687 resultados para Stainless steels


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento (Programa doutoral em Engenharia de Materiais)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PhD in Sciences Specialty in Physics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: We determined the effects of losartan and PD 123319 (antagonists of the AT1 and AT2 angiotensin receptors, respectively), and [Sar¹, Ala8] ANG II (a relatively peptide antagonist of angiotensin receptors) injected into the paraventricular nucleus (PVN) on water and 3% NaCl intake, and the diuretic, natriuretic, and pressor effects induced by administration of angiotensin II (ANG II) into the medial septal area (MSA) of conscious rats. METHODS: Holtzman rats were used . Animals were anesthetized with tribromoethanol (20 mg) per 100 grams of body weight, ip. A stainless steel guide cannula was implanted into the MSA and PVN. All drugs were injected in 0.5-mul volumes for 10-15 seconds. Seven days after brain surgery, water and 3% NaCl intake, urine and sodium excretion, and arterial blood pressure were measured. RESULTS: Losartan (40 nmol) and [Sar¹, Ala8] ANG II (40 nmol) completely eliminated whereas PD 123319 (40 nmol) partially blocked the increase in water and sodium intake and the increase in arterial blood pressure induced by ANG II (10 nmol) injected into the MSA. The PVN administration of PD 123319 and [Sar¹, Ala8] ANG II blocked whereas losartan attenuated the diuresis and natriuresis induced by MSA administration of ANG II. CONCLUSION: MSA involvement with PVN on water and sodium homeostasis and arterial pressure modulation utilizing ANGII receptors is suggested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of chemistry and soaking temperature (maximal temperature of the continuous annealing) on the final properties of non-oriented electrical steels has been studied. With this objective two different studies have been performed. First the Mn, Ni and Cr content of a low loss electrical steel composition has been modified. An intermediate content and a high content of each element has been added in order to study the influence of this components on the magnetic looses, grain size and texture. Secondly the influence of the soaking temperature on magnetic properties, grain size and oxidation in four grades of non-oriented electrical steels (Steel A, B, C and D) was studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En aquest projecte es presenta un estudi sobre punxonats i esbocats per a materials d’Alt límit elàstic (Acers AHSS; Advanced High Strength Steels), amb l’objectiu d’aconseguir saber quin és el millor procés de tall per aconseguir esbocats correctes. Utilitzant la premsa hidràulica de la Fundació Centre Tecnològic de Manresa (CTM) es realitza el punxonat i els esbocats a tots els materials per tal d’avaluar el seu comportament alhora de ser esbocats. A partir d’aquests resultats obtindrem les gràfiques de ràtio d’esbocat per a cadascun dels materials en els diferents sentits de esbocat. Com a mètode alternatiu del procés de tall, es realitzen unes mostres amb tall per aigua. S’observarà si els esbocats trenquen o no trenquen i en quines condicions ho fan. Una vegada realitzats aquests assajos, es procedirà a realitzar l’estudi de microdureses amb un indentador Vickers per tal de comprovar l’afectació de l’operació de tall en la microestructura del material. Es realitzarà també algun perfil de dureses utilitzant el Nanoindentador. Per finalitzar el projecte, s’inclourà un apartat de conclusions i un estudi mediambiental produït com a conseqüència de l’elaboració del projecte, així com un pressupost total d’aquest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El estudio desarrollado en la tesis doctoral profundiza en las relaciones existentes entre la microestructura y el comportamiento a rotura y fatiga de tres tipos de Aceros de Herramienta para trabajo en Frío, dos obtenidos por colada y un tercero mediante pulvimetalúrgia. En primer lugar se evaluaron los aspectos microestructurales relacionados con las dos vias de procesamiento empleadas, además del efecto del cambio en la composición química. Asimismo se documentó la influencia del trabajado en caliente sobre la isotropía microestructural. Considerando las caracteristicas microestructurales se evaluó el comportamiento a rotura en tres orientaciones referidas al sentido de la deformación en caliente. Para ello , se empleó la Mecánica de la Fractura Elástica Lineal como marco analítico. Los resultados fueron tratados siguiendo la estadística de Weibull. Para el caso de los aceros colados se implementa un analisis de curva-R para explicar el crecimiento subcrítico de grietas observado experimentalmente. El estudio del comportamiento a fatiga incluyó la determinación del limite a fatiga para todas la orientaciones microestructurales escogidas y el estudio de la cinetica de propagación de fisuras físicamente pequeñas para la orientación con mejor respuesta mecánica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple wipe sampling procedure was developed for the surface contamination determination of ten cytotoxic drugs: cytarabine, gemcitabine, methotrexate, etoposide phosphate, cyclophosphamide, ifosfamide, irinotecan, doxorubicin, epirubicin and vincristine. Wiping was performed using Whatman filter paper on different surfaces such as stainless steel, polypropylene, polystyrol, glass, latex gloves, computer mouse and coated paperboard. Wiping and desorption procedures were investigated: The same solution containing 20% acetonitrile and 0.1% formic acid in water gave the best results. After ultrasonic desorption and then centrifugation, samples were analysed by a validated liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in selected reaction monitoring mode. The whole analytical strategy from wipe sampling to LC-MS/MS analysis was evaluated to determine quantitative performance. The lowest limit of quantification of 10 ng per wiping sample (i.e. 0.1 ng cm(-2)) was determined for the ten investigated cytotoxic drugs. Relative standard deviation for intermediate precision was always inferior to 20%. As recovery was dependent on the tested surface for each drug, a correction factor was determined and applied for real samples. The method was then successfully applied at the cytotoxic production unit of the Geneva University Hospitals pharmacy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Of the approximately 25,000 bridges in Iowa, 28% are classified as structurally deficient, functionally obsolete, or both. Because many Iowa bridges require repair or replacement with a relatively limited funding base, there is a need to develop new bridge materials that may lead to longer life spans and reduced life-cycle costs. In addition, new and effective methods for determining the condition of structures are needed to identify when the useful life has expired or other maintenance is needed. Due to its unique alloy blend, high-performance steel (HPS) has been shown to have improved weldability, weathering capabilities, and fracture toughness than conventional structural steels. Since the development of HPS in the mid-1990s, numerous bridges using HPS girders have been constructed, and many have been economically built. The East 12th Street Bridge, which replaced a deteriorated box girder bridge, is Iowa’s first bridge constructed using HPS girders. The new structure is a two-span bridge that crosses I-235 in Des Moines, Iowa, providing one lane of traffic in each direction. A remote, continuous, fiber-optic based structural health monitoring (SHM) system for the bridge was developed using off-the-shelf technologies. In the system, sensors strategically located on the bridge collect raw strain data and then transfer the data via wireless communication to a gateway system at a nearby secure facility. The data are integrated and converted to text files before being uploaded automatically to a website that provides live strain data and a live video stream. A data storage/processing system at the Bridge Engineering Center in Ames, Iowa, permanently stores and processes the data files. Several processes are performed to check the overall system’s operation, eliminate temperature effects from the complete strain record, compute the global behavior of the bridge, and count strain cycles at the various sensor locations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The NALP3 inflammasome functions as a sensor of danger signals and triggers processing and release of IL-1b. Mutations of NALP3 are responsible for the cryopyrin associated periodic syndromes, a group of autoinflammatory disorders that respond to IL1 inhibition. Genetic studies have also linked NALP3 to hypertension in man, but the mechanism is not understood. The aim of this study is to investigate the role of NAPL3 inflammasome in the development of hypertension in an animal model. Design and Method: Six-week old male WT and NALP3 KO mice were used for generating a two-kidney, one clip (2K1C) renovascular hypertension. A U-shaped stainless steel clip (O^ ¼0.12mm) was placed on left renal artery under anaesthesia. The same surgery without clipping was performed in sham mice. At week 6 and 12 after the clipping, intra-arterial blood pressure (BP) was measured in conscious mice. Blood was collected for plasma renin analysis. Heart and kidney were excised and stored for molecular and morphological examinations. n¼5-6 mice per group. Data are mean_SEM. Results: Mean BP was significantly increased at week 6 and 12 in WT-2K1C mice compared to WT-sham group (MBPweek6: 138_2 vs.124_3 mmHg, p<0.01 and MBPweek12: 141_5 vs.122_3 mmHg, p<0.01) followed with an significant increase in heart weight (HW) and a decrease in clipped kidney weight indices in WT-2K1C mice compared to the WT-sham (HW/ BWweek6: 4.65_0.04 vs. 3.99_0.12 mg/g, p<0.001 and HW/BWweek12: 4.94_0.15 vs. 4.22_0.12 mg/g, p<0.001). Interestingly, NALP3 KO-2K1C mice did not develop hypertension. The MBP of KO-2K1C mice was comparable to the KO-sham (MBPweek6: 122_3 vs. 119_3 mmHg, p>0.05 and MBPweek6: 128_5 vs.122_4 mmHg, p>0.05). There was also no significant change in heart and kidney weight indices between KO- 2K1C and KO-sham mice. Conclusion: The preliminary results suggest that absence of NALP3 protects mice from the development of renin-dependent hypertension. Further molecular and morphological examinations are ongoing for the confirmation and mechanism explanation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les empreses sempre han buscat com optimitzar el màxim els seus recursos i ser més eficients a la hora de realitzar les tasques que li han estat encomanades. És per aquest motiu que constantment les empreses realitzen estudis i valoracions de com poder millorar dia a dia. Aquest fet no és diferenciador a l’empresa Serralleria i Alumini Vilaró (S.A.V), que dia a dia estudia com optimitzar els seus processos o de vegades introduir-ne de nous per tal d’expandir la seva oferta de serveis. L’empresa és dedica a la fabricació de peces metàl•liques el procés ja sigui només de tall i mecanitzat, plegat, soldadura, acabats en inoxidable, pintura i fins i tot embalatge pel que fa a la part productiva, respecte a la part d’oficina tècnica també ofereix serveis de desenvolupament de productes segons especificacions del client i reenginyeria de qualsevol producte, analitzant la part que és vol millorar. En l’actualitat l’empresa ha detectat una mancança que creu que es podria solucionar, el problema és que l’empresa disposa de varies màquines de tall, entre les quals hi ha una màquina de tall làser i el problema principal és que la càrrega de les planxes del calaix de magatzem a la bancada de la màquina es realitza o bé manualment o a través d’un gripper sostingut al pont grua, depenent del pes de la planxa a transportar. L’objectiu principal d’aquest treball és fer el disseny d’una màquina que permeti automatitzar el procés de transportar la planxa metàl•lica del calaix de magatzem dipositat sobre una taula mòbil a la bancada de la màquina de tall. El disseny que pretenem fer és complet començant per fer un disseny estructural de la màquina més els seus respectius càlculs, moviments que volem aconseguir, tria de components ( motors, sensors ...), elaboració d’un pressupost per poder fer una estimació i finalment la elaboració del programa de control de tota la màquina més la interacció amb la màquina a través d’una pantalla tàctil. Es a dir, el que pretenem és realitzar un projecte que puguem fabricar en la realitat utilitzant tota la informació continguda dins del mateix

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present structural and electrical properties for p- and n-type layers grown close to the transition between a-Si:H and nc-Si:H onto different substrates: Corning 1737 glass, ZnO:Al-coated glass and stainless steel. Structural properties were observed to depend on the substrate properties for samples grown under the same deposition conditions. Different behaviour was observed for n- and p-type material. Stainless steel seemed to enhance crystallinity when dealing with n-type layers, whereas an increased crystalline fraction was obtained on glass for p-type samples. Electrical conduction in the direction perpendicular to the substrate seemed to be mainly determined by the interfaces or by the existence of an amorphous incubation layer that might determine the electrical behaviour. In the direction perpendicular to the substrate, n-type layers exhibited a lower resistance value than p-type ones, showing better contact properties between the layer and the substrate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A radiochemical procedure was developed for the sequential determination of Pu and Am radioisotopes in environmental samples. The radioisotope activities were then used to assess the origin and release date of the environmental plutonium. The radioanalytical procedure is based on the separation of Pu and Am on selective extraction chromatographic resins (Eichrom TEVA and DGA). Alpha sources were prepared by electrodeposition on stainless steel discs, and the alpha emitting radionuclides (238Pu, 239,240Pu and 241Am) were measured by alpha spectrometry. For the determination of the beta emitting 241Pu, the Pu alpha source was leached in hot concentrated nitric acid and the Pu fraction further purified by extraction chromatography on a small column of TEVA resin (100 μg of resin in a pipette tip). 241Pu is then measured by ultra low level liquid scintillation counting. Due to the lack of reference material for 241Pu, the proposed radiochemical method was nevertheless validated using four IAEA reference sediments with information values of 241Pu. The proposed method was then used to determine the 238Pu, 239,240Pu, 241Pu and 241Am activity concentrations in alpine soils of France and Switzerland. The soil is the primary receptor of the atmospheric radioactive fallout and, because of the strong binding interaction with soils particles, the isotopes are little fractionated. Therefore, the activity ratios 241Pu/239+240Pu and 238Pu/239,240Pu in soil samples were used to determine the origin (source) and date of the Pu contamination in the investigated alpine sites. The 241Pu/239,240Pu and 238Pu/239,240Pu activity ratios confirmed that the main origin of Pu in the alpine soils was the global fallout from the nuclear bomb tests (NBT) in the fifties and sixties. Furthermore, the 241Pu/241Am activity ratios were used to determine the age of the Pu contamination, which is also an important data for distinguishing the Pu sources. The estimation of the date of the contamination, by the 241Pu/241Am age-dating method, further confirmed the NBT as the Pu source. However, the 241Pu/241Am dating method was limited to samples where Pu-Am fractionation was insignificant. If any, the contribution of the Chernobyl accident in the studied sites is negligible.