877 resultados para New Marginal Literature


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mechanisms underpinning fatigue and exhaustion, and the specific sources of exercise-endurance intensity regulation and (in)tolerance have been investigated for over a century. Although several scientific theories are currently available, over the past five years a new framework called Psychobiological model has been proposed. This model gives greater attention to perceptual and motivational factors than its antecedents, and their respective influence on the conscious process of decision-making and behavioral regulation. In this review we present experimental evidences and summarize the key points of the Psychobiological model to explain intensity regulation and (in)tolerance in endurance exercise. Still, we discuss how the Psychobiological model explains training-induced adaptations related to improvements in performance, experimental manipulations, its predictions, and propose future directions for this investigative area. The Psychobiological model may give a new perspective to the results already published in the literature, helping scientists to better guide their research problems, as well as to analyze and interpret new findings more accurately.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A fração em acetato de etila (EtOAc) obtida a partir da partição do extrato de etanol (EtOH) das folhas de O. sessiliflora R. E. Fries (Annonaceae) foi submetida a diversos procedimentos cromatográficos, incluindo cromatografia líquida de alta eficiência (HPLC), o que resultou no isolamento dos flavonóides: quercetina-3-O-α-L-ramnopiranosil-(1→4)-β-D-glucopiranosídeo (1), inédito na literatura, canferol-3-O-α-L-ramnopiranosil-(1→4)-β-D-glucopiranosídeo (2), rutina (3) e canferol-3-O-rutinosídeo (4). As estruturas foram definidas através da análise dos espectros de ressonância magnética nuclear (NMR) de ¹H e de 13C (1D e 2D) e espectrometria de massas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Millions of people and animals suffer from superficial infections caused by a group of highly specialized filamentous fungi, the dermatophytes, which only infect keratinized structures. With the appearance of AIDS, the incidence of dermatophytosis has increased. Current drug therapy used for these infections is often toxic, long-term, and expensive and has limited effectiveness; therefore, the discovery of new anti dermatophytic compounds is a necessity. Natural products have been the most productive source for new drug development. This paper provides a brief review of the current literature regarding the presence of dermatophytes in immunocompromised patients, drug resistance to conventional treatments and new anti dermatophytic treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To determine the marginal adaptation of bulk-fill composites in class II MO cavities.Methods: Standardized class II MO cavities with bevelled enamel margins were prepared in 40 extracted human molars. The teeth were randomly assigned to one of the five experimental groups (n = 8). The teeth were restored with two horizontal increments of composite (4 mm and 2 mm thickness). The experimental groups were (1st/2nd increment): Gr. A - Venus Bulk-Fill/Venus Diamond; Gr. B - Tetric EvoCeram BulkFill/Tetric EvoCeram; Gr. C - Surefil SDR/Ceram-X; Gr. D - SonicFill; Gr. E - Ceram-X/Ceram-X (control). After finishing procedures, impressions were made using a polyvinyl siloxane and epoxy resin replicas were obtained. Thermo-mechanical stressing was carried out 24 h after the restorative procedure. All specimens were submitted to 240,000 occlusal loading and simultaneous 600 thermal cycles in water at 5 degrees C and 50 degrees C. After loading, a new set of epoxy resin replicas was obtained. Scanning electron microscopy was carried out at 200x magnification. Results for the marginal adaptation were expressed as percentages of continuity relative to the exposed interface and analyzed by ANOVA and Duncan post hoc test (p < 0.05).Results: In enamel, no significant differences were detected before and after thermo-mechanical loading between groups. In dentine, the worst results were observed in Gr. A.Conclusion: By applying simple layering techniques, bulk-fill materials do not allow better marginal adaptation than a standard composite. Clinical significance: A new class of resin-base composite (bulk-fill) was recently launched on the market. The bulk-fill composites exhibited adequate marginal adaptation and similar to the results of the standard composite. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The main function of the mucociliary system is the removal of particles or substances that are potentially harmful to the respiratory tract. The tuning fork therapeutic for the purpose of bronchial hygiene has still not been described in the literature. The optimal vibration frequency to mobilize secretions is widely debated and varies between 3 and 25 Hz. It is expected that a tuning fork is able to generate vibrations in the thorax, facilitating bronchial hygiene. The aim of the present study is to develop tuning forks with different frequencies, for use in bronchopulmonary hygiene therapy. Methods: The first tuning fork was made with a fixed frequency of 25 Hz and it was recorded in the Brazilian institution of patent registration. This device generated a frequency of 25 Hz and had a weight of 521 g, with dimensions of 600 mm in total length. The device is characterized by a bottom end containing a transducer with a diameter of 62 mm and a thickness of 5/16 mm (8''), a rod removable 148 mm, fork length of 362 mm and an extension at the upper end of sinuous shape bilaterally.The tuning forks must be applied at an angle of 90° directly on the chest wall of the patient after pulmonary auscultation for location of secretions. The tuning fork is activated by squeezing the tips of the extensions together and releasing them in a sudden movement. Results: This study shows the result of the development of others three tuning forks of different dimensions to generate different frequencies. Each equipment reaches a fixed frequency preset of 12, 15 and 20 Hz measured by digital oscilloscope. Conclusions: The tuning fork models developed in this study generated different frequencies proposed by the scientific literature as effective in the mobilization of pulmonary secretions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: We aimed to establish values and parameters using multislice reconstruction in axial computerized tomography (CT) in order to quantify the erosion of the glenoid cavity in cases of shoulder instability. Methods: We studied two groups using CT. Group I had normal subjects and Group II had patients with shoulder instability. We measured values of the vertical segment, the superior horizontal, medial and inferior segments, and also calculated the ratio of the horizontal superior and inferior segments of the glenoid cavity in both normal subjects and those with shoulder instability. These variables were recorded during arthroscopy for cases with shoulder instability. Results: The mean values were 40.87 mm, 17.86 mm, 26.50 mm, 22.86 mm and 0.79 for vertical segment, the superior horizontal, medial and inferior segments, and the ratio between horizontal superior and inferior segments of the glenoid cavity respectively, in normal subjects. For subjects with unstable shoulders the mean values were 37.33 mm, 20.83 mm, 23.07 mm and 0.91 respectively. Arthroscopic measurements yielded an inferior segment value of 24.48 mm with a loss of 2.39 mm (17.57%). The ratio between the superior and inferior segments of the glenoid cavity was 0.79. This value can be used as a normative value for evaluating degree of erosion of the anterior border of the glenoid cavity. However, values found using CT should not be used on a comparative basis with values found during arthroscopy. Conclusions: Computerized tomographic measurements of the glenoid cavity yielded reliable values consistent with those in the literature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Periodontitis is an infectious disease characterized by chronic inflammation of the periodontium, and it is mediated and modulated by the host immune system. In the presence of microorganisms or other antigens, immune cells (macrophages/monocytes, dendritic cells, lymphocytes, neutrophils), endothelial cells and fibroblasts secrete cytokines and trigger immune and inflammatory reactions. However, when synthesized at high levels, cytokines modify the pattern of cellular response, participating substantially in the development of chronic inflammatory pathologies, such as periodontal disease. Understanding the origin and progression of bone resorption is one of the primary goals of the field of periodontics, aiming to arrest the disease progression and to optimize future treatments. For this purpose, the development of experimental models is an important and necessary step before entering into clinical trials with new therapies. The purpose of this study is to characterize/evaluate the tissue changes induced by various models of experimental periodontitis through a literature review.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the areas of human identification is Cheiloscopy, the name given to the study of the lips, their characteristics (such as thickness, position of the grooves and grooves) and the record of the impressions left by them. There are variations in the layout of the lines and fissures of the lips, which are unique to each individual, permanent and unchanging. The lip print rarely changes, enduring minor traumas such as inflammation or sores. In criminal investigations, lip prints, visible through the presence of lipstick, can be found on glasses, napkins, clothes, cigarettes, indicating a relationship between the subject and the scene of the crime. Latent impressions may be revealed employing specific chemicals such as powder of silver and aluminum nitrate. Although it is not a very common method, Cheiloscopy may become very useful in forensics due to the extensive amount of valuable information that it brings. The objective of this study was to review the literature on the use of Cheiloscopy in human identification, using traditional and digital methods. It was found that the literature is still in need of studies in this area. The advent of new digital technologies can facilitate the implementation of technical expertise, generating speed and objectivity. New research studies are necessary, especially in the development of digital methods. The application of Cheiloscopy can greatlyhelp with Law, in the identification of living suspects and dead individuals. In the end the benefit will fall to society as a whole.