890 resultados para Material properties
Resumo:
Tissue engineering and regenerative medicine have emerged in an effort to generate replacement tissues capable of restoring native tissue structure and function, but because of the complexity of biologic system, this has proven to be much harder than originally anticipated. Silica based bioactive glasses are popular as biomaterials because of their ability to enhance osteogenesis and angiogenesis. Sol-gel processing methods are popular in generating these materials because it offers: 1) mild processing conditions; 2) easily controlled structure and composition; 3) the ability to incorporate biological molecules; and 4) inherent biocompatibility. The goal of this work was to develop a bioactive vaporization system for the deposition of silica sol-gel particles as a means to modify the material properties of a substrate at the nano- and micro- level to better mimic the instructive conditions of native bone tissue, promoting appropriate osteoblast attachment, proliferation, and differentiation as a means for supporting bone tissue regeneration. The size distribution, morphology and degradation behavior of the vapor deposited sol-gel particles developed here were found to be dependent upon formulation (H2O:TMOS, pH, Ca/P incorporation) and manufacturing (substrate surface character, deposition time). Additionally, deposition of these particles onto substrates can be used to modify overall substrate properties including hydrophobicity, roughness, and topography. Deposition of Ca/P sol particles induced apatite-like mineral formation on both two- and three-dimensional materials when exposed to body fluids. Gene expression analysis suggests that Ca/P sol particles induce upregulation osteoblast gene expression (Runx2, OPN, OCN) in preosteoblasts during early culture time points. Upon further modification-specifically increasing particle stability-these Ca/P sol particles possess the potential to serve as a simple and unique means to modify biomaterial surface properties as a means to direct osteoblast differentiation.
Resumo:
Many methodologies dealing with prediction or simulation of soft tissue deformations on medical image data require preprocessing of the data in order to produce a different shape representation that complies with standard methodologies, such as mass–spring networks, finite element method s (FEM). On the other hand, methodologies working directly on the image space normally do not take into account mechanical behavior of tissues and tend to lack physics foundations driving soft tissue deformations. This chapter presents a method to simulate soft tissue deformations based on coupled concepts from image analysis and mechanics theory. The proposed methodology is based on a robust stochastic approach that takes into account material properties retrieved directly from the image, concepts from continuum mechanics and FEM. The optimization framework is solved within a hierarchical Markov random field (HMRF) which is implemented on the graphics processor unit (GPU See Graphics processing unit ).
Resumo:
Rapid Manufacturing (RM) wurde als Schlagwort in der letzten Zeit insbesondere aus dem Bereich des Selective Laser Sintering (SLS) bekannt. In dieser inzwischen über 15-jährigen Technologieentwicklung wurden in den vergangenen Jahren bedeutende Fortschritte erzielt, die die Bauteileigenschaften nahe an die Anforderungen für End-Teile heran brachten. So ist das RM denn auch weniger aus der Sicht grösserer Losgrösse zu verstehen. Viel mehr bedeutet Rapid Manufacturing, dass die Bauteile nach einer generativen Fertigung direkt im Endprodukt resp. der Endanwendung zum Einsatz kommt. Das Selective Laser Melting, mit welchem aus metallischen Pulvermaterialien direkt Metallteile in Standardmaterialien hergestellt werden können, ist aufgrund der guten Materialeigenschaften für RM prädestiniert. In den ersten Anwendungsfeldern des SLM–Verfahrens standen die Herstellung von Werkzeugeinsätzen mit konturnaher Kühlung (Conformal Cooling) im Vordergrund, wobei diese Werkzeuge unter dem Begriff RM verstanden werden müssen, da die Werkzeuge direkt für die Endanwendung - den Spritzgussprozess - verwendet werden. Aktuelle Trends gehen jedoch in Richtung der Fertigung von Funktionsteilen z.B. für den Maschinenbau. Obwohl sich in der Fertigung komplexer Funktionsteile noch Probleme, z.B. mit in Bezug auf die generative Baurichtung überhängender Bauteilstrukturen ergeben, zeigen sich trotzdem erhebliche Vorteile eines RM mittels SLM. Neben klaren Vorteilen durch das mögliche Customizing von Bauteilen können bei kleineren Bauteilgrössen auch erhebliche Kostenvorteile erzielt werden. Allerdings zeigen die Grenzen der aktuellen Möglichkeiten, in welchen Bereichen das SLM-Verfahren weiterer Entwicklung bedarf. Themen wie Produktivität, die Problematik der nach wie vor notwendigen Supportstrukturen wie auch Qualitätssicherung müssen in den nächsten Jahren angegangen werden, wenn dieses Verfahren den Schritt hin zu einem etablierten Produktionsverfahren und damit zu breiterer Akzeptanz und Anwendung finden soll
Resumo:
Die Strahlschmelztechnologie entwickelt sich in vielen Anwendungsbereichen zu einer echten Alternative zu den konventionellen Fertigungsverfahren. Dieser Trend wird gerade durch die Verarbeitung von serienidentischen, einkomponentigen Pulvern zur Herstellung metallischer Bauteile verstärkt, wodurch sich wiederum neue Entwicklungs- und Einsatzpotentiale ergeben. Allerdings weisen die Strahlschmelzbauteile keine vollkommen übereinstimmenden Werkstoffkennwerte im Vergleich zu herkömmlich hergestellten Bauteilen auf, wodurch die Akzeptanz durch Industrie und Forschung eingeschränkt wird. Eine exakte Beschreibung (Nachweis) der Materialeigenschaften von strahlgeschmolzenen Bauteilen wird in dem Maße wichtiger, mit dem diese Verfahren zur Fertigung von Endprodukten herangezogen werden. Weiterhin spielt die Anisotropie des Gefüges strahlgeschmolzener Bauteile eine große Rolle. Aus diesem Grund wurden im RTC Duisburg umfangreiche Festigkeitsuntersuchungen (statisch und dynamisch) in Abhängigkeit von der Baulage, des Oberflächenzustandes und verschiedener Belichtungsstrategien durchgeführt. In diesem Vortrag werden ausgewählte Ergebnisse zu den Untersuchungen vorgestellt.
Resumo:
Additive, pulverbasierte Schichtbauverfahren, wie das Selektive Masken- oder La-sersintern, ermöglichen die Fertigung von komplexen Bauteilen ohne Werkzeug und Form. Aufgrund der hohen, verarbeitungsbedingten Bauraumtemperaturen kommt es während der Verarbeitung zu physikalischem und thermisch-oxidativem Abbau der eingesetzten Kunststoffpulver. Das im Bauraum nicht aufgeschmolzene Material, der so genannte Partcake, kann nach dem Bauprozess vom fertigen Bauteil entfernt und für weitere Bauprozesse verwendet werden. Zur Realisierung reproduzierbarer Bau-teileigenschaften ist jedoch eine Aufbereitung („Refreshen“) des Partcake-Pulvers notwendig. Im Rahmen des Beitrags werden Erkenntnisse zum Alterungsverhalten von Kunst-stoffpulvern vorgestellt. In einem Modellversuch wurde der Verarbeitungsprozess für PA12-Pulver nachgestellt und somit verschiedene Alterungsstufen generiert. Beson-deres Augenmerk wurde auf den Einfluss einer Materialvorbehandlung gelegt. Die gealterten Pulver wurden physikalisch und thermoanalytisch hinsichtlich ihrer verar-beitungsrelevanten Materialeigenschaften untersucht.
Resumo:
The indications for direct resin composite restorations are nowadays extended due to the development of modern resin materials with improved material properties. However, there are still some difficulties regarding handling of resin composite material, especially in large restorations. The reconstruction of a functional and individual occlusion is difficult to achieve with direct application techniques. The aim of the present publication was to introduce a new "stamp"-technique for placing large composite restorations. The procedure of this "stamp"-technique is presented by three typical indications: large single-tooth restoration, occlusal rehabilitation of a compromised occlusal surface due to erosions and direct fibre-reinforced fixed partial denture. A step-by-step description of the technique and clinical figures illustrates the method. Large single-tooth restorations can be built-up with individual, two- piece silicone stamps. Large occlusal abrasive and/or erosive defects can be restored by copying the wax-up from the dental technician using the "stamp"-technique. Even fiber-reinforced resin-bonded fixed partial dentures can be formed with this intraoral technique with more precision and within a shorter treatment time. The presented "stamp"-technique facilitates the placement of large restoration with composite and can be recommended for the clinical use.
Resumo:
Background Finite element models of augmented vertebral bodies require a realistic modelling of the cement infiltrated region. Most methods published so far used idealized cement shapes or oversimplified material models for the augmented region. In this study, an improved, anatomy-specific, homogenized finite element method was developed and validated to predict the apparent as well as the local mechanical behavior of augmented vertebral bodies. Methods Forty-nine human vertebral body sections were prepared by removing the cortical endplates and scanned with high-resolution peripheral quantitative CT before and after injection of a standard and a low-modulus bone cement. Forty-one specimens were tested in compression to measure stiffness, strength and contact pressure distributions between specimens and loading-plates. From the remaining eight, fourteen cylindrical specimens were extracted from the augmented region and tested in compression to obtain material properties. Anatomy-specific finite element models were generated from the CT data. The models featured element-specific, density-fabric-based material properties, damage accumulation, real cement distributions and experimentally determined material properties for the augmented region. Apparent stiffness and strength as well as contact pressure distributions at the loading plates were compared between simulations and experiments. Findings The finite element models were able to predict apparent stiffness (R2 > 0.86) and apparent strength (R2 > 0.92) very well. Also, the numerically obtained pressure distributions were in reasonable quantitative (R2 > 0.48) and qualitative agreement with the experiments. Interpretation The proposed finite element models have proven to be an accurate tool for studying the apparent as well as the local mechanical behavior of augmented vertebral bodies.
Resumo:
Purpose Femoral fracture is a common medical problem in osteoporotic individuals. Bone mineral density (BMD) is the gold standard measure to evaluate fracture risk in vivo. Quantitative computed tomography (QCT)-based homogenized voxel finite element (hvFE) models have been proved to be more accurate predictors of femoral strength than BMD by adding geometrical and material properties. The aim of this study was to evaluate the ability of hvFE models in predicting femoral stiffness, strength and failure location for a large number of pairs of human femora tested in two different loading scenarios. Methods Thirty-six pairs of femora were scanned with QCT and total proximal BMD and BMC were evaluated. For each pair, one femur was positioned in one-legged stance configuration (STANCE) and the other in a sideways configuration (SIDE). Nonlinear hvFE models were generated from QCT images by reproducing the same loading configurations imposed in the experiments. For experiments and models, the structural properties (stiffness and ultimate load), the failure location and the motion of the femoral head were computed and compared. Results In both configurations, hvFE models predicted both stiffness (R2=0.82 for STANCE and R2=0.74 for SIDE) and femoral ultimate load (R2=0.80 for STANCE and R2=0.85 for SIDE) better than BMD and BMC. Moreover, the models predicted qualitatively well the failure location (66% of cases) and the motion of the femoral head. Conclusions The subject specific QCT-based nonlinear hvFE model cannot only predict femoral apparent mechanical properties better than densitometric measures, but can additionally provide useful qualitative information about failure location.
Resumo:
The emerging application of long-term and high-quality ECG recording requires alternative electrodes to improve the signal quality and recording capability of surface skin electrodes. The esophageal ECG has the potential to overcome these limitations but necessitates novel recorder and lead designs. The electrode material is of particular interest, since the material has to ensure conflicting requirements like excellent biopotential recording properties and inertness. To this end, novel electrode materials like PEDOT and silver-PDMS as well as established electrode materials such as stainless steel, platinum, gold, iridium oxide, titanium nitride, and glassy carbon were investigated by long-term electrochemical impedance spectroscopy and model-based signal analysis using the derived in vitro interfacial properties in conjunction with a dedicated ECG amplifier. The results of this novel approach show that titanium nitride and iridium oxide featuring microstructured surfaces did not degrade when exposed to artificial acidic saliva. These materials provide low electrode potential drifts and insignificant signal distortion superior to surface skin electrodes making them compatible with accepted standards for ambulatory ECG. They are superior to the noble and polarizable metals such as platinum, silver, and gold that induced more signal distortions and are superior to esophageal stainless steel electrodes that corrode in artificial saliva. The study provides rigorous criteria for the selection of electrode materials for prolonged ECG recording by combining long-term in vitro electrode material properties with ECG signal quality assessment.
Resumo:
Most medical implants run on batteries, which require costly and tedious replacement or recharging. It is believed that micro-generators utilizing intracorporeal energy could solve these problems. However, such generators do not, at this time, meet the energy requirements of medical implants.This paper highlights some essential aspects of designing and implementing a power source that scavenges energy from arterial expansion and contraction to operate an implanted medical device. After evaluating various potentially viable transduction mechanisms, the fabricated prototype employs an electromagnetic transduction mechanism. The artery is inserted into a laboratory-fabricated flexible coil which is permitted to freely deform in a magnetic field. This work also investigates the effects of the arterial wall's material properties on energy harvesting potential. For that purpose, two types of arteries (Penrose X-ray tube, which behave elastically, and an artery of a Göttinger minipig, which behaves viscoelastically) were tested. No noticeable difference could be observed between these two cases. For the pig artery, average harvestable power was 42 nW. Moreover, peak power was 2.38 μW. Both values are higher than those of the current state of the art (6 nW/16 nW). A theoretical modelling of the prototype was developed and compared to the experimental results.
Resumo:
Disc degeneration, usually associated with low back pain and changes of intervertebral stiffness, represents a major health issue. As the intervertebral disc (IVD) morphology influences its stiffness, the link between mechanical properties and degenerative grade is partially lost without an efficient normalization of the stiffness with respect to the morphology. Moreover, although the behavior of soft tissues is highly nonlinear, only linear normalization protocols have been defined so far for the disc stiffness. Thus, the aim of this work is to propose a nonlinear normalization based on finite elements (FE) simulations and evaluate its impact on the stiffness of human anatomical specimens of lumbar IVD. First, a parameter study involving simulations of biomechanical tests (compression, flexion/extension, bilateral torsion and bending) on 20 FE models of IVDs with various dimensions was carried out to evaluate the effect of the disc's geometry on its compliance and establish stiffness/morphology relations necessary to the nonlinear normalization. The computed stiffness was then normalized by height (H), cross-sectional area (CSA), polar moment of inertia (J) or moments of inertia (Ixx, Iyy) to quantify the effect of both linear and nonlinear normalizations. In the second part of the study, T1-weighted MRI images were acquired to determine H, CSA, J, Ixx and Iyy of 14 human lumbar IVDs. Based on the measured morphology and pre-established relation with stiffness, linear and nonlinear normalization routines were then applied to the compliance of the specimens for each quasi-static biomechanical test. The variability of the stiffness prior to and after normalization was assessed via coefficient of variation (CV). The FE study confirmed that larger and thinner IVDs were stiffer while the normalization strongly attenuated the effect of the disc geometry on its stiffness. Yet, notwithstanding the results of the FE study, the experimental stiffness showed consistently higher CV after normalization. Assuming that geometry and material properties affect the mechanical response, they can also compensate for one another. Therefore, the larger CV after normalization can be interpreted as a strong variability of the material properties, previously hidden by the geometry's own influence. In conclusion, a new normalization protocol for the intervertebral disc stiffness in compression, flexion, extension, bilateral torsion and bending was proposed, with the possible use of MRI and FE to acquire the discs' anatomy and determine the nonlinear relations between stiffness and morphology. Such protocol may be useful to relate the disc's mechanical properties to its degree of degeneration.
Resumo:
Contraction, strike slip, and extension displacements along the Hikurangi margin northeast of the North Island of New Zealand coincide with large lateral gradients in material properties. We use a finite- difference code utilizing elastic and elastic-plastic rheologies to build large- scale, three-dimensional numerical models which investigate the influence of material properties on velocity partitioning within oblique subduction zones. Rheological variation in the oblique models is constrained by seismic velocity and attenuation information available for the Hikurangi margin. We compare the effect of weakly versus strongly coupled subduction interfaces on the development of extension and the partitioning of velocity components for orthogonal and oblique convergence and include the effect of ponded sediments beneath the Raukumara Peninsula. Extension and velocity partitioning occur if the subduction interface is weak, but neither develops if the subduction interface is strong. The simple mechanical model incorporating rheological variation based on seismic observations produces kinematics that closely match those published from the Hikurangi margin. These include extension within the Taupo Volcanic Zone, uplift over ponded sediments, and dextral contraction to the south.
Resumo:
Recent findings in the field of biomaterials and tissue engineering provide evidence that surface immobilised growth factors display enhanced stability and induce prolonged function. Cell response can be regulated by material properties and at the site of interest. To this end, we developed scaffolds with covalently bound vascular endothelial growth factor (VEGF) and evaluated their mitogenic effect on endothelial cells in vitro. Nano- (254±133 nm) or micro-fibrous (4.0±0.4 μm) poly(ɛ-caprolactone) (PCL) non-wovens were produced by electrospinning and coated in a radio frequency (RF) plasma process to induce an oxygen functional hydrocarbon layer. Implemented carboxylic acid groups were converted into amine-reactive esters and covalently coupled to VEGF by forming stable amide bonds (standard EDC/NHS chemistry). Substrates were analysed by X-ray photoelectron spectroscopy (XPS), enzyme-linked immuno-assays (ELISA) and immunohistochemistry (anti-VEGF antibody and VEGF-R2 binding). Depending on the reaction conditions, immobilised VEGF was present at 127±47 ng to 941±199 ng per substrate (6mm diameter; concentrations of 4.5 ng mm(-2) or 33.3 ng mm(-2), respectively). Immunohistochemistry provided evidence for biological integrity of immobilised VEGF. Endothelial cell number of primary endothelial cells or immortalised endothelial cells were significantly enhanced on VEGF-functionalised scaffolds compared to native PCL scaffolds. This indicates a sustained activity of immobilised VEGF over a culture period of nine days. We present a versatile method for the fabrication of growth factor-loaded scaffolds at specific concentrations.
Resumo:
The isostructural title compounds, {(C7H7N2)2[SnI4]}n, (1), and {(C7H5F2N2)2[SnI4]}n, (2), show a layered perovskite-type structure composed of anionic {[SnI4]2-}n sheets parallel to (100), which are decorated on both sides with templating benzimidazolium or 5,6-difluorobenzimidazolium cations, respectively. These planar organic heterocycles mainly form N-H...I hydrogen bonds to the terminal I atoms of the corner-sharing [SnI6] octahedra (point group symmetry 2) from the inorganic layer, but not to the bridging ones. This is in contrast to most of the reported structures of related compounds where ammonium cations are involved. Here hydrogen bonding to both types of iodine atoms and thereby a distortion of the inorganic layers to various extents is observed. For (1) and (2), all Sn-I-Sn angles are linear and no out-of-plane distortions of the inorganic layers occur, a fact of relevance in view of the material properties. The arrangement of the aromatic cations is mainly determined through the direction of the N-H...I hydrogen bonds. The coherence between organic bilayers along [100] is mainly achieved through van der Waals interactions.
Resumo:
Objective Although osteopenia is frequent in spondyloarthritis (SpA), the underlying cellular mechanisms and association with other symptoms are poorly understood. This study aimed to characterize bone loss during disease progression, determine cellular alterations, and assess the contribution of inflammatory bowel disease (IBD) to bone loss in HLA-B27 transgenic rats. Methods Bones of 2-, 6-, and 12-month-old non-transgenic, disease-free HLA-B7 and disease-associated HLA-B27 transgenic rats were examined using peripheral quantitative computed tomography, μCT, and nanoindentation. Cellular characteristics were determined by histomorphometry and ex vivo cultures. The impact of IBD was determined using [21-3 x 283-2]F1 rats, which develop arthritis and spondylitis, but not IBD. Results HLA-B27 transgenic rats continuously lost bone mass with increasing age and had impaired bone material properties, leading to a 3-fold decrease in bone strength at 12 months of age. Bone turnover was increased in HLA-B27 transgenic rats, as evidenced by a 3-fold increase in bone formation and a 6-fold increase in bone resorption parameters. Enhanced osteoclastic markers were associated with a larger number of precursors in the bone marrow and a stronger osteoclastogenic response to RANKL or TNFα. Further, IBD-free [21-3 x 283-2]F1 rats also displayed decreased total and trabecular bone density. Conclusions HLA-B27 transgenic rats lose an increasing amount of bone density and strength with progressing age, which is primarily mediated via increased bone remodeling in favor of bone resorption. Moreover, IBD and bone loss seem to be independent features of SpA in HLA-B27 transgenic rats.