946 resultados para Median strips x Evaluation.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dental trauma, particularly tooth avulsion, is a frequent cause of tooth loss in children, adolescents, and young adults. The avulsed tooth should be immediately reimplanted in its alveolus. This procedure can be performed by anyone at the accident site and not only by dental surgeons. Therefore, the purpose of this study is to evaluate the knowledge of sixth graders of the city of Aracatuba, SP, about dental avulsion and tooth reimplantation through a structured and standardized survey. Our sample consisted of 778 students. The data collected was processed using the program epiinfo 2000. Most students were around 12 years of age and 94.5% related to practice some kind of sports. Results demonstrated that the possibility of tooth reimplantation after dental avulsion is not acknowledged among these students and dental traumatism was associated to caries, toothache, and use of orthodontic appliances. Only 18.9% of the students associated dental traumatism to an impact trauma; 3.6% would store the tooth in milk, and 3.1% believed the tooth could be reimplanted by anyone present at the accident site. In summary, the results show an overall the lack of knowledge about dental traumatism and highlight the need of special programs designed to educate school-aged students about emergency procedures to handle cases of dental traumatisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traumatic tooth injuries involve function and aesthetics and cause damage that range from minimal enamel loss to complex fractures involving the pulp tissue and even loss of the tooth crown. Technical knowledge and clinical experience are essential to establish an accurate diagnosis and provide a rational treatment. The purpose of this study was to evaluate the knowledge of Restorative Dentistry specialists about the management of crown and crown-root fractures based on treatment plans proposed by these professionals for these cases. A descriptive questionnaire was mailed to 245 Restorative Dentistry specialists with questions referring to their professional profile and the treatment plans they would propose for the management of crown and crow-root fractures resulting from dental trauma. One hundred and fifty-four questionnaires were returned properly filled. The data were subjected to descriptive statistics and the chi-square test was used to determine the frequency and the level of the significance among the variables. The analysis of data showed that in spite of having a specialist title, all interviewees had great difficulty in planning the treatments. As much as 42.8% of the participants were unable to treat all types of dental trauma. Complicated and uncomplicated crown-root fractures posed the greatest difficulties for the dentists to establish adequate treatment plans because these fractures require multidisciplinary knowledge and approach for a correct case planning and prognosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 x 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aims of this study were to analyze the histomorphology of developing permanent teeth whose primary teeth had suffered traumatic intrusion, as well as to compare the influence of immediate extraction of the intruded tooth to passive re-eruption. Nine dogs from 45 to 50 days old were submitted to the intrusion of the maxillary central and lateral primary incisors using a force applicator adapted to the teeth incisal cuspids. The right side intruded teeth were kept in their sockets and the ones on the left side were extracted 30 min later. After a postoperatory periods of 30 and 60 days, four (group 1) and five (group 2) dogs, respectively, were killed by perfusion. The histological evaluations showed that, in group 1, alterations had occurred in the odontoblastic layer and deposition of the enamel matrix had taken place in some specimens while in group 2, a portion of non-mineralized matrix was observed. We concluded that the morphological changes were because of the immediate trauma of intrusion. No differences were found between the groups where the primary tooth was immediately extracted or left to passively re-erupt.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The toothbrush is an effective instrument for oral diseases prevention. The flexibility and status of bristles, as well as the size of the handle are fundamental for an effective toothbrushing. Thus, the assessment of physical characteristics of toothbrushes is important. This study evaluated the deterioration and wear of bristles of toothbrushes used by preschool children. For the sample selection, five elementary schools were assorted from a city of the São Paulo State northwest region, one from each city area. All toothbrushes used by preschool children who aged between 5 and 6 years old and who attended the assorted schools were visually analysed by two calibrated examiners, according to the criteria proposed by Rawls HR, Mkwayi-Tulloch NJ, Casella R, Cosgrove R (J Dent Res 1989; 12: 1781): 0 - it is impossible to state if the toothbrush was used or not; 1 - the bristles seem to be separated within some tufts; 2 - most tufts are separated, many cover other tufts and present a large number of curved and inclined bristles; 3 - most tufts are covered by others and bristles are folded and tipped. In total, 333 toothbrushes were evaluated. The data obtained revealed that 57.96% of the toothbrushes presented adequate condition for utilization (scores 0 and 1), whereas 42.04% presented inadequate bristles for their function (scores 2 and 3). It was concluded that a great number of toothbrushes presented deterioration of the bristles. Thus, there is the need to guide and promote awareness among teachers, parents and children as well as the need to replace toothbrushes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this in vivo study was to evaluate the biocompatibility of three current bonding agents and calcium hydroxide cement. Sixty polyethylene tubes filled with the following materials: Group 1: Prime & Bond NT (PB - Dentsply, US; Group 2: Bond 1 (BO - Jeneric/Pentron, US); Group 3: Optibond Solo (OP - Kerr, US); and Group 4 (control): calcium hydroxide cement - Dycal (CH - Dentsply, US) were implanted into the connective tissue of 30 rats. After 15, 30 and 60 days, the implants were excised and the animals sacrificed. The biopsies were immersed in Karnovsky (pH, 7.2) fixative solution for 48 hours, and processed using routine histological technique. Six-micron-thick sections were cut and stained with hematoxilin and eosin and Masson's trichome technique. Microscopic evaluation was used to compare the connective tissue reactions caused by the experimental and control materials adjacent to the tube opening. At 15 days, the experimental and control materials triggered a moderate to intense inflammatory response which gave rise to a thick capsule adjacent to the tube opening. With time, the inflammatory reaction decreased. At 60 days, the connective tissue adjacent to the bonding agents exhibited a persistent inflammatory response mediated by macrophages and giant cells which were engulfing displaced resin components. on the other hand, for the control group (calcium hydroxide) no inflammatory response associated with a thin capsule adjacent to the material was observed even at the 30-day period. The hard-setting calcium hydroxide cement allowed complete healing and was considered more biocompatible than the bonding agents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intrusion is defined as the axial dislodgment of the tooth into its socket and is considered one of the most severe types of dental trauma. This longitudinal outcome study was undertaken to evaluate clinically and radiographically severely intruded permanent incisors in a population of children and adolescents. All cases were treated between September 2003 and February 2008 in a dental trauma service. Clinical and radiographic data were collected from 12 patients (eight males and four females) that represented 15 permanent maxillary incisors. Mean age at the time of injury was 8 years and 9 months (range 7-14 years and 8 months). Mean time elapsed to follow-up was 26.6 months (range 10-51 months). The analysis of data showed that tooth intrusion was twice as frequent in males. The maxillary central incisors were the most commonly intruded teeth (93.3%), and falling at home was the main etiologic factor (60%). More than half of the cases (53.3%) were multiple intrusions, 73.3% of the intruded teeth had incomplete root formation and 66.6% of the teeth suffered other injuries concomitant to intrusion. Immediate surgical repositioning was the treatment of choice in 66.7% of the cases, while watchful waiting for the tooth to return to its pre-injury position was adopted in 33.3% of the cases. The teeth that suffered additional injuries to the intrusive luxation presented a fivefold increased relative risk of developing pulp necrosis. The immature teeth had six times more chances of presenting pulp canal obliteration that the mature teeth and a lower risk of developing root resorption. The most frequent post-injury complications were pulp necrosis (73.3%), marginal bone loss (60%), inflammatory root resorption (40%), pulp canal obliteration (26.7%) and replacement root resorption (20%). From the results of this study, it was not possible to determine whether the type immediate treatment had any influence on the appearance of sequelae like pulp necrosis and root resorption after intrusive luxation, but the existence of additional injuries and the stage of root development influenced the clinical case outcome in a negative and positive manner, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Prosthetic rehabilitation of the posterior maxilla with dental implants is often difficult because of proximity to the maxillary sinus and insufficient bone height. Maxillary sinus floor augmentation procedures aim to obtain enough bone with an association between biomaterials and autogenous bone.Purpose: the purpose of this study was to evaluate histomorphometrically two grafting materials (calcium phosphate and Ricinus communis polymer) used in maxillary sinus floor augmentation associated with autogenous bone.Materials and Methods: Biopsies were taken from 10 consecutive subjects (mean age 45 years) 10 months after maxillary sinus floor augmentation. The sinus lift was performed with a mixture of autogenous bone and R. communis polymer or calcium phosphate in a 1:2 proportion. Routine histologic processing and staining with hernatoxylin and eosin were performed.Results: the histomorphometric analysis indicated satisfactory regenerative results in both groups for a mean of bone tissue in the grafted area (44.24 +/- 13.79% for the calcium phosphate group and 38.77 +/- 12.85% for the polymer group). Histologic evaluation revealed the presence of an inflammatory infiltrate of mononuclear prevalence that, on average, was nonsignificant. The histologic sections depicted mature bone with compact and cancellous areas in both groups.Conclusion: the results indicated that both graft materials associated with the autogenous bone were biocompatible, although both were still present after 10 months.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate a simple mnemonic rule (the RB-RB/LB-LB rule) for recording intra-oral radiographs with optimal projection for the control of dental implants.Methods: 30 third-year dental students received a short lesson in the RB-RB/LB-LB mnemonic rule. The rule is as follows: if right blur then raise beam (RB-RB), i.e. if implant threads are blurred at the right side of the implant, the X-ray beam direction must be raised towards the ceiling to obtain sharp threads on both implant sides; if left blur then lower beam (LB-LB), i.e. if implant threads are blurred at the left side of the implant, the X-ray beam direction must be lowered towards the floor to obtain sharp threads on both implant sides. Intra-oral radiographs of four screw-type implants placed with different inclination in a Frasaco upper or lower jaw dental model (Frasaco GmbH, Tettnang, Germany) were recorded. The students were unaware of the inclination of the implants and were instructed to re-expose each implant, implementing the mnemonic rule, until an image of the implant with acceptable quality (subjectively judged by the instructor) was obtained. Subsequently, each radiograph was blindly assessed with respect to sharpness of the implant threads and assigned to one of four quality categories: (1) perfect, (2) not perfect, but clinically acceptable, (3) not acceptable and (4) hopeless.Results: For all implants, from one non-perfect exposure to the following, a higher score was obtained in 64% of the cases, 28% received the same score and 8% obtained a lower score. Only a small variation was observed among exposures of implants with different inclination. on average, two exposures per implant (range: one to eight exposures) were needed to obtain a clinically acceptable image.Conclusion: The RB-RB/LB-LB mnemonic rule for recording intra-oral radiographs of dental implants with a correct projection was easy to implement by inexperienced examiners. Dentomaxillofacial Radiology (2012) 41, 298-304. doi: 10.1259/dmfr/20861598

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)