925 resultados para Knee kinematics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Primary total knee replacement is a common operation that is performed to provide pain relief and restore functional ability. Inpatient physiotherapy is routinely provided after surgery to enhance recovery prior to hospital discharge. However, international variation exists in the provision of outpatient physiotherapy after hospital discharge. While evidence indicates that outpatient physiotherapy can improve short-term function, the longer term benefits are unknown. The aim of this randomised controlled trial is to evaluate the long-term clinical effectiveness and cost-effectiveness of a 6-week group-based outpatient physiotherapy intervention following knee replacement. Methods/design: Two hundred and fifty-six patients waiting for knee replacement because of osteoarthritis will be recruited from two orthopaedic centres. Participants randomised to the usual-care group (n = 128) will be given a booklet about exercise and referred for physiotherapy if deemed appropriate by the clinical care team. The intervention group (n = 128) will receive the same usual care and additionally be invited to attend a group-based outpatient physiotherapy class starting 6 weeks after surgery. The 1-hour class will be run on a weekly basis over 6 weeks and will involve task-orientated and individualised exercises. The primary outcome will be the Lower Extremity Functional Scale at 12 months post-operative. Secondary outcomes include: quality of life, knee pain and function, depression, anxiety and satisfaction. Data collection will be by questionnaire prior to surgery and 3, 6 and 12 months after surgery and will include a resource-use questionnaire to enable a trial-based economic evaluation. Trial participation and satisfaction with the classes will be evaluated through structured telephone interviews. The primary statistical and economic analyses will be conducted on an intention-to-treat basis with and without imputation of missing data. The primary economic result will estimate the incremental cost per quality-adjusted life year gained from this intervention from a National Health Services (NHS) and personal social services perspective. Discussion: This research aims to benefit patients and the NHS by providing evidence on the long-term effectiveness and cost-effectiveness of outpatient physiotherapy after knee replacement. If the intervention is found to be effective and cost-effective, implementation into clinical practice could lead to improvement in patients’ outcomes and improved health care resource efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Medial UKA performed in England and Wales represents 7 to 11% of all knee arthroplasty procedures, and is most commonly performed using mobile-bearing designs. Fixed bearing eliminates the risk of bearing dislocation, however some studies have shown higher revision rates for all-polyethylene tibial components compared to those that utilize metal-backed implants. The aim of the study is to analyse survivorship and maximum 8-year clinical outcome of medial fixed bearing, Uniglide unicompartmental knee arthroplasty performed using an all-polyethylene tibial component with a minimal invasive approach. Methods: Between 2002 and 2009, 270 medial fixed UKAs were performed in our unit. Patients were reviewed pre-operatively, 5 and 8 years post-operatively. Clinical and radiographic reviews were carried out. Patients’ outcome scores (Oxford, WOMAC and American Knee Score) were documented in our database and analysed. Results: Survival and clinical outcome data of 236 knees with a mean 7.3 years follow-up are reported. Every patient with less than 4.93 years follow-up underwent a revision. The patients’ average age at the time of surgery was 69.5 years. The American Knee Society Pain and Function scores, the Oxford Knee Score and the WOMAC score all improved significantly. The 5 years survival rate was 94.1% with implant revision surgery as an end point. The estimated 10 years survival rate is 91.3%. 14 patients were revised before the 5 year follow-up. Conclusion: Fixed bearing Uniglide UKA with an all-polyethylene tibial component is a valuable tool in the management of a medial compartment osteoarthritis, affording good short term survivorship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Athletic groin pain (AGP) is prevalent in sports involving repeated accelerations, decelerations, kicking and change-of-direction movements. Clinical and radiological examinations lack the ability to assess pathomechanics of AGP, but three-dimensional biomechanical movement analysis may be an important innovation. Aim: The primary aim was to describe and analyse movements used by patients with AGP during a maximum effort change-of-direction task. The secondary aim was to determine if specific anatomical diagnoses were related to a distinct movement strategy. Methods: 322 athletes with a current symptom of chronic AGP participated. Structured and standardised clinical assessments and radiological examinations were performed on all participants. Additionally, each participant performed multiple repetitions of a planned maximum effort change-of-direction task during which whole body kinematics were recorded. Kinematic and kinetic data were examined using continuous waveform analysis techniques in combination with a subgroup design that used gap statistic and hierarchical clustering. Results: Three subgroups (clusters) were identified. Kinematic and kinetic measures of the clusters differed strongly in patterns observed in thorax, pelvis, hip, knee and ankle. Cluster 1 (40%) was characterised by increased ankle eversion, external rotation and knee internal rotation and greater knee work. Cluster 2 (15%) was characterised by increased hip flexion, pelvis contralateral drop, thorax tilt and increased hip work. Cluster 3 (45%) was characterised by high ankle dorsiflexion, thorax contralateral drop, ankle work and prolonged ground contact time. No correlation was observed between movement clusters and clinically palpated location of the participant's pain. Conclusions: We identified three distinct movement strategies among athletes with long-standing groin pain during a maximum effort change-of-direction task. These movement strategies were not related to clinical assessment findings but highlighted targets for rehabilitation in response to possible propagative mechanisms. Trial registration number NCT02437942, pre results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Individuals with generalized joint hypermobility (GJH) are reported, in the clinical setting, to be at greater risk of developing musculoskeletal related joint pain, joint dislocations and tendinopathies. It is hypothesized that impaired static and dynamic neuromuscular movement control in those with GJH is responsible for contributing to an increased risk of injury and subsequent knee osteoarthritis (OA). Yet, to date, it remains unproven if there is an association between GJH and knee OA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: affecting approximately one in four adults over the age of 40 years in the UK, knee pain is the most common presenting feature of osteoarthritis (OA). Despite the plethora of studies that have investigated the factors associated with the onset of knee pain in the sedentary population, relatively little is known about the prevalence and occupational factors associated with knee pain in an athletic sporting population. This study aimed to determine in Great Britain’s (GB) Olympians, aged 40 years and older, (1) the individual factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. Methods: A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. Results: The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. Conclusions: It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only.Methods: A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made.Results: The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures.Conclusions: The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants. © 2010 Richter et al; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To determine whether a home based exercise programme can improve outcomes in patients with knee pain. Design Pragmatic, factorial randomised controlled trial of two years' duration. Setting Two general practices in Nottingham. Participants 786 men and women aged >45 years with self reported knee pain. Interventions Participants were randomised to four groups to receive exercise therapy, monthly telephone contact, exercise therapy plus telephone contact, or no intervention. Patients in the no intervention and combined exercise and telephone groups were randomised to receive or not receive a placebo health food tablet. Main outcome measures Primary outcome was self reported score for knee pain on the Western Ontario and McMaster universities (WOMAC) osteoarthritis index at two years. Secondary outcomes included knee specific physical function and stiffness (scored on WOMAC index), general physical function (scored on SF­36 questionnaire), psychological outlook (scored on hospital anxiety and depression scale), and isometric muscle strength. Results 600 (76.3%) participants completed the study. At 24 months, highly significant reductions in knee pain were apparent for the pooled exercise groups compared with the non­exercise groups (mean difference –0.82, 95% confidence interval –1.3 to –0.3). Similar improvements were observed at 6, 12, and 18 months. Regular telephone contact alone did not reduce pain. The reduction in pain was greater the closer patients adhered to the exercise plan. Conclusions A simple home based exercise programme can significantly reduce knee pain. The lack of improvement in patients who received only telephone contact suggests that improvements are not just due to psychosocial effects because of contact with the therapist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Robot-Assisted Rehabilitation (RAR) is relevant for treating patients affected by nervous system injuries (e.g., stroke and spinal cord injury) -- The accurate estimation of the joint angles of the patient limbs in RAR is critical to assess the patient improvement -- The economical prevalent method to estimate the patient posture in Exoskeleton-based RAR is to approximate the limb joint angles with the ones of the Exoskeleton -- This approximation is rough since their kinematic structures differ -- Motion capture systems (MOCAPs) can improve the estimations, at the expenses of a considerable overload of the therapy setup -- Alternatively, the Extended Inverse Kinematics Posture Estimation (EIKPE) computational method models the limb and Exoskeleton as differing parallel kinematic chains -- EIKPE has been tested with single DOFmovements of the wrist and elbow joints -- This paper presents the assessment of EIKPEwith elbow-shoulder compoundmovements (i.e., object prehension) -- Ground-truth for estimation assessment is obtained from an optical MOCAP (not intended for the treatment stage) -- The assessment shows EIKPE rendering a good numerical approximation of the actual posture during the compoundmovement execution, especially for the shoulder joint angles -- This work opens the horizon for clinical studies with patient groups, Exoskeleton models, and movements types --

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gravidez é uma fase especial da vida, com diversas alterações nos sistemas hormonais, anatómicos, e na composição corporal da mulher. No entanto, não é claro que alterações biomecânicas tridimensionais ocorrerem. Através do acompanhamento da mulher na gravidez e pós-parto, os objetivos da presente tese foram: 1) determinar os parâmetros temporais e espaciais do ciclo da marcha; 2) descrever a cinemática angular do membro inferior; 3) calcular os momentos e potências articulares do tornozelo, joelho e coxofemoral, utilizando o cálculo por dinâmica inversa; 4) descrever as magnitudes dos picos dos momentos e potências articulares dos membros inferiores; 5) identificar possíveis diferenças entre as fases de recolha relativamente aos parâmetros biomecânicos; 6) descrever longitudinalmente a composição corporal as alterações morfológicas; 7) analisar a influência das alterações antropométricas na cinética articular. Os resultados mostram que as mulheres mantêm os parâmetros temporais e espaciais da marcha. A cinemática angular do membro inferior tem o mesmo padrão, no entanto, a magnitude de alguns picos, especialmente na bacia e coxofemoral durante a fase terminal do apoio, pré-balanço e de balanço, apresentam alterações significativas. A coxofemoral é a articulação com mais alterações na cinética articular, com um aumento da carga interna associada aos momentos articulares da coxofemoral no plano transversal. No entanto, diversos momentos e potências articulares revelam uma diminuição significativa para o final da gravidez e/ou um aumento entre alguns trimestres da gravidez e o pós-parto. Como esperado, a maioria das variáveis associadas à composição corporal e às dimensões corporais tem um aumento significativo durante a gravidez e uma diminuição no pós-parto. Os modelos desenvolvidos para prever a carga interna aplicada ao membro inferior da grávida através de variáveis antropométricas, incluem quatro modelos com variáveis associadas à quantidade de gordura, quatro modelos com variáveis associadas à massa corporal global, três modelos que incluem a massa livre de gordura, e um modelo que inclui a forma do tronco. Os altos valores do R2 ajustado, mostram que as alterações na composição corporal e morfologia, determinam em grande parte a cinética articular da mulher nesta fase particular da vida.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dynamic knee valgus is a multi-planar motion that has been associated with anterior cruciate ligament injuries and patellofemoral pain syndrome. Clinical assessment of dynamic knee valgus can be made by looking for the visual appearance of excessive medial knee displacement (MKD) in the double-leg squat (DLS). The purpose of this dissertation was to identify the movement patterns and neuromuscular strategies associated with MKD during the DLS. Twenty-four control subjects and eight individuals showing MKD during the DLS participated in the study. Significant differences were verified between subjects that demonstrated MKD and a control (CON) group for the eletromyographic amplitude of adductor magnus, biceps femoris, vastus lateralis and vastus medialis muscles (p < 0.05), during the descending phase of the DLS. During the ascending phase were found group differences for adductor magnus and rectus femoris muscles (p < 0.05). Results from kinematic analysis revealed higher minimum and maximum values of ankle abduction and knee internal rotation angles (p < 0.05) for the MKD group. Also, individuals showing excessive MKD had higher hip adduction/abduction excursion. Our results suggested that higher tibial internal rotation and knee internal rotation angles in the initial position of the DLS are associated with MKD. The neuromuscular strategies that contributed to MKD were higher adductor magnus activation, whereas biceps femoris, vastus lateralis and vastus medialis activated more to stabilize the knee in response to the internal rotation moment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis studies mobile robotic manipulators, where one or more robot manipulator arms are integrated with a mobile robotic base. The base could be a wheeled or tracked vehicle, or it might be a multi-limbed locomotor. As robots are increasingly deployed in complex and unstructured environments, the need for mobile manipulation increases. Mobile robotic assistants have the potential to revolutionize human lives in a large variety of settings including home, industrial and outdoor environments.

Mobile Manipulation is the use or study of such mobile robots as they interact with physical objects in their environment. As compared to fixed base manipulators, mobile manipulators can take advantage of the base mechanism’s added degrees of freedom in the task planning and execution process. But their use also poses new problems in the analysis and control of base system stability, and the planning of coordinated base and arm motions. For mobile manipulators to be successfully and efficiently used, a thorough understanding of their kinematics, stability, and capabilities is required. Moreover, because mobile manipulators typically possess a large number of actuators, new and efficient methods to coordinate their large numbers of degrees of freedom are needed to make them practically deployable. This thesis develops new kinematic and stability analyses of mobile manipulation, and new algorithms to efficiently plan their motions.

I first develop detailed and novel descriptions of the kinematics governing the operation of multi- limbed legged robots working in the presence of gravity, and whose limbs may also be simultaneously used for manipulation. The fundamental stance constraint that arises from simple assumptions about friction and the ground contact and feasible motions is derived. Thereafter, a local relationship between joint motions and motions of the robot abdomen and reaching limbs is developed. Baseeon these relationships, one can define and analyze local kinematic qualities including limberness, wrench resistance and local dexterity. While previous researchers have noted the similarity between multi- fingered grasping and quasi-static manipulation, this thesis makes explicit connections between these two problems.

The kinematic expressions form the basis for a local motion planning problem that that determines the joint motions to achieve several simultaneous objectives while maintaining stance stability in the presence of gravity. This problem is translated into a convex quadratic program entitled the balanced priority solution, whose existence and uniqueness properties are developed. This problem is related in spirit to the classical redundancy resoxlution and task-priority approaches. With some simple modifications, this local planning and optimization problem can be extended to handle a large variety of goals and constraints that arise in mobile-manipulation. This local planning problem applies readily to other mobile bases including wheeled and articulated bases. This thesis describes the use of the local planning techniques to generate global plans, as well as for use within a feedback loop. The work in this thesis is motivated in part by many practical tasks involving the Surrogate and RoboSimian robots at NASA/JPL, and a large number of examples involving the two robots, both real and simulated, are provided.

Finally, this thesis provides an analysis of simultaneous force and motion control for multi- limbed legged robots. Starting with a classical linear stiffness relationship, an analysis of this problem for multiple point contacts is described. The local velocity planning problem is extended to include generation of forces, as well as to maintain stability using force-feedback. This thesis also provides a concise, novel definition of static stability, and proves some conditions under which it is satisfied.