934 resultados para MAN
Resumo:
This article examines social network users’ legal defences against content removal under the EU and ECHR frameworks, and their implications for the effective exercise of free speech online. A review of the Terms of Use and content moderation policies of two major social network services, Facebook and Twitter, shows that end users are unlikely to have a contractual defence against content removal. Under the EU and ECHR frameworks, they may demand the observance of free speech principles in state-issued blocking orders and their implementation by intermediaries, but cannot invoke this ‘fair balance’ test against the voluntary removal decisions by the social network service. Drawing on practical examples, this article explores the threat to free speech created by this lack of accountability: Firstly, a shift from legislative regulation and formal injunctions to public-private collaborations allows state authorities to influence these ostensibly voluntary policies, thereby circumventing constitutional safeguards. Secondly, even absent state interference, the commercial incentives of social media cannot be guaranteed to coincide with democratic ideals. In light of the blurring of public and private functions in the regulation of social media expression, this article calls for the increased accountability of the social media services towards end users regarding the observance of free speech principles
Resumo:
AIMS To assess serially the edge vascular response (EVR) of a bioresorbable vascular scaffold (BVS) compared to a metallic everolimus-eluting stent (EES). METHODS AND RESULTS Non-serial evaluations of the Absorb BVS at one year have previously demonstrated proximal edge constrictive remodelling and distal edge changes in plaque composition with increase of the percent fibro-fatty (FF) tissue component. The 5 mm proximal and distal segments adjacent to the implanted devices were investigated serially with intravascular ultrasound (IVUS), post procedure, at six months and at two years, from the ABSORB Cohort B1 (n=45) and the SPIRIT II (n=113) trials. Twenty-two proximal and twenty-four distal edge segments were available for analysis in the ABSORB Cohort B1 trial. In the SPIRIT II trial, thirty-three proximal and forty-six distal edge segments were analysed. At the 5-mm proximal edge, the vessels treated with an Absorb BVS from post procedure to two years demonstrated a lumen loss (LL) of 6.68% (-17.33; 2.08) (p=0.027) with a trend toward plaque area increase of 7.55% (-4.68; 27.11) (p=0.06). At the 5-mm distal edge no major changes were evident at either time point. At the 5-mm proximal edge the vessels treated with a XIENCE V EES from post procedure to two years did not show any signs of LL, only plaque area decrease of 6.90% (-17.86; 4.23) (p=0.035). At the distal edge no major changes were evident with regard to either lumen area or vessel remodelling at the same time point. CONCLUSIONS The IVUS-based serial evaluation of the EVR up to two years following implantation of a bioresorbable everolimus-eluting scaffold shows a statistically significant proximal edge LL; however, this finding did not seem to have any clinical implications in the serial assessment. The upcoming imaging follow-up of the Absorb BVS at three years is anticipated to provide further information regarding the vessel wall behaviour at the edges.