876 resultados para Recall-Precision Curves


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study developed percentile curves for anthropometric (waist circumference) and cardiovascular (lipid profile) risk factors for US children and adolescents. STUDY DESIGN: A representative sample of US children and adolescents from the National Health and Nutrition Examination Survey from 1988 to 1994 (NHANES III) and the current national series (NHANES 1999-2006) were combined. Percentile curves were constructed, nationally weighted, and smoothed using the Lambda, Mu, and Sigma method. The percentile curves included age- and sex-specific percentile values that correspond with and transition into the adult abnormal cut-off values for each of these anthropometric and cardiovascular components. To increase the sample size, a second series of percentile curves was also created from the combination of the 2 NHANES databases, along with cross-sectional data from the Bogalusa Heart Study, the Muscatine Study, the Fels Longitudinal Study and the Princeton Lipid Research Clinics Study. RESULTS: These analyses resulted in a series of growth curves for waist circumference, total cholesterol, LDL cholesterol, triglycerides, and HDL cholesterol from a combination of pediatric data sets. The cut-off for abnormal waist circumference in adult males (102 cm) was equivalent to the 94(th) percentile line in 18-year-olds, and the cut-off in adult females (88 cm) was equivalent to the 84(th) percentile line in 18-year-olds. Triglycerides were found to have a bimodal pattern among females, with an initial peak at age 11 and a second at age 20; the curve for males increased steadily with age. The HDL curve for females was relatively flat, but the male curve declined starting at age 9 years. Similar curves for total and LDL cholesterol were constructed for both males and females. When data from the additional child studies were added to the national data, there was little difference in their patterns or rates of change from year to year. CONCLUSIONS: These curves represent waist and lipid percentiles for US children and adolescents, with identification of values that transition to adult abnormalities. They could be used conditionally for both epidemiological and possibly clinical applications, although they need to be validated against longitudinal data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For popular software systems, the number of daily submitted bug reports is high. Triaging these incoming reports is a time consuming task. Part of the bug triage is the assignment of a report to a developer with the appropriate expertise. In this paper, we present an approach to automatically suggest developers who have the appropriate expertise for handling a bug report. We model developer expertise using the vocabulary found in their source code contributions and compare this vocabulary to the vocabulary of bug reports. We evaluate our approach by comparing the suggested experts to the persons who eventually worked on the bug. Using eight years of Eclipse development as a case study, we achieve 33.6\% top-1 precision and 71.0\% top-10 recall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sequential studies of osteopenic bone disease in small animals require the availability of non-invasive, accurate and precise methods to assess bone mineral content (BMC) and bone mineral density (BMD). Dual-energy X-ray absorptiometry (DXA), which is currently used in humans for this purpose, can also be applied to small animals by means of adapted software. Precision and accuracy of DXA was evaluated in 10 rats weighing 50-265 g. The rats were anesthetized with a mixture of ketamine-xylazine administrated intraperitoneally. Each rat was scanned six times consecutively in the antero-posterior incidence after repositioning using the rat whole-body software for determination of whole-body BMC and BMD (Hologic QDR 1000, software version 5.52). Scan duration was 10-20 min depending on rat size. After the last measurement, rats were sacrificed and soft tissues were removed by dermestid beetles. Skeletons were then scanned in vitro (ultra high resolution software, version 4.47). Bones were subsequently ashed and dissolved in hydrochloric acid and total body calcium directly assayed by atomic absorption spectrophotometry (TBCa[chem]). Total body calcium was also calculated from the DXA whole-body in vivo measurement (TBCa[DXA]) and from the ultra high resolution measurement (TBCa[UH]) under the assumption that calcium accounts for 40.5% of the BMC expressed as hydroxyapatite. Precision error for whole-body BMC and BMD (mean +/- S.D.) was 1.3% and 1.5%, respectively. Simple regression analysis between TBCa[DXA] or TBCa[UH] and TBCa[chem] revealed tight correlations (n = 0.991 and 0.996, respectively), with slopes and intercepts which were significantly different from 1 and 0, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Person-to-stock order picking is highly flexible and requires minimal investment costs in comparison to automated picking solutions. For these reasons, tradi-tional picking is widespread in distribution and production logistics. Due to its typically large proportion of manual activities, picking causes the highest operative personnel costs of all intralogistics process. The required personnel capacity in picking varies short- and mid-term due to capacity requirement fluctuations. These dynamics are often balanced by employing minimal permanent staff and using seasonal help when needed. The resulting high personnel fluctuation necessitates the frequent training of new pickers, which, in combination with in-creasingly complex work contents, highlights the im-portance of learning processes in picking. In industrial settings, learning is often quantified based on diminishing processing time and cost requirements with increasing experience. The best-known industrial learning curve models include those from Wright, de Jong, Baloff and Crossman, which are typically applied to the learning effects of an entire work crew rather than of individuals. These models have been validated in largely static work environments with homogeneous work contents. Little is known of learning effects in picking systems. Here, work contents are heterogeneous and individual work strategies vary among employees. A mix of temporary and steady employees with varying degrees of experience necessitates the observation of individual learning curves. In this paper, the individual picking performance development of temporary employees is analyzed and compared to that of steady employees in the same working environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Optical scanners combined with computer-aided design and computer-aided manufacturing (CAD/CAM) technology provide high accuracy in the fabrication of titanium (TIT) and zirconium dioxide (ZrO) bars. The aim of this study was to compare the precision of fit of CAD/CAM TIT bars produced with a photogrammetric and a laser scanner. METHODS Twenty rigid CAD/CAM bars were fabricated on one single edentulous master cast with 6 implants in the positions of the second premolars, canines and central incisors. A photogrammetric scanner (P) provided digitized data for TIT-P (n=5) while a laser scanner (L) was used for TIT-L (n=5). The control groups consisted of soldered gold bars (gold, n=5) and ZrO-P with similar bar design. Median vertical distance between implant and bar platforms from non-tightened implants (one-screw test) was calculated from mesial, buccal and distal scanning electron microscope measurements. RESULTS Vertical microgaps were not significantly different between TIT-P (median 16μm; 95% CI 10-27μm) and TIT-L (25μm; 13-32μm). Gold (49μm; 12-69μm) had higher values than TIT-P (p=0.001) and TIT-L (p=0.008), while ZrO-P (35μm; 17-55μm) exhibited higher values than TIT-P (p=0.023). Misfit values increased in all groups from implant position 23 (3 units) to 15 (10 units), while in gold and TIT-P values decreased from implant 11 toward the most distal implant 15. SIGNIFICANCE CAD/CAM titanium bars showed high precision of fit using photogrammetric and laser scanners. In comparison, the misfit of ZrO bars (CAM/CAM, photogrammetric scanner) and soldered gold bars was statistically higher but values were clinically acceptable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article addresses the issue of kriging-based optimization of stochastic simulators. Many of these simulators depend on factors that tune the level of precision of the response, the gain in accuracy being at a price of computational time. The contribution of this work is two-fold: first, we propose a quantile-based criterion for the sequential design of experiments, in the fashion of the classical expected improvement criterion, which allows an elegant treatment of heterogeneous response precisions. Second, we present a procedure for the allocation of the computational time given to each measurement, allowing a better distribution of the computational effort and increased efficiency. Finally, the optimization method is applied to an original application in nuclear criticality safety. This article has supplementary material available online. The proposed criterion is available in the R package DiceOptim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare the precision of fit of full-arch implant-supported screw-retained computer-aided designed and computer-aided manufactured (CAD/CAM) titanium-fixed dental prostheses (FDP) before and after veneering. The null-hypothesis was that there is no difference in vertical microgap values between pure titanium frameworks and FDPs after porcelain firing. MATERIALS AND METHODS Five CAD/CAM titanium grade IV frameworks for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI tooth positions 15, 13, 11, 21, 23, 25) were fabricated after digitizing the implant platforms and the cuspid-supporting framework resin pattern with a laser scanner (CARES(®) Scan CS2; Institut Straumann AG, Basel, Switzerland). A bonder, an opaquer, three layers of porcelain, and one layer of glaze were applied (Vita Titankeramik) and fired according to the manufacturer's preheating and fire cycle instructions at 400-800°C. The one-screw test (implant 25 screw-retained) was applied before and after veneering of the FDPs to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from interproximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS All vertical microgaps were clinically acceptable with values <90 μm. No statistically significant pairwise difference (P = 0.98) was observed between the relative effects of vertical microgap of unveneered (median 19 μm; 95% CI 13-35 μm) and veneered FDPs (20 μm; 13-31 μm), providing support for the null-hypothesis. Analysis within the groups showed significantly different values between the five implants of the FDPs before (P = 0.044) and after veneering (P = 0.020), while a monotonous trend of increasing values from implant 23 (closest position to screw-retained implant 25) to 15 (most distant implant) could not be observed (P = 0.169, P = 0.270). CONCLUSIONS Full-arch CAD/CAM titanium screw-retained frameworks have a high accuracy. Porcelain firing procedure had no impact on the precision of fit of the final FDPs. All implant microgap measurements of each FDP showed clinically acceptable vertical misfit values before and after veneering. Thus, the results do not only show accurate performance of the milling and firing but show also a reproducible scanning and designing process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Empirical research has illustrated an association between study size and relative treatment effects, but conclusions have been inconsistent about the association of study size with the risk of bias items. Small studies give generally imprecisely estimated treatment effects, and study variance can serve as a surrogate for study size. METHODS We conducted a network meta-epidemiological study analyzing 32 networks including 613 randomized controlled trials, and used Bayesian network meta-analysis and meta-regression models to evaluate the impact of trial characteristics and study variance on the results of network meta-analysis. We examined changes in relative effects and between-studies variation in network meta-regression models as a function of the variance of the observed effect size and indicators for the adequacy of each risk of bias item. Adjustment was performed both within and across networks, allowing for between-networks variability. RESULTS Imprecise studies with large variances tended to exaggerate the effects of the active or new intervention in the majority of networks, with a ratio of odds ratios of 1.83 (95% CI: 1.09,3.32). Inappropriate or unclear conduct of random sequence generation and allocation concealment, as well as lack of blinding of patients and outcome assessors, did not materially impact on the summary results. Imprecise studies also appeared to be more prone to inadequate conduct. CONCLUSIONS Compared to more precise studies, studies with large variance may give substantially different answers that alter the results of network meta-analyses for dichotomous outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reasons for the development and collapse of Maya civilization remain controversial and historical events carved on stone monuments throughout this region provide a remarkable source of data about the rise and fall of these complex polities. Use of these records depends on correlating the Maya and European calendars so that they can be compared with climate and environmental datasets. Correlation constants can vary up to 1000 years and remain controversial. We report a series of high-resolution AMS C-14 dates on a wooden lintel collected from the Classic Period city of Tikal bearing Maya calendar dates. The radiocarbon dates were calibrated using a Bayesian statistical model and indicate that the dates were carved on the lintel between AD 658-696. This strongly supports the Goodman-Martinez-Thompson (GMT) correlation and the hypothesis that climate change played an important role in the development and demise of this complex civilization.