850 resultados para Internal customers
Resumo:
We have investigated the presence of the aerobactin system and the location of the aerobactin genes in enteroinvasive strains of Escherichia coli. Also, we cloned the aerobactin region and its flanking sequences from the chromosome of a strain of Shigella flexneri and compared the molecular organization of the aerobactin genes in the two genera. Of the 11 enteroinvasive E. coli strains studied, 5 possessed the aerobactin genes, which were located on the chromosome in each case. These strains produced and utilized aerobactin and also were susceptible to the bacteriocin cloacin-DF13. Restriction endonuclease mapping and hybridization experiments showed that the regions corresponding to the aerobactin-specific sequences were very similar in both enteroinvasive E. coli and S. flexneri. However, differences were found in the region corresponding to the aerobactin receptor gene. The regions flanking the aerobactin system in enteroinvasive E. coli and S. flexneri exhibited some similarities but were different from those in pColV-K30. Under iron-limiting conditions, aerobactin-producing enteroinvasive E. coli and S. flexneri synthesized outer-membrane proteins of 76 and 77 kDa, respectively, which cross-reacted immunologically with rabbit antiserum raised against the 74 kDa pColV-K30-encoded ferric aerobactin receptor.
Resumo:
The artefact was published in the following :
Bennett, D., (October 2007), Architectural Insitu Concrete, RIBA Publishing, London, , ISBN 124-3671-245, pp 101-103
Bennett, D., (2008), Concrete Elegance Four, London, Concrete Centre and RIBA Publishing, pp cover, c, 4, 9-12 & back.
Stacey, Professor M., (2011) Concrete: a studio design guide, London, Concrete Centre and RIBA Publishing, pp74-75.
Resumo:
In the space of just 20 years, internal cross-border co-operation (CBC) has transformed from a marginal issue for European integration into an important strand of the third objective of European Union's (EU's) regional policy. How might this process of transformation be explained? This study intends to reconstruct the chronology of its development through interviews and use of archival material. The emergence of the current CBC policy was not, we argue, an inevitable solution to the problem of border management but, rather, the result of a struggle between the actors of that policy sub-system. The dramatic rise of CBC is the result of a series of factors that originated with the signing of the Single European Act in 1986. The construction of CBC as a set of problems and solutions by a network of policy actors at the margins of the EU through a series of technical reports, together with the policy window opened by the appointment of the Delors Commission, allowed the launching of an innovative CBC policy which has consolidated over time.
Resumo:
Energy release from radioactive decays contributes significantly to supernova light curves. Previous works, which considered the energy deposited by ?-rays and positrons produced by Ni, Co, Ni, Co, Ti and Sc, have been quite successful in explaining the light curves of both core collapse and thermonuclear supernovae. We point out that Auger and internal conversion electrons, together with the associated X-ray cascade, constitute an additional heat source. When a supernova is transparent to ?-rays, these electrons can contribute significantly to light curves for reasonable nucleosynthetic yields. In particular, the electrons emitted in the decay of Co, which are largely due to internal conversion from a fortuitously low-lying 3/2 state in the daughter Fe, constitute an additional significant energy-deposition channel. We show that when the heating by these electrons is accounted for, a slow-down in the light curve of SN 1998bw is naturally obtained for typical hypernova nucleosynthetic yields. Additionally, we show that for generic Type Ia supernova yields, the Auger electrons emitted in the ground-state to ground-state electron capture decay of Fe exceed the energy released by the Ti decay chain for many years after the explosion. © 2009 RAS.
Resumo:
Background: A full-thickness macular hole (FTMH) is a common retinal condition associated with impaired vision. Randomised controlled trials (RCTs) have demonstrated that surgery, by means of pars plana vitrectomy and post-operative intraocular tamponade with gas, is effective for stage 2, 3 and 4 FTMH. Internal limiting membrane (ILM) peeling has been introduced as an additional surgical manoeuvre to increase the success of the surgery; i.e. increase rates of hole closure and visual improvement. However, little robust evidence exists supporting the superiority of ILM peeling compared with no-peeling techniques. The purpose of FILMS (Full-thickness macular hole and Internal Limiting Membrane peeling Study) is to determine whether ILM peeling improves the visual function, the anatomical closure of FTMH, and the quality of life of patients affected by this disorder, and the cost-effectiveness of the surgery. Methods/Design: Patients with stage 2-3 idiopathic FTMH of less or equal than 18 months duration (based on symptoms reported by the participant) and with a visual acuity = 20/40 in the study eye will be enrolled in this FILMS from eight sites across the UK and Ireland. Participants will be randomised to receive combined cataract surgery (phacoemulsification and intraocular lens implantation) and pars plana vitrectomy with postoperative intraocular tamponade with gas, with or without ILM peeling. The primary outcome is distance visual acuity at 6 months. Secondary outcomes include distance visual acuity at 3 and 24 months, near visual acuity at 3, 6, and 24 months, contrast sensitivity at 6 months, reading speed at 6 months, anatomical closure of the macular hole at each time point (1, 3, 6, and 24 months), health related quality of life (HRQOL) at six months, costs to the health service and the participant, incremental costs per quality adjusted life year (QALY) and adverse events. Discussion: FILMS will provide high quality evidence onthe role of ILM peeling in FTMH surgery. © 2008 Lois et al; licensee BioMed Central Ltd.
Resumo:
PURPOSE. To determine whether internal limiting membrane (ILM) peeling is effective and cost effective compared with no peeling in patients with idiopathic stage 2 or 3 full-thickness maculay hole (FTMH). METHODS. This was a pragmatic multicenter randomized controlled trial. Eligible participants from nine centers were randomized to ILM peeling or no peeling (1:1 ratio) in addition to phacovitrectomy, including detachment and removal of the posterior hyaloid and gas tamponade. The primary outcome was distance visual acuity (VA) at 6 months after surgery. Secondary outcomes included hole closure, distance VA at other time points, near VA, contrast sensitivity, reading speed, reoperations, complications, resource use, and participant-reported health status, visual function, and costs. RESULTS. Of 141 participants randomized in nine centers, 127 (90%) completed the 6-month follow-up. Nonstatistically significant differences in distance visual acuity at 6 months were found between groups (mean difference, 4.8; 95% confidence interval [CI], -0.3 to 9.8; P = 0.063). There was a significantly higher rate of hole closure in the ILM-peel group (56 [84%] vs. 31 [48%]) at 1 month (odds ratio [OR], 6.23; 95% CI, 2.64-14.73; P <0.001) with fewer reoperations (8 [12%] vs. 31 [48%]) performed by 6 months (OR, 0.14; 95% CI, 0.05- 0.34; P <0.001). Peeling the ILM is likely to be cost effective. CONCLUSIONS. There was no evidence of a difference in distance VA after the ILM peeling and no-ILM peeling techniques. An important benefit in favor of no ILM peeling was ruled out. Given the higher anatomic closure and lower reoperation rates in the ILM-peel group, ILM peeling seems to be the treatment of choice for idiopathic stage 2 to 3 FTMH. © 2011 The Association for Research in Vision and Ophthalmology, Inc.
Resumo:
Aim: To determine whether internal limiting membrane (ILM) peeling is cost-effective compared with no peeling for patients with an idiopathic stage 2 or 3 full-thickness macular hole. Methods: A cost-effectiveness analysis was performed alongside a randomised controlled trial. 141 participants were randomly allocated to receive macular-hole surgery, with either ILM peeling or no peeling. Health-service resource use, costs and quality of life were calculated for each participant. The incremental cost per quality-adjusted life year (QALY) gained was calculated at 6 months. Results: At 6 months, the total costs were on average higher (£424, 95% CI -182 to 1045) in the No Peel arm, primarily owing to the higher reoperation rate in the No Peel arm. The mean additional QALYs from ILM peel at 6 months were 0.002 (95% CI 0.01 to 0.013), adjusting for baseline EQ-5D and other minimisation factors. A mean incremental cost per QALY was not computed, as Peeling was on average less costly and slightly more effective. A stochastic analysis suggested that there was more than a 90% probability that Peeling would be cost-effective at a willingness-to-pay threshold of £20 000 per QALY. Conclusion: Although there is no evidence of a statistically significant difference in either costs or QALYs between macular hole surgery with or without ILM peeling, the balance of probabilities is that ILM Peeling is likely to be a cost-effective option for the treatment of macular holes. Further long-term follow-up data are needed to confirm these findings.
Resumo:
Peeling the internal limiting membrane of the retina has become a very common procedure performed by vitreo-retinal surgeons. The combination of new microsurgical instrumentation with the availability of different dyes to stain this thin and transparent membrane has facilitated the performance of internal limiting membrane peeling, reducing the time and trauma associated with this maneuver. Internal limiting membrane peeling has been used to treat a variety of retinal pathologies, including full-thickness macular hole, epiretinal membrane, macular edema, vitreomacular traction syndrome, and Terson syndrome, among others. Although it appears that peeling the internal limiting membrane in these retinal conditions may be associated with better anatomical and visual outcomes following surgery, further evidence through randomized controlled clinical trials is still needed to guide the vitreo-retinal surgeon on the appropriate use of this surgical maneuver. © 2008 Elsevier Inc. All rights reserved.
Resumo:
PURPOSE: To report the use of perfluorohexyloctane, a liquid semifluorinated alkane that is heavier than water, as an internal tamponade agent in surgery for complicated retinal detachments. DESIGN: A consecutive interventional case series from three study centers. METHODS: In 23 consecutive eyes (23 patients, 19 men and four women, mean ± standard deviation (SD) age of 58.5 years ± 16.1) perfluorohexyloctane was used for long-term internal tamponade. Included were eyes with complicated retinal detachment involving the lower two quadrants of the fundus. Excluded were patients with diseases in the fellow eye or severe systemic disease. A pars plana vitrectomy was performed, including membrane peeling and retinotomy where necessary. RESULTS: The mean duration for perfluorohexyloctane being left in situ was 76 days (SD 37.64) (range, 35-202 days). Four weeks following the removal of perfluorohexyloctane 19 of the 23 patients had total reattachment of the retina; three eyes had a recurrence of retinal detachment. One patient was lost to follow-up. The mean follow-up after perfluorohexyloctane removal was 97 days (range, 48 to 169 days). Cataract formation or progression was noted in nine of the 10 eyes. There were two cases with high intraocular pressures. Dispersion into small droplets was observed as early as 3 days postoperatively in three of the 23 patients. At least 12 of the 23 patients had an obvious dispersion by the time of perfluorohexyloctane removal. There was no sign of optic atrophy, retinal necrosis, or retinal vascular occlusion. CONCLUSION: Perfluorohexyloctane was tolerated as a long-term internal tamponade agent without obvious signs of damage to the retina or optic disk. Of all the complications noted, the most common was that of dispersion of the perfluorohexyloctane bubble into droplets. © 2002 by Elsevier Science Inc. All rights reserved.
Resumo:
The adoption of each new level of automotive emissions legislation often requires the introduction of additional emissions reduction techniques or the development of existing emissions control systems. This, in turn, usually requires the implementation of new sensors and hardware which must subsequently be monitored by the on-board fault detection systems. The reliable detection and diagnosis of faults in these systems or sensors, which result in the tailpipe emissions rising above the progressively lower failure thresholds, provides enormous challenges for OBD engineers. This paper gives a review of the field of fault detection and diagnostics as used in the automotive industry. Previous work is discussed and particular emphasis is placed on the various strategies and techniques employed. Methodologies such as state estimation, parity equations and parameter estimation are explained with their application within a physical model diagnostic structure. The utilization of symptoms and residuals in the diagnostic process is also discussed. These traditional physical model based diagnostics are investigated in terms of their limitations. The requirements from the OBD legislation are also addressed. Additionally, novel diagnostic techniques, such as principal component analysis (PCA) are also presented as a potential method of achieving the monitoring requirements of current and future OBD legislation.