1000 resultados para Invasive mole (IM)
Resumo:
The aim of this study was to analyse the infection dynamics ofAngiostrongylus cantonensisin its possible intermediate hosts over two years in an urban area in the state of Rio de Janeiro where the presence ofA. cantonensis had been previously recorded in molluscs. Four of the seven mollusc species found in the study were exotic.Bradybaena similariswas the most abundant, followed byAchatina fulica, Streptaxissp., Subulina octona, Bulimulus tenuissimus, Sarasinula linguaeformisand Leptinaria unilamellata. Only A. fulicaand B. similariswere parasitised by A. cantonensis and both presented co-infection with other helminths. The prevalence of A. cantonensisin A. fulicawas more than 50% throughout the study. There was an inverse correlation between the population size ofA. fulicaand the prevalence of A. cantonensisand abundance of the latter was negatively related to rainfall. The overall prevalence of A. cantonensisin B. similariswas 24.6%. A. fulicawas the most important intermediary host of A. cantonensisin the studied area andB. similariswas secondary in importance for A. cantonensistransmission dynamics.
Resumo:
We report the complete genome sequence and analysis of an invasive Corynebacterium diphtheriae strain that caused endocarditis in Rio de Janeiro, Brazil. It was selected for sequencing on the basis of the current relevance of nontoxigenic strains for public health. The genomic information was explored in the context of diversity, plasticity and genetic relatedness with other contemporary strains.
Resumo:
Objective This paper reviews the development and clinical validation of photodynamic diagnosis (PDD) of bladder cancer. Methods The authors reviewed the literature on the development of PDD, in particular the evidence for the clinical efficacy of hexaminolevulinate PDD in the diagnosis of bladder cancer. Results After initial work on ultraviolet cystoscopy following oral tetracycline, the focus of PDD research shifted to the use of synthetic porphyrins. First, the prodrug delta-aminolevulinic acid (ALA) was shown to cause a transient but significant accumulation of protoporphyrin IX (PpIX) in malignant or premalignant bladder tissue. Excitation by blue light leads to PpIX fluorescence (red), which distinguishes tumour from normal tissue (blue). Hexaminolevulinate (HAL, Hexvix), an ester of ALA, was then developed and has greater bioavailability and stability than the parent compound. It has been approved for clinical use in the diagnosis of bladder cancer. Clinical studies have shown that HAL PDD detects tumours, including carcinoma in situ (CIS), that are missed by conventional white-light cystoscopy. Conclusions HAL PDD is a valuable aid to the detection of bladder tumours, including CIS.
Resumo:
There is an ever-growing trend towards less-invasive procedures in all fields of medicine. We designed an animal study to prove the concept that trans-apical aortic valve replacement from an incision within the umbilicus through a single channel for instruments is feasible, which would be a major leap towards no-scar cardiac surgery. In three adult pigs, after creating a single 3-cm incision at a place where the human umbilicus would be, we introduced a 30F sheath through a tunnel created by an endoscopic vein-harvesting device up to the cardiac apex, through it and up to the left ventricle simulating the approach for trans-apical aortic valve replacement. We used a standard Amplatz nitinol occluder to seal the defect in ventricle wall later. The animals were followed up for 1h. Blood loss was minimal, and no tamponade occurred in any of the animals. In addition, we performed a test with water column static pressure to evaluate the impact of preclotting on the sealing properties of the occluders: 1 min flow-through was 2860+/-176 ml for the standard occluders and 348+/-56 ml for preclotted occluders (p<0.001).
Resumo:
Echocardiography is the preferred initial test to assess cardiac morphology and ventricular function. Cardiac MRI enables an optimal visualisation of heart muscle without contrast injection, and precise measurement of the ventricular volumes and systolic function. It is therefore an ideal test for patients with poor echocardiographic windows or for the specific evaluation of right heart chambers. Heart CT also remarkably images heart muscle and precisely measures ventricular systolic function after intravenous injection of iodinated contrast. Coronary CT may also, in selected cases, avoid the need for diagnostic coronary angiography. Although very accurate, these imaging modalities are expensive and may be contra-indicated for a particular patient. Their use in clinical practice has to follow the accepted guidelines.
Resumo:
OBJECTIVES: To document and compare the prevalence of asynchrony events during invasive-assisted mechanical ventilation in pressure support mode and in neurally adjusted ventilatory assist in children. DESIGN: Prospective, randomized, and crossover study. SETTING: Pediatric and Neonatal Intensive Care Unit, University Hospital of Geneva, Switzerland. PATIENTS: Intubated and mechanically ventilated children, between 4 weeks and 5 years old. INTERVENTIONS: Two consecutive ventilation periods (pressure support and neurally adjusted ventilatory assist) were applied in random order. During pressure support, three levels of expiratory trigger setting were compared: expiratory trigger setting as set by the clinician in charge (PSinit), followed by a 10% (in absolute values) increase and decrease of the clinician's expiratory trigger setting. The pressure support session with the least number of asynchrony events was defined as PSbest. Therefore, three periods were compared: PSinit, PSbest, and neurally adjusted ventilatory assist. Asynchrony events, trigger delay, and inspiratory time in excess were quantified for each of them. MEASUREMENTS AND MAIN RESULTS: Data from 19 children were analyzed. Main asynchrony events during PSinit were autotriggering (3.6 events/min [0.7-8.2]), ineffective efforts (1.2/min [0.6-5]), and premature cycling (3.5/min [1.3-4.9]). Their number was significantly reduced with PSbest: autotriggering 1.6/min (0.2-4.9), ineffective efforts 0.7/min (0-2.6), and premature cycling 2/min (0.1-3.1), p < 0.005 for each comparison. The median asynchrony index (total number of asynchronies/triggered and not triggered breaths ×100) was significantly different between PSinit and PSbest: 37.3% [19-47%] and 29% [24-43%], respectively, p < 0.005). With neurally adjusted ventilatory assist, all types of asynchrony events except double-triggering and inspiratory time in excess were significantly reduced resulting in an asynchrony index of 3.8% (2.4-15%) (p < 0.005 compared to PSbest). CONCLUSIONS: Asynchrony events are frequent during pressure support in children despite adjusting the cycling off criteria. Neurally adjusted ventilatory assist allowed for an almost ten-fold reduction in asynchrony events. Further studies should determine the clinical impact of these findings.
Resumo:
Objectifs : Evaluer une méthode simple et rapide de mesure du volume atrial gauche. Matériels et méthodes : Cinquante patients ont été examinés avec un CT gaté pour mesure du score calcique. Trois méthodes ont été utilisées pour calculer le volume atrial gauche : 1) une méthode orthogonale avec mesure des surfaces/diamètres dans les plans axiaux/coronaux/sagittaux, 2) une méthode biplan inspirée de l'échocardiographie et 3) une méthode volumétrique. Les mesures ont été faites par le même observateur un mois plus tard et ont été répétées par trois autres observateurs. L'axe cardiaque a aussi été mesuré. La méthode Bland-Altmann et les corrélations de Spearman ont été utilisées. Résultats : La méthode volumétrique montre les variations intra/interobservateur les plus basses avec une variabilité de 6,1/7,4 ml, respectivement. Pour les mesures avec la méthode orthogonale (surfaces/diamètres), les variations intra/interobservateur sont 12,3/13,5 ml et 14,6/11,6 ml, respectivement. Pour la méthode biplan, les variations intra/interobservateur sont plus hautes : 23,9/19,8 ml. Comparée à la méthode de référence volumétrique, la méthode orthogonale avec les surfaces est mieux corrélée (R=0,959, p<0,001) que les autres méthodes. Il y a une faible influence de l'axe du coeur sur la méthode orthogonale avec les surfaces. Conclusion : La méthode volumétrique est le gold standard en terme de variabilité. Cependant elle est longue à metttre en oeuvre. La méthode orthogonale avec les surfaces est une alternative simple, sauf chez les patients obèses avec un coeur horizontalisé.