924 resultados para Lincoln Electric Light and Power Company
Resumo:
Plant performance is significantly influenced by prevailing light and temperature conditions during plant growth and development. For plants exposed to natural fluctuations in abiotic environmental conditions it is however laborious and cumbersome to experimentally assign any contribution of individual environmental factors to plant responses. This study aimed at analyzing the interplay between light, temperature and internode growth based on model approaches. We extended the light-sensitive virtual plant model L-Cucumber by implementing a common Arrhenius function for appearance rates, growth rates, and growth durations. For two greenhouse experiments, the temperature-sensitive model approach resulted in a precise prediction of cucumber mean internode lengths and number of internodes, as well as in accurately predicted patterns of individual internode lengths along the main stem. In addition, a system's analysis revealed that environmental data averaged over the experimental period were not necessarily related to internode performance. Finally, the need for a species-specific parameterization of the temperature response function and related aspects in modeling temperature effects on plant development and growth is discussed.
Resumo:
The marine dinoflagellate genus Dinophysis includes species that are the causative agents of diarrhetic shellfish poisoning (DSP). Recent findings indicate that some Dinophysis species are mixotrophic, i.e. capable of both autotrophic and heterotrophic nutrition. We investigated inorganic (and organic) carbon uptake by several species of Dinophysis in the Light and dark using the 'single-cell C-14 method', and compared uptake rates with those of photosynthetic Ceratium species and heterotrophic dinoflagellates in the genus Protoperidinium. Experiments were conducted with water from the Gullmar Fjord and from the Koster Strait (Swedish west coast). Nutrient-enriched phytoplankton from surface water samples were concentrated (20 to 70 mu m) and incubated at in situ temperature under artificial light conditions with high concentrations of inorganic C-14 (1 mu Ci ml(-1)). Individual cells of each desired species were manually isolated under a microscope and transferred to scintillation vials. C. tripes showed net C-14 uptake only during light periods, whereas both C. lineatum and C. furca showed C-14 uptake in the Light as well as uptake (and sometimes losses) in the dark. Dinophysis species had similar carbon fixation rates in Light compared to Ceratium species. For D. acuminata and D. norvegica, net carbon uptake occurred in both Light and dark periods. D. acuta showed a loss of carbon in the dark in one experiment, but in another, dark C uptake was significantly higher than uptake in Light. When exposed to Light, C. furca, D. norvegica and D. acuta had high specific carbon uptake rates. Growth rates for the different species were calculated from C-14 uptake by the cells during the first hours of incubation in light. D. acuminata and D. norvegica had similar maximum growth rates, 0.59 and 0.63 d(-1) (mu); the maximum growth rate of D. acuta was lower (0.41 d(-1)). The positive dark carbon uptake by Dinophysis may suggest a mixotrophic mode of nutrition. In one experiment, both D. norvegica and D. acuta showed a significantly higher carbon uptake in a dark bottle than in a Light bottle, which would be consistent with uptake of C-14-labeled organic matter by D. norvegica and D. acuta. Demonstration of direct uptake of dissolved and particulate organic matter would provide conclusive evidence of mixotrophy and this will require the development of new protocols for measuring organic matter uptake applicable to Dinophysis in the natural assemblages.
Resumo:
Public participation in health-service management is an increasingly prominent policy internationally. Frequently, though, academic studies have found it marginalized by health professionals who, keen to retain control over decision-making, undermine the legitimacy of involved members of the public, in particular by questioning their representativeness. This paper examines this negotiation of representative legitimacy between staff and involved users by drawing on a qualitative study of service-user involvement in pilot cancer-genetics services recently introduced in England, using interviews, participant observation and documentary analysis. In contrast to the findings of much of the literature, health professionals identified some degree of representative legitimacy in the contributions made by users. However, the ways in which staff and users constructed representativeness diverged significantly. Where staff valued the identities of users as biomedical and lay subjects, users themselves described the legitimacy of their contribution in more expansive terms of knowledge and citizenship. My analysis seeks to show how disputes over representativeness relate not just to a struggle for power according to contrasting group interests, but also to a substantive divergence in understanding of the nature of representativeness in the context of state-orchestrated efforts to increase public participation. This divergence might suggest problems with the enactment of such aspirations in practice; alternatively, however, contestation of representative legitimacy might be understood as reflecting ambiguities in policy-level objectives for participation, which secure implementation by accommodating the divergent constructions of those charged with putting initiatives into practice.
Resumo:
168 p.
Resumo:
L'obiettivo di questo lavoro è quello di analizzare la potenza emessa da una carica elettrica accelerata. Saranno studiati due casi speciali: accelerazione lineare e accelerazione circolare. Queste sono le configurazioni più frequenti e semplici da realizzare. Il primo passo consiste nel trovare un'espressione per il campo elettrico e il campo magnetico generati dalla carica. Questo sarà reso possibile dallo studio della distribuzione di carica di una sorgente puntiforme e dei potenziali che la descrivono. Nel passo successivo verrà calcolato il vettore di Poynting per una tale carica. Useremo questo risultato per trovare la potenza elettromagnetica irradiata totale integrando su tutte le direzioni di emissione. Nell'ultimo capitolo, infine, faremo uso di tutto ciò che è stato precedentemente trovato per studiare la potenza emessa da cariche negli acceleratori.
Resumo:
Non-orthogonal multiple access (NOMA) is emerging as a promising multiple access technology for the fifth generation cellular networks to address the fast growing mobile data traffic. It applies superposition coding in transmitters, allowing simultaneous allocation of the same frequency resource to multiple intra-cell users. Successive interference cancellation is used at the receivers to cancel intra-cell interference. User pairing and power allocation (UPPA) is a key design aspect of NOMA. Existing UPPA algorithms are mainly based on exhaustive search method with extensive computation complexity, which can severely affect the NOMA performance. A fast proportional fairness (PF) scheduling based UPPA algorithm is proposed to address the problem. The novel idea is to form user pairs around the users with the highest PF metrics with pre-configured fixed power allocation. Systemlevel simulation results show that the proposed algorithm is significantly faster (seven times faster for the scenario with 20 users) with a negligible throughput loss than the existing exhaustive search algorithm.
Resumo:
The goal of this simulation thesis is to present a tool for studying and eliminating various numerical problems observed while analyzing the behavior of the MIND cable during fast voltage polarity reversal. The tool is built on the MATLAB environment, where several simulations were run to achieve oscillation-free results. This thesis will add to earlier research on HVDC cables subjected to polarity reversals. Initially, the code does numerical simulations to analyze the electric field and charge density behavior of a MIND cable for certain scenarios such as before, during, and after polarity reversal. However, the primary goal is to reduce numerical oscillations from the charge density profile. The generated code is notable for its usage of the Arithmetic Mean Approach and the Non-Uniform Field Approach for filtering and minimizing oscillations even under time and temperature variations.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
As a fundamental contribution to limiting the increase of debris in the Space environment, a three-year project started on 1 November 2010 financed by the European Commission under the FP-7 Space Programme. It aims at developing a universal system to be carried on board future satellites launched into low Earth orbit (LEO), to allow de-orbiting at end of life. The operational system involves a conductive tape-tether left bare of insulation to establish anodic contact with the ambient plasma as a giant Langmuir probe. The project will size the three disparate dimensions of a tape for a selected de-orbit mission and determine scaling laws to allow system design for a general mission. It will implement control laws to restrain tether dynamics in/off the orbital plane; and will carry out plasma chamber measurements and numerical simulations of tether-plasma interaction. The project also involves the design and manufacturing of subsystems: electron-ejecting plasma contactors, an electric control and power module, interface elements, tether and deployment mechanisms, tether tape/end-mass as well as current collection plus free-fall, and hypervelocity impact tests.
Resumo:
Ink on linen; water, drain, gas, sewer, electric light and telephone lines; residence by Marshall and Fox; signed; 117 x 43 cm.; Scale: 1"=50' [from photographic copy by Lance Burgharrdt]
Resumo:
A biography of the inventor who patented more than 1,100 inventions in 60 years, among them the electric light and the phonograph.
Resumo:
In this work it was developed mathematical resolutions taking as parameter maximum intensity values for the interference analysis of electric and magnetic fields and was given two virtual computer system that supports families of CDMA and WCDMA technologies. The first family were developed computational resources to solve electric and magnetic field calculations and power densities in Radio Base stations , with the use of CDMA technology in the 800 MHz band , taking into account the permissible values referenced by the Commission International Protection on non-Ionizing Radiation . The first family is divided into two segments of calculation carried out in virtual operation. In the first segment to compute the interference field radiated by the base station with input information such as radio channel power; Gain antenna; Radio channel number; Operating frequency; Losses in the cable; Attenuation of direction; Minimum Distance; Reflections. Said computing system allows to quickly and without the need of implementing instruments for measurements, meet the following calculated values: Effective Radiated Power; Sector Power Density; Electric field in the sector; Magnetic field in the sector; Magnetic flux density; point of maximum permissible exposure of electric field and power density. The results are shown in charts for clarity of view of power density in the industry, as well as the coverage area definition. The computer module also includes folders specifications antennas, cables and towers used in cellular telephony, the following manufacturers: RFS World, Andrew, Karthein and BRASILSAT. Many are presented "links" network access "Internet" to supplement the cable specifications, antennas, etc. . In the second segment of the first family work with more variables , seeking to perform calculations quickly and safely assisting in obtaining results of radio signal loss produced by ERB . This module displays screens representing propagation systems denominated "A" and "B". By propagating "A" are obtained radio signal attenuation calculations in areas of urban models , dense urban , suburban , and rural open . In reflection calculations are present the reflection coefficients , the standing wave ratio , return loss , the reflected power ratio , as well as the loss of the signal by mismatch impedance. With the spread " B" seek radio signal losses in the survey line and not targeted , the effective area , the power density , the received power , the coverage radius , the conversion levels and the gain conversion systems radiant . The second family of virtual computing system consists of 7 modules of which 5 are geared towards the design of WCDMA and 2 technology for calculation of telephone traffic serving CDMA and WCDMA . It includes a portfolio of radiant systems used on the site. In the virtual operation of the module 1 is compute-: distance frequency reuse, channel capacity with noise and without noise, Doppler frequency, modulation rate and channel efficiency; Module 2 includes computes the cell area, thermal noise, noise power (dB), noise figure, signal to noise ratio, bit of power (dBm); with the module 3 reaches the calculation: breakpoint, processing gain (dB) loss in the space of BTS, noise power (w), chip period and frequency reuse factor. Module 4 scales effective radiated power, sectorization gain, voice activity and load effect. The module 5 performs the calculation processing gain (Hz / bps) bit time, bit energy (Ws). Module 6 deals with the telephone traffic and scales 1: traffic volume, occupancy intensity, average time of occupancy, traffic intensity, calls completed, congestion. Module 7 deals with two telephone traffic and allows calculating call completion and not completed in HMM. Tests were performed on the mobile network performance field for the calculation of data relating to: CINP , CPI , RSRP , RSRQ , EARFCN , Drop Call , Block Call , Pilot , Data Bler , RSCP , Short Call, Long Call and Data Call ; ECIO - Short Call and Long Call , Data Call Troughput . As survey were conducted surveys of electric and magnetic field in an ERB , trying to observe the degree of exposure to non-ionizing radiation they are exposed to the general public and occupational element. The results were compared to permissible values for health endorsed by the ICNIRP and the CENELEC .
Resumo:
This paper proposes a multifunctional converter to interface renewable energy sources (e.g., solar photovoltaic panels) and electric vehicles (EVs) with the power grid in smart grids context. This multifunctional converter allows deliver energy from the solar photovoltaic panels to an EV or to the power grid, and exchange energy in bidirectional mode between the EV and the power grid. Using this multifunctional converter are not required multiple conversion stages, as occurs with the traditional solutions, where are necessary two power converters to integrate the solar photovoltaic system in the power grid and also two power converters to integrate an off-board EV battery charger in the power grid (dc-dc and dc-ac power converters in both cases). Taking into account that the energy provided (or delivered) from the power grid in each moment is function of the EV operation mode and also of the energy produced from the solar photovoltaic system, it is possible to define operation strategies and control algorithms in order to increase the energy efficiency of the global system and to improve the power quality of the electrical system. The proposed multifunctional converter allows the operation in four distinct cases: (a) Transfer of energy from the solar photovoltaic system to the power grid; (b) Transfer of energy from the solar photovoltaic system and from the EV to the power grid; (c) Transfer of energy from the solar photovoltaic system to the EV or to the power grid; (d) Transfer of energy between the EV and the power grid. Along the paper are described the system architecture and the control algorithms, and are also presented some computational simulation results for the four aforementioned cases. It is also presented a comparative analysis between the traditional and the proposed solution in terms of operation efficiency and estimated cost of implementation.
Resumo:
In the electrical industry the 50 Hz electric and magnetic fields are often higher than in the average working environment. The electric and magnetic fields can be studied by measuring or by calculatingthe fields in the environment. For example, the electric field under a 400 kV power line is 1 to 10 kV/m, and the magnetic flux density is 1 to 15 µT. Electricand magnetic fields of a power line induce a weak electric field and electric currents in the exposed body. The average current density in a human being standing under a 400 kV line is 1 to 2 mA/m2. The aim of this study is to find out thepossible effects of short term exposure to electric and magnetic fields of electricity power transmission on workers' health, in particular the cardiovascular effects. The study consists of two parts; Experiment I: influence on extrasystoles, and Experiment II: influence on heart rate. In Experiment I two groups, 26 voluntary men (Group 1) and 27 transmission-line workers (Group 2), were measured. Their electrocardiogram (ECG) was recorded with an ambulatory recorder both in and outside the field. In Group 1 the fields were 1.7 to 4.9 kV/m and 1.1 to 7.1 pT; in Group 2 they were 0.1 to 10.2 kV/m and 1.0 to 15.4 pT. In the ECG analysis the only significant observation was a decrease in the heart rate after field exposure (Group 1). The drop cannot be explained with the first measuring method. Therefore Experiment II was carried out. In Experiment II two groups were used; Group 1 (26 male volunteers) were measured in real field exposure, Group 2 (15 male volunteers) in "sham" fields. The subjects of Group 1 spent 1 h outside the field, then 1 h in the field under a 400 kV transmission line, and then again 1 h outside the field. Under the 400 kV linethe field strength varied from 3.5 to 4.3 kV/m, and from 1.4 to 6.6 pT. Group 2spent the entire test period (3 h) in a 33 kV outdoor testing station in a "sham" field. ECG, blood pressure, and electroencephalogram (EEG) were measured by ambulatory methods. Before and after the field exposure, the subjects performed some cardiovascular autonomic function tests. The analysis of the results (Experiments I and II) showed that extrasystoles or arrythmias were as frequent in the field (below 4 kV/m and 4 pT) as outside it. In Experiment II there was no decrease detected in the heart rate, and the systolic and diastolic blood pressure stayed nearly the same. No health effects were found in this study.
Resumo:
Data transmission between an electric motor and a frequency converter is required in variablespeed electric drives because of sensors installed at the motor. Sensor information can be used for various useful applications to improve the system reliability and its properties. Traditionally, the communication medium is implemented by an additional cabling. However, the costs of the traditional method may be an obstacle to the wider application of data transmission between a motor and a frequency converter. In any case, a power cable is always installed between a motor and a frequency converter for power supply, and hence it may be applied as a communication medium for sensor level data. This thesis considers power line communication (PLC) in inverter-fed motor power cables. The motor cable is studied as a communication channel in the frequency band of 100 kHz−30 MHz. The communication channel and noise characteristics are described. All the individual components included in a variable-speed electric drive are presented in detail. A channel model is developed, and it is verified by measurements. A theoretical channel information capacity analysis is carried out to estimate the opportunities of a communication medium. Suitable communication and forward error correction (FEC) methods are suggested. A general method to implement a broadband and Ethernet-based communication medium between a motor and a frequency converter is proposed. A coupling interface is also developed that allows to install the communication device safely to a three-phase inverter-fed motor power cable. Practical tests are carried out, and the results are analyzed. Possible applications for the proposed method are presented. A speed feedback motor control application is verified in detail by simulations and laboratory tests because of restrictions for the delay in the feedback loop caused by PLC. Other possible applications are discussed at a more general level.