945 resultados para Polyethylene Glycol
Resumo:
The aim of the work was to evaluate the performance of four cultivars of iceberg lettuce, in a greenhouse, with and without ground cover. The experimental design adopted was that of subdivided parcels, where parcels were provided with and without ground cover consisting of black polyethylene and the subparcels consisted of the cultivars. There were three repetitions per treatment and six central plants of each parcel were evaluated. Drip irrigation was utilized. The cultivars studied were: 'Laurel', 'AF-389', 'Mayara' and 'Tainá'. The seeds were planted in Styrofoam trays with 288 cells containing the substrate Plantmax Hortaliças® A. The trays were kept in a greenhouse until transplanting, 25 days after seeding. The parameters examined were: fresh weight of the aerial part per plant, longitudinal (DL) and transverse (DT) diameters of the head, height of the plant and mean number of leaves per plant. Only among the cultivars there were significant differences in transverse and longitudinal diameters of the head and height of the plant. No significant interactions were detected between ground cover and cultivars. With regard to longitudinal and transverse diameters, 'AF-839' (DL = 27.11 cm; DT = 24.53 cm) showed smaller diameters than those of 'Laurel' (DL = 31.13 cm; DT = 30.55 cm), but did not differ from the other cultivars. In regard to height of the plants, 'Laurel' (20.66 cm) had the greatest value and 'AF-839' (16.02 cm) the lowest. The cultivars did not differ with respect to mean number of leaves and fresh weight of the aerial part of the plant. It is concluded that there were no significant differences in the cultivation of the iceberg lettuce with and without ground cover. The cultivar 'Laurel' stood out with respect to longitudinal and transverse diameters and height of the plant, only differing from the 'AF-839' with regard to the diameters.
Resumo:
The purpose of this study was to evaluate in vivo the biocompatibility of Endométhasone, Pulp Canal Sealer EWT and AHPlus root canal sealers after implantation in rat connective tissue. Twenty-four Wistar-Furth rats were used. Polyethylene tubes were filled with the sealers and implanted into specific dorsal subdermal tissue sites of the rats. Implants were removed after 3, 7 and 30 days, fixed and processed for glycol methacrylate-embedding technique to be examined microscopically. On the 3rd day, there was a mild inflammatory reaction to Pulp Canal Sealer EWT implants, but a severe response to the other sealers with presence of acute inflammatory cells. On the 7th day, tissue organization was more evident with attenuation of the inflammatory reaction, especially for the AH-Plus implants. On the 30th day, connective tissue with few inflammatory cells was observed in contact with all sealer implants. In this time interval, the tissue in contact with Pulp Canal Sealer EWT implants was more organized, while the tissue close to Endométhasone and AH-Plus implants showed a mild persistent inflammatory reaction and had similar results to each other. In conclusion, the sealers had a similar pattern of irritation, which was more severe in the beginning and milder with time, in such a way that all sealers showed a persistent mild reaction. Pulp Canal Sealer EWT yielded better tissue organization than Endométhasone and AH-Plus, which, in turn, showed similar results to each other.
Resumo:
Purpose: To evaluate the histological and systemic response to subcutaneous injection of polyethylene gel in rats. Methods: Twenty-one white male rats were divided into 3 groups (G): G1 and G2 received subcutaneous polyethylene gel injection in the dorsal midline and were sacrificed at 30 and 60 postoperative days, respectively. G3 was not exposed to the polyethylene gel and was sacrificed after 60 days. Blood levels of lactate dehydrogenase (LDH), creatine kinase (CK), and alkaline phosphatase (ALP) were evaluated. The heart, kidney, liver, adrenal gland, injection site, and adjacent tissues were histologically examined. The results were submitted to statistical analysis. Results: There was no clinical evidence of extrusion, reduction of the injected volume, or abnormalities in the adjacent tissues. Blood levels of CK and LDH were normal and similar in all groups. ALP levels were significantly lower in G2 than in G1 and G3. The systemic organs were normal on histological examination in the 3 groups evaluated. Microscopically, the polyethylene gel was surrounded by a thin pseudocapsule formation and minimal inflammatory cell response, which decreased from G1 to G2. Conclusion: The subcutaneous injection of polyethylene gel in rats elicited minimal local inflammatory response and no systemic side effects. Copyright © 2008 Informa Healthcare USA, Inc.
Resumo:
This aim of this study was to investigate the biocompatibility of two experimental acetazolamide (AZ)-based pastes in the subcutaneous tissue of rats. Both pastes contained AZ as the main component in similar concentration. The vehicle in experimental paste 1 was saline, while experimental paste 2 was prepared with propylene glycol. Sixty polyethylene tubes were sealed at one end with gutta-percha (GP), which served as a control. Half of the tubes were flled with paste 1 and half with paste 2. The tubes were implanted in the subcutaneous tissue of 15 rats, being 4 tubes for each animal. The animals were killed 7, 15 and 45 days after surgery and the specimens were processed in laboratory. The histological sections were stained with hematoxylin and eosin and were analyzed by light microscopy. Scores were assigned to level of infammatory process: 1- none; 2- mild; 3- moderate; 4- severe. The data were analyzed statistically by the Kruskal-Wallis test (p≤0.05). Paste 1 produced an infammatory process at 7 days. However, the intensity of this infammation decreased with time and was nearly absent at 45 days. No statistically signifcant difference (p>0.05) was observed between the control (GP) and paste 1. However, paste 2 produced infammatory response at all study periods and differed signifcantly (p<0.05) from the control. In conclusion, in the present study, the experimental AZ-based paste 1 was considered as biocompatible as the control matrial (GP), while experimental paste 2 was irritating to rat subcutaneous tissue.
Resumo:
This paper presents results from stress cracking (SC) tests performed in both fresh and exposed high density polyethylene (HDPE) geomembranes (GM). The HDPE GMs were exposed to ultraviolet radiation, thermal aging (air oven) and tested for chemical compatibility with sodium hydroxide. Stress cracking tests in both fresh and degraded samples were performed in accordance to ASTM D5397: Notched Constant Tensile Load Test (NCTL) and Single Point-Notched Constant Tensile Load Test (SP-NCTL). The results of the NCTL showed that the geomembrane degradation process can be considered to be a catalyst for the phenomenon of SC because it caused a 50% to 60% reduction in stress crack resistance. The most resistance reduction was observed for the sample under chemical compatibility with sodium hydroxide. For the SP-NCTL, the results showed that the samples maintain the same trend verified in the NCTL. The largest resistance reduction was evidenced in samples undergoing ultraviolet degradation. © 2012 ejge.
Resumo:
This paper presents the results of thermogravimetric analysis (TGA) tests in PVC (1.0; 2.0 mm) and HDPE (0.8; 2.5 mm) geomembranes exposed to weathering and leachate after 30 months. The aim of this paper is the comparison of fresh and exposed samples to assess the degradation process concerning the total loss of mass of geomembranes. The exposure was conducted in accordance with the recommendations of ASTM standards. The TGA tests were carried out according to ASTM D6370 and E2105. Results show, for instance, that for PVC geomembrane the largest reductions of plasticizers occurred for samples exposed to weathering. The loss of plasticizers after the exposure contributed to the decrease of deformation and consequent increase in stiffness. TGA tests shows to be a valuable tool to control the quality of the materials. © 2012 ejge.
Resumo:
Aims and objectives: The behavior of polymer-matrix composite is dependent on the degree of conversion. The aim of this study was to evaluate the degree of conversion of two resin cements following storage at 37°C immediately, 24 and 48 hours, and 7 days after light-curing by FTIR analysis. Materials and methods: The specimens were made in a metallic mold and cured with blue LED with power density of 500 mW/cm2 for 30 seconds. The specimens were pulverized, pressed with KBr and analyzed with FTIR following storage times. Statistical analysis used: ANOVA (two-way) and Tukey's post hoc. Results: To the polymer-matrix composites between 24 and 48 hours does not show a significant increase (p > 0.05), however, the highest values were found after 7 days. Conclusion: The polymer-matrix composites used in this study showed similarity on the degree of conversion and increased of according to the time of storage.
Resumo:
Plasma treatments were applied on the surface of postconsumer polyethylene terephthalate (PET) bottles to increase their wettability and hasten the subsequent hydrolysis process. Sixty-four treatments were tested by varying plasma composition (oxygen and air), power (25-130 W), pressure (50-200 mTorr), and time (1 and 5 min). The best treatment was the one applied in air plasma at 130 W and 50 mTorr for 5 min, as it provided the lowest contact angle, 9.4°. Samples of PET before and after the optimized plasma condition were subjected to hydrolysis at 205°C. Although the treatment changed only a thin surface layer, its influence was evident up to relatively high conversion rates, as the treated samples presented more than 40% higher conversion rates than the untreated ones after 2 h of reaction. Infrared spectroscopy showed that the terephthalic acid obtained from 99% of depolymerization was similar to the commercial product used in PET synthesis. © 2012 Wiley Periodicals, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: The combination of sodium hypochlorite (NaOCl) and chlorhexidine (CHX) yields a precipitate potentially toxic (PPT). The aim of this study was to evaluate the tissue response to implanted polyethylene tubes filled with PPT-soaked fibrin sponge. Methods: Forty rats received four polyethylene tubes each; each tube was filled with fibrin sponge soaked by 2.5 % NaOCl, 2.0 % CHX, PPT (2.5 % NaOCl plus 2.0 % CHX), or not soaked (control). The observation time points were 7, 15, 30, 60, and 90 days. At each time point, eight animals were killed, and the tubes and surrounding tissues were removed, fixed, and prepared for light microscopic analysis by performing glycol methacrylate embedding, serial cutting into 3-μm sections, and hematoxylin-eosin staining. Qualitative and quantitative evaluations of the reactions were performed. Results were statistically analyzed by Kruskal-Wallis test (p < 0.05). Results: All chemical solutions caused moderate reactions at 7 days. On day 30, PPT group was more cytotoxic than the control group and the CHX group (p < 0.05). On days 15 and 60, PPT group was more cytotoxic than the control group (p < 0.05). On day 90, there was no statistically significant difference between the different groups. Conclusion: PPT is more cytotoxic than NaOCl and CHX alone, particularly in the short term. Clinical significance: Protocols which suggest the use of CHX and NaOCl must be revised because this mixture produces cytotoxic product. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O experimento foi realizado na área experimental do Departamento de Engenharia Rural da Faculdade de Ciências Agronômicas – Unesp/Botucatu, Estado de São Paulo, em duas estufas dispostas em diferentes orientações geográficas, Leste/Oeste e Norte/Sul. A alface (Lactuva sativa L.) cv. Elisa foi cultivada em ambas estufas, sendo semeada em 05/05/99, transplantada em 29/05/99 e colhida em 31/06/99. Utilizou-se tensiômetros para monitorar o potencial de água no solo para realizar o manejo do sistema de irrigação por gotejamento. Microevaporímetros eqüidistantes de 3 m e colocados em 3 alturas, 0.50, 1.00 e 1.50 m, termohigrógrafos e tanques Classe “A” foram instalados nas duas estufas. Através de análise geoestatística, não se observou dependência espacial nem variabilidade espacial da evaporação nas duas estufas. Entretanto, a altura dos evaporímetros apresentou diferenças significativas: a evaporação à altura de 1.50 foi menor que nas outras duas.As médias de temperatura, umidade relativa e déficit de pressão de vapor do arnão diferiram estatisticamente entre as estufas e o ambiente externo. Os valores médios de evaporação de água no tanque Classe A instalado fora das estufas diferiram estatisticamente quando comparados com os instalados no interior das estufas, porém, entre as orientações não se constatou diferença significativa. Pôde-se verificar que não houve diferença significativa das características agronômicas da alface em ambas orientações estudadas. No entanto, houve diferença significativa para essas características entre os canteiros no interior das mesmas, havendo variância espacial para os dados de matéria fresca apenas na estufa N/S.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper presents results describing the physical, mechanical, and thermal properties (melt flow index - MFI and oxidative induction time - OIT) of high density polyethylene and poly (vinyl chloride) after weathering exposure (6, 12, 18, and 30 months). The materials exposed were geomembranes of two thicknesses: 1.0 and 2.0 mm (PVC) and 0.8 and 2.5 mm (HDPE). The climate parameters (average) obtained were 25 degrees C (temperature), 93 mm (precipitation), 66% (relative humidity), and 19 MJ/m(2). day (intensity of global radiation). Some results showed, for instance, that the behavior of the geomembranes changed after the exposures. A few minor variations in physical properties occurred. The density and thickness, for instance, varied 0.5-1.0% (average) for both the PVC and HDPE geomembranes. The mechanical properties changed as a function of the period of exposure. In general, some decreases were verified by the deformation of PVC. The samples became more rigid. In contrast, HDPE geomembranes became more ductile. Despite the variations in elasticity, some increases in deformability were verified. An MFI test showed some degradation in HDPE geomembranes. OIT tests revealed small values for both intact and exposed samples.