974 resultados para Ocular prostheses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Video-oculography devices are now used to quantify the vestibulo-ocular reflex (VOR) at the bedside using the head impulse test (HIT). Little is known about the impact of disruptive phenomena (e.g. corrective saccades, nystagmus, fixation losses, eye-blink artifacts) on quantitative VOR assessment in acute vertigo. This study systematically characterized the frequency, nature, and impact of artifacts on HIT VOR measures. From a prospective study of 26 patients with acute vestibular syndrome (16 vestibular neuritis, 10 stroke), we classified findings using a structured coding manual. Of 1,358 individual HIT traces, 72% had abnormal disruptive saccades, 44% had at least one artifact, and 42% were uninterpretable. Physicians using quantitative recording devices to measure head impulse VOR responses for clinical diagnosis should be aware of the potential impact of disruptive eye movements and measurement artifacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Low levels of testosterone in men and changes in retinal microvascular calibre are both associated with hypertension and cardiovascular disease risk. Sex hormones are also associated with blood flow in microvascular beds which might be a key intermediate mechanism in the development of hypertension. Whether a direct association between endogenous testosterone and retinal microvascular calibre exists is currently unknown. We aimed to determine whether testosterone is independently associated with ocular perfusion via a possible association with retinal vascular calibre or whether it plays only a secondary role via its effect on blood pressure in a bi-ethnic male cohort. PROBANDS AND METHODS A total of 72 black and 81 white men (28-68 years of age) from the follow-up phase of the Sympathetic activity and Ambulatory Blood Pressure in Africans (SABPA) study were included in this sub-study. Ambulatory pulse pressure and intraocular perfusion pressures were obtained, while metabolic variables and testosterone were measured from fasting venous blood samples. Retinal vascular calibre was quantified from digital photographs using standardised protocols. RESULTS The black men revealed a poorer cardiometabolic profile and higher pulsatile pressure (>50 mm Hg), intraocular pressure and diastolic ocular perfusion pressure than the white men (p≤0.05). Only in the white men was free testosterone positively associated with retinal calibre, i.e. arterio-venular ratio and central retinal arterial calibre and inversely with central retinal venular calibre. These associations were not found in the black men, independent of whether pulse pressure and ocular perfusion pressure were part of the model. CONCLUSIONS These results suggest an independent, protective effect of testosterone on the retinal vasculature where an apparent vasodilatory response in the retinal resistance microvessels was observed in white men.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to directly compare metal artifact reduction (MAR) of virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (CT) with iterative MAR (iMAR) from single energy in pelvic CT with hip prostheses. MATERIALS AND METHODS A human pelvis phantom with unilateral or bilateral metal inserts of different material (steel and titanium) was scanned with third-generation dual-source CT using single (120 kVp) and dual-energy (100/150 kVp) at similar radiation dose (CT dose index, 7.15 mGy). Three image series for each phantom configuration were reconstructed: uncorrected, VME, and iMAR. Two independent, blinded radiologists assessed image quality quantitatively (noise and attenuation) and subjectively (5-point Likert scale). Intraclass correlation coefficients (ICCs) and Cohen κ were calculated to evaluate interreader agreements. Repeated measures analysis of variance and Friedman test were used to compare quantitative and qualitative image quality. Post hoc testing was performed using a corrected (Bonferroni) P < 0.017. RESULTS Agreements between readers were high for noise (all, ICC ≥ 0.975) and attenuation (all, ICC ≥ 0.986); agreements for qualitative assessment were good to perfect (all, κ ≥ 0.678). Compared with uncorrected images, VME showed significant noise reduction in the phantom with titanium only (P < 0.017), and iMAR showed significantly lower noise in all regions and phantom configurations (all, P < 0.017). In all phantom configurations, deviations of attenuation were smallest in images reconstructed with iMAR. For VME, there was a tendency toward higher subjective image quality in phantoms with titanium compared with uncorrected images, however, without reaching statistical significance (P > 0.017). Subjective image quality was rated significantly higher for images reconstructed with iMAR than for uncorrected images in all phantom configurations (all, P < 0.017). CONCLUSIONS Iterative MAR showed better MAR capabilities than VME in settings with bilateral hip prosthesis or unilateral steel prosthesis. In settings with unilateral hip prosthesis made of titanium, VME and iMAR performed similarly well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To identify the influence of fixed prosthesis type on biologic and technical complication rates in the context of screw versus cement retention. Furthermore, a multivariate analysis was conducted to determine which factors, when considered together, influence the complication and failure rates of fixed implant-supported prostheses. MATERIALS AND METHODS Electronic searches of MEDLINE (PubMed), EMBASE, and the Cochrane Library were conducted. Selected inclusion and exclusion criteria were used to limit the search. Data were analyzed statistically with simple and multivariate random-effects Poisson regressions. RESULTS Seventy-three articles qualified for inclusion in the study. Screw-retained prostheses showed a tendency toward and significantly more technical complications than cemented prostheses with single crowns and fixed partial prostheses, respectively. Resin chipping and ceramic veneer chipping had high mean event rates, at 10.04 and 8.95 per 100 years, respectively, for full-arch screwed prostheses. For "all fixed prostheses" (prosthesis type not reported or not known), significantly fewer biologic and technical complications were seen with screw retention. Multivariate analysis revealed a significantly greater incidence of technical complications with cemented prostheses. Full-arch prostheses, cantilevered prostheses, and "all fixed prostheses" had significantly higher complication rates than single crowns. A significantly greater incidence of technical and biologic complications was seen with cemented prostheses. CONCLUSION Screw-retained fixed partial prostheses demonstrated a significantly higher rate of technical complications and screw-retained full-arch prostheses demonstrated a notably high rate of veneer chipping. When "all fixed prostheses" were considered, significantly higher rates of technical and biologic complications were seen for cement-retained prostheses. Multivariate Poisson regression analysis failed to show a significant difference between screw- and cement-retained prostheses with respect to the incidence of failure but demonstrated a higher rate of technical and biologic complications for cement-retained prostheses. The incidence of technical complications was more dependent upon prosthesis and retention type than prosthesis or abutment material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Little information is yet available on zirconia-based prostheses supported by implants. PURPOSE To evaluate technical problems and failures of implant-supported zirconia-based prostheses with exclusive screw-retention. MATERIAL AND METHODS Consecutive patients received screw-retained zirconia-based prostheses supported by implants and were followed over a time period of 5 years. The implant placement and prosthetic rehabilitation were performed in one clinical setting, and all patients participated in the maintenance program. The treatment comprised single crowns (SCs) and fixed dental prostheses (FDPs) of three to 12 units. Screw-retention of the CAD/CAM-fabricated SCs and FDPs was performed with direct connection at the implant level. The primary outcome was the complete failure of zirconia-based prostheses; outcome measures were fracture of the framework or extensive chipping resulting in the need for refabrication. A life table analysis was performed, the cumulative survival rate (CSR) calculated, and a Kaplan-Meier curve drawn. RESULTS Two hundred and ninety-four implants supported 156 zirconia-based prostheses in 95 patients (52 men, 43 women, average age 59.1 ± 11.7 years). Sixty-five SCs and 91 FDPs were identified, comprising a total of 441 units. Fractures of the zirconia framework and extensive chipping resulted in refabrication of nine prostheses. Nearly all the prostheses (94.2%) remained in situ during the observation period. The 5-year CSR was 90.5%, and 41 prostheses (14 SCs, 27 FDPs) comprising 113 units survived for an observation time of more than 5 years. Six SCs exhibited screw loosening, and polishing of minor chipping was required for five prostheses. CONCLUSIONS This study shows that zirconia-based implant-supported fixed prostheses exhibit satisfactory treatment outcomes and that screw-retention directly at the implant level is feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, ocular vestibular evoked myogenic potentials (oVEMP) have emerged as a tool for assessment of utricular function. They are short-latency myogenic potentials which can be elicited in response to vestibular stimulation, e.g. by air-conducted sound (ACS) or bone-conducted vibration (BCV) (reviewed in (Kantner and Gurkov, 2012)). Otolithic afferent neurons trigger reflexive electromyographic activity of the extraocular muscles which can be recorded beneath the eye contralateral to the stimulated ear by use of surface electrodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Ocular vestibular-evoked myogenic potentials (oVEMPs) represent extraocular muscle activity in response to vestibular stimulation. The authors sought to investigate whether posture-induced increase of the intracranial pressure (ICP) modulated oVEMP frequency tuning, that is, the amplitude ratio between 500-Hz and 1000-Hz stimuli. DESIGN Ten healthy subjects were enrolled in this study. The subjects were positioned in the horizontal plane (0 degree) and in a 30-degree head-downwards position to elevate the ICP. In both positions, oVEMPs were recorded using 500-Hz and 1000-Hz air-conducted tone bursts. RESULTS When tilting the subject from the horizontal plane to the 30-degree head-down position, oVEMP amplitudes in response to 500-Hz tone bursts distinctly decreased (3.40 μV versus 2.06 μV; p < 0.001), whereas amplitudes to 1000 Hz were only slightly diminished (2.74 μV versus 2.48 μV; p = 0.251). Correspondingly, the 500/1000-Hz amplitude ratio significantly decreased when tilting the subjects from 0- to 30-degree inclination (1.59 versus 1.05; p = 0.029). Latencies were not modulated by head-down position. CONCLUSIONS Increasing ICP systematically alters oVEMPs in terms of absolute amplitudes and frequency tuning characteristics. oVEMPs are therefore in principle suited for noninvasive ICP monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several congenital syndromes associated with anterior segment (AS) anomalies can lead to impaired vision and glaucoma, such as nail-patella syndrome (NPS), caused by mutations in the LIM homeodomain transcription factor LMX1B and Axenfeld-Rieger's syndrome (ARS), caused by mutations in the bicoid-related homeodomain transcription factor PITX2. Targeted mutations in lmx1b and pitx2 and RNA in situ analysis reveal that both genes are required for AS development and are co-expressed within the periocular mesenchyme, suggesting they participate in a shared genetic pathway. Lmx1b homozygous mutants display iris and corneal stroma hypoplasia, and defects in ciliary body formation. In contrast, pitx2 homozygous mutants exhibit a more severe phenotype: the AS chamber, corneal endothelium, and extraocular muscles (EOM) fail to develop. The absence of EOM in pitx2 mutants suggests pitx2 acts upstream of lmx1b, or that other lmx1b family members, such as lmx1a, can compensate for lmx1b function. Lmxla/lmx1b double homozygous mutants have a reduced capacity to generate EOM, implying that lmx1 gene products have a redundant function in EOM development and that lmx1 family members may act downstream of pitx2. However, analysis of pitx2 expression in the AS tissues of lmx1b mutants and reciprocal studies of lmx1b expression in pitx2 mutants indicate that these genes do not function in a simple linear pathway. Instead, lmx1b and pitx2 may regulate a shared set of downstream targets or both genes may work in parallel transcribing unique targets required for a common biological process. Ultrastructural analysis of lmx1b and pitx2 mutant corneas indicates that collagen fibrillogenesis is perturbed, revealing a common role for both genes in the deposition of extracellular matrix. Furthermore, lmx1b/pitx2 double heterozygotes develop corneal opacities not observed in single heterozygotes demonstrating that lmx1b and pitx2 genetically interact. Data suggests that defects in the basement membrane of the corneal endothelium underlie the opacities observed in double heterozygotes. Additionally, double heterozygotes develop anterior synechias that occlude the trabecular meshwork, potentially blocking aqueous humor drainage. These data suggest that lmx1b and pitx2 are responsible for ECM deposition in multiple cell types and imply that such defects may contribute to the glaucomas observed in NPS and ARS patients. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uveal melanoma is a rare but life-threatening form of ocular cancer. Contemporary treatment techniques include proton therapy, which enables conservation of the eye and its useful vision. Dose to the proximal structures is widely believed to play a role in treatment side effects, therefore, reliable dose estimates are required for properly evaluating the therapeutic value and complication risk of treatment plans. Unfortunately, current simplistic dose calculation algorithms can result in errors of up to 30% in the proximal region. In addition, they lack predictive methods for absolute dose per monitor unit (D/MU) values. ^ To facilitate more accurate dose predictions, a Monte Carlo model of an ocular proton nozzle was created and benchmarked against measured dose profiles to within ±3% or ±0.5 mm and D/MU values to within ±3%. The benchmarked Monte Carlo model was used to develop and validate a new broad beam dose algorithm that included the influence of edgescattered protons on the cross-field intensity profile, the effect of energy straggling in the distal portion of poly-energetic beams, and the proton fluence loss as a function of residual range. Generally, the analytical algorithm predicted relative dose distributions that were within ±3% or ±0.5 mm and absolute D/MU values that were within ±3% of Monte Carlo calculations. Slightly larger dose differences were observed at depths less than 7 mm, an effect attributed to the dose contributions of edge-scattered protons. Additional comparisons of Monte Carlo and broad beam dose predictions were made in a detailed eye model developed in this work, with generally similar findings. ^ Monte Carlo was shown to be an excellent predictor of the measured dose profiles and D/MU values and a valuable tool for developing and validating a broad beam dose algorithm for ocular proton therapy. The more detailed physics modeling by the Monte Carlo and broad beam dose algorithms represent an improvement in the accuracy of relative dose predictions over current techniques, and they provide absolute dose predictions. It is anticipated these improvements can be used to develop treatment strategies that reduce the incidence or severity of treatment complications by sparing normal tissue. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dynamic characteristics of reflex eye movements were measured in two strains of chronically prepared mice by using an infrared television camera system. The horizontal vestibulo-ocular reflex (HVOR) and horizontal optokinetic response (HOKR) were induced by sinusoidal oscillations of a turntable, in darkness, by 10° (peak to peak) at 0.11–0.50 Hz and of a checked-pattern screen, in light, by 5–20°at 0.11–0.17 Hz, respectively. The gains and phases of the HVOR and HOKR of the C57BL/6 mice were nearly equivalent to those of rabbits and rats, whereas the 129/Sv mice exhibited very low gains in the HVOR and moderate phase lags in the HOKR, suggesting an inherent sensory-motor anomaly. Adaptability of the HOKR was examined in C57BL/6 mice by sustained screen oscillation. When the screen was oscillated by 10° at 0.17 Hz, which induced sufficient retinal slips, the gain of the HOKR increased by 0.08 in 1 h on average, whereas the stimuli that induced relatively small or no retinal slips affected the gain very little. Lesions of the flocculi induced by local applications of 0.1% ibotenic acid and lesions of the inferior olivary nuclei induced by i.p. injection of 3-acetylpyridine in C57BL/6 mice little affected the dynamic characteristics of the HVOR and HOKR, but abolished the adaptation of the HOKR. These results indicate that the olivo-floccular system plays an essential role in the adaptive control of the ocular reflex in mice, as suggested in other animal species. The data presented provide the basis for analyzing the reflex eye movements of genetically engineered mice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purines can modify ciliary epithelial secretion of aqueous humor into the eye. The source of the purinergic agonists acting in the ciliary epithelium, as in many epithelial tissues, is unknown. We found that the fluorescent ATP marker quinacrine stained rabbit and bovine ciliary epithelia but not the nerve fibers in the ciliary bodies. Cultured bovine pigmented and nonpigmented ciliary epithelial cells also stained intensely when incubated with quinacrine. Hypotonic stimulation of cultured epithelial cells increased the extracellular ATP concentration by 3-fold; this measurement underestimates actual release as the cells also displayed ecto-ATPase activity. The hypotonically triggered increase in ATP was inhibited by the Cl−-channel blocker 5-nitro-2-(3-phenylpropylamino)benzoic acid (NPPB) in both cell types. In contrast, the P-glycoprotein inhibitors tamoxifen and verapamil and the cystic fibrosis transmembrane conductance regulator (CFTR) blockers glybenclamide and diphenylamine-2-carboxylate did not affect ATP release from either cell type. This pharmacological profile suggests that ATP release is not restricted to P-glycoprotein or the cystic fibrosis transmembrane conductance regulator, but can proceed through a route sensitive to NPPB. ATP release also was triggered by ionomycin through a different NPPB-insensitive mechanism, inhibitable by the calcium/calmodulin-activated kinase II inhibitor KN-62. Thus, both layers of the ciliary epithelium store and release ATP, and purines likely modulate aqueous humor flow by paracrine and/or autocrine mechanisms within the two cell layers of this epithelium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent experimental evidence has shown that application of certain neurotrophic factors (NTs) to the developing primary visual cortex prevents the development of ocular dominance (OD) columns. One interpretation of this result is that afferents from the lateral geniculate nucleus compete for postsynaptic trophic factor in an activity-dependent manner. Application of excess trophic factor eliminates this competition, thereby preventing OD column formation. We present a model of OD column development, incorporating Hebbian synaptic modification and activity-driven competition for NT, which accounts for both normal OD column development as well as the prevention of that development when competition is removed. In the “control” situation, when available NT is below a critical amount, OD columns form normally. These columns form without weight normalization procedures and in the presence of positive inter-eye correlations. In the “experimental” case, OD column development is prevented in a local neighborhood in which excess NT has been added. Our model proposes a biologically plausible mechanism for competition between neural populations that is motivated by several pieces of experimental data, thereby accounting for both normal and experimentally perturbed conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ocular dominance column formation in visual cortex depends on both the presence of subplate neurons and the endogenous expression of neurotrophins. Here we show that deletion of subplate neurons, which supply glutamatergic inputs to visual cortex, leads to a paradoxical increase in brain-derived neurotrophic factor mRNA in the same region of visual cortex in which ocular dominance columns are absent. Subplate neuron ablation also increases glutamic acid decarboxylase-67 levels, indicating an alteration in cortical inhibition. These observations imply a role for this special class of neurons in modulating activity-dependent competition by regulating levels of neurotrophins and excitability within a developing cortical circuit.