947 resultados para Scanning acoustic microscope
Resumo:
This thesis presents a comparative developmental study of inflorescences and focuses on the production of the terminal flower (TF). Morphometric attributes of inflorescence meristems (IM) were obtained throughout the ontogeny of inflorescence buds with the aim of describing possible spatial constraints that could explain the failure in developing the TF. The study exposes the inflorescence ontogeny of 20 species from five families of the Eudicots (Berberidaceae, Papaveraceae-Fumarioideae, Rosaceae, Campanulaceae and Apiaceae) in which 745 buds of open (i.e. without TF) and closed (i.e. with TF) inflorescences were observed under the scanning electron microscope.rnThe study shows that TFs appear on IMs which are 2,75 (se = 0,38) times larger than the youngest lateral reproductive primordium. The shape of these IMs is characterized by a leaf arc (phyllotactic attribute) of 91,84° (se = 7,32) and a meristematic elevation of 27,93° (se = 5,42). IMs of open inflorescences show a significant lower relative surface, averaging 1,09 (se=0,26) times the youngest primordium size, which suggests their incapacity for producing TFs. The relative lower size of open IMs is either a condition throughout the complete ontogeny (‘open I’) or a result from the drastic reduction of the meristematic surface after flower segregation (‘open II’). rnIt is concluded that a suitable bulge configuration of the IM is a prerequisite for TF formation. Observations in the TF-facultative species Daucus carota support this view, as the absence of the TF in certain umbellets is correlated with a reduction of their IM dimensions. A review of literature regarding histological development of IMs and genetic regulation of inflorescences suggests that in ‘open I’ inflorescences, the histological composition and molecular activity at the tip of the IM could impede the TF differentiation. On the other side, in ‘open II’ inflorescences, the small final IM bulge could represent a spatial constraint that hinders the differentiation of the TF. The existence of two distinct kinds of ontogenies of open inflorescences suggests two ways in which the loss of the TF could have occurred in the course of evolution.rn
Resumo:
In der vorliegenden Studie wurden verschiedene Techniken eingesetzt um drei Proben (4, 7, and 8) die aus denrnKorrosionsprodukten von aus dem Kosovo Krieg stammenden Munitionskugeln, bestehend aus abgereichertem Uranrn(Depleted Uranium - DU), zu untersuchen. Als erstes Verfahren wurde die Raman-Spektroskopie eingesetzt. Hierbeirnzeigte sichin den Proben, charakterisiert durch einen Doppelpeak, die Anwesenheit von Schoepitrn(UO2)8O2(OH)12(H2O)12. Der erste und zweite Peakzeigte sich im Spektralbereich von 840,3-842,5 cm-1rnbeziehungsweise 853,6-855,8 cm-1. Diese Werte stimmen mit den Literaturwerten für Raman-Peaks für Schoepitrnüberein. Des Weiteren wurde bei dieser Untersuchungsmethode Becquerelite Ca(UO2)6O4(OH)6(H2O)8 mit einemrnPeak im Bereich zwischen 829 to 836 cm-1 gefunden. Aufgrund des Fehlens des Becquerelitespektrums in derrnSpektralbibliothek wurde eine in der Natur vorkommende Variante analysiert und deren Peak bei 829 cm-1 bestimmt,rnwas mit den Ergebnissen in den Proben korrespondiert. Mittels Röntgenbeugung (X-Ray Diffraction, XRD) zeigtenrnsich in allen Proben ähnliche Spektren. Das lässt darauf schließen, dass das pulverisierte Material in allen Probenrndas gleiche ist. Hierbei zeigte sich eine sehr gute Übereinstimmung mit Schoepit und/oder meta-rnSchoepit(UO2)8O2(OH)12(H2O)10, sowie Becquerelite. Weiterhin war weder Autunit, Sabugalit noch Uranylphosphatrnanwesend, was die Ergebnisse einer anderen Studie, durchgeführt an denselben Proben, wiederlegt. DiernAnwesenheit von P, C oder Ca im Probenmaterial konnte ausgeschlossen werden. Im Falle von Calciumkann diesrnmit der Anwesenheit von Uran erklärt werden, welches aufgrund seines Atomradius bevorzugt in Becquerelite (1:6)rneingebaut wird. Die beiden Hauptpeaks für Uran lagen im Falle von U 4f 7/2 bei 382.0 eV und im Falle von U 4f 5/2rnbei 392 eV. Diese Werte mit den Literaturwerten für Schoepit und meta-Schoepitüberein. Die Ergebnissernelektronenmikroskopischen Untersuchung zeigen U, O, Ca, Ti als dominante Komponenten in allen Messungen.rnElemente wie Si, Al, Fe, S, Na, und C wurden ebenfalls detektiert; allerdings kann nicht ausgeschlossen werden,rndass diese Elemente aus dem Boden in der unmittelbaren Umgebung der Munitionsgeschosse stammen. Gold wurdernebenfalls gemessen, was aber auf die Goldarmierung in den Probenaufbereitungsbehältern zurückgeführt werdenrnkann. Die Elektronenmikroskopie zeigte außerdem einige Stellen in denen elementares Uran und Bodenmineralernsowie sekundäre Uranminerale auftraten. Die Elementübersicht zeigt einen direkten Zusammenhang zwischen U andrnCa und gleichzeitig keine Korrelation zwischen U und Si, oder Mg. Auf der anderen Seite zeigte sich aber einrnZusammenhang zwischen Si und Al da beide Konstituenten von Bodenmineralen darstellen. Eine mit Hilfe derrnElektronenstrahlmikroanalyse durchgeführte quantitative Analyse zeigte den Massenanteil von Uran bei ca. 78 - 80%,rnwas mit den 78,2% and 79,47% für Becquerelite beziehungsweise Schoepit aufgrund ihrer Summenformelrnkorrespondiert. Zusätzlich zeigt sich für Calcium ein Massenanteil von 2% was mit dem Wert in Becquerelite (2.19%)rnrecht gut übereinstimmt. Der Massenanteil von Ti lag in einigen Fällen bei 0,77%, was auf eine noch nicht korrodierternDU-Legierung zurückzuführen ist. Ein Lösungsexperiment wurde weiterhin durchgeführt, wobei eine 0,01 M NaClO4-rnLösung zum Einsatz kam in der die verbliebene Probensubstanz der Korrosionsprodukte gelöst wurde;rnNatriumperchlorate wurde hierbei genutzt um die Ionenstärke bei 0,01 zu halten. Um Verunreinigungen durchrnatmosphärisches CO2 zu vermeiden wurden die im Versuch für die drei Hauptproben genutzten 15 Probenbehälterrnmit Stickstoffgas gespült. Eine Modelkalkulation für den beschriebenen Versuchsaufbau wurde mit Visual MINTEQrnv.3.0 für die mittels vorgenannten Analysemethoden beschriebenen Mineralphasen im pH-Bereich von 6 – 10 imrnFalle von Becquerelite, und Schoepit berechnet. Die modellierten Lösungskurven wurden unter An- und Abwesenheitrnvon atmosphärischem CO2 kalkuliert. Nach dem Ende des Lösungsexperiments (Dauer ca. 6 Monate) zeigten diernKonzentrationen des gelösten Urans, gemessen mittels ICP-OES, gute Übereinstimmung mit den modelliertenrnSchoepit und Becquerelite Kurven. Auf Grund des ähnlichen Löslichkeitverhaltens war es nicht möglich zwichen denrnbeiden Mineralen zu unterscheiden. Schoepit kontrolliert im sauren Bereich die Löslichkeit des Urans, währendrnbecquerelit im basichen am wenigsten gelöst wird. Des Weiteren bleibt festzuhalten, dass ein Anteil an CO2 in diernverschlossenen Probenbehälter eingedrungen ist, was sich mit der Vorhersage der Modeldaten deckt. Die Löslichkeitrnvon Uran in der Lösung als Funktion des pH-Wertes zeigte die niedrigsten Konzentrationen im Falle einer Zunahmerndes pH-Wertes von 5 auf 7 (ungefähr 5,1 x 10-6 mol/l) und einer Zunahme des pH-Wertes auf 8 (ungefähr 1,5 x 10-6rnmol/l bei). Oberhalb dieses Bereichs resultiert jeder weitere Anstieg des pH-Wertes in einer Zunahme gelösten Uransrnin der Lösung. Der ph-Wert der Lösung wie auch deren pCO2-Wert kontrollieren hier die Menge des gelösten Urans.rnAuf der anderen Seite zeigten im Falle von Becquerelite die Ca-Konzentrationen höhere Werte als erwartet, wobeirnwahrscheinlich auf eine Vermischung der Proben mit Bodensubstanz zurückgeführt werden kann. Abschließendrnwurde, unter Berücksichtigung der oben genannten Ergebnisse, eine Fallstudie aus Basrah (Irak) diskutiert, wo inrnzwei militärischen Konflikten Uranmunition in zwei Regionen unter verschiedenen Umweltbedingungen eingesetztrnwurden.
Resumo:
We present a combined experimental and theoretical study of the electronic transport through single-molecule junctions based on nitrile-terminated biphenyl derivatives. Using a scanning tunneling microscope-based break-junction technique, we show that the nitrile-terminated compounds give rise to well-defined peaks in the conductance histograms resulting from the high selectivity of the N-Au binding. Ab initio calculations have revealed that the transport takes place through the tail of the LUMO. Furthermore, we have found both theoretically and experimentally that the conductance of the molecular junctions is roughly proportional to the square of the cosine of the torsion angle between the two benzene rings of the biphenyl core, which demonstrates the robustness of this structure-conductance relationship.
Resumo:
The first objective of this thesis was to examine the hygroscopic and morphological nature of various substances through the use of an Environmental Scanning Electron Microscope (ESEM). The hygroscopic growth and changes in morphology for pure-component aerosols were studied for particles greater than 2 µm in size. Hygroscopic growth was observed through changes in relative humidity (RH) and hygroscopic growth curves were created. The second objective of this thesis, the hygroscopic growth of multi-component aerosol mixtures, was studied using Hygroscopic Tandem Differential Mobility Analysis(HTDMA). The size distribution for an aerosol stream was determined before and after the stream was subjected to an increase in relative humidity.
Resumo:
OBJECTIVES: The aim of this study was to evaluate the cavitation rate of proximal caries using different magnification aids in vitro. METHODS: Radiographs of 285 extracted teeth were taken and the proximal surfaces were graded to the criteria R0 (no radiolucency), R1 (radiolucency confined to the outer half of enamel), R2 (inner half of enamel) and R3 (outer half of dentin). Subsequently, the proximal surfaces were checked for the presence of cavitations with the naked eye (NE), and by using 4.3 x magnification eyeglasses (ME), a stereo microscope (SM, 10x), or a scanning electron microscope (SEM, up to 2000 x magnification). RESULTS: In surfaces with R3 caries, cavitations were visible in 56 of 59 cases with the naked eye. When using SEM, all surfaces revealed cavitations (100%). Regarding the surfaces with R2 lesion, 36 of 46 cases showed cavitations (NE); the corresponding values were 39/46 (ME), 41/46 (SM), and 46/46 (SEM); in the latter, in most cases deep defects could be observed. With regard to R1 lesions, 36/60 (NE), 43/60 (ME), 45/60 (SM), and 58/60 (SEM) cases revealed cavitations. A breakdown of radiographically sound surfaces (R0) was present in some 10% of the examined surfaces (24/261, NE; 33/261, SEM). CONCLUSIONS: Cavitations (defined as breakdown of the surface) are present in significantly more cases than previously reported. This might be an explanation why even small radiolucencies tend to progress, albeit slowly. Thus, close follow-ups should strongly be recommended when considering a preventive treatment regimen with small radiolucencies.
Resumo:
The objective of this doctoral research is to investigate the internal frost damage due to crystallization pore pressure in porous cement-based materials by developing computational and experimental characterization tools. As an essential component of the U.S. infrastructure system, the durability of concrete has significant impact on maintenance costs. In cold climates, freeze-thaw damage is a major issue affecting the durability of concrete. The deleterious effects of the freeze-thaw cycle depend on the microscale characteristics of concrete such as the pore sizes and the pore distribution, as well as the environmental conditions. Recent theories attribute internal frost damage of concrete is caused by crystallization pore pressure in the cold environment. The pore structures have significant impact on freeze-thaw durability of cement/concrete samples. The scanning electron microscope (SEM) and transmission X-ray microscopy (TXM) techniques were applied to characterize freeze-thaw damage within pore structure. In the microscale pore system, the crystallization pressures at sub-cooling temperatures were calculated using interface energy balance with thermodynamic analysis. The multi-phase Extended Finite Element Modeling (XFEM) and bilinear Cohesive Zone Modeling (CZM) were developed to simulate the internal frost damage of heterogeneous cement-based material samples. The fracture simulation with these two techniques were validated by comparing the predicted fracture behavior with the captured damage from compact tension (CT) and single-edge notched beam (SEB) bending tests. The study applied the developed computational tools to simulate the internal frost damage caused by ice crystallization with the two dimensional (2-D) SEM and three dimensional (3-D) reconstructed SEM and TXM digital samples. The pore pressure calculated from thermodynamic analysis was input for model simulation. The 2-D and 3-D bilinear CZM predicted the crack initiation and propagation within cement paste microstructure. The favorably predicted crack paths in concrete/cement samples indicate the developed bilinear CZM techniques have the ability to capture crack nucleation and propagation in cement-based material samples with multiphase and associated interface. By comparing the computational prediction with the actual damaged samples, it also indicates that the ice crystallization pressure is the main mechanism for the internal frost damage in cementitious materials.
Resumo:
Titanium oxide is an important semiconductor, which is widely applied for solar cells. In this research, titanium oxide nanotube arrays were synthesized by anodization of Ti foil in the electrolyte composed of ethylene glycol containing 2 vol % H2O and 0.3 wt % NH4F. The voltages of 40V-50V were employed for the anodizing process. Pore diameters and lengths of the TiO2 nanotubes were evaluated by field emission scanning electron microscope (FESEM). The obtained highly-ordered titanium nanotube arrays were exploited to fabricate photoelectrode for the Dye-sensitized solar cells (DSSCS). The TiO2 nanotubes based DSSCS exhibited an excellent performance with a high short circuit current and open circuit voltage as well as a good power conversion efficiency. Those can be attributed to the high surface area and one dimensional structure of TiO2 nanotubes, which could hold a large amount of dyes to absorb light and help electron percolation process to hinder the recombination during the electrons diffusion in the electrolyte.
Resumo:
Single molecular junction conductances of a family of five symmetric and two unsymmetric perylene tetracarboxylic bisimides (PBI) with variable bay-area substituents were studied employing a scanning tunneling microscope (STM)-based break junction technique. The stretching experiments provide clear evidence for the formation of single molecular junctions and π–π stacked dimers. Electrolyte gating demonstrates a distinct gating effect in symmetric molecular junctions, which strongly depends on molecular structure and properties of the solvent/electrolyte. Weak π–π-coupling in the unsymmetric dimers prevents rectification.
Resumo:
OBJECTIVES Optical scanners combined with computer-aided design and computer-aided manufacturing (CAD/CAM) technology provide high accuracy in the fabrication of titanium (TIT) and zirconium dioxide (ZrO) bars. The aim of this study was to compare the precision of fit of CAD/CAM TIT bars produced with a photogrammetric and a laser scanner. METHODS Twenty rigid CAD/CAM bars were fabricated on one single edentulous master cast with 6 implants in the positions of the second premolars, canines and central incisors. A photogrammetric scanner (P) provided digitized data for TIT-P (n=5) while a laser scanner (L) was used for TIT-L (n=5). The control groups consisted of soldered gold bars (gold, n=5) and ZrO-P with similar bar design. Median vertical distance between implant and bar platforms from non-tightened implants (one-screw test) was calculated from mesial, buccal and distal scanning electron microscope measurements. RESULTS Vertical microgaps were not significantly different between TIT-P (median 16μm; 95% CI 10-27μm) and TIT-L (25μm; 13-32μm). Gold (49μm; 12-69μm) had higher values than TIT-P (p=0.001) and TIT-L (p=0.008), while ZrO-P (35μm; 17-55μm) exhibited higher values than TIT-P (p=0.023). Misfit values increased in all groups from implant position 23 (3 units) to 15 (10 units), while in gold and TIT-P values decreased from implant 11 toward the most distal implant 15. SIGNIFICANCE CAD/CAM titanium bars showed high precision of fit using photogrammetric and laser scanners. In comparison, the misfit of ZrO bars (CAM/CAM, photogrammetric scanner) and soldered gold bars was statistically higher but values were clinically acceptable.
Resumo:
OBJECTIVE To compare the precision of fit of full-arch implant-supported screw-retained computer-aided designed and computer-aided manufactured (CAD/CAM) titanium-fixed dental prostheses (FDP) before and after veneering. The null-hypothesis was that there is no difference in vertical microgap values between pure titanium frameworks and FDPs after porcelain firing. MATERIALS AND METHODS Five CAD/CAM titanium grade IV frameworks for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI tooth positions 15, 13, 11, 21, 23, 25) were fabricated after digitizing the implant platforms and the cuspid-supporting framework resin pattern with a laser scanner (CARES(®) Scan CS2; Institut Straumann AG, Basel, Switzerland). A bonder, an opaquer, three layers of porcelain, and one layer of glaze were applied (Vita Titankeramik) and fired according to the manufacturer's preheating and fire cycle instructions at 400-800°C. The one-screw test (implant 25 screw-retained) was applied before and after veneering of the FDPs to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from interproximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS All vertical microgaps were clinically acceptable with values <90 μm. No statistically significant pairwise difference (P = 0.98) was observed between the relative effects of vertical microgap of unveneered (median 19 μm; 95% CI 13-35 μm) and veneered FDPs (20 μm; 13-31 μm), providing support for the null-hypothesis. Analysis within the groups showed significantly different values between the five implants of the FDPs before (P = 0.044) and after veneering (P = 0.020), while a monotonous trend of increasing values from implant 23 (closest position to screw-retained implant 25) to 15 (most distant implant) could not be observed (P = 0.169, P = 0.270). CONCLUSIONS Full-arch CAD/CAM titanium screw-retained frameworks have a high accuracy. Porcelain firing procedure had no impact on the precision of fit of the final FDPs. All implant microgap measurements of each FDP showed clinically acceptable vertical misfit values before and after veneering. Thus, the results do not only show accurate performance of the milling and firing but show also a reproducible scanning and designing process.
Resumo:
Ageing societies suffer from an increasing incidence of bone fractures. Bone strength depends on the amount of mineral measured by clinical densitometry, but also on the micromechanical properties of the hierarchical organization of bone. Here, we investigate the mechanical response under monotonic and cyclic compression of both single osteonal lamellae and macroscopic samples containing numerous osteons. Micropillar compression tests in a scanning electron microscope, microindentation and macroscopic compression tests were performed on dry ovine bone to identify the elastic modulus, yield stress, plastic deformation, damage accumulation and failure mechanisms. We found that isolated lamellae exhibit a plastic behaviour, with higher yield stress and ductility but no damage. In agreement with a proposed rheological model, these experiments illustrate a transition from a ductile mechanical behaviour of bone at the microscale to a quasi-brittle response driven by the growth of cracks along interfaces or in the vicinity of pores at the macroscale.
Resumo:
OBJECTIVE To investigate how the modulus of elasticity of resin composites influences marginal quality in restorations submitted to thermocyclic and mechanical loading. METHODS Charisma, Filtek Supreme XTE and Grandio were selected as they were found to possess different moduli of elasticity but quite similar polymerization contraction. MOD cavities (n=30) were prepared in extracted premolars, restored and then subjected to thermocyclic and mechanical loading. Marginal quality of the restorations before and after loading was analyzed on epoxy replicas under a scanning electron microscope. The percentage of gap-free margins and occurrence of paramarginal fractures were registered. Modulus of elasticity and polymerization contraction were analyzed with parametric and margins with nonparametric ANOVA and post hoc Tukey HSD or Wilcoxon rank-sum tests, respectively. The number of paramarginal fractures was analyzed with exact Fisher tests (α=0.05). RESULTS Grandio demonstrated significantly more gap-free enamel margins than Charisma and Filtek Supreme XTE, before and after loading (p<0.01), whereas there was no difference between Charisma and Filtek Supreme XTE (p>0.05). No significant effect of resin composite (p=0.81) on the quality of dentine margins was observed, before or after loading. Deterioration of all margins was evident after loading (p<0.0001). More paramarginal enamel fractures were observed after loading in teeth restored with Grandio when compared to Charisma (p=0.008). CONCLUSIONS The resin composite with the highest modulus of elasticity resulted in the highest number of gap-free enamel margins but with an increased incidence of paramarginal enamel fractures. CLINICAL SIGNIFICANCE The results from this study suggest that the marginal quality of restorations can be improved by the selection of a resin composite with modulus of elasticity close to that of dentine, although an increase in paramarginal enamel fractures can result as a consequence.
Resumo:
Aging societies suffer from an increasing incidence of bone fractures. Bone strength depends on the amount of mineral measured by clinical densitometry, but also on the micromechanical properties of the bone hierarchical organization. A good understanding has been reached for elastic properties on several length scales, but up to now there is a lack of reliable postyield data on the lower length scales. In order to be able to describe the behavior of bone at the microscale, an anisotropic elastic-viscoplastic damage model was developed using an eccentric generalized Hill criterion and nonlinear isotropic hardening. The model was implemented as a user subroutine in Abaqus and verified using single element tests. A FE simulation of microindentation in lamellar bone was finally performed show-ing that the new constitutive model can capture the main characteristics of the indentation response of bone. As the generalized Hill criterion is limited to elliptical and cylindrical yield surfaces and the correct shape for bone is not known, a new yield surface was developed that takes any convex quadratic shape. The main advantage is that in the case of material identification the shape of the yield surface does not have to be anticipated but a minimization results in the optimal shape among all convex quadrics. The generality of the formulation was demonstrated by showing its degeneration to classical yield surfaces. Also, existing yield criteria for bone at multiple length scales were converted to the quadric formulation. Then, a computational study to determine the influence of yield surface shape and damage on the in-dentation response of bone using spherical and conical tips was performed. The constitutive model was adapted to the quadric criterion and yield surface shape and critical damage were varied. They were shown to have a major impact on the indentation curves. Their influence on indentation modulus, hardness, their ratio as well as the elastic to total work ratio were found to be very well described by multilinear regressions for both tip shapes. For conical tips, indentation depth was not a significant fac-tor, while for spherical tips damage was insignificant. All inverse methods based on microindentation suffer from a lack of uniqueness of the found material properties in the case of nonlinear material behavior. Therefore, monotonic and cyclic micropillar com-pression tests in a scanning electron microscope allowing a straightforward interpretation comple-mented by microindentation and macroscopic uniaxial compression tests were performed on dry ovine bone to identify modulus, yield stress, plastic deformation, damage accumulation and failure mecha-nisms. While the elastic properties were highly consistent, the postyield deformation and failure mech-anisms differed between the two length scales. A majority of the micropillars showed a ductile behavior with strain hardening until failure by localization in a slip plane, while the macroscopic samples failed in a quasi-brittle fashion with microcracks coalescing into macroscopic failure surfaces. In agreement with a proposed rheological model, these experiments illustrate a transition from a ductile mechanical behavior of bone at the microscale to a quasi-brittle response driven by the growth of preexisting cracks along interfaces or in the vicinity of pores at the macroscale. Subsequently, a study was undertaken to quantify the topological variability of indentations in bone and examine its relationship with mechanical properties. Indentations were performed in dry human and ovine bone in axial and transverse directions and their topography measured by AFM. Statistical shape modeling of the residual imprint allowed to define a mean shape and describe the variability with 21 principal components related to imprint depth, surface curvature and roughness. The indentation profile of bone was highly consistent and free of any pile up. A few of the topological parameters, in particular depth, showed significant correlations to variations in mechanical properties, but the cor-relations were not very strong or consistent. We could thus verify that bone is rather homogeneous in its micromechanical properties and that indentation results are not strongly influenced by small de-viations from the ideal case. As the uniaxial properties measured by micropillar compression are in conflict with the current literature on bone indentation, another dissipative mechanism has to be present. The elastic-viscoplastic damage model was therefore extended to viscoelasticity. The viscoelastic properties were identified from macroscopic experiments, while the quasistatic postelastic properties were extracted from micropillar data. It was found that viscoelasticity governed by macroscale properties has very little influence on the indentation curve and results in a clear underestimation of the creep deformation. Adding viscoplasticity leads to increased creep, but hardness is still highly overestimated. It was possible to obtain a reasonable fit with experimental indentation curves for both Berkovich and spherical indenta-tion when abandoning the assumption of shear strength being governed by an isotropy condition. These results remain to be verified by independent tests probing the micromechanical strength prop-erties in tension and shear. In conclusion, in this thesis several tools were developed to describe the complex behavior of bone on the microscale and experiments were performed to identify its material properties. Micropillar com-pression highlighted a size effect in bone due to the presence of preexisting cracks and pores or inter-faces like cement lines. It was possible to get a reasonable fit between experimental indentation curves using different tips and simulations using the constitutive model and uniaxial properties measured by micropillar compression. Additional experimental work is necessary to identify the exact nature of the size effect and the mechanical role of interfaces in bone. Deciphering the micromechanical behavior of lamellar bone and its evolution with age, disease and treatment and its failure mechanisms on several length scales will help preventing fractures in the elderly in the future.
Resumo:
OBJECTIVES To investigate the composition and the microstructural and mechanical characterization of three different types of lingual brackets. MATERIALS AND METHODS Incognito™ (3M Unitek), In-Ovation L (DENTSPLY GAC) and STb™ (Light Lingual System, ORMCO) lingual brackets were studied under the scanning electron microscope employing backscattered electron imaging and their elemental composition was analysed by energy-dispersive X-ray microanalysis. Additionally, Vickers hardness was assessed using a universal hardness-testing machine, and the indentation modulus was measured according to instrumented indentation test. Two-way analysis of variance was conducted employing bracket type and location (base and wing) as discriminating variable. Significant differences among groups were allocated by post hoc Student-Newman-Keuls multiple comparison analysis at 95% level of significance. RESULTS Three different phases were identified for Incognito and In-Ovation L bracket based on mean atomic number contrast. On the contrary, STb did not show mean atomic contrast areas and thus it is recognized as a single phase. Incognito is a one-piece bracket with the same structure in wing and base regions. Incognito consists mainly of noble metals while In-Ovation L and STb show similar formulations of ferrous alloys in wing and base regions. No significant differences were found between ferrous brackets in hardness and modulus values, but there were significant differences between wing and base regions. Incognito illustrated intermediate values with significant differences from base and wing values of ferrous brackets. CONCLUSIONS/IMPLICATIONS Significant differences exist in microstructure, elemental composition, and mechanical properties among the brackets tested; these might have a series of clinical implications during mechanotherapy.
Resumo:
OBJECTIVE To analyze the precision of fit of implant-supported screw-retained computer-aided-designed and computer-aided-manufactured (CAD/CAM) zirconium dioxide (ZrO) frameworks. MATERIALS AND METHODS Computer-aided-designed and computer-aided-manufactured ZrO frameworks (NobelProcera) for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI positions 15, 13, 11, 21, 23, 25) were fabricated using a laser (ZrO-L, N = 6) and a mechanical scanner (ZrO-M, N = 5) for digitizing the implant platform and the cuspid-supporting framework resin pattern. Laser-scanned CAD/CAM titanium (TIT-L, N = 6) and cast CoCrW-alloy frameworks (Cast, N = 5) fabricated on the same model and designed similar to the ZrO frameworks were the control. The one-screw test (implant 25 screw-retained) was applied to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from approximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS No statistically significant pairwise difference was observed between the relative effects of vertical microgap between ZrO-L (median 14 μm; 95% CI 10-26 μm), ZrO-M (18 μm; 12-27 μm) and TIT-L (15 μm; 6-18 μm), whereas the values of Cast (236 μm; 181-301 μm) were significantly higher (P < 0.001) than the three CAD/CAM groups. A monotonous trend of increasing values from implant 23 to 15 was observed in all groups (ZrO-L, ZrO-M and Cast P < 0.001, TIT-L P = 0.044). CONCLUSIONS Optical and tactile scanners with CAD/CAM technology allow for the fabrication of highly accurate long-span screw-retained ZrO implant-reconstructions. Titanium frameworks showed the most consistent precision. Fit of the cast alloy frameworks was clinically inacceptable.