996 resultados para Measurement uncertainty


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zero correlation between measurement error and model error has been assumed in existing panel data models dealing specifically with measurement error. We extend this literature and propose a simple model where one regressor is mismeasured, allowing the measurement error to correlate with model error. Zero correlation between measurement error and model error is a special case in our model where correlated measurement error equals zero. We ask two research questions. First, we wonder if the correlated measurement error can be identified in the context of panel data. Second, we wonder if classical instrumental variables in panel data need to be adjusted when correlation between measurement error and model error cannot be ignored. Under some regularity conditions the answer is yes to both questions. We then propose a two-step estimation corresponding to the two questions. The first step estimates correlated measurement error from a reverse regression; and the second step estimates usual coefficients of interest using adjusted instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to design and validate the measurement of ankle kinetics (force, moment, and power) during consecutive gait cycles and in the field using an ambulatory system. An ambulatory system consisting of plantar pressure insole and inertial sensors (3D gyroscopes and 3D accelerometers) on foot and shank was used. To test this system, 12 patients and 10 healthy elderly subjects wore shoes embedding this system and walked many times across a gait lab including a force-plate surrounded by seven cameras considered as the reference system. Then, the participants walked two 50-meter trials where only the ambulatory system was used. Ankle force components and sagittal moment of ankle measured by ambulatory system showed correlation coefficient (R) and normalized RMS error (NRMSE) of more than 0.94 and less than 13% in comparison with the references system for both patients and healthy subjects. Transverse moment of ankle and ankle power showed R>0.85 and NRMSE<23%. These parameters also showed high repeatability (CMC>0.7). In contrast, the ankle coronal moment of ankle demonstrated high error and lower repeatability. Except for ankle coronal moment, the kinetic features obtained by the ambulatory system could distinguish the patients with ankle osteoarthritis from healthy subjects when measured in 50-meter trials. The proposed ambulatory system can be easily accessible in most clinics and could assess main ankle kinetics quantities with acceptable error and repeatability for clinical evaluations. This system is therefore suggested for field measurement in clinical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper study repeated games where the time repetitions of the stage game are not known or controlled by the players. We call this feature random monitoring. Kawamori's (2004) shows that perfect random monitoring is always better than the canonical case. Surprisingly, when the monitoring is public, the result is less clear-cut and does not generalize in a straightforward way. Unless the public signals are sufficiently informative about player's actions and/or players are patient enough. In addition to a discount effect, that tends to consistently favor the provision of incentives, we found an information effect, associated with the time uncertainty on the distribution of public signals. Whether payoff improvements are or not possible, depends crucially on the direction and strength of these effects. JEL: C73, D82, D86. KEYWORDS: Repeated Games, Frequent Monitoring, Random Public Monitoring, Moral Hazard, Stochastic Processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article studies how product introduction decisions relate to profitability and uncertainty in the context of multi-product firms and product differentiation. These two features, common to many modern industries, have not received much attention in the literature as compared to the classical problem of firm entry, even if the determinants of firm and product entry are quite different. The theoretical predictions about the sign of the impact of uncertainty on product entry are not conclusive. Therefore, an econometric model relating firms’ product introduction decisions with profitability and profit uncertainty is proposed. Firm’s estimated profits are obtained from a structural model of product demand and supply, and uncertainty is proxied by profits’ variance. The empirical analysis is carried out using data on the Spanish car industry for the period 1990-2000. The results show a positive relationship between product introduction and profitability, and a negative one with respect to profit variability. Interestingly, the degree of uncertainty appears to be a driving force of entry stronger than profitability, suggesting that the product proliferation process in the Spanish car market may have been mainly a consequence of lower uncertainty rather than the result of having a more profitable market. Keywords: Product introduction, entry, uncertainty, multiproduct firms, automobile JEL codes: L11, L13

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Irish Government in March 2008 set a target to identify measure and reduce the Administrative Burden (AB) of domestic regulation for businesses by 25% by the end of 2012 – on foot of a European Council invitation to all member states in March 2007. As part of a cross-Government process led by the Business Regulation Unit of the Department of Jobs, Enterprise and Innovation (DJEI), the Department of Health carried out a measurement exercise in 2012 on the main Information Obligations placed on business by legislation in the areas of Food, Nursing Homes and Pharmacy sectors.The AB baseline measurement for those information obligations is described in this report. Click here to download PDF 322KB  

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on advanced dual-wavelength digital holographic microscopy (DHM) methods, enabling single-acquisition real-time micron-range measurements while maintaining single-wavelength interferometric resolution in the nanometer regime. In top of the unique real-time capability of our technique, it is shown that axial resolution can be further increased compared to single-wavelength operation thanks to the uncorrelated nature of both recorded wavefronts. It is experimentally demonstrated that DHM topographic investigation within 3 decades measurement range can be achieved with our arrangement, opening new applications possibilities for this interferometric technique. ©2008 COPYRIGHT SPIE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The medulla oblongata (MO) contains a high density of glycinergic synapses and a particularly high concentration of glycine. The aims of this study were to measure directly in vivo the neurochemical profile, including glycine, in MO using a spin-echo-based (1)H MRS sequence at TE?=?2.8 ms and to compare it with three other brain regions (cortex, striatum and hippocampus) in the rat. Glycine was quantified in MO at TE?=?2.8 ms with a Cramér-Rao lower bound (CRLB) of approximately 5%. As a result of the relatively low level of glycine in the other three regions, the measurement of glycine was performed at TE?=?20 ms, which provides a favorable J-modulation of overlapping myo-inositol resonance. The other 14 metabolites composing the neurochemical profile were quantified in vivo in MO with CRLBs below 25%. Absolute concentrations of metabolites in MO, such as glutamate, glutamine, ?-aminobutyrate, taurine and glycine, were in the range of previous in vitro quantifications in tissue extracts. Compared with the other regions, MO had a three-fold higher glycine concentration, and was characterised by reduced (p?<?0.001) concentrations of glutamate (-50?±?4%), glutamine (-54?±?3%) and taurine (-78?±?3%). This study suggests that the functional specialisation of distinct brain regions is reflected in the neurochemical profile.