975 resultados para Period wave characteristics
Resumo:
Objective: To present the clinical features and management outcome in a large series of patients with periocular and orbital amyloidosis. Design: Retrospective, noncomparative, interventional case series. Patients: All patients diagnosed with periocular and orbital amyloidosis in 6 oculoplastic and orbital units. Methods: Clinical records of all patients were reviewed. Main Outcome Measures: Clinical presentation, radiological and histological findings, treatment modalities, and outcome. Results. The study included 24 patients (15 female, 9 male) with a mean age of 57 17 years. Nineteen cases were unilateral, and 5 were bilateral. Clinical signs and symptoms included a visible or palpable periocular mass or tissue infiltration (95.8%), ptosis (54.2%), periocular discomfort or pain (25%), proptosis or globe displacement (21%), limitations in ocular motility (16.7%), recurrent periocular subcutaneous hemorrhages (12.5%), and diplopia (8.3%). Seven cases had orbital involvement, and 17 were periocular. Immunohistochemistry in 7 patients showed B cells or plasma cells producing monoclonal immunoglobulin chains that were deposited as amyloid light chains. Only 1 patient was diagnosed with systemic amyloid light chain amyloidosis. Treatment modalities were mainly observation and surgical debulking. During a mean follow-up period of 39 months, 21% showed significant progression after treatment, whereas 79% were stable or showed no recurrence after treatment. Conclusion: Periocular and orbital amyloidosis may present with a wide spectrum of clinical findings and result in significant ocular morbidity. Complete surgical excision is not feasible in many cases, and the goal of treatment is to preserve function and to prevent sight-threatening complications.
Resumo:
Studies have shown that an increase in arterial stiffening can indicate the presence of cardiovascular diseases like hypertension. Current gold standard in clinical practice is by measuring the blood pressure of patients using a mercury sphygmomanometer. However, the nature of this technique is not suitable for prolonged monitoring. It has been established that pulse wave velocity is a direct measure of arterial stiffening. However, its usefulness is hampered by the absence of techniques to estimate it non-invasively. Pulse transit time (PTT) is a simple and non-intrusive method derived from pulse wave velocity. It has shown its capability in childhood respiratory sleep studies. Recently, regression equations that can predict PTT values for healthy Caucasian children were formulated. However, its usefulness to identify hypertensive children based on mean PTT values has not been investigated. This was a continual study where 3 more Caucasian male children with known clinical hypertension were recruited. Results indicated that the PTT predictive equations are able to identify hypertensive children from their normal counterparts in a significant manner (p < 0.05). Hence, PTT can be a useful diagnostic tool in identifying hypertension in children and shows potential to be a non-invasive continual monitor for arterial stiffening.
Resumo:
The curvature- or bend-sensing response of long-period gratings (LPGs) UV inscribed in D-shaped fiber has been investigated experimentally. Strong fiber-orientation dependence of the spectral response when such LPGs are subjected to bending at different directions has been observed and is shown to form the basis for a new class of single-device sensor with vector-sensing capability. Potential applications utilizing the linear response and unique bend-orientation characteristics of the devices are discussed.
Resumo:
A long period grating has been fabricated in endlessly single-mode photonic crystal fibre using a spatially-periodic electric arc discharge. The sensing characteristics of the grating have been studied and it was found to possess an insensitivity to temperature, a bend sensitivity of 3.7 nm · m and a strain sensitivity of -2.0 pm/µe.
Resumo:
The fabrication and characterization of long-period gratings (LPGs) in fiber tapers is presented alongside supporting theory. The devices possess a high sensitivity to the index of aqueous solutions due to an observed spectral bifurcation effect, yielding a limiting index resolution of ±8.5×10-5 for solutions with an index in the range 1.330-1.335.
Resumo:
This thesis presents the fabrication of fibre gratings in novel optical fibres for sensing applications. Long period gratings have been inscribed into photonic crystal fibre using the electric-arc technique. The resulting sensing characteristics were found to depend on the air-hole geometry of the particular fibre. This provides the potential of designing a fibre to have enhanced sensitivity to a particular measure and whilst removing unwanted cross sensitivities. Fibre Bragg gratings have been fabricated in a variety of polymer optical fibres, including microstructured polymer optical fibre, using a continuous wave helium cadmium laser. The thermal response of the gratings have been characterised and found to have enhanced sensitivity compared to fibre Bragg gratings in silica optical fibre. The increased sensitivity has been harnessed to achieve a grating based device in single mode step index polymer optical fibre by fabricating an electrically tunable fibre Bragg grating. This was accomplished by coating the grating region in a thin layer of copper, which upon application of a direct current, causes a temperature induced Bragg wavelength shift.
Resumo:
A long period grating was photoinscribed step-by-step in microstructured poly(methyl methacrylate) fiber for the first time using a continuous wave HeCd laser at 325 nm, irradiating the fiber with a power of 1 mW. The grating had a length of 2 cm and a period of 1 mm. A series of cladding mode coupling resonances were observed throughout the spectral region studied of 600 to 1100 nm. The resonance wavelengths were shown to be sensitive to the diffusion of water into the fiber.
Resumo:
We investigate experimentally the fundamental characteristics of space-charge waves excited in a photorefractive crystal of Bi12SiO20. Features such as their transient rise and decay as well as their steady-state frequency response are investigated. Based on this, we find the dependence of the space-charge waves' quality factor on spatial frequency and electric-field biasing. The experimental findings are compared with the linear space-charge wave theory developed previously by Sturman et al. [J. Opt. Sec. Am. B 10, 1919 (1993)].
Resumo:
There has been a persistent increase in the number of meticillin-resistant Staphylococcus aureus (MRSA) and meticillin-susceptible Staphylococcus aureus (MSSA) bacteraemia in the UK. This prospective study included 147 episodes of S. aureus bacteraemia in 139 patients over a 14 month period, from 1 November 2001 to 31 December 2002. Eighty-seven (59%) episodes in 84 patients and 60 (41%) in 56 patients were due to MRSA and MSSA, respectively. An intra-vascular device (29, 33%) and a soft-tissue (15, 25%) source were the commonest identifiable foci for bacteraemia in the MRSA and MSSA groups, respectively. Attributable mortality in the MRSA group was higher than the MSSA group (33% vs 16%; P = 0.03) but there was no statistical difference for either attributable (P = 0.35) or crude (P = 0.39) mortality between the two groups, when adjusted for age, respiratory focus and inappropriate antibiotic therapy. A respiratory source (P = 0.02) and inappropriate antibiotic therapy (P = 0.02) were associated with attributable mortality in the MRSA group whereas advanced age was the only risk factor (P = 0.02) in the MSSA group. The present study shows that S. aureus bacteraemia continues to be a serious infection mostly affecting the elderly and emphasizes the need for improved strategy in the control and management of this condition. © 2006 The Hospital Infection Society.
Resumo:
It is shown that regimes with dynamical chaos are inherent not only to nonlinear system but they can be generated by initially linear systems and the requirements for chaotic dynamics and characteristics need further elaboration. Three simplest physical models are considered as examples. In the first, dynamic chaos in the interaction of three linear oscillators is investigated. Analogous process is shown in the second model of electromagnetic wave scattering in a double periodical inhomogeneous medium occupying half-space. The third model is a linear parametric problem for the electromagnetic field in homogeneous dielectric medium which permittivity is modulated in time. © 2008 Springer Science+Business Media, LLC.
Resumo:
Speech comprises dynamic and heterogeneous acoustic elements, yet it is heard as a single perceptual stream even when accompanied by other sounds. The relative contributions of grouping “primitives” and of speech-specific grouping factors to the perceptual coherence of speech are unclear, and the acoustical correlates of the latter remain unspecified. The parametric manipulations possible with simplified speech signals, such as sine-wave analogues, make them attractive stimuli to explore these issues. Given that the factors governing perceptual organization are generally revealed only where competition operates, the second-formant competitor (F2C) paradigm was used, in which the listener must resist competition to optimize recognition [Remez et al., Psychol. Rev. 101, 129-156 (1994)]. Three-formant (F1+F2+F3) sine-wave analogues were derived from natural sentences and presented dichotically (one ear = F1+F2C+F3; opposite ear = F2). Different versions of F2C were derived from F2 using separate manipulations of its amplitude and frequency contours. F2Cs with time-varying frequency contours were highly effective competitors, regardless of their amplitude characteristics. In contrast, F2Cs with constant frequency contours were completely ineffective. Competitor efficacy was not due to energetic masking of F3 by F2C. These findings indicate that modulation of the frequency, but not the amplitude, contour is critical for across-formant grouping.
Resumo:
We investigate experimentally the fundamental characteristics of space-charge waves excited in a photorefractive crystal of Bi12SiO20. Features such as their transient rise and decay as well as their steady-state frequency response are investigated. Based on this, we find the dependence of the space-charge waves' quality factor on spatial frequency and electric-field biasing. The experimental findings are compared with the linear space-charge wave theory developed previously by Sturman et al. [J. Opt. Sec. Am. B 10, 1919 (1993)].
Resumo:
There were three principle aims to this thesis. Firstly, the acquisition protocols of clinical blood flow apparatus were investigated in order to optimise them for both cross-sectional and longitudinal application. Secondly, the effects of physiological factors including age and systematic circulation on ocular blood flow were investigated. Finally, the ocular perfusion characteristics of patients diagnosed with ocular diseases considered to be of a vascular origin were investigated. The principle findings of this work are:- 1) Optimisation of clinical investigationsPhotodiode sensitivity of the scanning laser Doppler flowmeter should be kept within a range of 70-150 DC when acquiring images of the retina and optic nerve head in order to optimise the reproducibility of capillary blood flow measures. Account of the physiological spatial variation in retinal blood flow measures can be made using standard analysis protocols of the scanning laser Doppler flowmeter combined with a local search strategy. Measurements of pulsatile ocular blood flow using the ocular blood flow analyser are reproducible, however this reproducibility can be improved when consecutive intraocular pressure pulses are used to calculate pulsatile ocular blood flow. Spectral analysis of the intraocular pressure pulse-wave is viable and identifies the first four harmonic components of the waveform. 2) Physiological variation in ocular perfusionAge results in a significant reduction in perfusion of the retinal microcirculation, which is not evident in larger vessel beds such as the choroid. Despite known asymmetry in the systemic vasculature, no evidence of interocular asymmetry in ocular perfusion is apparent. 3) Pathological variation in ocular perfusionIn primary open angle glaucoma, perfusion is reduced in the retinal microcirculation of patients classified as having early to moderate visual field defects. However, ocular pulsatility defects are masked when patients and subjects are matched for systemic variables (pulse rate and mean arterial pressure); differentiation is facilitated by the application of waveform analysis to the continuos intraocular pressure curve even in the early stages of disease. Diabetic patients with adequate glycaemic control, exhibit maintenance of macular blood flow, macular topography and visual function following phacoemulsification.
Resumo:
Point-by-point inscription of sub-µm period fiber Bragg gratings with good spectral quality, first order Bragg resonances within the C-band is achieved. Distinct polarization characteristics are further observed in these fiber gratings.
Resumo:
The use of high intensity femtosecond laser sources for inscribing fibre gratings has attained significant interest. The principal advantage of high-energy pulses is their ability for grating inscription in any material type without preprocessing or special core doping - the inscription process is controlled multi-photon absorption, void generation and subsequent local refractive index changes. The formation of grating structures in photonics crystal fibre has proven difficult, as the presence of holes within the fibre that allow wave-guidance impair and scatter the femtosecond inscription beam. Here we report on the consistent manufacture of long period gratings in endlessly single mode microstructure fibre and on their characterisation to external perturbations. Long period gratings are currently the subject of considerable research interest due to their potential applications as filters and as sensing devices, responsive to strain, temperature, bending and refractive index. Compared to the more mature fibre Bragg grating sensors, LPGs have more complex spectra, usually with broader spectral features. On the other hand they are intrinsically sensitive to bending and refractive index. Perhaps more importantly, the fibre design and choice of grating period can have a considerable influence over the sensitivity to the various parameters, for example allowing the creation of a bend sensor with minimal temperature cross-sensitivity. This control is not possible with FBG sensors. Here we compare the effects of symmetric and asymmetric femtosecond laser inscription.