998 resultados para Single Crossing Property Marginal Rate of Substitution IdentityDiscrete Pooling.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Angiotensin II (Ang II) non-peptide antagonists were injected i.c.v. (6.25-200 nmol, n = 5-8 rats/group): In sodium replete rats, losartan (AT1 receptor antagonist) induced an increase in mean arterial pressure (MAP) and in heart rate (HR) by 3rd ventricular (3rdV) injection, and a weaker pressor response and bradycardia by 4th ventricular (4thV) injection. PD123319 (AT2 receptor antagonist) induced an increase in MAP and in HR by 3rdV injection, and an increase in MAP and no alteration in HR by 4thV injection. In sodium deplete (furosemide plus removal of ambient sodium for 24 h) rats, losartan induced an increase in MAP and no alteration in HR by 3rdV injection, and no alteration in MAP and bradycardia by 4thV injection. PD123319 induced an increase in MAP and in HR by 3rdV injection, and an increase in MAP and bradycardia by 4thV injection. Thus, there was no fall in MAP by central injections of Ang II antagonists. Intravenous injection of losartan, but not of PD123319, induced a fall in MAP in both sodium replete and sodium deplete animals. Therefore, losartan and PD123319 can have similar effects on MAP and HR when injected intracerebroventricularly, although some differences are also present. The bradycardia is consistent with an withdrawal of Ang II inhibitory action on baroreflex.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The growth rate of mounds of Nasutitermes sp. was evaluated by taking monthly measurements of the diameter and the height of ten mounds during twelve months. Through these data, the monthly volumes were calculated for each of them and, later, a dispersion diagram between the volume of each mound and the number of days from the first observation was obtained. From this diagram, it was observed that during the 335 days of observation, the rate of growth of these mounds was null.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Despite careful procedures, master stone dies may be damaged during laboratory procedures. The dentist routinely adjusts castings because the marginal fit of casting is not as accurate as on the dies. PURPOSE: This study evaluated the technique of internal adjustment of castings with use of duplicated stone dies and a disclosing agent to improve marginal fit discrepancy. MATERIAL AND METHODS: Thirty-two nickel-chromium copings were fabricated and simulated standard clinical and laboratory procedures with 2 variables: tooth preparation convergence angles of 6 and 18 degrees, with or without internal relief. Master stone dies and their duplicates were selected for coping construction and internal adjustment, respectively. A specimen positioning device was coupled with a Toolmakers microscope to allow reproducibility of measurements. Each coping was evaluated at 8 locations of its marginal perimeter, before and after internal adjustment. RESULTS: Marginal fit discrepancy of copings were significantly reduced with an internal adjustment technique (mean > 52%) for all experimental groups. Tooth preparations with greater convergence and internally relieved castings recorded a better marginal fit. CONCLUSION: The casting internal adjustment technique with use of duplicated stone dies and a disclosing agent substantially reduced marginal fit discrepancy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Curcuma longa L. is used in many countries for its flavor, and medicinal and cosmetic attributes, as well as for its peculiar starch characteristics. These factors have driven an interest in the in vitro propagation of this species, looking for germplasm bank maintenance, production of disease free plants, genetic variability induction from callus, and as a tool for starch research. However, there are few reports concerning the micropropagation of Curcuma longa. The in vitro propagation rate of this species, cultured under two benzylaminopurine (BAP) concentrations, was the aim of this research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bit performance prediction has been a challenging problem for the petroleum industry. It is essential in cost reduction associated with well planning and drilling performance prediction, especially when rigs leasing rates tend to follow the projects-demand and barrel-price rises. A methodology to model and predict one of the drilling bit performance evaluator, the Rate of Penetration (ROP), is presented herein. As the parameters affecting the ROP are complex and their relationship not easily modeled, the application of a Neural Network is suggested. In the present work, a dynamic neural network, based on the Auto-Regressive with Extra Input Signals model, or ARX model, is used to approach the ROP modeling problem. The network was applied to a real oil offshore field data set, consisted of information from seven wells drilled with an equal-diameter bit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of cavity design and photocuring method on the marginal seal of resin composite restorations. METHOD AND MATERIALS: Seventy-two bovine teeth were divided into 2 groups: group 1 received box-type cavity preparations, and group 2 received plate-type preparations. Each group was divided into 3 subgroups. After etching and bonding, Z250 resin composite (3M Espe) was applied in 2 equal increments and cured with 1 of 3 techniques: (1) conventional curing for 30 seconds at 650 mW/cm2; (2) 2-step photocuring, in which the first step was performed 14 mm from the restoration for 10 seconds at 180 mW/cm2 and the second step was performed in direct contact for 20 seconds at 650 mW/cm2; or (3) progressive curing using Jetlite 4000 (J. Morita) for 8 seconds at 125 mW/cm2 and then 22 seconds at 125 mW/cm2 up to 500 mW/cm2. The specimens were thermocycled for 500 cycles and then submitted to dye penetration with a 50% silver nitrate solution. Microleakage was assessed using a stereomicroscope. Data were analyzed using analysis of variance and Tukey test (5% level of significance). RESULTS: A statistically significant difference was found between groups when a double interaction between photocuring and cavity preparation was considered (P = .029). CONCLUSIONS: No one type of cavity preparation or photocuring method prevented micro-leakage. The plate-type preparation showed the worst dye penetration when conventional and progressive photocuring methods were used. The best results were found using the 2-step photocuring with the plate-type preparation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This study assessed the effect of cast rectifiers on the marginal misfit of cast UCLA abutments compared to premachined UCLA abutments. The influence of casting and porcelain baking on the marginal misfit of these components was also investigated. Methods: Two groups were analyzed: test group - 10 cast UCLA abutments, finished with cast rectifier and submitted to ceramic application; control group - 10 premachined UCLA abutments, cast with noble metal alloy and submitted to ceramic application. Vertical misfit measurements were performed under light microscopy. In the test group, measurements were performed before and after the use of cast rectifiers, and after ceramic application. In the control group, measurements were performed before and after casting, and after ceramic application. Data were submitted to statistical analysis by ANOVA and Tukey's test (α= 5%). Results: The use of cast rectifiers significantly reduced the marginal misfit of cast UCLA abutments (from 25.68μm to 14.83μm; p<0.05). After ceramic application, the rectified cylinders presented misfit values (16.18μm) similar to those of premachined components (14.3 μm). Casting of the premachined UCLA abutments altered the marginal misfit of these components (from 9.63 μm to 14.6 μm; p<0.05). There were no significant changes after porcelain baking, in both groups. Conclusion: The use of cast rectifiers reduced the vertical misfit of cast UCLA abutments. Even with carefully performed laboratory steps, changes at the implant interface of premachined UCLA abutments occurred. Ceramic application did not alter the marginal misfit values of UCLA abutments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The maintenance and stability of peri-implantar soft tissue seem to be related to the crestal bone around the implant platform and different implant designs connections might affect this phenomenon. The aim of this study was to evaluate by photoelastic analysis the stress distribution in the cervical and apical site of implant-abutment interface of conventional implant joints (external hex, internal hex and cone morse) and compare to the novel platform switching design. Materials and methods: It was fabricated photoelastic models using five different implant-abutment connection, one set of external hex (Alvim Ti, Neodent, Curitiba, Brazil), one set of internal hex (Full Osseotite, Biomet 3i, Florida, USA), one cone morse set (Alvim CM, Neodent, Curitiba, Brazil), and two sets of internal hex plus platform switching concept (Alvim II Plus, Neodent, Curitiba, Brazil) (Certain Prevail, Biomet 3i, Florida, USA). These models were submitted to two compressive loads, axial from 20 kgf (load I) and another (load II), inclined 45° from 10 kgf. During the qualitative analysis, digital pictures were taken from a polariscope, for each load situation. For the quantitative analyses in both situations of load, the medium, minimum and maximum in MPa values of shear strain were determined in the cervical and apical site. The Kruskal-Wallis test was used to compare the results between the different systems and between cervical and apical site were compared using Mann-Whitney U test. Results: The results from qualitative analysis showed less concentration of strain in the cervical area to the internal hex plus platform switching (Certain Prevail), in both situation of load. The same results were get in the quantitative analysis, showing less stress concentrations around the implant Certain Prevail with internal hex plus the novel design (17.9 MPa to load I and 29.5 MPa to load II), however, without statistical significant difference between the systems. Conclusion: The minor stress concentration strongly suggest the use of platform switching design as a manner to prevent bone loss around the implant-abutment platform. Clinical Significance: From the result of this study its possible to make clinical decision for implant system which provides implant components with platform switching characteristics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate in vivo the failure rate of metallic brackets bonded with two orthodontic composites. Nineteen patients with ages ranging from 10.5 to 38.7 years needing corrective orthodontic treatment were selected for study. The enamel surfaces from second premolars to second premolars were treated with Transbond Plus-Self Etching Primer (3M Unitek). Next, 380 orthodontic brackets were bonded on maxillary and mandibular teeth, as follows: 190 with Transbond XT composite (3M Unitek) (control) and 190 with Transbond Plus Color Change (3M Unitek) (experimental) in contralateral quadrants. The bonded brackets were light cured for 40 s, and initial alignment archwires were inserted. Bond failure rates were recorded over a six-month period. At the end of the evaluation, six bond failures occurred, three for each composite. Kaplan-Meyer method and log-rank test (Mantel-Cox) was used for statistical analysis, and no statistically significant difference was found between the materials (p=0.999). Both Transbond XT and Transbond Plus Color Change composites had low debonding rates over the study period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To evaluate the influence of the width of the buccal bony wall on hard and soft tissue dimensions following implant installation. Material and methods: Mandibular premolars and first molars of six Labrador dogs were extracted bilaterally. After 3 months of healing, two recipient sites, one on each side of the mandible, were prepared in such a way as to obtain a buccal bony ridge width of about 2 mm in the right (control) and 1 mm in the left sides (test), respectively. Implants were installed with the coronal margin flush with the buccal alveolar bony crest. Abutments were placed and the flaps were sutured to allow a non-submerged healing. After 3 months, the animals were euthanized and ground sections obtained. Results: All implants were completely osseointegrated. In respect to the coronal rough margin of the implant, the most coronal bone-to-implant contact was apically located 1.04 ± 0.91 and 0.94 ± 0.87 mm at the test and control sites, respectively, whereas the top of the bony crest was located 0.30 ± 0.40 mm at the test and 0.57 ± 0.49 mm at the control sites. No statistically significant differences were found. A larger horizontal bone resorption, however, evaluated 1 mm apically to the rough margin, was found at the control (1.1 ± 0.7 mm) compared to the test (0.3 ± 0.3 mm) sites, the difference being statistically significant. A thin peri-implant mucosa (2.4-2.6 mm) was found at implant installation while, after 3 months of healing, a biological width of 3.90-4.40 mm was observed with no statistically significant differences between control and test sites. Conclusions: A width of the buccal bony wall of 1or 2 mm at implant sites yielded similar results after 3 months of healing in relation of hard tissue and soft tissues dimensions after implant installation. © 2012 John Wiley & Sons A/S.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Some studies have shown differences in specific cognitive ability domains between the sexes at 60 years-of-age. However is important to analyze whether the rate of cognitive decline is also similar between the sexes after this age. The present study examined previously published literature to investigate whether cognitive decline is distinct between men and women after the age of 60 years. A systematic review was carried out with the PubMed, LILACS and PsycINFO databases (2001-2011) using the following search terms: aging, aged, cognitive function, mild cognitive impairment, mental health and cognition. We analyzed longitudinal research that used neuropsychological tests for evaluating cognitive function, showed results separated by sex and that excluded participants with dementia. Elderly women showed better performance in tests of episodic memory, whereas elderly men had a better visuospatial ability. Only one study detected distinct rates of cognitive decline in specific tests between the sexes. Despite differences observed in some domains, most of the studies showed that this rate is similar between the sexes until the age of 80 years. It is unclear whether sex influences the rate of cognitive decline after the age of 80 years. The present review observed that sex does not determine the rate of cognitive decline between 60 and 80 years-of-age. The contextual and cultural factors that involve men and women might determine a distinct decline between them, rather than sex alone. © 2013 Japan Geriatrics Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examined the effect of fast-velocity concentric isokinetic resistance training (FV) on the rate of force development (RFD) at early (<100 ms) and late phases (>100 ms) of rising muscle force. Nine men participated in a 6-week resistance training intervention for the lower body, and nine matched subjects participated as controls (CON). During concentric isokinetic (180°s-1) knee extension training, subjects were instructed to do each contraction 'as fast and forcefully as possible'. Maximal muscle strength (MVC) and RFD (0-10, 0-20, ..., 0-250 ms from the onset of contraction) were measured during maximal voluntary isometric contraction of the knee extensors (KE). There were no significant changes in MVC of KE in both groups after intervention (FV = 314·2 ± 101·1 versus 338·7 ± 88·0 N{bullet operator}m, P>0·05; CON = 293·3 ± 94·8 versus 280·0 ± 72·2 N{bullet operator}m, P>0·05). The RFD increased 39-71% at time intervals up to 90 ms from the onset of the contraction (P<0·05), whereas no change occurred at later time intervals. Similarly, relative RFD (i.e.%MVC{bullet operator}s-1) (RFDr) increased 33-56% at time intervals up to 70 ms from the onset of the contraction (P<0·05). It can be concluded that a short period of resistance training performed with concentric fast-velocity isokinetic muscle contractions is able to enhance RFD and RFDr obtained at the early phase of rising muscle force. © 2013 The Authors Clinical Physiology and Functional Imaging © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A multiyear solution of the SIRGAS-CON network was used to estimate the strain rates of the earth surface from the changing directions of the velocity vectors of 140 geodetic points located in the South American plate. The strain rate was determined by the finite element method using Delaunay triangulation points that formed sub-networks; each sub-network was considered a solid and homogeneous body. The results showed that strain rates vary along the South American plate and are more significant on the western portion of the plate, as expected, since this region is close to the subduction zone of the Nazca plate beneath the South American plate. After using Euler vectors to infer Nazca plate movement and to orient the velocity vectors of the South American plate, it was possible to estimate the convergence and accommodation rates of the Nazca and South American plates, respectively. Strain rate estimates permitted determination of predominant contraction and/or extension regions and to establish that contraction regions coincide with locations with most of the high magnitude seismic events. Some areas with extension and contraction strains were found to the east within the stable South American plate, which may result from different stresses associated with different geological characteristics. These results suggest that major movements detected on the surface near the Nazca plate occur in regions with more heterogeneous geological structures and multiple rupture events. Most seismic events in the South American plate are concentrated in areas with predominant contraction strain rates oriented northeast-southwest; significant amounts of elastic strain can be accumulated on geological structures away from the plate boundary faults; and, behavior of contractions and extensions is similar to what has been found in seismological studies. © 2013 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)