888 resultados para Filters and filtration
Resumo:
The suitability of a new plastic supporting medium for biofiltration was tested over a three year period. Tests were carried out on the stability, surface properties, mechanical strength, and dimensions of the medium. There was no evidence to suggest that the medium was deficient in any of these respects. The specific surface (320m2m-3) and the voidage (94%) of the new medium are unlike any other used in bio-filtration and a pilot plant containing two filters was built to observe its effects on ecology and performance. Performance was estimated by chemical analysis and ecology studied by film examination and fauna counts. A system of removable sampling baskets was designed to enable samples to be obtained from two intermediate depths of filter. One of the major operating problems of percolating filters is excessive accumulation of film. The amount of film is influenced by hydraulic and organic load and each filter was run at a different loading. One was operated at 1.2m3m-3day-1 (DOD load 0.24kgm-3day-1) judged at the time to be the lowest filtration rate to offer advantages over conventional media. The other filter was operated at more than twice this loading (2.4m3m-3day-lBOD load 0.55kgm-3day-1) giving a roughly 2.5x and 6x the conventional loadings recommended for a Royal Commission effluent. The amount of film in each filter was normally low (0.05-3kgm(3 as volatile solids) and did not affect efficiency. The evidence collected during the study indicated that the ecology of the filters was normal when compared with the data obtained from the literature relating to filters with mineral media. There were indications that full ecological stability was yet to be reached and this was affecting the efficiency of the filters. The lower rate filter produced an average 87% BOD removal giving a consistent Royal Commission effluent during the summer months. The higher rate filter produced a mean 83% BOD removal but at no stage a consistent Royal Commission effluent. From the data on ecology and performance the filters resembled conventional filters rather than high rate filters.
Resumo:
Masking, adaptation, and summation paradigms have been used to investigate the characteristics of early spatio-temporal vision. Each has been taken to provide evidence for (i) oriented and (ii) nonoriented spatial-filtering mechanisms. However, subsequent findings suggest that the evidence for nonoriented mechanisms has been misinterpreted: those experiments might have revealed the characteristics of suppression (eg, gain control), not excitation, or merely the isotropic subunits of the oriented detecting mechanisms. To shed light on this, we used all three paradigms to focus on the ‘high-speed’ corner of spatio-temporal vision (low spatial frequency, high temporal frequency), where cross-oriented achromatic effects are greatest. We used flickering Gabor patches as targets and a 2IFC procedure for monocular, binocular, and dichoptic stimulus presentations. To account for our results, we devised a simple model involving an isotropic monocular filter-stage feeding orientation-tuned binocular filters. Both filter stages are adaptable, and their outputs are available to the decision stage following nonlinear contrast transduction. However, the monocular isotropic filters (i) adapt only to high-speed stimuli—consistent with a magnocellular subcortical substrate—and (ii) benefit decision making only for high-speed stimuli (ie, isotropic monocular outputs are available only for high-speed stimuli). According to this model, the visual processes revealed by masking, adaptation, and summation are related but not identical.
Resumo:
Background Yellow filters are sometimes recommended to people with low vision. Our aim was investigate the effects of three commercial yellow filters on visual acuity and contrast sensitivity (with and without glare) and reading (without glare) under conditions of forward light scatter (FLS). Method Fifty-five healthy subjects were assessed with Corning Photochromic Filters (CPFs) 450, 511 and 527 and a filter producing FLS. The effects on log MAR visual acuity, Pelli–Robson contrast sensitivity with and without glare, and reading (measured with MNRead charts) without glare were determined. Results Statistically significant differences were found between the overall effect of glare and between CPFs for visual acuity and contrast sensitivity. A gradual decline in visual acuity, contrast sensitivity and reading with increasing CPF absorption was noted. Conclusion Effects of CPF450, 511, 527 on visual acuity, contrast sensitivity and reading under conditions of FLS were negative but not clinically significant.
Resumo:
Background: The aim was to investigate the visual effect of coloured filters compared to transmission-matched neutral density filters, in patients with dry age-related macular degeneration. Methods: Visual acuity (VA, logMAR), contrast sensitivity (Pelli-Robson) and colour vision (D15) were recorded for 39 patients (average age 79.1 ± 7.2 years) with age-related macular degeneration, both in the presence and absence of glare from a fluorescent source. Patients then chose their preferred coloured and matched neutral density transmission filters (NoIR). Visual function tests were repeated with the chosen filters, both in the presence and absence of glare from the fluorescent source. Patients trialled the two filters for two weeks each, in random order. Following the trial of each filter, a telephone questionnaire was completed. Results: VA and contrast sensitivity were unaffected by the coloured filters but reduced through the neutral density filters (p < 0.01). VA and contrast sensitivity were reduced by similar amounts, following the introduction of the glare source, both in the presence and absence of filters (p < 0.001). Colour vision error scores were increased following the introduction of a neutral density filter (from 177.6 ± 60.2 to 251.9 ± 115.2) and still further through coloured filters (275.1 ± 50.8; p < 0.001). In the absence of any filter, colour vision error scores increased by 29.1 ± 55.60 units in the presence of glare (F2,107 = 3.9, p = 0.02); however, there was little change in colour vision error scores, in the presence of glare, with either the neutral density or coloured filters. Questionnaires indicated that patients tended to gain more benefit from the coloured filters. Conclusions: Coloured filters had minimal impact on VA and contrast sensitivity in patients with age-related macular degeneration; however, they caused a small reduction in objective colour vision, although this was not registered subjectively by patients. Patients indicated that they received more benefit from the coloured filters compared with neutral density filters. © 2013 The Authors © 2013 Optometrists Association Australia.
Resumo:
Purpose - The aim of the study was to determine the effect of optimal spectral filters on reading performance following stroke. Methods - Seventeen stroke subjects, aged 43-85, were considered with an age-matched Control Group (n = 17). Subjects undertook the Wilkins Rate of Reading Test on three occasions: (i) using an optimally selected spectral filter; (ii) subjects were randomly assigned to two groups: Group 1 used an optimal filter, whereas Group 2 used a grey filter, for two-weeks. The grey filter had similar photopic reflectance to the optimal filters, intended as a surrogate for a placebo; (iii) the groups were crossed over with Group 1 using a grey filter and Group 2 given an optimal filter, for two weeks, before undertaking the task once more. An increase in reading speed of >5% was considered clinically relevant. Results - Initial use of a spectral filter in the stroke cohort, increased reading speed by ~8%, almost halving error scores, findings not replicated in controls. Prolonged use of an optimal spectral filter increased reading speed by >9% for stroke subjects; errors more than halved. When the same subjects switched to using a grey filter, reading speed reduced by ~4%. A second group of stroke subjects used a grey filter first; reading speed decreased by ~3% but increased by ~4% with an optimal filter, with error scores almost halving. Conclusions - The present study has shown that spectral filters can immediately improve reading speed and accuracy following stroke, whereas prolonged use does not increase these benefits significantly. © 2013 Spanish General Council of Optometry.
Resumo:
Series Micro-Electro-Mechanical System (MEMS) switches based on superconductor are utilized to switch between two bandpass hairpin filters with bandwidths of 365 MHz and nominal center frequencies of 2.1 GHz and 2.6 GHz. This was accomplished with 4 switches actuated in pairs, one pair at a time. When one pair was actuated the first bandpass filter was coupled to the input and output ports. When the other pair was actuated the second bandpass filter was coupled to the input and output ports. The device is made of a YBa2Cu 3O7 thin film deposited on a 20 mm x 20 mm LaAlO3 substrate by pulsed laser deposition. BaTiO3 deposited by RF magnetron sputtering in utilized as the insulation layer at the switching points of contact. These results obtained assured great performance showing a switchable device at 68 V with temperature of 40 K for the 2.1 GHz filter and 75 V with temperature of 30 K for the 2.6 GHz hairpin filter. ^
Resumo:
A liquid chromatography/mass spectrometry (LC/MS, electrospray ionisation) method has been developed for the quantification of nitrogenous osmolytes (N-osmolytes) in the particulate fraction of natural water samples. Full method validation demonstrates the validity of the method for measuring glycine betaine (GBT), choline and trimethylamine N-oxide (TMAO) in particulates from seawater. Limits of detection were calculated as 3.5, 1.2 and 5.9 pg injected onto column (equivalent to 1.5, 0.6 and 3.9 nmol per litre) for GBT, choline and TMAO respectively. Precision of the method was typically 3% for both GBT and choline and 6% for TMAO. Collection of the particulate fraction of natural samples was achieved via in-line filtration. Resulting chromatography and method sensitivity was assessed and compared for the use of both glass fibre and polycarbonate filters during sample collection. Ion suppression was shown to be a significant cause of reduced instrument response to N-osmolytes and was associated with the presence of seawater in the sample matrix
Resumo:
A liquid chromatography/mass spectrometry (LC/MS, electrospray ionisation) method has been developed for the quantification of nitrogenous osmolytes (N-osmolytes) in the particulate fraction of natural water samples. Full method validation demonstrates the validity of the method for measuring glycine betaine (GBT), choline and trimethylamine N-oxide (TMAO) in particulates from seawater. Limits of detection were calculated as 3.5, 1.2 and 5.9 pg injected onto column (equivalent to 1.5, 0.6 and 3.9 nmol per litre) for GBT, choline and TMAO respectively. Precision of the method was typically 3% for both GBT and choline and 6% for TMAO. Collection of the particulate fraction of natural samples was achieved via in-line filtration. Resulting chromatography and method sensitivity was assessed and compared for the use of both glass fibre and polycarbonate filters during sample collection. Ion suppression was shown to be a significant cause of reduced instrument response to N-osmolytes and was associated with the presence of seawater in the sample matrix
Resumo:
Therapeutic plasmapheresis allows the extracorporeal removal of plasmatic lipoproteins (Lipid-apheresis) (LA). It can be non selective (non specific), semi - selective or selective low density lipoprotein-lipoprotein(a) (specific [LDL- Lp(a)] apheresis) (Lipoprotein apheresis, LDLa). The LDL removal rate is a perfect parameter to assess the system efficiency. Plasma-Exchange (PEX) cannot be considered either specific nor, selective. In PEX the whole blood is separated into plasma and its corpuscular components usually through centrifugation or rather filtration. The corpuscular components mixed with albumin solution plus saline (NaCl 0.9%) solution at 20%-25%, are then reinfused to the patient, to substitute the plasma formerly removed. PEX eliminates atherogenic lipoproteins, but also other essential plasma proteins, such as albumin, immunoglobulins, and hemocoagulatory mediators. Cascade filtration (CF) is a method based on plasma separation and removal of plasma proteins through double filtration. During the CF two hollow–fiber filters with pores of different diameter are used to eliminate the plasma components of different weight and molecular diameter. A CF system uses a first polypropylene filter with 0.55 µm diameter pores and a second one of diacetate of cellulose with 0.02 µm pores. The first filter separates the whole blood, and the plasma is then perfused through a second filter which allows the recovery of molecules with a diameter lower than 0.02 µm, and the removal of molecules larger in diameter as apoB100–containing lipoproteins. Since both albumin and immunoglobulins are not removed, or to a negligible extent, plasma-expanders, substitution fluids, and in particular albumin, as occurs in PEX are not needed. CF however, is characterized by lower selectivity since removes also high density lipoprotein (HDL) particles which have an antiatherogenic activity. In the 80’s, a variation of Lipid-apheresis has been developed which allows the LDL-cholesterol (LDLC) (-61%) and Lp(a) (-60%) removal from plasma through processing 3 liters of filtered plasma by means of lipid-specific thermofiltration, LDL immunoadsorption, heparin-induced LDL precipitation, LDL adsorption through dextran sulphate. More recently (90’s) the DALI®, and the Liposorber D® hemoperfusion systems, effective for apoB100- containing lipoproteins removal have been developed. All the above mentioned systems are established LDL-apheresis techniques referable to the generic definition of LDLa. However, this last definition cannot describe in an appropriate manner the removal of another highly atherogenic lipoprotein particle: the Lp(a). Thus it would be better to refer the above mentioned techniques to the wider scientific and technical concept of lipoprotein apheresis. Lipid apheresis - Lipoprotein apheresis - LDL-apheresis - Severe Dyslipidemia.
Resumo:
The present work investigates the fouling mechanisms of PVDF hollow fibre membrane (0.03 μm) during the dead end ultrafiltration at a fixed permeate flux (outside to inside configuration) of complex synthetic seawater composed by humic acids, alginic acids, inorganic particles and numerous salts at high concentrations. Short term ultrafiltration experiments at 100 L.h-1.m-2 show that the optimal specific filtered volume seems to be equal to 50 L.m-2. A residual fouling resistance equal to 2.1010 m-1 is added after each cycle of filtration during 8h of ultrafiltration at 100 L.h-1.m-2 and 50 L.m-2. Most of the fouling is reversible (80%). Organics are barely (15% of humic acids) retained by the membrane. Backwash efficiency drops during operation which induces less organics into backwash waters. Humic acids could preferentially accumulate on the membrane early in the ultrafiltration and alginic acids after the build-up of a fouling pre-layer. Colloids and particulates could accumulate inside a heterogeneous fouling layer and/or the concentrate compartment of the membrane module before being more largely recovered inside backwash waters.
Resumo:
The objective of this study was to assess the impact of the filtration method (in situ vs. ex situ) on the dissolved/particulate partitioning of 12 elements in hydrothermal samples collected from the Lucky Strike vent field (Mid-Atlantic Ridge; MAR). To do so, dissolved ( <0.45 mu m) and particulate Mg, Li, Mn, U, V, As, Ba, Fe, Zn, Cd, Pb and Cu were measured using different techniques (HR-ICP-MS, ICP-AES and CCSA). Using in situ filtration as a baseline, we showed that ex situ filtration (on-board and on shore after freezing) resulted in an underestimation of the dissolved pool, which was counterbalanced by an overestimation of the particulate pool for almost all the elements studied. We also showed that on-board filtration was acceptable for the assessment of dissolved and particulate Mn, Mg, Li and U for which the measurement bias for the dissolved fraction did not exceed 3%. However, in situ filtration appeared necessary for the accurate assessment of the dissolved and particulate concentrations of V, As, Fe, Zn, Ba, Cd, Pb and Cu. In the case of Fe, on-board filtration underestimated the dissolved pool by up to 96%. Laboratory filtration (after freezing) resulted in a large bias in the dissolved and particulate concentrations, unambiguously discounting this filtration method for deep-sea chemical speciation studies. We discuss our results in light of the precipitation processes that can potentially affect the accuracy of ex situ filtration methods.
Resumo:
Objective: The aim of this study was to evaluate the correlation between cholesterol levels and the glomerular filtration rate of adult patients in a Portuguese sample.
Resumo:
Several Cronobacter outbreaks have implicated contaminated drinking water. This study assessed the impact of granular activated carbon (GAC) on the microbial quality of the water produced. A simulated water filter system was installed by filling plastic columns with sterile GAC, followed by sterile water with a dilute nutrient flowing through the column at a steady rate. Carbon columns were inoculated with Cronobacter on the surface, and the effluent monitored for Cronobacter levels. During a second phase, commercial faucet filters were distributed to households for 4-month use. Used filters were backwashed with sterile peptone water, and analyzed for Cronobacter, total aerobic plate count, coliform bacteria and Enterobacteriaceae. Cronobacter colonized the simulated GAC and grew when provided minimal levels of nutrients. Backwashed used filters used in home settings yielded presumptive Escherichia coli, Pseudomonas and other waterborne bacteria. Presumptive Cronobacter strains were identified as negative through biochemical and genetic test.
Resumo:
In the current study, a new approach has been developed for correcting the effect that moisture reduction after virgin olive oil (VOO) filtration exerts on the apparent increase of the secoiridoid content by using an internal standard during extraction. Firstly, two main Spanish varieties (Picual and Hojiblanca) were submitted to industrial filtration of VOOs. Afterwards, the moisture content was determined in unfiltered and filtered VOOs, and liquid-liquid extraction of phenolic compounds was performed using different internal standards. The resulting extracts were analyzed by HPLC-ESI-TOF/MS, in order to gain maximum information concerning the phenolic profiles of the samples under study. The reduction effect of filtration on the moisture content, phenolic alcohols, and flavones was confirmed at the industrial scale. Oleuropein was chosen as internal standard and, for the first time, the apparent increase of secoiridoids in filtered VOO was corrected, using a correction coefficient (Cc) calculated from the variation of internal standard area in filtered and unfiltered VOO during extraction. This approach gave the real concentration of secoiridoids in filtered VOO, and clarified the effect of the filtration step on the phenolic fraction. This finding is of great importance for future studies that seek to quantify phenolic compounds in VOOs.