975 resultados para Orthopedic implants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Primary and secondary stabilities of immediately loaded mandibular implants restored with fixed prostheses (FP) using rigid or semirigid splinting systems were clinically and radiographically evaluated. Methods: Fifteen edentulous patients were rehabilitated using hybrid FP; each had 5 implants placed between the mental foramens. Two groups were randomly divided: group 1-FP with the conventional rigid bar splinting the implants and group 2-semi-rigid cantilever extension system with titanium bars placed in the 2 distal abutment cylinders. Primary stability was evaluated using resonance frequency analysis after installation of the implant abutments. The measurements were made at 3 times: T0, at baseline; T1, 4 months after implant placement; and T2, 8 months after implant placement. Presence of mobility and inflammation in the implant surrounding regions were checked. Stability data were submitted to statistical analysis for comparison between groups (P, 0.05). Results: Implant survival rate for the implants was of 100% in both groups. No significant differences in the mean implant stability quotient values were found for both groups from baseline and after the 8-month follow-up. Conclusion: The immediate loading of the implants was satisfactory, and both splinting conditions (rigid and semi-rigid) can be successfully used for the restoration of edentulous mandibles. (Implant Dent 2012;21:486-490)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In recent years, the benefits associated with the use of cochlear implants (CIs), especially with regard to speech perception, have proven to surpass those produced by the use of hearing aids, making CIs a highly efficient resource for patients with severe/profound hearing loss. However, few studies so far have assessed the satisfaction of adult users of CIs. Objective: To analyze the relationship between the level of speech perception and degree of satisfaction of adult users of CI. Method: This was a prospective cross-sectional study conducted in the Audiological Research Center (CPA) of the Hospital of Craniofacial Anomalies, University of São Paulo (HRAC/USP), in Bauru, São Paulo, Brazil. A total of 12 users of CIs with pre-lingual or post-lingual hearing loss participated in this study. The following tools were used in the assessment: a questionnaire, "Satisfaction with Amplification in Daily Life" (SADL), culturally adapted to Brazilian Portuguese, as well as its relationship with the speech perception results; a speech perception test under quiet conditions; and the Hearing in Noise Test (HINT)Brazil under free field conditions. Results: The participants in the study were on the whole satisfied with their devices, and the degree of satisfaction correlated positively with the ability to perceive monosyllabic words under quiet conditions. The satisfaction did not correlate with the level of speech perception in noisy environments. Conclusion: Assessments of satisfaction may help professionals to predict what other factors, in addition to speech perception, may contribute to the satisfaction of CI users in order to reorganize the intervention process to improve the users' quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and another of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the original component of the same brand as the implant was positioned, interchangeability was considered valid. Data were compared with the Kruskal-Wallis test at 5% significance level. Some degree of misfit was observed in all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6-16.9 µm, with a 4.6 µm median; and the former from 0.3-12.9 µm, with a 3.4 µm median. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for SIN and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Open bite has fascinated Orthodontics due to the difficulties regarding its treatment and maintenance of results. This anomaly has distinct characteristics that, in addition to the complexity of multiple etiological factors, have aesthetic and functional consequences. Within this etiological context, several types of mechanics have been used in open bite treatment, such as palatal crib, orthopedic forces, occlusal adjustment, orthodontic camouflage with or without extraction, orthodontic intervention using mini-implants or mini-plates, and even orthognathic surgery. An accurate diagnosis and etiological determination are always the best guides to establish the objectives and the ideal treatment plan for such a malocclusion. This report describes two cases of open bite. At the end of the treatment, both patients had their canines and molars in Class I occlusion, normal overjet and overbite, and stability during the posttreatment period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To explore the biomechanical effects of the different implantation bone levels of Morse taper implants, employing a finite element analysis (FEA). METHODS: Dental implants (TitamaxCM) with 4x13 mm and 4x11 mm, and their respective abutments with 3.5 mm height, simulating a screwed premolar metal-ceramic crown, had their design performed using the software AnsysWorkbench 10.0. They were positioned in bone blocks, covered by 2.5 mm thickness of mucosa. The cortical bone was designed with 1.5 mm thickness and the trabecular bone completed the bone block. Four groups were formed: group 11CBL (11 mm implant length on cortical bone level), group 11TBL (11 mm implant length on trabecular bone level), group 13CBL (13mm implant length on cortical bone level) and group 13TBL (13 mm implant length on trabecular bone level). Oblique 200 N loads were applied. Von Mises equivalent stresses in cortical and trabecular bones were evaluated with the same design program. RESULTS: The results were shown qualitatively and quantitatively by standard scales for each type of bone. By the results obtained, it can be suggested that positioning the implant completely in trabecular bone brings harm with respect to the generated stresses. Its implantation in the cortical bone has advantages with respect to better anchoring and locking, reflecting a better dissipation of the stresses along the implant/bone interfaces. In addition, the search for anchoring the implant in its apical region in cortical bone is of great value to improve stabilization and consequently better stress distribution. CONCLUSIONS: The implant position slightly below the bone in relation to the bone crest brings advantages as the best long-term predictability with respect to the expected neck bone loss.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last decades the development of bone substitutes characterized by a superior biomimetism has become of particular interest, owing to the increasing economic and societal impact of the bone diseases. In the present work of research the development of bone substitutes characterized by improved biomimetism, has been faced in a chemical, structural and morphological perspective. From a chemical point of view, it has been developed the synthesis of hydroxyapatite powders, exhibiting multiple ionic substitutions in both cationic and anionic sites, so to simulate the chemical composition of the natural bone. Particular emphasis has been given to the effect of silicon on the chemical-physical and solubility properties of the obtained hydroxyapatites. From a structural point of view, it has been developed the synthesis of ceramic composite materials, based on hydroxyapatite and calcium silicates, employed both as a reinforcing phase, to raise the mechanical strength of the composite compared to hydroxyapatite, and as a bioactive phase, able to increase the bioactivity properties of the whole ceramic. Finally the unique morphological features of the bone were mimicked by taking inspiration by Nature, so that native wood structures were treated in chemical and thermal way to obtain hydroxyapatite porous materials characterized by the same morphology as the native wood. The results obtained in the present work were positive in all the three different areas of investigation, so to cover the three different aspects of biomimetism, chemical, structural and morphological. Anyway, only at the convergence of the three different fields it is possible to find out the best solutions to develop the ideal bone-like scaffold. Thus, the future activity should be devoted to solve the problems at the borderline between the different research lines, which hamper this convergence and in consequence, the achievement of a bone scaffold able to mimic the various aspects exhibited by the bone tissue

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Several adverse consequences are caused by mild perioperative hypothermia. Maintaining normothermia with patient warming systems, today mostly with forced air (FA), has thus become a standard procedure during anesthesia. Recently, a polymer-based resistive patient warming system was developed. We compared the efficacy of a widely distributed FA system with the resistive-polymer (RP) system in a prospective, randomized clinical study. METHODS: Eighty patients scheduled for orthopedic surgery were randomized to either FA warming (Bair Hugger warming blanket #522 and blower #750, Arizant, Eden Prairie, MN) or RP warming (Hot Dog Multi-Position Blanket and Hot Dog controller, Augustine Biomedical, Eden Prairie, MN). Core temperature, skin temperature (head, upper and lower arm, chest, abdomen, back, thigh, and calf), and room temperature (general and near the patient) were recorded continuously. RESULTS: After an initial decrease, core temperatures increased in both groups at comparable rates (FA: 0.33 degrees C/h +/- 0.34 degrees C/h; RP: 0.29 degrees C/h +/- 0.35 degrees C/h; P = 0.6). There was also no difference in the course of mean skin and mean body (core) temperature. FA warming increased the environment close to the patient (the workplace of anesthesiologists and surgeons) more than RP warming (24.4 degrees C +/- 5.2 degrees C for FA vs 22.6 degrees C +/- 1.9 degrees C for RP at 30 minutes; P(AUC) <0.01). CONCLUSION: RP warming performed as efficiently as FA warming in patients undergoing orthopedic surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the use of computer-assisted designed and manufactured (CAD/CAM) orbital wall and floor implants for late reconstruction of extensive orbital fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study evaluates 3-year success rates of titanium screw-type implants with a chemically modified sandblasted and acid-etched surface (mod SLA), which were functionally loaded after 3 weeks of healing. METHODS: A total of 56 implants, inserted in the posterior mandibles of 39 partially edentulous patients, underwent undisturbed healing for 3 weeks. At day 21, the implants were fully loaded with provisional crowns. Definitive metal ceramic restorations were fabricated after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 36 months after implant placement. The soft tissue and radiographic parameters for the mod SLA implants after 3 years in function were compared to a historic control group of implants with an SLA surface using an early loading protocol after 6 weeks. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and were left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants, including the "spinners," showed favorable clinical and radiographic findings at the 3-year follow-up examination. All 56 implants were considered successfully integrated, resulting in a 3-year survival and success rate of 100%. Dental implants with a mod SLA surface demonstrated statistically significant differences for probing depths and clinical attachment level values compared to the historic control group, with the mod SLA surface implants having overall lower probing depths and clinical attachment level scores. CONCLUSION: This prospective study using an early loading protocol demonstrates that titanium implants with the mod SLA surface can achieve and maintain successful tissue integration over a period of 3 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To assess the biological and technical complication rates of single crowns on vital teeth (SC-V), endodontically treated teeth without post and core (SC-E), with a cast post and core (SC-PC) and on implants (SC-I). Material and methods: From 392 patients with chronic periodontitis treated and documented by graduate students during the period from 1978 to 2002, 199 were reexamined during 2005 for this retrospective cohort study, and 64 of these patients were treated with SCs. Statistical analysis included Kaplan–Meier survival functions and event rates per 100 years of object-time. Poisson regression was used to compare the four groups of crowns with respect to the incidence rate ratio of failures, and failures and complications combined over 10 years and the entire observation period. Results: Forty-one (64%) female and 23 (36%) male patients participated in the reexamination. At the time of seating the crowns, the mean patient age was 46.8 (range 24–66.3) years. One hundred and sixty-eight single unit crowns were incorporated. Their mean follow-up time was 11.8 (range 0.8–26.4) years. During the time of observation, 22 biological and 11 technical complications occurred; 19 SC were lost. The chance for SC-V (56) to remain free of any failure or complication was 89.3% (95% confidence interval [CI] 76.1–95.4) after 10 years, 85.8% (95% CI 66–94.5) for SC-E (34), 75.9% for SC-PC (39), (95% CI 58.8–86.7) and 66.2% (95% CI 45.1–80.7) for SC-I (39). Over 10 years, 95% of SC-I remained free of failure and demonstrated a cumulative incidence of failure or complication of 34%. Compared with SC-E, SC-I were 3.5 times more likely to yield failures or complications and SC-PC failed 1.7 times more frequently than did SC-E. SC-V had the lowest rate of failures or complications over the 10 years. Conclusions: While SCs on vital teeth have the best prognosis, those on endodontically treated teeth have a slightly poorer prognosis over 10 years. Crowns on teeth with post and cores and implant-supported SCs displayed the highest incidence of failures and complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this two-center study was to evaluate screw-type titanium implants with a chemically modified, sandblasted and acid-etched surface when placed in the posterior maxilla or mandible, and loaded 21 days after placement. MATERIAL AND METHODS: All 56 patients met strict inclusion criteria and provided informed consent. Each patient displayed either a single-tooth gap, an extended edentulous space, or a distal extension situation in the posterior mandible or maxilla. Eighty-nine dental implants (SLActive, Institut Straumann AG, Basel, Switzerland) were inserted according to an established nonsubmerged protocol and underwent undisturbed healing for a period of 21 days. Where appropriate, the implants were loaded after 21 days of healing with provisional restorations in full occlusion. Definitive metal ceramic restorations were fabricated and positioned on each implant after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 24 months after implant placement. RESULTS: Of the 89 inserted implants, two (2.2%) implants failed to integrate and were removed during healing, and two (2.2%) additional implants required a prolonged healing time. A total of 85 (95.6%) implants were therefore loaded without incident after 21 days of healing. No additional implant was lost throughout the study period, whereas one implant was lost to follow-up and therefore left unaccounted for further analysis. The remaining 86 implants all exhibited favorable radiographic and clinical findings. Based on strict success criteria, these implants were considered successfully integrated 2 years after insertion, resulting in a 2-year success rate of 97.7%. CONCLUSION: The results of this prospective two-center study demonstrate that titanium implants with a modified SLA surface can predictably achieve successful tissue integration when loaded in full occlusion 21 days after placement. Integration could be maintained without incident for at least 2 years of follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

to compare the 10-year marginal bone loss rates around implants supporting single-unit crowns in tobacco smokers with and without a history of treated periodontitis.