973 resultados para Low level laser therapy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOAR

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This study sought to assess if discoloration of tooth structures occurs after photodynamic therapy (PDT) and to determine the efficacy of a protocol to remove the photosensitizers. Background data: PDT has been used in root canal treatment to enhance cleaning and disinfection of the root canal system. PDT uses a low power laser in association with a dye as a photosensitizer. Photosensitizers can induce staining of the dental structures, resulting in an unaesthetic appearance. Methods: Forty teeth were randomly divided into four groups according to the photosensitizer used and pre-irradiation time: 0.01% methylene blue for 5 min (MB5); 0.01% methylene blue for 10 min (MB 10); 0.01% toluidine blue for 5 min (TB5); and 0.01% toluidine blue for 10 min (TB 10). Specimens were irradiated with a 660 nm diode laser with a 300 mu m diameter optical fiber, at 40 mW power setting for 3 min. Immediately after, the photosensitizers were removed with Endo-PTC cream +2.5% sodium hypochlorite (NaOCl). The shade was measured by a Vita Easyshade spectrophotometer based on the CIELAB color system (L*a*b* values) at three different experimental times: before PDT (T0), immediately after PDT (T1), and after removal of the photosensitizer (T2). Results: The results showed a decrease in the averages of the L*a*b* coordinate values after PDT (T1) in all the groups, when compared with the number at T0, with a significant statistical difference in group MB10. After photosensitizer removal (T2), all the values of the coordinates increased with significant statistical differences (p < 0.05) between T1 and T2 in L* and a*. Conclusions: It can be concluded that both methylene blue and toluidine blue dyes cause tooth discoloration, and that Endo-PTC cream associated with 2.5% NaOCl effectively remove these dyes, regardless of the pre-irradiation time used for PDT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this trial was to investigate changes occurring in the subgingival microbiological composition of subjects with aggressive periodontitis, treated with antimicrobial photodynamic therapy (aPDT), in a single episode, or scaling and root planing (SRP), in a split-mouth design on -7, 0, and +90 days. Ten patients were randomly assigned to either aPDT using a laser source in conjunction with a photosensitizer or SRP with hand instruments. Subgingival plaque samples were collected and the counts of 40 subgingival species were determined using checkerboard DNA-DNA hybridization. The data were analyzed using the method of generalized estimating equations (GEE) to test the associations between treatments, evaluated parameters, and experimental times (alpha = .05). The results indicated that aPDT and SRP affects different bacterial species, with aPDT being effective in reducing numbers of A. actinomycetemcomitans than SRP. On the other hand, SRP was more efficient than aPDT in reducing the presence of periodontal pathogens of the Red Complex. Additionally, a recolonization in the sites treated by aPDT was observed, especially for T. forsythia and P. gingivalis. Under our experimental conditions, this trial demonstrates that aPDT and SRP affected different groups of bacteria, suggesting that their association may be beneficial for the non-surgical treatment of aggressive periodontitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dentin wall structural changes caused by 810-nm-diode laser irradiation can influence the sealing ability of endodontic sealers. The objective of this study was to evaluate the apical leakage of AH Plus and RealSeal resin-based sealers with and without prior diode laser irradiation. Fifty-two single-rooted mandibular premolars were prepared and divided into 4 groups, according to the endodontic sealer used and the use or non-use of laser irradiation. The protocol for laser irradiation was 2.5W, continuous wave in scanning mode, with 4 exposures per tooth. After sample preparation, apical leakage of 50% ammoniacal silver nitrate impregnation was analyzed. When the teeth were not exposed to irradiation, the Real Seal sealer achieved the highest scores, showing the least leakage, with significant differences at the 5% level (Kruskal-Wallis test, p = 0.0004), compared with AH Plus. When the teeth were exposed to the 810-nm-diode laser irradiation, the sealing ability of AH Plus sealer was improved (p = 0282). In the Real Seal groups, the intracanal laser irradiation did not interfere with the leakage index, showing similar results in the GRS and GRSd groups (p = 0.1009).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To perform a systematic review on the effect of changes in incisor inclination owing to orthodontic treatment and the occurrence of gingival recession. PubMed, EMBASE Excerpta Medica and CENTRAL of the Cochrane Library were searched and a hand search was performed. From 1925 articles identified, 17 articles were finally included: six experimental animal studies and 11 retrospective clinical studies in humans. More proclined teeth compared with less proclined teeth or untreated teeth had in most studies a higher occurrence or severity of gingival recession. Contradictory results were found regarding a possible statistically significant correlation between the extent of gingival recession and the amount of incisor proclination during treatment, width of attached gingiva, hygiene, periodontal condition or thickness of the symphysis. There are no high quality animal or clinical studies on this topic. Movement of the incisors out of the osseous envelope of the alveolar process may be associated with a higher tendency for developing gingival recessions. The amount of recession found in studies with statistically significant differences between proclined and non-proclined incisors is small and the clinical consequence questionable. Because of the low level of evidence of the included studies, the results should be considered with caution. Further randomized clinical studies including clinical examination of hygiene and gingival condition before, during and after treatment are needed to clarify the effect of orthodontic changes in incisor inclination and the occurrence of gingival recession.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Changes in CD4 cell counts are poorly documented in individuals with low or moderate-level viremia while on antiretroviral treatment (ART) in resource-limited settings. We assessed the impact of on-going HIV-RNA replication on CD4 cell count slopes in patients treated with a first-line combination ART. Method Naïve patients on a first-line ART regimen with at least two measures of HIV-RNA available after ART initiation were included in the study. The relationships between mean CD4 cell count change and HIV-RNA at 6 and 12 months after ART initiation (M6 and M12) were assessed by linear mixed models adjusted for gender, age, clinical stage and year of starting ART. Results 3,338 patients were included (14 cohorts, 64% female) and the group had the following characteristics: a median follow-up time of 1.6 years, a median age of 34 years, and a median CD4 cell count at ART initiation of 107 cells/μL. All patients with suppressed HIV-RNA at M12 had a continuous increase in CD4 cell count up to 18 months after treatment initiation. By contrast, any degree of HIV-RNA replication both at M6 and M12 was associated with a flat or a decreasing CD4 cell count slope. Multivariable analysis using HIV-RNA thresholds of 10,000 and 5,000 copies confirmed the significant effect of HIV-RNA on CD4 cell counts both at M6 and M12. Conclusion In routinely monitored patients on an NNRTI-based first-line ART, on-going low-level HIV-RNA replication was associated with a poor immune outcome in patients who had detectable levels of the virus after one year of ART.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Type 1 diabetes mellitus is caused by severe insulin deficiency secondary to the autoimmune destruction of pancreatic beta cells. Patients need to be controlled by periodic insulin injections to prevent the development of ketoacidosis, which can be fatal. Sustained, low-level expression of the rat insulin 1 gene from the liver of severely diabetic rats was achieved by in vivo administration of a recombinant retroviral vector. Ketoacidosis was prevented and the treated animals exhibited normoglycemia during a 24-hr fast, with no evidence of hypoglycemia. Histopathological examination of the liver in the treated animals showed no apparent abnormalities. Thus, the liver is an excellent target organ for ectopic expression of the insulin gene as a potential treatment modality for type 1 diabetes mellitus by gene therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study Design. A comparative study of trunk and hip extensor muscle recruitment patterns in 2 subject groups. Objective. To examine for changes in recruitment of the hip and back extensor muscles during low level isometric trunk rotation efforts in chronic low back pain (CLBP) subjects by comparison with matched asymptomatic control subjects. Summary of Background Data. Anatomic and biomechanical models have provided evidence that muscles attaching to the thoracolumbar fascia (TLF) are important for providing stabilization to the lumbopelvic region during trunk rotation. This has guided rehabilitation programs. The muscles that link diagonally to the posterior layer of the TLF have not previously been examined individually and compared during low-level trunk rotation efforts in CLBP patients and matched controls. Methods. Thirty CLBP patients and 30 matched controls were assessed using surface electromyography (EMG) as they performed low-level isometric rotation efforts while standing upright. Muscles studied included latissimus dorsi, erector spinae, upper and lower gluteus maximus, and biceps femoris. Subjects performed the rotation exertion with various levels of external trunk support, related to different functional tasks. Results. EMG results demonstrated that subjects with CLBP had significantly higher levels of recruitment for the lower and upper gluteus maximus (P < 0.05), hamstrings (P < 0.05), and erector spinae muscles (P < 0.05) during rotation to the left compared with the control subjects. Conclusion. This study provided evidence of increased muscle recruitment in CLBP patients when performing a standardized trunk rotation task. These results may have implications for the design of therapeutic exercise programs for CLBP patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente estudo avaliou a velocidade da movimentação ortodôntica e as alterações dentárias e esqueléticas na distalização de molares superiores sob influência do laser de baixa intensidade por meio de telerradiografias laterais. A amostra foi constituída por 18 pacientes, portadores de maloclusão Classe II, com idade média inicial de 14,4 anos e divididos em dois grupos: Grupo I - laser e Grupo II - controle. Os pacientes foram tratados com um dispositivo ortodôntico denominado Pêndulo de Hilgers modificado, concomitantemente foi realizado a aplicação do laser de baixa intensidade na região radicular dos primeiros e segundos molares superiores, dos lados direito e esquerdo, nos pacientes do grupo I, sob o seguinte protocolo: 780nm de comprimento de onda, 40mW de potência, 10J/cm² de densidade de energia, 0,4J de energia por ponto durante 10 segundos cada e resultando em energia total de 20,8J. Foram distribuídos 52 pontos por vestibular e palatina dos primeiros e segundos molares superiores. A aplicação do laser foi realizada no dia da ativação da mola de TMA e repetida a cada mês até a sobrecorreção da relação molar. As telerradiografias laterais foram realizadas no início do tratamento (T1), ao final do terceiro mês (T2) e ao final da distalização (T3) com a relação molar sobrecorrigida em aproximadamente 1mm. Após análise cefalométrica foram realizadas comparações das alterações obtidas entre as fases Inicial (T1) e Final (T3) e Inicial (T1) e terceiro mês (T2) e comparadas entre os grupos. Os resultados mostraram inclinação para distal dos primeiros e segundos molares superiores, inclinação vestibular dos incisivos centrais superiores acentuada pela presença dos segundos molares e ausência de alterações dentárias verticais significativas, rotação do plano mandibular no sentido horário e o consequente aumento da altura facial anterior inferior. Concluiu-se que os efeitos do Pêndulo de Hilgers modificado sob a metodologia realizada provocaram alterações predominantemente dentoalveolares e que a movimentação dos primeiros e segundos molares superiores sob efeito da laserterapia, não apresentou diferença estatisticamente significante na velocidade de movimentação ortodôntica e em nenhuma das variáveis estudadas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the frequency of different types of glaucoma at the Hospital das Clínicas of Campinas State University. METHODS: Cross-sectional study of 329 patients followed at the Glaucoma Service of Campinas State University from October 1 to December 20, 2000. The frequency of each type of glaucoma and the treatment were analyzed. RESULTS: There were 329 patients examined at the Glaucoma Service: 132 (40.1%) were referred to the service as glaucoma suspects and 197 (59.9%) as glaucoma patients. Ninety of the 132 glaucoma suspects had glaucoma (68.2%) and 42 are still under investigation (31.8%). Among the 329 patients, 283 (86%) had glaucoma, 42 (12.8%) were glaucoma suspects, 2 (0.6%) had ocular hypertension and 2 (0.6%) did not have glaucoma. There were 530 eyes with glaucoma: 298 (56.2%) with primary open angle glaucoma, 108 (20.4%) with chronic angle closure glaucoma, 21 (4%) with glaucoma following cataract surgery, 19 (3.6%) congenital glaucoma and 16 (3%) with low-tension glaucoma. All patients received initial clinical treatment with IOP-lowering medication. After a mean follow up of 10.5 months, 89 (16.8%) underwent laser therapy: 72 (13.6%) iridotomy, 7 (1.3%) trabeculoplasty and 10 (1.9%) panphotocoagulation. A hundred and seventy nine (33%) eyes required surgical treatment. CONCLUSION: The most frequent types of glaucoma were primary open angle and angle closure glaucoma. Low tension glaucoma and glaucoma associated with exfoliation syndrome were uncommon in this population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this study was the evaluation of two different photosensitizers activated by red light emitted by light-emitting diodes (LEDs) in the decontamination of carious bovine dentin. Materials and Methods: Fifteen bovine incisors were used to obtain dentin samples which were immersed in brain-heart infusion culture medium supplemented with 1% glucose, 2% sucrose, and 1% young primary culture of Lactobacillus acidophilus 108 CFU/mL and Streptococcus mutans 108 CFU/mL for caries induction. Three different concentrations of the Photogem solution, a hematoporphyrin derivative (1, 2, and 3 mg/mL) and two different concentrations of toluidine blue O (TBO), a basic dye (0.025 and 0.1 mg/mL) were used. To activate the photosensitizers two different light exposure times were used: 60 sec and 120 sec, corresponding respectively to the doses of 24 J/cm(2) and 48 J/cm(2). Results: After counting the numbers of CFU per milligram of carious dentin, we observed that the use of LED energy in association with Photogem or TBO was effective for bacterial reduction in carious dentin, and that the greatest effect on S. mutans and L. acidophilus was obtained with TBO at 0.1 mg/mL and a dose of 48 J/cm(2). It was also observed that the overall toxicity of TBO was higher than that of Photogem, and that the phototoxicity of TBO was higher than that of Photogem. Conclusion: Based on our data we propose a mathematical model for the photodynamic effect when different photosensitizer concentrations and light doses are used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bittar CK, Cliquet A Jr, dos Santos Floter M: Utility of quantitative ultrasound of the calcaneus in diagnosing osteoporosis in spinal cord injury patients. Am J Phys Med Rehabil 2011;90:477-481. Objective: The aim of this study was to assess the utility of quantitative ultrasound of the calcaneus in diagnosing osteoporosis in spinal cord injury patients in a Brazilian Teaching Hospital. Design: This is a diagnostic test criterion standard comparison study. Between January 2008 and October 2009, the bone density of 15 spinal cord injury patients was assessed for analysis before beginning rehabilitation using muscle stimulation. The bone density was assessed using bone densitometry examination (DEXA) and ultrasound examination of the calcaneus (QUS). The measurements acquired using QUS and DEXA were compared between patients with spinal cord injury and a control group of ten healthy individuals. Results: The T-score values for femoral neck using DEXA (P < 0.0022) and those using QUS of the calcaneus (P < 0.0005) differed significantly between the groups, and the means in the normal subjects were higher than those in spinal cord injury patients who would receive electrical stimulation. In spinal cord injury patients, the significant differences were found between the QUS T-score for calcaneus and the DEXA scores for the lumbar spine and femoral neck. Conclusions: Because of the low level of mechanical stress on the calcaneus, the results of the QUS could not be correlated with the DEXA results for diagnosing osteoporosis. Therefore, QUS seems to be not a good choice for diagnosis and follow-up.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the fabrication of two-dimensional diffraction gratings in diamond-like carbon (DLC) thin films, with applications in computer-generated holography and micro optics. In order to achieve high diffraction efficiency and to have a very simple manufacturing process, the device is designed to modulate only the phase of an incoming coherent monochromatic laser beam (632.8 nm, HeNe laser). This modulation is obtained by implementing a binary microrelief in the DLC film, responsible for generating a localized optical path difference of half a wavelength. This microrelief is obtained by anisotropic reactive ion etching of the DLC surface in an oxygen based plasma. The DLC layer was grown by reactive magnetron sputtering, using a methane-based plasma chemistry. AFM measurements show a low-level surface roughness of less than 1% of the operation wavelength, and optical characterization shows a good quality of the reconstructed diffraction patterns. (C) 2010 Elsevier B.V. All rights reserved.