956 resultados para Stereoscopic Display


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The channelled spectrum of an optical beam generated by a laser diode operated below threshold after traversing microscope glass plates is spectrally analysed using a grating and a CCD linear array. The experiment has the following goals: to display the resulting channelled spectrum, to familiarize students with an important topic in metrology and to illustrate some interesting topics from spectroscopy using a CCD array as a spectrometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Saturation mutagenesis is a powerful tool in modern protein engineering. This can allow the analysis of potential new properties thus allowing key residues within a protein to be targeted and randomised. However, the creation of large libraries using conventional saturation mutagenesis with degenerate codons (NNN or NNK) has inherent redundancy and disparities in residue representation. In this we describe the combination of ProxiMAX randomisation and CIS display for the use of generating novel peptides. Unlike other methods ProxiMAX randomisation does not require any intricate chemistry but simply utilises synthetic DNA and molecular biology techniques. Designed ‘MAX’ oligonucleotides were ligated, amplified and digested in an iterative cycle. Results show that randomised ‘MAX’ codons can be added sequentially to the base sequence creating a series of randomised non-degenerate codons that can subsequently be inserted into a gene. CIS display (Isogencia, UK) is an in vitro DNA based screening method that creates a genotype to phenotype link between a peptide and the nucleic acid that encodes it. The use of straight forward in vitro transcription/translation and other molecular biology techniques permits ease of use along with flexibility making it a potent screening technique. Using ProxiMAX randomisation in combination with CIS display, the aim is to produce randomised anti-nerve growth factor (NGF) and calcitonin gene-related (CGRP) peptides to demonstrate the high-throughput nature of this combination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The channelled spectrum of an optical beam generated by a laser diode operated below threshold after traversing microscope glass plates is spectrally analysed using a grating and a CCD linear array. The experiment has the following goals: to display the resulting channelled spectrum, to familiarize students with an important topic in metrology and to illustrate some interesting topics from spectroscopy using a CCD array as a spectrometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: Purpose. Virtual reality devices, including virtual reality head-mounted displays, are becoming increasingly accessible to the general public as technological advances lead to reduced costs. However, there are numerous reports that adverse effects such as ocular discomfort and headache are associated with these devices. To investigate these adverse effects, questionnaires that have been specifically designed for other purposes such as investigating motion sickness have often been used. The primary purpose of this study was to develop a standard questionnaire for use in investigating symptoms that result from virtual reality viewing. In addition, symptom duration and whether priming subjects elevates symptom ratings were also investigated. Methods. A list of the most frequently reported symptoms following virtual reality viewing was determined from previously published studies and used as the basis for a pilot questionnaire. The pilot questionnaire, which consisted of 12 nonocular and 11 ocular symptoms, was administered to two groups of eight subjects. One group was primed by having them complete the questionnaire before immersion; the other group completed the questionnaire postviewing only. Postviewing testing was carried out immediately after viewing and then at 2-min intervals for a further 10 min. Results. Priming subjects did not elevate symptom ratings; therefore, the data were pooled and 16 symptoms were found to increase significantly. The majority of symptoms dissipated rapidly, within 6 min after viewing. Frequency of endorsement data showed that approximately half of the symptoms on the pilot questionnaire could be discarded because <20% of subjects experienced them. Conclusions. Symptom questionnaires to investigate virtual reality viewing can be administered before viewing, without biasing the findings, allowing calculation of the amount of change from pre- to postviewing. However, symptoms dissipate rapidly and assessment of symptoms needs to occur in the first 5 min postviewing. Thirteen symptom questions, eight nonocular and five ocular, were determined to be useful for a questionnaire specifically related to virtual reality viewing using a head-mounted display.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been an increasing interest in the use of agent-based simulation and some discussion of the relative merits of this approach as compared to discrete-event simulation. There are differing views on whether an agent-based simulation offers capabilities that discrete-event cannot provide or whether all agent-based applications can at least in theory be undertaken using a discrete-event approach. This paper presents a simple agent-based NetLogo model and corresponding discrete-event versions implemented in the widely used ARENA software. The two versions of the discrete-event model presented use a traditional process flow approach normally adopted in discrete-event simulation software and also an agent-based approach to the model build. In addition a real-time spatial visual display facility is provided using a spreadsheet platform controlled by VBA code embedded within the ARENA model. Initial findings from this investigation are that discrete-event simulation can indeed be used to implement agent-based models and with suitable integration elements such as VBA provide the spatial displays associated with agent-based software.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Saturation mutagenesis is a powerful tool in modern protein engineering, which permits key residues within a protein to be targeted in order to potentially enhance specific functionalities. However, the creation of large libraries using conventional saturation mutagenesis with degenerate codons (NNN or NNK/S) has inherent redundancy and consequent disparities in codon representation. Therefore, both chemical (trinucleotide phosphoramidites) and biological methods (sequential, enzymatic single codon additions) of non-degenerate saturation mutagenesis have been developed in order to combat these issues and so improve library quality. Large libraries with multiple saturated positions can be limited by the method used to screen them. Although the traditional screening method of choice, cell-dependent methods, such as phage display, are limited by the need for transformation. A number of cell-free screening methods, such as CIS display, which link the screened phenotype with the encoded genotype, have the capability of screening libraries with up to 1014 members. This thesis describes the further development of ProxiMAX technology to reduce library codon bias and its integration with CIS display to screen the resulting library. Synthetic MAX oligonucleotides are ligated to an acceptor base sequence, amplified, and digested, subsequently adding a randomised codon to the acceptor, which forms an iterative cycle using the digested product of the previous cycle as the base sequence for the next. Initial use of ProxiMAX highlighted areas of the process where changes could be implemented in order to improve the codon representation in the final library. The refined process was used to construct a monomeric anti-NGF peptide library, based on two proprietary dimeric peptides (Isogenica) that bind NGF. The resulting library showed greatly improved codon representation that equated to a theoretical diversity of ~69%. The library was subsequently screened using CIS display and the discovered peptides assessed for NGF-TrkA inhibition by ELISA. Despite binding to TrkA, these peptides showed lower levels of inhibition of the NGF-TrkA interaction than the parental dimeric peptides, highlighting the importance of dimerization for inhibition of NGF-TrkA binding.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the introduction of new input devices, such as multi-touch surface displays, the Nintendo WiiMote, the Microsoft Kinect, and the Leap Motion sensor, among others, the field of Human-Computer Interaction (HCI) finds itself at an important crossroads that requires solving new challenges. Given the amount of three-dimensional (3D) data available today, 3D navigation plays an important role in 3D User Interfaces (3DUI). This dissertation deals with multi-touch, 3D navigation, and how users can explore 3D virtual worlds using a multi-touch, non-stereo, desktop display. ^ The contributions of this dissertation include a feature-extraction algorithm for multi-touch displays (FETOUCH), a multi-touch and gyroscope interaction technique (GyroTouch), a theoretical model for multi-touch interaction using high-level Petri Nets (PeNTa), an algorithm to resolve ambiguities in the multi-touch gesture classification process (Yield), a proposed technique for navigational experiments (FaNS), a proposed gesture (Hold-and-Roll), and an experiment prototype for 3D navigation (3DNav). The verification experiment for 3DNav was conducted with 30 human-subjects of both genders. The experiment used the 3DNav prototype to present a pseudo-universe, where each user was required to find five objects using the multi-touch display and five objects using a game controller (GamePad). For the multi-touch display, 3DNav used a commercial library called GestureWorks in conjunction with Yield to resolve the ambiguity posed by the multiplicity of gestures reported by the initial classification. The experiment compared both devices. The task completion time with multi-touch was slightly shorter, but the difference was not statistically significant. The design of experiment also included an equation that determined the level of video game console expertise of the subjects, which was used to break down users into two groups: casual users and experienced users. The study found that experienced gamers performed significantly faster with the GamePad than casual users. When looking at the groups separately, casual gamers performed significantly better using the multi-touch display, compared to the GamePad. Additional results are found in this dissertation.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Il progetto di tesi è stato sviluppato durante il tirocinio, in collaborazione con Tipolito Salvioli e Kina Studio. Si tratta di un sistema espositivo per la linea di prodotti cartacei LovePaper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

General note: Title and date provided by Bettye Lane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

General note: Title and date provided by Bettye Lane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

General note: Title and date provided by Bettye Lane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation models a new approach to the study of ancient portrait statues—one that situates them in their historical, political, and spatial contexts. By bringing into conversation bodies of evidence that have traditionally been studied in discrete categories, I investigate how statue landscapes articulated and reinforced a complex set of political and social identities, how space was utilized and manipulated on a local and a regional level, and how patrons responded to the spatial pressures and visual politics of statue dedication within a constantly changing landscape.

Instead of treating sites independently, I have found it to be more productive—and, indeed, necessary—to examine broader patterns of statue dedication. I demonstrate that a regional perspective, that is, one that takes into account the role of choice and spatial preference in setting up a statue within a regional network of available display locations, can illuminate how space shaped the ancient practice of portrait dedication. This level of analysis is a new approach to the study of portrait statues and it has proved to be a productive way of thinking about how statues and context were used together to articulate identity. Understanding how individual monuments worked within these broader landscapes of portrait dedications, how statue monuments functioned within federal systems, and how monuments set up by individuals and social groups operated along side those set up by political bodies clarifies the important place of honorific statues as an expression of power and identity within the history of the site, the region, and Hellenistic Greece.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Minimally-invasive microsurgery has resulted in improved outcomes for patients. However, operating through a microscope limits depth perception and fixes the visual perspective, which result in a steep learning curve to achieve microsurgical proficiency. We introduce a surgical imaging system employing four-dimensional (live volumetric imaging through time) microscope-integrated optical coherence tomography (4D MIOCT) capable of imaging at up to 10 volumes per second to visualize human microsurgery. A custom stereoscopic heads-up display provides real-time interactive volumetric feedback to the surgeon. We report that 4D MIOCT enhanced suturing accuracy and control of instrument positioning in mock surgical trials involving 17 ophthalmic surgeons. Additionally, 4D MIOCT imaging was performed in 48 human eye surgeries and was demonstrated to successfully visualize the pathology of interest in concordance with preoperative diagnosis in 93% of retinal surgeries and the surgical site of interest in 100% of anterior segment surgeries. In vivo 4D MIOCT imaging revealed sub-surface pathologic structures and instrument-induced lesions that were invisible through the operating microscope during standard surgical maneuvers. In select cases, 4D MIOCT guidance was necessary to resolve such lesions and prevent post-operative complications. Our novel surgical visualization platform achieves surgeon-interactive 4D visualization of live surgery which could expand the surgeon's capabilities.