarimétrico baseado num cristal líquido para medição da concentração de glicose. Recentemente uma série de sensores polarimétricos baseados em cristais líquidos foram propostos na literatura e receberam considerável interesse devido as suas características únicas. De facto, em comparação com outros moduladores electro-ópticos, o cristal líquido funciona com tensões mais baixas, tem baixo consumo de energia e maior ângulo de rotação. Além disso, este tipo de polarímetro pode ter pequenas dimensões que é uma característica interessante para dispositivos portáteis e compactos. Existem por outro lado algumas desvantagens, nomeadamente o facto do desempenho do polarímetro ser fortemente dependente do tipo de cristal líquido e da tensão a ele aplicada o que coloca desafios na escolha dos parâmetros óptimos de operação. Esta tese descreve o desenvolvimento do sensor polarimétrico, incluindo a integração dos componentes de óptica e electrónica, os algoritmos de processamento de sinal e um interface gráfico que facilita a programação de diversos parâmetros de operação e a calibração do sensor. Após a optimização dos parâmetros de operação verificou-se que o dispositivo mede a concentração da glicose em amostras com uma concentração de 8 mg/ml, com uma percentagem de erro inferior a 6% e um desvio padrão de 0,008o. Os resultados foram obtidos para uma amostra com percurso óptico de apenas 1 cm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reactions of [ReCl2{eta(2)-N2C(O)Ph}(PPh3)(2)](1) with 2-aminopyrimidine (H(2)Npyrm), 2,2'-bipyridine (bpy) and tetraethylthiuram disulfide (tds), in MeOH upon reflux, lead to the new eta(1)-(benzoyldiazenido)-rhenium(III) complexes [ReCl{eta(1)-N2C(O)Ph}(HNpyrm)(PPh3)(2)](2)and [ReCl2{eta(1)-N2C(O)Ph}(bpy)(PPh3)] (3), and the known oxo(diethyldithiocarbamato)dirhenium(v)complex [Re2O2(mu O){Et2NC(S)S}(4)](4), respectively. The Et2NC(S)S ligands in 4 result from S-S bond rupture of tds molecules. The obtained compounds have been characterized by IR, H-1, P-31{H-1} and C-13{H-1} NMR spectroscopies, FAB(+)-MS, elemental and single-crystal X-ray diffraction (for 2 and 4)analyses. Complex 2 represents the first structurally characterized Re compound derived from 2-aminopyrimidine. Besides, the redox behaviour of 2-4 in CH2Cl2 solution has been studied by cyclic voltammetry, and the Lever electrochemical ligand parameter (E-L)has been estimated, for the first time, for HNpyrm. The electrochemical results are discussed in terms of electronic properties of the Re centres and the ligands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent works large area hydrogenated amorphous silicon p-i-n structures with low conductivity doped layers were proposed as single element image sensors. The working principle of this type of sensor is based on the modulation, by the local illumination conditions, of the photocurrent generated by a light beam scanning the active area of the device. In order to evaluate the sensor capabilities is necessary to perform a response time characterization. This work focuses on the transient response of such sensor and on the influence of the carbon contents of the doped layers. In order to evaluate the response time a set of devices with different percentage of carbon incorporation in the doped layers is analyzed by measuring the scanner-induced photocurrent under different bias conditions.