1000 resultados para Pneumoperitônio, Gás carbônico, Sepse, Acidose, Leucócitos
Resumo:
The gas turbine (GT) is known to have: low cost of capital over the amount of energy, high flexibility, high reliability, short delivery time, commissioning and commercial operation at the beginning and quick departure. The gas turbine is also recognized for its superior environmental performance, manifested in air pollution containment and reducing greenhouse gases (Mahi, 1994). Gas turbines in simple cycle mode (SC) have long been used by utilities to limited power generation peak. In addition, manufacturing facilities use gas turbines for power generation units on site, often in combination with the process of heat production, such as hot water and steam process. In recent years, the performance of industrial gas turbines has been improved due to significant investments in research and development, in terms of fuel to electricity conversion efficiency, plant capacity, availability and reliability. The greater availability of energy resources such as natural gas (NG), the significant reduction of capital costs and the introduction of advanced cycles, have also been a success factor for the increased use of gas turbines to load applications base (Poulikas, 2004). Open Cycle Gas Turbine with a greater degree of heat to the atmosphere may alternatively be used to produce additional electricity using a steam cycle, or to compose a cogeneration process. The combined cycle (CC) uses the heat from the gas turbine exhaust gas to increase the power output and increase the overall efficiency of more than 50% second (Najjar, 2001). The initial discovery of these cycles in the commercial power generation market was possible due to the development of the gas turbine. Only from the 1970s that gas turbine inlet temperature and therefore the exhaust gas temperature was sufficiently high to allow a better efficiency in the combined cycle ... (Complete Abstract click electronic access below)
Resumo:
In this work we have developed an apparatus in order to study the capture of asteroids by planets surrounded by a gas envelope during y-by, to do this we have brought an innovation by using a hydrodynamical gas. We began such project by studying particles trajectories with a code based on the analytical gas. After being used to this model we have started a process to elaborate a code which uses the gas in a numerical way. The hydrodynamical gas is described by equations which are not solved analytically. Therefore, it was used an algorithm able to model the gas by keeping all information of the gas in cells. Thus we have made a code to read such cell`s information and then to solve all calculations. Once this process is done, the program inform us all date about the simulated trajectories
Resumo:
This paper presents a study based on literature and examples found on literature of the potential of petroleum gas to be used as a primary source to generate electricity. The steady increase electricity demand in Brazil makes desirable an effective use of all available primary sources, combined with this need the momentum of the country with the discovery of the presalt reserves becomes interesting the use of this gas, often wasted, for generating electricity. The electricity generation in this work is illustrated by the cogeneration in oil refining plants that have the combined cycle thermal operation. The ultimate goal is to provide a text to identify the advantages, disadvantages and trends of this type of generation
Resumo:
On the grounds of the great advances achieved over recent years, the process HF/ERW (High-Frequency/Electric Resistance Welding)welded pipe have played an active role in the oil and gas industry for deep water applications, at high and extremely low temperatures, under high pressure and in highly corrosive environments, gradually replacing manufactured pipes by other processes. However, studies have shown that defects in the welded joints are a the leading causes of pipelines failures, which has required the determination of toughness values in this region, in compliance with the strict recommendations of the codes and standards with manufacturers and construction companies, on the oil and gas sector. As part of the validation process required toughness values, this research project focuses on a microstructural analysis in HF / ERW tubes microalloyed, steel grade API 5CT N80, designed to explore oil and gas in deep waters, the subject of strategic relevance to the country because of the recent discoveries in the Santos mega fields: Tupi and Libra (pre-salt). In this scientific work will be presented and discussed the results of mechanical tensile and Charpy, a few CTOD tests curves (showing the trend of toughness values to be obtained), and the microstructures of the base material obtained by optical microscopy, with special emphasis on the formation of non-metallic inclusions in the welded joint
Resumo:
Pós-graduação em Design - FAAC
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Física - IGCE
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
The effect of physical exercise in immune function has been extensively studied. The intensity and duration of physical exercise have considerable influence in immunologic parameters. However, few studies have compared different exercise intensities in different stages of a physical training program. Thus, the aim of this study was to verify the metabolic, hormonal and immunologic changes before and after acute intermittent swimming exercise, following different stages of training program. Seventeen male swimmers were evaluated in three stages of training. The intensity of the three sessions was 90% (anaerobic potency – PAN), 70% (aerobic potency - PAE) and 98% (lactate tolerance – TLA) of the maximal speed from the best time of the distance, resulted from peak performance in competition. Blood samples were collected pre and immediately after exercise for cells counting and measurement of substrates and cortisol concentrations. It was used ANOVA to verify the significance of difference (p<0.05). There was a significant increase of glucose and cortisol post exercise in the PAN and PAE sessions. Glutamine increased significantly in PAE and TLA. Leukocytes increased significantly after the three different sessions and lymphocytes decreased significantly on PAE and TLA. In conclusion, it was demonstrated that changes of the several parameters studied in different stages of training program can cause temporary alterations in immune cells and may compromise resistance to common minor illnesses and athlete performance.