977 resultados para Individual Variability
Resumo:
The combined use of precision agriculture and the Diagnosis and Recommendation Integrated System (DRIS) allows the spatial monitoring of coffee nutrient balance to provide more balanced and cost-effective fertilizer recommendations. The objective of this work was to evaluate the spatial variability in the nutritional status of two coffee varieties using the Mean Nutritional Balance Index (NBIm) and its relationship with their respective yields. The experiment was conducted in eastern Minas Gerais in two areas, one planted with variety Catucaí and another with variety Catuaí. The NBIm of the two varieties and their yields were analyzed through geostatistics and, based on the models and parameters of the variograms, were interpolated to obtain their spatial distribution in the studied areas. Variety Catucai, with grater spatial variability, was more nutritional unbalanced than variety Catuai, and consequently produced lower yields. Excess of Fe and Mn makes these elements limiting yield factors.
Resumo:
Information on the spatial distribution of particle size fractions is essential for use planning and management of soils. The aim of this work to was to study the spatial variability of particle size fractions of a Typic Hapludox cultivated with conilon coffee. The soil samples were collected at depths of 0-0.20 and 0.20-0.40 m in the coffee canopy projection, totaling 109 georeferentiated points. At the depth of 0.2-0.4 m the clay fraction showed average value significantly higher, while the sand fraction showed was higher in the depth of 0-0.20 m. The silt showed no significant difference between the two depths. The particle size fractions showed medium and high spatial variability. The levels of total sand and clay have positive and negative correlation, respectively, with the altitude of the sampling points, indicating the influence of landscape configuration.
Resumo:
O objetivo deste estudo foi desenvolver um método para identificar efeitos de treinamento nos desempenhos dos indivíduos e da organização, combinação ainda rara na literatura científica. Foi realizado no Banco do Brasil, com 218 profissionais que fizeram um MBA em Marketing. Os dados foram coletados por meio de entrevistas e questionários de auto e heteroavaliação. Nos questionários foi avaliada a contribuição do treinamento para a melhoria do desempenho individual e organizacional, e o suporte à transferência de treinamento. Nas entrevistas foram levantados indicadores de melhoria do desempenho organizacional para os maiores impactos percebidos pelos respondentes. Os resultados indicam que, para a maioria dos desempenhos individuais e organizacionais, o impacto percebido do treinamento foi avaliado entre bom e ótimo. A metodologia utilizada foi considerada adequada para a identificação de melhorias nos desempenhos organizacionais, percebidos como os mais afetados pelo treinamento. Também foram discutidas implicações metodológicas, teóricas e perspectivas futuras.
Resumo:
O presente artigo investiga o comportamento de gestores públicos, identificando os fatores críticos que determinam o processo decisório de compra sustentável, seja no contexto de compras individuais (ou domésticas) ou no contexto de compras organizacionais (nesse caso, refere-se às compras públicas sustentáveis, conceito recentemente inserido na legislação brasileira). Em seguida à aplicação de questionários a um grupo de gestores públicos encarregados da elaboração de editais e condução de certames licitatórios, foram realizadas inferências estatísticas que determinaram as similitudes entre os dois contextos. A partir dos resultados, observou-se diferenças relacionadas com o contexto de compra envolvido, em especial naquelas que envolvem preço, determinações da legislação e tempo gasto nas especificações dos produtos a serem adquiridos. Chamam atenção, ademais, o fato de que alguns padrões pró-ambientais se mostram bem estabelecidos, evidenciado o resultado de campanhas desenvolvidas no âmbito da instituição.
Resumo:
Se analizan los factores que interfieren en la esterilidad inducida químicamente en R. Prolixus mediante aplicaciones tópicas en distintas dosis de metepa. Se sugiere profundizar el estudio de la susceptibilidad individual para conocer la composición de la población frente al quimioesterilizante y la probable aparición de resistencia. Se investiga además la acción del metepa sobre T. cruzi en triatominos infectados experimentalmente, obteniéndose resultados negativos.
Resumo:
A aplicação das radiações ionizantes na área da medicina tem vindo a crescer desde o século passado. Na área da medicina, existem três especialidades principais que desenvolvem as suas actividades recorrendo à aplicação de radiações ionizantes, no âmbito do diagnóstico e da terapêutica: a Medicina Nuclear, a Radiologia e a Radioterapia. Salienta-se uma quarta área, a Cardiopneumologia quando actua na cardiologia de intervenção. Segundo o Decreto-Lei nº 222/2008, de 17/11, cabe às Organizações de Saúde (OSs) a responsabilidade de assegurar a monitorização individual dos trabalhadores expostos a radiações ionizantes, a monitorização dos locais de trabalho e a vigilância médica dos trabalhadores expostos. No que respeita à monitorização individual dos profissionais, as OSs determinam qual e empresa que procederá ao fornecimento e leitura dos dosímetros, não esquecendo no momento da contratação o Decreto-Lei nº 222/2008, de 17/11, artigo 10, que salienta que a monitorização individual dos trabalhadores da categoria A deve ter uma periodicidade mensal, assim como as leituras de dosimetria individual também devem ser mensais. Todos os profissionais têm o direito de aceder a todos os dados referentes à sua monitorização individual das doses de radiação, incluindo os resultados das medições, individuais ou de área que levaram à estimação das doses recebidas. O objectivo geral deste estudo é verificar se as OSs notificam/informam os profissionais de saúde expostos a radiações ionizantes das leituras de dosimetria individual e com que periodicidade.
Resumo:
A complexidade do objeto epidemiológico tem suscitado, ao longo do tempo, discussão sobre alguns elementos que o compõem, assumindo, muitas vezes, a forma de antinomias. Utilizando-se como substrato textos fundamentais, analisaram-se, no âmbito da epidemiologia social, a formulação e a proposta de solução para as antinomias biológico-social e individual-coletivo. Criticou-se a validade teórica das saídas apontadas pelo discurso epidemiológico-social para resolver o "conflito de leis" que permeia o referido objeto. Destacou-se o conceito marxista-helleriano de indivíduo para contribuir com a "sutura" dos três planos da realidade: o universal, o particular e o singular.
Resumo:
The aim of this paper is to establish some basic guidelines to help draft the information letter sent to individual contributors should it be decided to use this model in the Spanish public pension system. With this end in mind and basing our work on the experiences of the most advanced countries in the field and the pioneering papers by Jackson (2005), Larsson et al. (2008) and Sunden (2009), we look into the concept of “individual pension information” and identify its most relevant characteristics. We then give a detailed description of two models, those in the United States and Sweden, and in particular look at how they are structured, what aspects could be improved and what their limitations are. Finally we make some recommendations of special interest for designing the model for Spain.
Resumo:
Introdução – A monitorização da exposição ocupacional a doses de radiação ionizante pode ser complementada por dosímetros eletrónicos individuais que permitem uma leitura direta da dose de radiação recebida. Dada a dependência energética e de débito de dose já reportada para estes dosímetros, este trabalho pretende determinar a linearidade da resposta de um dosímetro eletrónico individual e estudar o comportamento da sua resposta em função da energia de radiação e do débito de dose. Metodologia – Para estudar a dependência da energia da radiação do dosímetro eletrónico pessoal Vertec Bleeper Sv procedeu‑se à sua irradiação com um equivalente de dose individual, Hp(10), de 500 μSv de radiação gama do Cobalto – 60 (60C) e Césio – 137 (137Cs) e das qualidades de radiação X da série Narrow (N): N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. Para investigar a dependência da resposta em função do débito de dose aplicaram‑se à ampola de raios X as intensidades de corrente elétrica de 1 mA, 5 mA, 10 mA, 15 mA e 20 mA. Resultados – Não existe uma relação entre a resposta do detetor e a energia de radiação a que este é exposto. Ocorre uma subestimação superior a 50% na grandeza medida para energias inferiores a 33 keV, mas ostenta uma medida relativamente linear da grandeza Hp(10) para doses inferiores a 100 μSv. Também se constata que, à medida que o débito de dose aumenta, existe uma diminuição na resposta do dosímetro. O menor decréscimo na resposta deste dosímetro eletrónico individual dá‑se para as qualidades de radiação N‑30 (1,1%), N‑40 (4,1%) e N‑120 (20,0%). Conclusão – Verifica‑se que a resposta do dosímetro individual Vertec Bleeper Sv depende fortemente da energia da radiação e do débito de dose. ABSTRACT: Introduction – The measurement of occupational exposure to radiation doses can be completed with an electronic personal dosemeter that allows a direct reading and alarm function of the received radiation dose. Due to the energy and dose rate dependence already reported for this type of dosemeter, it is intended, with this work, to determine the response linearity of an Electronic Personal Dosemeter and to study its response behavior to the dose rate and radiation energy. Methodology – The electronic personal dosemeter Vertec Bleeper Sv energy dependency was evaluated by its irradiation with 500 μSv from the radionuclides Cobalt – 60 (60C) and Cesium – 137 (137Cs) as well as by the radiation qualities of the Narrow (N) series: N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. To investigate the dose rate dependency, the intensities of electric current of 1 mA, 5 mA, 10 mA, 15 mA and 20 mA were applied to the X‑ray tube. Results – There is no relationship between the response of the detector and the radiation energy. For energies below 33 keV there is an underestimation over 50% of the radiation dose measured but the detector presents a linear response for energies under 100 μSv. A dependency on the dose rate is perceived since as the dose rate increases, the response of the individual monitor decreases. There is a smaller decrease for the radiation qualities of N‑30 (1.1%), N‑40 (4.1%) and N‑120 (20.0%). Conclusion – It is concluded that there is a strong dependence of radiation energy and dose rate on the response of an electronic personal dosemeter.
Resumo:
Conferência anual da ISME
Resumo:
Dissertação de Mestrado, Estudos Integrados dos Oceanos, 20 de Março de 2014, Universidade dos Açores.
Resumo:
World Congress of Malacology, Universidade dos Açores, Ponta Delgada, 21-28 de julho.
Resumo:
The present paper reports the amount and estimated daily mineral intake of nine elements (Ca, Mg, K, Na, P, Fe, Mn, Cr and Ni) in commercial instant coffees and coffee substitutes (n = 49). Elements were quantified by high-resolution continuum source flame (HR-CS-FAAS) and graphite furnace (HR-CS-GFAAS) atomic absorption spectrometry, while phosphorous was evaluated by a standard vanadomolybdophosphoric acid colorimetric method. Instant coffees and coffee substitutes are rich in K, Mg and P (>100 mg/100 g dw), contain Na, Ca and Fe in moderate amounts (>1 mg/100 g), and trace levels of Cr and Ni. Among the samples analysed, plain instant coffees are richer in minerals (p < 0.001), except for Na and Cr. Blends of coffee substitutes (barley, malt, chicory and rye) with coffee (20–66%) present intermediate amounts, while lower quantities are found in substitutes without coffee, particularly in barley. From a nutritional point of view the results indicate that the mean ingestion of two instant beverages per day (total of 4 g instant powder), either with or without coffee, cannot be regarded as important sources of minerals to the human diet, although providing a supplementation of some minerals, particularly Mg and Mn in instant coffees. Additionally, and for authentication purposes, the correlations observed between some elements and the coffee percentage in the blends, with particular significance for Mg amounts, provides a potential tool for the estimation of coffee in substitute blends.
Resumo:
In this work, a microwave-assisted extraction (MAE) methodology was compared with several conventional extraction methods (Soxhlet, Bligh & Dyer, modified Bligh & Dyer, Folch, modified Folch, Hara & Radin, Roese-Gottlieb) for quantification of total lipid content of three fish species: horse mackerel (Trachurus trachurus), chub mackerel (Scomber japonicus), and sardine (Sardina pilchardus). The influence of species, extraction method and frozen storage time (varying from fresh to 9 months of freezing) on total lipid content was analysed in detail. The efficiencies of methods MAE, Bligh & Dyer, Folch, modified Folch and Hara & Radin were the highest and although they were not statistically different, differences existed in terms of variability, with MAE showing the highest repeatability (CV = 0.034). Roese-Gottlieb, Soxhlet, and modified Bligh & Dyer methods were very poor in terms of efficiency as well as repeatability (CV between 0.13 and 0.18).