923 resultados para Low voltage direct current


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The proposed of scanning of an electrical industrial substation HV is associated with a segment of the Electrotechnical area and aims the study and preliminary application of digital technologies in the protection, control, measurement and automation maneuvers aimed at a Industrial Electrical System typical High Voltage. Well intended to supervision, protection and control of major electrical and thermal quantities involved in a substation, such as voltage levels, current, temperature, power factor, loads of transformers and circuit feeders, status of interlocking devices, switching equipment maneuvers, etc

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrical installations in industries involving high currents and voltages considered. On the other side is the common appearance of electrical failures, caused by human error, defects in electrical equipment or electrical installation aging itself. These failures are varied, those with the highest rate of occurrence and cause much damage to electrical installations, are overcurrent and overvoltage. Therefore there is a need to project a system that can detect and minimize possible effects caused by faults in electrical installations industries. Protection systems in electric industries emerge as an alternative to control especially voltage and current magnitudes. Engineered based on the functions of the relays, protection systems are an indispensable tool for any industrial substation. But the project of such systems becomes increasingly more complex, due to technological development. Electrical equipment not develop at the same speed that the protective devices (relays), making it indispensable knowledge of integration of technologies

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The optimal supply chain management (SCM) is considered by the companies a new frontier in order to gain efficiently competitive advantage. Through the SCM companies must define their competitive strategies by positioning inside the supply chain wich belongs both as suppliers and as consumers. The main objectives of SCM is integrate multiple suppliers to satisfy the market demand and make possible the synergies between the parts of the supply chain in order to better serve the consumer Meanwhile, selection, evaluation and development of suppliers play important roles in establishing an efficient supply chain. Thus, the SCM covers elements such as manufacturing, assembly, raw materials, and distribution to the final consumer. Due to the factors described, the focus of this paper is to present the Analytic Hierarchical Process (AHP) application as an appropriate and structured method for the supplier selection of a strategic line of low voltage transformers of a transformers industry and compare it with the selection process currently used by this industry, showing the advantages of applying a multiple criteria decision making method. In this study, the research methodology used was modeling and simulation

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work deals with the development of a switched-mode power supply circuit based on a Buck topology converter with a Boost Rectifier One-Cycle Control with Power Factor Correction developing, thus, a source of direct current for a module of 50 power LEDs that will be used in a lamp for public street lightning. It is presented, at first, some aspects about the most common technologies used in lamps of public street lightning in Brazil and a comparison with the White LED high power, which is the one that presents itself as the most promising among the existing market. Then it is presented the detailed development of the static converter switched PWM, consisting of a Boost rectifier with power factor correction and methodology of control One-Cycle Control associated with a Buck converter controlled by a PI method that operates as a direct current source . At the end of the simulation results of the circuit through the PSIM software are presented to verify the design behavior

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the development of an electro-mechanical micro-discharges device operating at ambient condition of pressure and temperature, capable to produce plasma jets for surface finishing. The discharges are produced through a needle shape electrode hollow cathode type by which flows the helium gas. The voltage applied on the electrode is provided for an AC/AC switching voltage converter of full-bridge topology. The converter is energized by a power line of 110/220 VAC, 60 Hz and gives a 1000 V peak-to-peak from 5 kHz to 40 kHz square waveform output. The output frequency is defined by a control signal provided by an external signal generator. The equipment setup includes output acquisition of voltage and current and a photo-detector for photo-electrical measurements, which allows an optical characterization of the plasma jet

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is important to ensure smoothly operation of a transmission line, sending energy to the consumption centers with minimal interruptions and safer. With this necessity, the fault location techniques have grown, in order to mitigate the impact of the fault and its correction can be more quickly and accurately. This paper presents a comparison between two different techniques of fault location, the fault location by impedance method, which uses the line parameters, the impedance per distance, voltage and current signals, and the other is the traveling wave method, which uses only a very fast analysis of time, synchronization and length between the line ends, do not using voltage and current values, but the temporal perception of the fault. Using travelling waves fault detection makes the previous knowledge of line parameters obsolete, which helps a lot network technicians and engineers with a quick and easy analysis. The methods are simulated in ATP Draw software, so both algorithms can be evaluated for their effectively and accuracy

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the development of an electro-mechanical micro-discharges device operating at ambient condition of pressure and temperature, capable to produce plasma jets for surface finishing. The discharges are produced through a needle shape electrode hollow cathode type by which flows the helium gas. The voltage applied on the electrode is provided for an AC/AC switching voltage converter of full-bridge topology. The converter is energized by a power line of 110/220 VAC, 60 Hz and gives a 1000 V peak-to-peak from 5 kHz to 40 kHz square waveform output. The output frequency is defined by a control signal provided by an external signal generator. The equipment setup includes output acquisition of voltage and current and a photo-detector for photo-electrical measurements, which allows an optical characterization of the plasma jet

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is important to ensure smoothly operation of a transmission line, sending energy to the consumption centers with minimal interruptions and safer. With this necessity, the fault location techniques have grown, in order to mitigate the impact of the fault and its correction can be more quickly and accurately. This paper presents a comparison between two different techniques of fault location, the fault location by impedance method, which uses the line parameters, the impedance per distance, voltage and current signals, and the other is the traveling wave method, which uses only a very fast analysis of time, synchronization and length between the line ends, do not using voltage and current values, but the temporal perception of the fault. Using travelling waves fault detection makes the previous knowledge of line parameters obsolete, which helps a lot network technicians and engineers with a quick and easy analysis. The methods are simulated in ATP Draw software, so both algorithms can be evaluated for their effectively and accuracy