934 resultados para Pharmaceutical Vehicles


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reduction of luvastatin (FLV) at a hanging mercury-drop electrode (HMDE) was studied by square-wave adsorptive-stripping voltammetry (SWAdSV). FLV can be accumulated and reduced at the electrode, with a maximum peak current intensity at a potential of approximately 1.26V vs. AgCl=Ag, in an aqueous electrolyte solution of pH 5.25. The method shows linearity between peak current intensity and FLV concentration between 1.0 10 8 and 2.7 10 6 mol L 1. Limits of detection (LOD) and quantification (LOQ) were found to be 9.9 10 9 mol L 1 and 3.3 10 8 mol L 1, respectively. Furthermore, FLV oxidation at a glassy carbon electrode surface was used for its hydrodynamic monitoring by amperometric detection in a flow-injection system. The amperometric signal was linear with FLV concentration over the range 1.0 10 6 to 1.0 10 5 mol L 1, with an LOD of 2.4 10 7 mol L 1 and an LOQ of 8.0 10 7 mol L 1. A sample rate of 50 injections per hour was achieved. Both methods were validated and showed to be precise and accurate, being satisfactorily applied to the determination of FLV in a commercial pharmaceutical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A square wave voltammetric (SWV) method and a flow injection analysis systemwi th electrochemical detection (FIA-EC) using a glassy carbon electrode were evaluated for the determination of codeine in pharmaceutical preparations. The interference of several compounds, such as acetaminophen,guaiacol, parabens, ephedrine, acetylsalicylic acid and caffeine, that usually appear associated with codeine pharmaceutical preparations was studied. It was verified that these electroanalytical methods could not be used with acetaminophen present in the formulations and that with guaiacol, parabens or ephedrine present the use of the FIA-EC system was impracticable. A detection limit of 5 µmol L- 1 and a linear calibration range from 40 to 140 µmol L- 1 was obtained with the SWV method. For the flow injection analysis procedure a linear calibration range was obtained from 7 to 50 µmol L- 1 with a detection limit of 3 µmol L- 1 and the FIA-EC systemallowed a sampling rate of 115 samples per hour. The results obtained by the two methods, SWV and FIA-EC, were compared with those obtained using reference methods and demonstrated good agreement, with relative deviations lower than 4%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aiming the establishment of simple and accurate readings of citric acid (CA) in complex samples, citrate (CIT) selective electrodes with tubular configuration and polymeric membranes plus a quaternary ammonium ion exchanger were constructed. Several selective membranes were prepared for this purpose, having distinct mediator solvents (with quite different polarities) and, in some cases, p-tert-octylphenol (TOP) as additive. The latter was used regarding a possible increase in selectivity. The general working characteristics of all prepared electrodes were evaluated in a low dispersion flow injection analysis (FIA) manifold by injecting 500µl of citrate standard solutions into an ionic strength (IS) adjuster carrier (10−2 mol l−1) flowing at 3ml min−1. Good potentiometric response, with an average slope and a repeatability of 61.9mV per decade and ±0.8%, respectively, resulted from selective membranes comprising additive and bis(2-ethylhexyl)sebacate (bEHS) as mediator solvent. The same membranes conducted as well to the best selectivity characteristics, assessed by the separated solutions method and for several chemical species, such as chloride, nitrate, ascorbate, glucose, fructose and sucrose. Pharmaceutical preparations, soft drinks and beers were analyzed under conditions that enabled simultaneous pH and ionic strength adjustment (pH = 3.2; ionic strength = 10−2 mol l−1), and the attained results agreed well with the used reference method (relative error < 4%). The above experimental conditions promoted a significant increase in sensitivity of the potentiometric response, with a supra-Nernstian slope of 80.2mV per decade, and allowed the analysis of about 90 samples per hour, with a relative standard deviation <1.0%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ramsey pricing has been proposed in the pharmaceutical industry as a principle to price discriminate among markets while allowing to recover the (fixed) R&D cost. However, such analyses neglect the presence of insurance or the fund raising costs for most of drug reimbursement. By incorporating these new elements, we aim at providing some building blocks towards an economic theory incorporating Ramsey pricing and insurance coverage. We show how coinsurance affects the optimal prices to pay for the R&D investment. We also show that under certain conditions, there is no strategic incentive by governments to set coinsurance rates in order to shift the financial burden of R&D. This will have important implications to the application of Ramsey pricing principles to pharmaceutical products across countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Janssen-Cilag proposal for a risk-sharing agreement regarding bortezomib received a welcome signal from NICE. The Office of Fair Trading report included risk-sharing agreements as an available tool for the National Health Service. Nonetheless, recent discussions have somewhat neglected the economic fundamentals underlying risk-sharing agreements. We argue here that risk-sharing agreements, although attractive due to the principle of paying by results, also entail risks. Too many patients may be put under treatment even with a low success probability. Prices are likely to be adjusted upward, in anticipation of future risk-sharing agreements between the pharmaceutical company and the third-party payer. An available instrument is a verification cost per patient treated, which allows obtaining the first-best allocation of patients to the new treatment, under the risk sharing agreement. Overall, the welfare effects of risk-sharing agreements are ambiguous, and care must be taken with their use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The energy resource scheduling is becoming increasingly important, as the use of distributed resources is intensified and massive gridable vehicle (V2G) use is envisaged. This paper presents a methodology for day-ahead energy resource scheduling for smart grids considering the intensive use of distributed generation and V2G. The main focus is the comparison of different EV management approaches in the day-ahead energy resources management, namely uncontrolled charging, smart charging, V2G and Demand Response (DR) programs i n the V2G approach. Three different DR programs are designed and tested (trip reduce, shifting reduce and reduce+shifting). Othe r important contribution of the paper is the comparison between deterministic and computational intelligence techniques to reduce the execution time. The proposed scheduling is solved with a modified particle swarm optimization. Mixed integer non-linear programming is also used for comparison purposes. Full ac power flow calculation is included to allow taking into account the network constraints. A case study with a 33-bus distribution network and 2000 V2G resources is used to illustrate the performance of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of Electric Vehicles (EVs) will change significantly the planning and management of power systems in a near future. This paper proposes a real-time tariff strategy for the charge process of the EVs. The main objective is to evaluate the influence of real-time tariffs in the EVs owners’ behaviour and also the impact in load diagram. The paper proposes the energy price variation according to the relation between wind generation and power consumption. The proposed strategy was tested in two different days in the Danish power system. January 31st and August 13th 2013 were selected because of the high quantities of wind generation. The main goal is to evaluate the changes in the EVs charging diagram with the energy price preventing wind curtailment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy resource scheduling is becoming increasingly important, as the use of distributed resources is intensified and of massive electric vehicle is envisaged. The present paper proposes a methodology for day-ahead energy resource scheduling for smart grids considering the intensive use of distributed generation and Vehicle-to-Grid (V2G). This method considers that the energy resources are managed by a Virtual Power Player (VPP) which established contracts with their owners. It takes into account these contracts, the users' requirements subjected to the VPP, and several discharge price steps. The full AC power flow calculation included in the model takes into account network constraints. The influence of the successive day requirements on the day-ahead optimal solution is discussed and considered in the proposed model. A case study with a 33-bus distribution network and V2G is used to illustrate the good performance of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents a framework to an Industrial Engineering and Management Science course from School of Management and Industrial Studies using Autonomous Ground Vehicles (AGV) to supply materials to a production line as an experimental setup for the students to acquire knowledge in the production robotics area. The students must be capable to understand and put into good use several concepts that will be of utmost importance in their professional life such as critical decisions regarding the study, development and implementation of a production line. The main focus is a production line using AGVs, where the students are required to address several topics such as: sensors actuators, controllers and an high level management and optimization software. The presented framework brings to the robotics teaching community methodologies that allow students from different backgrounds, that normally don’t experiment with the robotics concepts in practice due to the big gap between theory and practice, to go straight to ”making” robotics. Our aim was to suppress the minimum start point level thus allowing any student to fully experience robotics with little background knowledge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present a set of field tests for detection of human in the water with an unmanned surface vehicle using infrared and color cameras. These experiments aimed to contribute in the development of victim target tracking and obstacle avoidance for unmanned surface vehicles operating in marine search and rescue missions. This research is integrated in the work conducted in the European FP7 research project Icarus aiming to develop robotic tools for large scale rescue operations. The tests consisted in the use of the ROAZ unmanned surface vehicle equipped with a precision GPS system for localization and both visible spectrum and IR cameras to detect the target. In the experimental setup, the test human target was deployed in the water wearing a life vest and a diver suit (thus having lower temperature signature in the body except hands and head) and was equipped with a GPS logger. Multiple target approaches were performed in order to test the system with different sun incidence relative angles. The experimental setup, detection method and preliminary results from the field trials performed in the summer of 2013 in Sesimbra, Portugal and in La Spezia, Italy are also presented in this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Estatística e Gestão de Informação

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breakthrough technologies which now enable the sequencing of individual genomes will irreversibly modify the way diseases are diagnosed, predicted, prevented and treated. For these technologies to reach their full potential requires, upstream, access to high-quality biomedical data and samples from large number of properly informed and consenting individuals and, downstream, the possibility to transform the emerging knowledge into a clinical utility. The Lausanne Institutional Biobank was designed as an integrated, highly versatile infrastructure to harness the power of these emerging technologies and catalyse the discovery and development of innovative therapeutics and biomarkers, and advance the field of personalised medicine. Described here are its rationale, design and governance, as well as parallel initiatives which have been launched locally to address the societal, ethical and technological issues associated with this new bio-resource. Since January 2013, inpatients admitted at Lausanne CHUV University Hospital have been systematically invited to provide a general consent for the use of their biomedical data and samples for research, to complete a standardised questionnaire, to donate a 10-ml sample of blood for future DNA extraction and to be re-contacted for future clinical trials. Over the first 18 months of operation, 14,459 patients were contacted, and 11,051 accepted to participate in the study. This initial 18-month experience illustrates that a systematic hospital-based biobank is feasible; it shows a strong engagement in research from the patient population in this University Hospital setting, and the need for a broad, integrated approach for the future of medicine to reach its full potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les nanotechnologies appliquées aux sciences pharmaceutiques ont pour but d’améliorer l’administration de molécules actives par l’intermédiaire de transporteurs nanométriques. Parmi les différents types de véhicules proposés pour atteindre ce but, on retrouve les nanoparticules polymériques (NP) constituées de copolymères “en bloc”. Ces copolymères permettent à la fois l’encapsulation de molécules actives et confèrent à la particule certaines propriétés de surface (dont l’hydrophilicité) nécessaires à ses interactions avec les milieux biologiques. L’architecture retenue pour ces copolymères est une structure constituée le plus fréquemment de blocs hydrophiles de poly(éthylène glycol) (PEG) associés de façon linéaire à des blocs hydrophobes de type polyesters. Le PEG est le polymère de choix pour conférer une couronne hydrophile aux NPs et son l’efficacité est directement liée à son organisation et sa densité de surface. Néanmoins, malgré les succès limités en clinique de ces copolymères linéaires, peu de travaux se sont attardés à explorer les effets sur la structure des NPs d’architectures alternatives, tels que les copolymères en peigne ou en brosse. Durant ce travail, plusieurs stratégies ont été mises au point pour la synthèse de copolymères en peigne, possédant un squelette polymérique polyesters-co-éther et des chaines de PEG liées sur les groupes pendants disponibles (groupement hydroxyle ou alcyne). Dans la première partie de ce travail, des réactions d’estérification par acylation et de couplage sur des groupes pendants alcool ont permis le greffage de chaîne de PEG. Cette méthode génère des copolymères en peigne (PEG-g-PLA) possédant de 5 à 50% en poids de PEG, en faisant varier le nombre de chaînes branchées sur un squelette de poly(lactique) (PLA). Les propriétés structurales des NPs produites ont été étudiées par DLS, mesure de charge et MET. Une transition critique se situant autour de 15% de PEG (poids/poids) est observée avec un changement de morphologie, d’une particule solide à une particule molle (“nanoagrégat polymére”). La méthode de greffage ainsi que l’addition probable de chaine de PEG en bout de chaîne principale semblent également avoir un rôle dans les changements observés. L’organisation des chaînes de PEG-g-PLA à la surface a été étudiée par RMN et XPS, méthodes permettant de quantifier la densité de surface en chaînes de PEG. Ainsi deux propriétés clés que sont la résistance à l’agrégation en conditions saline ainsi que la résistance à la liaison aux protéines (étudiée par isothermes d’adsorption et microcalorimétrie) ont été reliées à la densité de surface de PEG et à l’architecture des polymères. Dans une seconde partie de ce travail, le greffage des chaînes de PEG a été réalisé de façon directe par cyclo-adition catalysée par le cuivre de mPEG-N3 sur les groupes pendants alcyne. Cette nouvelle stratégie a été pensée dans le but de comprendre la contribution possible des chaines de PEG greffées à l’extrémité de la chaine de PLA. Cette librairie de PEG-g-PLA, en plus d’être composée de PEG-g-PLA avec différentes densités de greffage, comporte des PEG-g-PLA avec des PEG de différent poids moléculaire (750, 2000 et 5000). Les chaines de PEG sont seulement greffées sur les groupes pendants. Les NPs ont été produites par différentes méthodes de nanoprécipitation, incluant la nanoprécipitation « flash » et une méthode en microfluidique. Plusieurs variables de formulation telles que la concentration du polymère et la vitesse de mélange ont été étudiées afin d’observer leur effet sur les caractéristiques structurales et de surface des NPs. Les tailles et les potentiels de charges sont peu affectés par le contenu en PEG (% poids/poids) et la longueur des chaînes de PEG. Les images de MET montrent des objets sphériques solides et l'on n’observe pas d’objets de type agrégat polymériques, malgré des contenus en PEG comparable à la première bibliothèque de polymère. Une explication possible est l’absence sur ces copolymères en peigne de chaine de PEG greffée en bout de la chaîne principale. Comme attendu, les tailles diminuent avec la concentration du polymère dans la phase organique et avec la diminution du temps de mélange des deux phases, pour les différentes méthodes de préparation. Finalement, la densité de surface des chaînes de PEG a été quantifiée par RMN du proton et XPS et ne dépendent pas de la méthode de préparation. Dans la troisième partie de ce travail, nous avons étudié le rôle de l’architecture du polymère sur les propriétés d’encapsulation et de libération de la curcumine. La curcumine a été choisie comme modèle dans le but de développer une plateforme de livraison de molécules actives pour traiter les maladies du système nerveux central impliquant le stress oxydatif. Les NPs chargées en curcumine, montrent la même transition de taille et de morphologie lorsque le contenu en PEG dépasse 15% (poids/poids). Le taux de chargement en molécule active, l’efficacité de changement et les cinétiques de libérations ainsi que les coefficients de diffusion de la curcumine montrent une dépendance à l’architecture des polymères. Les NPs ne présentent pas de toxicité et n’induisent pas de stress oxydatif lorsque testés in vitro sur une lignée cellulaire neuronale. En revanche, les NPs chargées en curcumine préviennent le stress oxydatif induit dans ces cellules neuronales. La magnitude de cet effet est reliée à l’architecture du polymère et à l’organisation de la NP. En résumé, ce travail a permis de mettre en évidence quelques propriétés intéressantes des copolymères en peigne et la relation intime entre l’architecture des polymères et les propriétés physico-chimiques des NPs. De plus les résultats obtenus permettent de proposer de nouvelles approches pour le design des nanotransporteurs polymériques de molécules actives.