722 resultados para Maraging 300 steel
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
OBJECTIVE: ,,,,,Previous studies have demonstrated a relationship between brain oxidative stress and cardiovascular regulation. We evaluated the effects of central catalase inhibition on cardiovascular responses in spontaneously hypertensive rats exposed to sidestream cigarette smoke. ,,,, ,,,, ,,,,,METHODS: ,,,,,Male Wistar Kyoto (WKY) rats and spontaneously hypertensive rats (SH) (16 weeks old) were implanted with a stainless steel guide cannula leading into the fourth cerebral ventricle (4th V). The femoral artery and vein were cannulated for arterial pressure and heart rate measurement and drug infusion, respectively. The rats were exposed to sidestream cigarette smoke for 180 minutes/day, 5 days/week for 3 weeks (CO: 100-300 ppm). The baroreflex was tested using a pressor dose of phenylephrine (8 μg/kg, bolus) and a depressor dose of sodium nitroprusside (50 μg/kg, bolus). Cardiovascular responses were evaluated before and 5, 15, 30 and 60 minutes after injection of a catalase inhibitor (3-amino-1,2,4-triazole, 0.001 g/100 μL) into the 4th V. ,,,, ,,,, ,,,,,RESULTS: ,,,,,Vehicle administration into the 4th V did not affect the cardiovascular response, whereas administration of the central catalase inhibitor increased the basal HR and attenuated the bradycardic peak (p<0.05) to a greater extent in WKY rats exposed to sidestream cigarette smoke than in WKY rats exposed to fresh air. However, in spontaneously hypertensive rats, the effect of the catalase inhibitor treatment was stronger in the fresh air condition (p<0.05). ,,,, ,,,, ,,,,,CONCLUSION: ,,,,,Administration of a catalase inhibitor into the 4th V combined with exposure to sidestream cigarette smoke has a stronger effect in WKY rats than in SH rats.
Resumo:
É apresentado o desempenho de 19 novos clones de seringueira [Hevea brasiliensis (Willd. exAdr. de Juss.) Muell. Arg.], resultantes de hibridações conduzidas no Instituto Agronômico e avaliados em experimento de pequena escala, tendo o clone RRIM 600 como testemunha. O experimento em campo obedeceu ao delineamento em blocos ao acaso, com três repetições. Com relação à produção de borracha seca, o clone IAC 40 apresentou a maior média (62,22 g/árvore/sangria) nos três anos de avaliação, seguido pelo IAC 301 (57,67 g/árvore/sangria) e pelo IAC 300 (50,61 g/árvore/sangria), com produções 154%, 138% e 123% superiores em relação ao RRIM 600 (41,04 g/árvore/sangria). Todos os clones selecionados foram vigorosos, com perímetro do caule na abertura do painel variando de 37,81 cm (IAC 317) a 50,90 cm (IAC 315). A porcentagem de plantas aptas a sangria variou de 20,0% (IAC 317) a 100% (IAC 315). Todos os clones apresentaram baixas incidências de quebra pelo vento e de secamento do painel. Não foi detectada nenhuma doença foliar em caráter epidêmico. Dos clones estudados, 15 apresentaram alta resistência à antracnose do painel, e foram superiores ao RRIM 600; os outros cinco apresentaram resistência moderada semelhante ao RRIM 600.
Resumo:
O objetivo deste trabalho foi selecionar clones de seringueira (Hevea spp.) promissores para a região do planalto do Estado de São Paulo. de uma população de 70 clones, de polinização controlada, integrantes do experimento de avaliação em pequena escala, foram avaliados 16 da série IAC 300. O experimento foi instalado na Estação Experimental de Pindorama, no espaçamento de 7 x 3 m, em delineamento de blocos casualizados, com três repetições, tendo os clones RRIM 600 e GT 1 como testemunhas. Quanto à produção de borracha seca, destacaram-se oito e dez clones superiores ao RRIM 600 e GT 1, respectivamente. Todos os clones avaliados apresentaram-se vigorosos em relação ao perímetro do caule na abertura do painel. Sete deles mostraram alta resistência; sete, resistência moderada, e dois, suscetíveis à antracnose do painel. Sugere-se sua avaliação em experimentos de grande escala, para avaliar, além da produção, os demais caracteres secundários, em diferentes ambientes, para futuras recomendações em larga escala para o Estado de São Paulo.
Resumo:
We investigated the effect of L-NAME, a nitric oxide (NO) inhibitor and sodium nitroprusside (SNP), an NO-donating agent, on pilocarpine-induced alterations in salivary flow, mean arterial blood pressure (MAP) and heart rate (HR) in rats. Male Holtzman rats (250-300 g) were implanted with a stainless steel cannula directly into the median preoptic nucleus (MnPO). Pilocarpine (10, 20, 40, 80, 160 µg) injected into the MnPO induced an increase in salivary secretion (P<0.01). Pilocarpine (1, 2, 4, 8, 16 mg/kg) ip also increased salivary secretion (P<0.01). Injection of L-NAME (40 µg) into the MnPO prior to pilocarpine (10, 20, 40, 80, 160 µg) injected into the MnPO or ip (1, 2, 4, 8, 16 mg/kg) increased salivary secretion (P<0.01). SNP (30 µg) injected into the MnPO or ip prior to pilocarpine attenuated salivary secretion (P<0.01). Pilocarpine (40 µg) injection into the MnPO increased MAP and decreased HR (P<0.01). Pilocarpine (4 mg/kg body weight) ip produced a decrease in MAP and an increase in HR (P<0.01). Injection of L-NAME (40 µg) into the MnPO prior to pilocarpine potentiated the increase in MAP and reduced HR (P<0.01). SNP (30 µg) injected into the MnPO prior to pilocarpine attenuated (100%) the effect of pilocarpine on MAP, with no effect on HR. Administration of L-NAME (40 µg) into the MnPO potentiated the effect of pilocarpine injected ip. SNP (30 µg) injected into the MnPO attenuated the effect of ip pilocarpine on MAP and HR. The present study suggests that in the rat MnPO 1) NO is important for the effects of pilocarpine on salivary flow, and 2) pilocarpine interferes with blood pressure and HR (side effects of pilocarpine), that is attenuated by NO.
Resumo:
Aim the aim of this study was to evaluate the efficacy of ultrasound in cleaning the surface of stainless steel and Ni-Ti endodontic instruments.Methodology Twenty nickel-titanium instruments (10 Quantec files and 10 Nitiflex) and 20 stainless steel K-files (10 Maillefer-Dentsply and 10 Moyco Union Broach) were removed from their original packages and evaluated using a scanning electron microscope. Scores were given for the presence of residues on the surface or the instruments. The instruments were then cleaned in an ultrasonic bath containing only distilled water or detergent solution for 15 min, and re-evaluated, using scanning electron microscopy.Results Before cleaning, a greater amount of metallic debris was observed on the nickel-titanium Quantec instruments (P < 0.05), when compared to those made of stainless steel. Statistical analysis showed that the use of ultrasound was effective for cleaning the instruments, regardless of the irrigating solution or the instruments type (P < 0.05).Conclusions the use of ultrasound proved to be an efficient method for the removal of metallic particles from the surface of stainless steel and Ni-Ti endodontic instruments.
Resumo:
We describe a numerical procedure for plotting the force-versus-time curves in elastic collisions between identical conducting balls. A system of parametric equations relating the force and the time to a dimensionless parameter is derived from the assumption of a force compatible with Hertz's theory of collision. A simple experimental arrangement consisting of a mechanical system of colliding balls and an electrical circuit containing a crystal oscillator and an electronic counter is used to measure the collision time as a function of the energy of impact. From the data we can determine the relevant parameters. The calculated results agree very well with the expected values and are consistent with the assumption that the collisions are elastic. (C) 2006 American Association of Physics Teachers.
Resumo:
Coatings are largely used in industries. However the development of new materials with improved properties still feeds a continuous need for performance, cost or endurance, the coatings are obtained by a hybrid material, organic-inorganic, and this polymer is applied on metallic, ceramic and glassy surfaces. The material generated in-situ on the desired surface has a nanometric structure. Results in abrasion loss (according ASTM standards) showed that the coatings improve the abrasion resistance of stainless steel by 30%, and also, diminish oxidization and surface rugosity.
Resumo:
The central injection of clonidine (an alpha-2-adrenoceptor agonist) in conscious normotensive rats produces hypertensive responses and bradycardia. The present study was performed to investigate the effect of electrolytic lesions of the lateral hypothalamus (LH) on the pressor and bradycardic responses induced by clonidine injected into the medial septal area (MSA) in conscious and unrestrained rats. Male Holtzman rats weighing 250-300 g were used. Mean arterial pressure and heart rate were recorded in sham- or bilateral LH-lesioned rats with a cerebral stainless steel cannula implanted into the MSA. The injection of clonidine (40 nmol/mu-l) into the MSA of sham rats (N = 8) produced a pressor response (36 +/- 7 mmHg, P<0.05) and bradycardia (-70 +/- 13 bpm, P<0.05) compared to saline. Fourteen days after LH-lesion (N = 9) the pressor response was reduced (9 +/- 10 mmHg, P<0.05) but no change was observed in the bradycardia (-107 +/- 24 bpm). These results show that LH is an important area involved in the pressor response to clonidine injected into the MSA of rats.
Resumo:
In this paper the performances of different cutting fluids and grinding wheel types were analysed in the grinding of SAE HVN-3 workpieces. The resulting residual stress, wheel wear and roughness were evaluated. The influence of the cutting fluid jet velocity v(j) was also analysed. As a conclusion, the lubrication ability seems to be the governing factor in the cutting fluid performance. The use of CBN wheels can significantly reduce the thermal damage in grinding, leading to compressive residual stresses. The CBN wheel and the cutting oil give an optimum combination for performing this grinding operation.
Resumo:
The precipitation behaviour of a nickel free stainless steel containing 25% chromium, 17% manganese and 0.54% nitrogen, with duplex ferritic-austenitic microstructure, was studied using several complementary techniques of microstructural analysis after aging heat treatments between 600 and 1 000 degrees C for periods of lime between 15 and 6 000 min. During aging heat treatments, ferrite was decomposed into sigma phase and austenite by a eutectoid reaction, like in the Fe-Cr-Ni duplex stainless steel. Chromium nitride precipitation occurred in austenite, which had a high nitrogen supersaturation. Some peculiar aspects were observed in this austenite during its phase transformations. Chromium nitride precipitation occurred discontinuously in a lamellar morphology, such as pearlite in carbon steels. This kind of precipitation is not an ordinary observation in duplex stainless steels and the high levels of nitrogen in austenite can induce this type of precipitation, which has not been previously reported in duplex stainless steels. After chromium nitride precipitation in austenite, it was also observed sigma phase formation near the cells or colonies of discontinuously precipitated chromium nitride. Sigma phase formation was made possible by the depletion of nitrogen in those regions. Time-temperature-transformation (precipitation) diagrams were determined.
Resumo:
Despite the fact that chromium electrodeposition results in protection against wear and corrosion, combined with chemical resistance and good lubricity, the reduction in fatigue strength of base metal and environmental requirements causes one to search for possible alternatives. To improve the fatigue and corrosion resistance of AISI 4340 steel, an experimental study has been made for an intermediate electroless nickel layer deposited on base metal. The objective of this study was to analyze the effect of nickel underplate on the fatigue and corrosion strength of hard-chromium-plated AISI 4340 steel. Deposition of the conventional wear-resistant hard chromium plating leads to a decrease in mechanical properties of the base metal, especially the fatigue strength. Rotating bending fatigue tests results indicate better performance for conventional hard chromium plating. Good corrosion resistance in salt fog exposure was obtained for the accelerated hard chromium plating. Experimental data showed higher fatigue and corrosion resistance for samples prepared with accelerated hard chromium plate over electroless nickel plate, when compared with samples without electroless nickel underplate.