896 resultados para Oscillator strength
Resumo:
Coherent coupling between a large number of qubits is the goal for scalable approaches to solid state quantum information processing. Prototype systems can be characterized by spectroscopic techniques. Here, we use pulsed-continuous wave microwave spectroscopy to study the behavior of electrons trapped at defects within the gate dielectric of a sol-gel-based high-k silicon MOSFET. Disorder leads to a wide distribution in trap properties, allowing more than 1000 traps to be individually addressed in a single transistor within the accessible frequency domain. Their dynamical behavior is explored by pulsing the microwave excitation over a range of times comparable to the phase coherence time and the lifetime of the electron in the trap. Trap occupancy is limited to a single electron, which can be manipulated by resonant microwave excitation and the resulting change in trap occupancy is detected by the change in the channel current of the transistor. The trap behavior is described by a classical damped driven simple harmonic oscillator model, with the phase coherence, lifetime and coupling strength parameters derived from a continuous wave (CW) measurement only. For pulse times shorter than the phase coherence time, the energy exchange between traps, due to the coupling, strongly modulates the observed drain current change. This effect could be exploited for 2-qubit gate operation. The very large number of resonances observed in this system would allow a complex multi-qubit quantum mechanical circuit to be realized by this mechanism using only a single transistor.
Resumo:
The chorioamnion is the membrane that surrounds the fetus during gestation. Normally, it must remain intact for the duration of pregnancy, 37-42 weeks, and only rupture during or just before labour and delivery of the fetus. In a significant number (3%) of all births, this does not happen, and membranes rupture before term, resulting in preterm birth and significant perinatal morbidity. It is known that the material properties of chorioamnion may play a major role in mechanical rupture; a number of studies have been undertaken to characterise the physical nature of chorioamnion and examine factors that may predispose to rupture. However, the existing literature is inconsistent in its choice of both physical testing methods and data analysis techniques, motivating the current review. Experimental data from a large number of chorioamnion mechanical studies were collated, and data were converted to standard engineering quantities. The failure strength of the chorioamnion membrane was found consistently to value approximately 0.9 MPa. It is hoped that past and future studies of membrane mechanics can provide insight into the role of chorioamnion in labour and delivery. In addition, biomechanical approaches can help elucidate the potential causes of early rupture, and suggest future protocols or treatments that could both diagnose and prevent its occurrence. © 2009 Elsevier Ireland Ltd.
Resumo:
Influence of moisture and specific gravity on the strength of mango wood is discussed. The co-efficient of correlation between specific gravity and breaking strength was found to be non-significant. The relation of strength and moisture was found to be highly significant. The mean strength values indicated a reduction in strength when the moisture increased from 8.5 to 18.8%. However no appreciable difference in strength values could be observed when moisture increased above 37%. The strength-moisture relationship is a straight line, passing approximately through the fibre saturation point. By using the exponential formula, the breaking strength corresponding to any moisture level between zero and fibre saturation can be determined.
Resumo:
Photodegradation of three types of polyethylene twines namely, polyethylene fibrillated tape twine, polyethylene flat tape twine and polyethylene monofilament twines were studied by exposing them to sunlight and artificial UV radiation. The percentage residual strength varied in the samples, the monofilament with the highest residual strength followed by fibrillated tape twine and flat tape twine. A plot of the difference between the breaking strengths of the fibrillated tape twine and the mono filament twines against any given period of exposure exhibited a linear relationship
Resumo:
Synonymous codon bias has been examined in 78 human genes (19967 codons) and measured by relative synonymous codon usage (RSCU). Relative frequencies of all kinds of dinucleotides in 2,3 or 3,4 codon positions have been calculated, and codon-anticodon bin
Resumo:
We mode-lock a fiber oscillator with cavity length of ~1500m using nanotubes, achieving 1.55ps pulses with pulse energy up to 63nJ at 134 KHz repetition rate. © 2010 Optical Society of America.
Resumo:
In this paper, phase noise analysis of a mechanical autonomous impact oscillator with a MEMS resonator is performed. Since the circuit considered belongs to the class of hybrid systems, methods based on the variational model for the evaluation of either phase noise or steady state solutions cannot be directly applied. As a matter of fact, the monodromy matrix is not defined at impact events in these systems. By introducing saltation matrices, this limit is overcome and the aforementioned methods are extended. In particular, the unified theory developed by Demir is used to analyze the phase noise after evaluating the asymptotically stable periodic solution of the system by resorting to the shooting method. Numerical results are presented to show how noise sources affect the phase noise performances. © 2011 IEEE.
Resumo:
A large database of 115 triaxial, direct simple shear, and cyclic tests on 19 clays and silts is presented and analysed to develop an empirical framework for the prediction of the mobilization of the undrained shear strength, cu, of natural clays tested from an initially isotropic state of stress. The strain at half the peak undrained strength (γM=2) is used to normalize the shear strain data between mobilized strengths of 0.2cu and 0.8cu. A power law with an exponent of 0.6 is found to describe all the normalized data within a strain factor of 1.75 when a representative sample provides a value for γM=2. Multi-linear regression analysis shows that γM=2 is a function of cu, plasticity index Ip, and initial mean effective stress p′0. Of the 97 stress-strain curves for which cu, Ip, and p′0 were available, the observed values of γM=2 fell within a factor of three of the regression; this additional uncertainty should be acknowledged if a designer wished to limit immediate foundation settlements on the basis of an undrained strength profile and the plasticity index of the clay. The influence of stress history is also discussed. The application of these stress-strain relations to serviceability design calculations is portrayed through a worked example. The implications for geotechnical decision-making and codes of practice are considered.
Resumo:
BACKGROUND: When fresh morselized graft is compacted, as in impaction bone-grafting for revision hip surgery, fat and marrow fluid is either exuded or trapped in the voids between particles. We hypothesized that the presence of incompressible fluid damps and resists compressive forces during impaction and prevents the graft particles from moving into a closer formation, thus reducing the graft strength. In addition, viscous fluid such as fat may act as an interparticle lubricant, thus reducing the interlocking of the particles. METHODS: We performed mechanical shear testing in the laboratory with use of fresh-frozen human femoral-head allografts that had been passed through different orthopaedic bone mills to produce graft of differing particle-size distributions (grading). RESULTS: After compaction of fresh graft, fat and marrow fluid continued to escape on application of normal loads. Washed graft, however, had little lubricating fluid and better contact between the particles, increasing the shear resistance. On mechanical testing, washed graft was significantly (p < 0.001) more resistant to shearing forces than fresh graft was. This feature was consistent for different bone mills that produced graft of different particle-size distributions and shear strengths. CONCLUSIONS: Removal of fat and marrow fluid from milled human allograft by washing the graft allows the production of stronger compacted graft that is more resistant to shear, which is the usual mode of failure. Further research into the optimum grading of particle sizes from bone mills is required.
Resumo:
Background: When fresh morselized graft is compacted, as in impaction bone-grafting for revision hip surgery, fat and marrow fluid is either exuded or trapped in the voids between particles. We hypothesized that the presence of incompressible fluid damps and resists compressive forces during impaction and prevents the graft particles from moving into a closer formation, thus reducing the graft strength. In addition, viscous fluid such as fat may act as an interparticle lubricant, thus reducing the interlocking of the particles. Methods: We performed mechanical shear testing in the laboratory with use of fresh-frozen human femoral-head allografts that had been passed through different orthopaedic bone mills to produce graft of differing particle-size distributions (grading). Results: After compaction of fresh graft, fat and marrow fluid continued to escape on application of normal loads. Washed graft, however, had little lubricating fluid and better contact between the particles, increasing the shear resistance. On mechanical testing, washed graft was significantly (p < 0.001) more resistant to shearing forces than fresh graft was. This feature was consistent for different bone mills that produced graft of different particle-size distributions and shear strengths. Conclusions: Removal of fat and marrow fluid from milled human allograft by washing the graft allows the production of stronger compacted graft that is more resistant to shear, which is the usual mode of failure. Further research into the optimum grading of particle sizes from bone mills is required. Clinical Relevance: Understanding the mechanical properties of milled human allograft is important when impaction grafting is used for mechanical support. A simple means of improving the mechanical strength of graft produced by currently available bone mills, including an intraoperative washing technique, is described.