860 resultados para Room-Temperature Ferromagnetism
Resumo:
Meropenem, a carbapenem antibiotic displaying a broad spectrum of antibacterial activity, is administered in Medical Intensive Care Unit to critically ill patients undergoing continuous veno-venous haemodiafiltration (CVVHDF). However, there are limited data available to substantial rational dosing decisions in this condition. In an attempt to refine our knowledge and propose a rationally designed dosage regimen, we have developed a HPLC method to determine meropenem after solid-phase extraction (SPE) of plasma and dialysate fluids obtained from patients under CVVHDF. The assay comprises the simultaneous measurement of meropenem's open-ring metabolite UK-1a, whose fate has never been studied in CVVHDF patients. The clean-up procedure involved a SPE on C18 cartridge. Matrix components were eliminated with phosphate buffer pH 7.4 followed by 15:85 MeOH-phosphate buffer pH 7.4. Meropenem and UK-1a were subsequently desorbed with MeOH. The eluates were evaporated under nitrogen at room temperature (RT) and reconstituted in phosphate buffer pH 7.4. Separation was performed at RT on a Nucleosil 100-5 microm C18 AB cartridge column (125 x 4 mm I.D.) equipped with a guard column (8 x 4 mm I.D.) with UV-DAD detection set at 208 nm. The mobile phase was 1 ml min(-1), using a step-wise gradient elution program: %MeOH/0.005 M tetrabutylammonium chloride pH 7.4; 10/90-50/50 in 27 min. Over the range of 5-100 microg ml(-1), the regression coefficient of the calibration curves (plasma and dialysate) were >0.998. The absolute extraction recoveries of meropenem and UK-1a in plasma and filtrate-dialysate were stable and ranged from 88-93 to 72-77% for meropenem, and from 95-104 to 75-82% for UK-1a. In plasma and filtrate-dialysate, respectively, the mean intra-assay precision was 4.1 and 2.6% for meropenem and 4.2 and 3.7% for UK-1a. The inter-assay variability was 2.8 and 3.6% for meropenem and 2.3 and 2.8% for UK-1a. The accuracy was satisfactory for both meropenem and UK-1a with deviation never exceeding 9.0% of the nominal concentrations. The stability of meropenem, studied in biological samples left at RT and at +4 degrees C, was satisfactory with < 5% degradation after 1.5 h in blood but reached 22% in filtrate-dialysate samples stored at RT for 8 h, precluding accurate measurements of meropenem excreted unchanged in the filtrate-dialysate left at RT during the CVVHDF procedure. The method reported here enables accurate measurements of meropenem in critically ill patients under CVVHDF, making dosage individualisation possible in such patients. The levels of the metabolite UK-1a encountered in this population of patients were higher than those observed in healthy volunteers but was similar to those observed in patients with renal impairment under hemodialysis.
Resumo:
In this paper we report on the growth of thick films of magnetoresistive La2/3Sr1/3MnO3 by using spray and screen printing techniques on various substrates (Al2O3 and ZrO2). The growth conditions are explored in order to optimize the microstructure of the films. The films display a room-temperature magnetoresistance of 0.0012%/Oe in the 1 kOe field region. A magnetic sensor is described and tested.
Resumo:
Spherical carbon coated iron particles of nanometric diameter in the 510 nm range have been produced by arc discharge at near-atmospheric pressure conditions (using 58·10 4 Pa of He). The particles exhibit a crystalline dense iron core with an average diameter 7.4 ± 2.0 nm surrounded by a sealed carbon shell, shown by transmission electron microscopy (TEM), selected-area diffrac- tion (SAED), energy-dispersive X-ray analysis (STEM-EDX) and electron energy loss spectroscopy (EELS). The SAED, EDX and EELS results indicate a lack of traces of core oxidized phases showing an efficient protection role of the carbon shell. The magnetic properties of the nanoparticles have been investigated in the 5300 K temperature range using a superconducting quantum interference device (SQUID). The results reveal a superparamagnetic behaviour with an average monodomain diameter of 7.6 nm of the nanoparticles. The zero field cooled and field cooled (ZFC-FC)magnetization curves show a blocking temperature (TB)at room temperature very suitable for biomedical applications (drug delivery, magnetic resonance imaging MRI, hyperthermia).
Resumo:
Chemical shifts of protons can report on metabolic transformations such as the conversion of choline to phosphocholine. To follow such processes in vivo, magnetization can be enhanced by dynamic nuclear polarization (DNP). We have hyperpolarized in this manner nitrogen-15 spins in (15)N-labeled choline up to 3.3% by irradiating the 94 GHz electron spin resonance of admixed TEMPO nitroxide radicals in a magnetic field of 3.35 T during ca. 3 h at 1.2 K. The sample was subsequently transferred to a high-resolution magnet, and the enhanced polarization was converted from (15)N to methyl- and methylene protons, using the small (2,3)J((1)H,(15)N) couplings in choline. The room-temperature lifetime of nitrogen polarization in choline, T(1)((15)N) approximately 200 s, could be considerably increased by partial deuteration of the molecule. This procedure enables studies of choline metabolites in vitro and in vivo using DNP-enhanced proton NMR.
Resumo:
The most extensively studied Heusler alloys are those based on the Ni-Mn-Ga system. However, to overcome the high cost of Gallium and the usually low martensitic transformation temperature, the search for Ga-free alloys has been recently attempted, particularly, by introducing In, Sn or Sb. In this work, two alloys (Mn50Ni35.5In14.5 and Ni50Mn35In15) have been obtained by melt spinning. We outline their structural and thermal behaviour. Mn50Ni35.5In14.5 alloy has the transformation above room temperature whereas Ni50Mn35In15 does not have this transformation in the temperature range here analyzed
Effect of Delay in Testing Asphalt Concrete Specimens for Marshall Stability, MLR-86-08, Draft, 1986
Resumo:
The Central Laboratory has been delaying the mix design testing of 2 1/2" X 4" Marshall specimens for stability, until the next day after molding. For example, if the mixes are made and samples molded on Friday a man would have to come in and work on Saturday to test these specimens. The reason for this is that the ASTM-01559 "Resistance to Plastic Flow of Bituminous Mixes Using Marshall Apparatus," states that "the specimens after being molded shall be carefully transferred to a smooth, flat surface and allowed to stand overnight at room temperature, before being weighed, measured and tested." The AASHTO procedure, AASHTO Designation T-245-82 "Resistance to Plastic Flow of Bituminous Mixtures using Marshall Apparatus," does not say when the specimens shall be tested for stability. The IDOT Lab. Specifications, Test Method No. Iowa 502-8 and test method No. Iowa 506-C "compacting asphaltic concrete by the Marshall Method" and "Resistance to Plastic Flow of Bituminous Mixtures Using the Marshall Apparatus," respectively, only state that the specimens shall be cooled before testing. Due to the above conflict in specifications, a number of mix samples were tested, in the Central Lab, for stability on different days. This should furnish enough information to allow us to change the procedure and to test for stability the same day molded, or be able to delay the testing for 3 days or more.
Resumo:
Asphalt is used as a binder for thin maintenance surface (TMS) applications because of two key properties, it is waterproof and it adheres relatively well to the aggregate. Since asphalt is too stiff at room temperature to apply to the road surface, it is usually applied as either a cutback asphalt or an asphalt emulsion. The asphalt emulsions can be further divided into high float emulsions, cationic emulsions or polymer-modified binders, which are emulsions with polymers added to them. These types of binders are discussed further below.
Resumo:
The aim of this work was to evaluate the efficiency of carboxymethyl cellulose (CMC) and starch blends as carrier materials of rhizobial inoculants regarding their capacity to maintain viable cells and promote cowpea (Vigna unguiculata) nodulation. The experimental design adopted was completely randomized, with three replicates. Forty different compositions of carboxymethyl cellulose (CMC) with starch, compatibilized or not with different proportions of MgO or ZnO, were evaluated regarding their ability of maintaining rhizobial viable cells during the storage period of one month at room temperature, in an initial screening. Thereafter, selected inoculant carrier blends were evaluated regarding their ability to maintain viable rhizobial cells for a period of 165 days, and their performance as inoculant carriers was compared to a peat-based inoculant carrier under greenhouse conditions. Rhizobial cells were better maintained in blends containing 50-60% CMC. Compatibilizing agents did not increase survival of rhizobial cells for 30 days of storage. The cowpea nodulation of polymer blends was statistically the same of peat-based inoculants. CMC/starch polymer blends are efficient carriers to rhizobial inoculants for up to 165 days of storage, when compatibilized with MgO (1%).
Resumo:
This study aimed to compare O2 consumption (VO2) determination by the gas-exchange (VO2GE) and Fick (VO2F) methods in cardiac surgical patients. A total of 10 mechanically ventilated postoperative patients were studied prospectively. Thermodilution was performed using three randomly applied techniques: room temperature saline injected at end expiration, room temperature saline randomly injected in the respiratory cycle, and iced saline injected at end expiration. The influence of the number of thermodilution determinations was assessed by comparing results from 2 and 10 injections. The variability of VO2F was greater than that of VO2GE. There was no bias between VO2GE and VO2F values using injectate at room temperature. Accuracy and precision were not improved by increasing the number of cardiac output determinations from 2 to 10. A significant bias was observed using ice-cold injectate, VO2F being 18.0 +/- 15.4 ml/min/m2 lower than VO2GE (p = 0.001). Published results when comparing VO2F and VO2GE are discrepant. However, a significant bias was found in all studies using cold injectate, with lower VO2F values. We conclude that iced injectate should not be used to assess VO2 in critically ill patients.
Resumo:
New products available for food creations include a wide variety of "supposed" food grade aerosol sprays. However, the gas propellants used cannot be considered as safe. The different legislations available did not rule any maximum residue limits, even though these compounds have some limits when used for other food purposes. This study shows a preliminary monitoring of propane, butane and dimethyl ether residues, in cakes and chocolate after spraying, when these gases are used as propellants in food aerosol sprays. Release kinetics of propane, butane and dimethyl ether were measured over one day with sprayed food, left at room temperature or in the fridge after spraying. The alkanes and dimethyl ether analyses were performed by headspace-gas chromatography-mass spectrometry/thermal conductivity detection, using monodeuterated propane and butane generated in situ as internal standards. According to the obtained results and regardingthe extrapolations of the maximum residue limits existing for these substances, different delays should be respected according to the storage conditions and the gas propellant to consume safely the sprayed food.
Resumo:
Background: Urine is still the matrix of choice to fight against doping, because it can be collected non-invasively during anti-doping tests. Most of the World Anti-Doping Agency's accredited laboratories have more than 20 years experience in analyzing this biological fluid and the majority of the compounds listed in the 2010 Prohibited List - International Standard are eliminated through the urinary apparatus. Storing and transporting urine samples for doping analyses does not include a specific protocol to prevent microbial and thermal degradation. The use of a rapid and reliable screening method could enable determine reference intervals for urine specimens in doping control samples and evaluate notably the prevalence of microbial contamination known to be responsible for the degradation of chemical substances in urine.Methods: The Sysmex(R) UF-500i is a recent urine flow cytometer analyzer capable of quantifying BACT and other urinary particles such as RBC, WBC, EC, DEBRIS, CAST, PATH. CAST, YLC, SRC as well as measuring urine conductivity. To determine urine anti-doping reference intervals, 501 samples received in our laboratory over a period of two months were submitted to an immediate examination. All samples were collected and then transported at room temperature. Analysis of variance was performed to test the effects of factors such as gender, test type [in-competition, out-of-competition] and delivery time.Results: The data obtained showed that most of the urine samples were highly contaminated with bacteria. The other urine particles were also very different according to the factors.Conclusions: The Sysmex(R) UF-500i was capable of providing a snapshot of urine particles present in the samples at the time of the delivery to the laboratory. These particles, BACT in particular, gave a good idea of the possible microbial degradation which had and/or could have occurred in the sample. This information could be used as the first quality control set up in WADA (World Anti-Doping Agency) accredited laboratories to determine if steroid profiles, endogenous and prohibited substances have possibly been altered. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Työn tavoitteena oli kartoittaa yleisesti kartongin valmistukseen käytettävien massatyyppien muovattavuuspotentaali. Muovattuvuuteen eniten vaikuttava tekijänä pidettiinmassojen murtovenymää. Työssä tutkittiin kosteuden ja lämpötilan sekä vetonopeuden vaikutusta mekaanisten ja sellumassojen ominaisuuksiin laboratorio-olosuhteissa. Kirjallisuusosassa tarkastellaan paperin lasisiirtymälämpötilaa muovauksen kannalta oleellisena tekijä. Lisäksi käydään läpi tapoja, joilla murtovenymää voidaan kasvattaa. Kartongin keskikerroksen aallotuksessa ja valmistettaessa paperipohjaisia tuotteita syvävedolla, käytetään hyväksi paperin pehmenemistä lämpötilan ja kosteuden alaisena. Niiden olosuhteita tarkastellaan lyhyesti. Lisäksi luodaan katsaus lämpötilan, kosteuden ja nopeuden vaikutuksistapaperin mekaanisiin ominaisuuksiin. Työn kokeellisessa osassa massojen mekaanisia ominaisuuksia testattiin erilaisissa kosteuspitoisuuksissasekä lämpötiloissa eri vetonopeuksilla. Kokeiden perusteella pyrittiin löytämään olosuhteet kullekin massalle, joissa niillä on paras murtovenymä. Lisäksi selvitettiin kuidun kihartamisen, sellumassojen jauhatuksen sekä arkin vapaan kuivumisen vaikutusta murtovenymään. Erilaiset massat saavuttavat parhaan murtovenymän erilaisissa kosteus- ja lämpötilaolosuhteissa. Sellumassoilla paras murtovenymä saadaan huoneenlämpötilassa ja paperin kosteuspitoisuuden ollessa välillä 11...12%. CTMP-massojen paras murtovenymä saadaan vedellä kyllästetyllä paperilla kohotetussa lämpötilassa. Lämpötila riippuu CTMP-massan valmistustavasta ja raaka-aineesta. Sellumassoilla on parempi kokonaisvenymä, kuin ligniinipitoisilla massoilla. Vetonopeuden vaikutus murtovenymään riippuu massasta sekä kosteudesta. Alhaisessa kosteudessa suurempi vetonopeus antaa aina pienemmän venymän. Kosteuden noustessa riippuu massasta, miten vetonopeus vaikuttaa murtovenymään. Plastinen osa tietystä venymästä on riippumaton massasta, jauhatusasteesta ja kuivatustavasta. Ainut vaikuttava muuttuja on kosteus. Kosteuden kasvu kasvattaa plastista venymää.
Resumo:
In this study we observe the poisoning effect of S to the adsorption and dissociation of 02 molecule on Pd surfaces. To perform this study we used Viennaab initio Simulation Package (VASP) and Spanish Initiative for Electronic structure with thousands of Atoms (SIESTA) ab initio softwares. To describe all Pd surfaces we selected the (100), and (211) surfaces, because we need very reactive and simple surfaces. Before studying the poison¬ing effect of S we had to study the dissociation of 02 on the surfaces. We discovered that on the (100) surface the hollow site is the most reactive site, but at room temperature the steric hinderace effect occurs very easily. If the molecule has enough vibrational energyit will dissociate. On the (211) surface the (100) micro facet's hollow site is the most reactive site and the molecule dissociates in the site without any barrier, and the molecule drifts from the terrace to this site. An S atom sticks on the Pd (100) surface in the hollow site. It affects the d-band density of states of the nearests Pd atoms; It moves the center of the d-band downin energy, when the bond between the Pd atom and the 0 atom is more antibonding. In the hollow site the S atom also blocks the dissociation site of the molecule. On the Pd(211) surface the energetically favourable site of the S atom is the(100) microfacet's hollow site. There it blocks the most reactive site, but its effect to the Pd atoms next to it is not significant.
Resumo:
Puukuitulujitteisten muovikomposiittien käyttömäärät ovat maailmanlaajuisesti kasvaneet jatkuvasti viimeisen 15 vuoden aikana.Kasvun on ennustettu jatkuvan voimakkaana myös tulevaisuudessa. Diplomityön tavoitteena oli selvittää puukuitulujitteisten muovikomposiittimateriaalien soveltuvuus erääseen, mahdollisesti rakennusteollisuuden käyttöön tulevaan, tuotteeseen. Tutkittaviksi materiaaliyhdistelmiksi valittiin sekä kerta- että kestomuovin ja puu- jauhon seos. Puujauho oli koivupuista sahaus- ja hiontajätettä. Molemmissa tapauksissa puun osuus komposiitissa oli 30 p-%. Koekappaleiden valmistuksessakäytettiin koivupuisia muotteja, joihin materiaali annosteltiin. Kertamuovin japuujauhon seos kovettui huoneenlämmössä. Kestomuovin ja puujauhon seoksen sulatukseen käytettiin lämmitettävillä puristinlevyillä varustettua aihiopuristinta. Koekappaleille määritettiin taivutuslujuudet taivutuskokeen avulla. Koekappaleiden taivutuslujuuksia verrattiin mm. lattialastulevyn ja koivuliimalevyn arvoihin. Liimalevyn taivutuslujuus muihin verrattuna oli huomattavasti suurempi. Komposiittimateriaalista valmistettujen koekappaleiden taivutuslujuus oli lähellä lattia-lastulevyn tasoa, osittain jonkin verran parempikin. Diplomityössä saatujen tulosten perusteella voidaan todeta puukuitulujitteisilla muovikomposiiteilla olevan kehityspotentiaalia myös tutkimuskohteen tyyppisissä ratkaisuissa. Jatkotutkimusta tulisi kohdistaa ennen kaikkea kestomuovipohjaisen komposiittimateriaalinsuuntaan.
Resumo:
PAH (N-(4-aminobenzoyl)glycin) clearance measurements have been used for 50 years in clinical research for the determination of renal plasma flow. The quantitation of PAH in plasma or urine is generally performed by colorimetric method after diazotation reaction but the measurements must be corrected for the unspecific residual response observed in blank plasma. We have developed a HPLC method to specifically determine PAH and its metabolite NAc-PAH using a gradient elution ion-pair reversed-phase chromatography with UV detection at 273 and 265 nm, respectively. The separations were performed at room temperature on a ChromCart (125 mmx4 mm I.D.) Nucleosil 100-5 microm C18AB cartridge column, using a gradient elution of MeOH-buffer pH 3.9 1:99-->15:85 over 15 min. The pH 3.9 buffered aqueous solution consisted in a mixture of 375 ml sodium citrate-citric acid solution (21.01 g citric acid and 8.0 g NaOH per liter), added up with 2.7 ml H3PO4 85%, 1.0 g of sodium heptanesulfonate and completed ad 1000 ml with ultrapure water. The N-acetyltransferase activity does not seem to notably affect PAH clearances, although NAc-PAH represents 10.2+/-2.7% of PAH excreted unchanged in 12 healthy subjects. The performance of the HPLC and the colorimetric method have been compared using urine and plasma samples collected from healthy volunteers. Good correlations (r=0.94 and 0.97, for plasma and urine, respectively) are found between the results obtained with both techniques. However, the colorimetric method gives higher concentrations of PAH in urine and lower concentrations in plasma than those determined by HPLC. Hence, both renal (ClR) and systemic (Cls) clearances are systematically higher (35.1 and 17.8%, respectively) with the colorimetric method. The fraction of PAH excreted by the kidney ClR/ClS calculated from HPLC data (n=143) is, as expected, always <1 (mean=0.73+/-0.11), whereas the colorimetric method gives a mean extraction ratio of 0.87+/-0.13 implying some unphysiological values (>1). In conclusion, HPLC not only enables the simultaneous quantitation of PAH and NAc-PAH, but may also provide more accurate and precise PAH clearance measurements.