949 resultados para Facade walls


Relevância:

10.00% 10.00%

Publicador:

Resumo:

9th International Masonry Conference 2014, 7-9 July, Universidade do Minho, Guimarães

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seismic events are a major factor to consider in structural design of buildings in many countries. With the purpose of saving lives, most of the design codes lead to structural solutions that withstand large seismic actions without collapsing, but without taking into account a possible usage of the structures after the earthquake. As a result, it is necessary to consider the time needed to repair/retrofit the damaged structures (i.e. the downtime) since this period of inactivity may result in huge financial implications for the occupants of the buildings. In order to minimise the damages and simplify repair operations, structural solutions with rocking systems and negligible residual displacements have been developed during the last two decades. Systems with precast concrete rocking walls were studied with the aim of investigat- ing suitable and convenient structural alternatives to minimise the damage in case of an earthquake. Experimental, numerical and analytical analyses on post-tensioned solutions, with and without energy dissipation devices, were carried out in this research. The energy dissipation devices were made from steel angles that were further developed during the research. Different solutions for these devices were experimentally tested under cyclic loading and the results are presented. Numerical and analytical work on steel angles was also carried out. Regarding the concrete rocking wall systems, two concrete rocking wall systems were studied: post-tensioned walls and post-tensioned walls with energy dissipation devices. In the latter, the solution was to fix them externally to the wall, allowing their easy replacement after an earthquake. It is shown that the dissipaters are a viable solution for use in precast concrete rocking wall systems. A building case study is presented. The comparison between a traditional monolithic system and a hybrid solution was carried out, allowing the evaluation of the efficiency of the solution that was developed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years there has been a growing interest in developing news solutions for more ecologic and efficient construction, including natural, renewable and local materials, thus contributing in the search for more efficient, economic and environmentally friendly construction. Several authors have assessed the possibility of using various agricultural sub products or wastes, as part of the effort of the scientific community to find alternative and more ecologic construction materials. Corn cob is an agricultural waste from a very important worldwide crop. Natural glues are made from natural materials, non-mineral, that can be used as such or after some modifications to achieve the behaviour and performance required. Two examples of these natural glues are casein and wheat flour-based glues that were used in the present study. Boards with different compositions were manufactured, having as variables the type of glue, the dimension of the corn cob particles and the features of the pressing process. The tests boards were characterized with physical and mechanical tests, such as thermal conductivity (λ) with a ISOMET 2104 and 60 mm diameter contact probe, density (ρ) based on EN 1602:2013, surface hardness (SH) with a PCE Shore A durometer, surface resistance (SR) with a PROCEQ PT pendular sclerometer, bending behaviour (σ) based on EN 12089:2013, compression behaviour (σ10) based on EN 826:2013 and resilience (R) based on EN 1094-1:2008, with a Zwick Rowell bending equipment with 2 kN and 50 kN load cells (Fig. 1), dynamic modulus of elasticity (Ed) with a Zeus Resonance Meter equipment (Fig. 5) based on NP EN 14146:2006 and water vapour permeability (δ) based on EN 12086:2013. The various boards produced were characterized according to the tests and the ones with the best results were C8_c8 (casein glue, grain size 2,38-4,76 mm, cold pressing for 8 hours), C8_c4 (casein glue, grain size 2,38-4,76 mm, cold pressing for 4 hours), F8_h0.5 (wheat flour glue, grain size 2,38-4,76 mm, hot pressing for 0,5 hours), FEV8_h0.5 (wheat flour, egg white and vinegar glue, grain size 2,38-4,76 mm, hot pressing for 0,5 hours) and FEVH68_c4 (wheat flour, egg white, vinegar and 6 g of sodium hydroxide glue, grain size 2,38-4,76 mm, cold pressing for 4 hours). Taking into account the various boards produced and respective test results the type of glue and the pressure and pressing time are very important factors which strongly influence the final product. The results obtained confirmed the initial hypotheses that these boards have potential as a thermal and, eventually, acoustic insulation material, to use as coating or intermediate layer on walls, floors or false ceilings. This type of board has a high mechanical resistance when compared with traditional insulating materials.The integrity of these boards seems to be maintained even in higher humidity environments. However, due to biological susceptibility and sensitivity to water, they would be more adequate for application in dry interior conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Infection with Leishmania chagasi is the most common clinical presentation for visceral leishmaniaisis in endemic areas. The municipality of Raposa is an endemic area in State of Maranhão, Brazil, and have had registration cases of visceral leishmaniasis disease. For this reason, a cross- sectional study was conducted to evaluate the risk factors for infection with L. chagasi detected by Montenegro skin test. METHODS: The sample comprised 96% of the inhabitants of the villages of Maresia, Pantoja, and Marisol located in the municipality of Raposa, corresponding to 1,359 subjects. Data were collected using a questionnaire. Univariate and multivariate logistic regression models were applied to evaluate the association between the variables studied and infection of L. chagasi. RESULTS: The variables associated with infection upon nonadjusted analysis were a straw roof, mud walls, floors of beaten earth, presence of sand flies inside or outside of the dwelling, and bathing outdoors. Adjusted analysis showed that the presence of sand flies inside/outside the dwelling was a risk factor, and age younger than 10 years was a protective factor against asymptomatic infection. CONCLUSIONS: The results highlight the extent to which precarious living conditions of the population strengthen the epidemiological chain of visceral leishmaniasis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Clayish earth-based mortars are been recognized, all over the world, as eco-efficient products for plastering. Apart from being a product with low embodied energy when compared to other types of plasters, their application on the interior surface of walls may give a strong contribution for the health and comfort of inhabitants. As part of an ongoing research regarding earth-based plasters this work assesses the influence of the addition of two types of natural fibres – oat straw and typha fiber-wool – on the characteristics of plastering mortars made with a clayish earth. Mechanical and physical characteristics were tested, showing that addition of these fibers contribute to decrease linear drying shrinkage and thermal conductivity, as well as promoting the adhesion strength of plaster to the substrate. The improvement of mechanical resistance reveal to be dependent on the type of fiber added while the hygroscopic capacity of the plaster is maintained regardless of the fiber additions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The present study identified the triatomines collected in intra and peri-domestic environments, observed the occurrence of Trypanosoma cruzi infection in triatomines and correlated this information with housing conditions and the fauna associated with the rural areas of the City of Itabaianinha, located in the State of Sergipe, Brazil. METHODS: Quarterly visits were conducted between March 2009 and March 2010, and the homes to be visited for the active search of insects were determined by random selection. In each housing unit, the insects were collected by a manual search with a metal clip and flashlight to inspect openings and cavities, with a collection time of one hour/home/individual. The Pirisa® dislodge chemical was used to force the insects to leave their ecotopes. Analysis of the intestinal contents of triatomines was performed in the laboratory to establish the presence of Trypanosomatidae. RESULTS: Of the 103 dwellings surveyed, 17.5% were infested with Panstrongylus megistus. The village of Mutuca exhibited the highest infestation rate (38.1%). All the villages with relevant infestation rates were situated in the northern area of the city. The highest percentage of vector infection was found in the village of Água Boa (56.5%). The rural dwellings were found to be primarily brick or wooden house with or without roughcast or plastered walls, and the outbuilding most frequently associated with triatomines was the chicken run. CONCLUSIONS: These results emphasise the need for broader vector control and surveillance and for educational campaigns in the context of the Chagas Disease Control Program.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main purpose of the research is to present a proposal for a methodology to support the rehabilitation project of renders of old buildings in Portugal. To achieve the objective it was considered essential to define the main types of participants and aspects to integrate the proposal. The research methodology consists in an inquiry presented to professional participants in rehabilitation, a market study of materials and products available in Portugal, the design of a methodology proposal and its application to a case study. The inquiry sample totals 24 answers from the targeted professionals. A sequence of relevant supporting procedures consists in the proposal, which aims to provide a supporting methodology to decide and project in this context and also to be tested with its application to the building. This proposal was applied to an old building with load-bearing stone masonry walls and air-lime based renders. It was concluded that the assessment of the building and external renderings’ condition, its diagnosis and of the supporting walls, the definition of intervention, the specification of materials to be used and performance requirements to comply, and also plans for conservation and periodic maintenance, are crucial. From the inquiry, compatibility between materials and complementary roles and points of view of different types of participants in rehabilitation must be highlighted. A proposal for a methodology to support the project could provide useful guidance particularly for architects and construction engineers, and improve the understanding of direct participants on site, therefore contributing for the correct implementation of intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years it has been noticed the progressive disappearance of vernacular sustainable building technologies all over the world mainly due to a strong urban rehabilitation process with modern technologies not compatible with ancient knowledge. Simultaneously new dwellings are needed all over the world and in this sense it was decided to study an ecological and cost-controlled building technology of monolithic walls that can combine the use of low carbon footprint materials, such as earth, fibres and lime using an invasive species: giant reed cane (Arundo Donax). This paper explains the development of this building technology through testing diverse prototypes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main purpose of the research is to present a proposal for a methodology to support the rehabilitation project of renders of old buildings. To achieve the objective it was considered essential to define the main types of participants and aspects to integrate the proposal. The research methodology consists in an inquiry presented to several professional participants in rehabilitation, a market study of materials and products available in Portugal, the design of a methodology proposal and its application to a case study. The inquiry sample totals 24 answers from the targeted professionals. A sequence of relevant supporting procedures consists in the proposal, which aims to provide a supporting methodology to decide and project in this context and also to be tested with its application to the building. This proposal was applied to an old building with load-bearing stone masonry walls and air-lime based renders. It was concluded that the assessment of the building and external renderings’ condition, its diagnosis and of the supporting walls, the definition of intervention, the specification of materials to be used and performance requirements to comply, and also plans for conservation and periodic maintenance, are crucial. From the inquiry, compatibility between materials and complementary roles and points of view of different types of participants in rehabilitation must be highlighted. A proposal for a methodology to support the project could provide useful guidance particularly for architects and construction engineers, and improve the understanding of direct participants on site, therefore contributing for the correct implementation of the intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

All over the world, many earth buildings are deteriorating due to lack of maintenance and repair. Repairs on rammed earth walls are mainly done with mortars, by rendering application; however, often the repair is inadequate, resorting to the use of incompatible materials, including cement-based mortars. It has been observed that such interventions, in walls that until that day only had presented natural ageing issues, created new problems, much more dangerous for the building than the previous ones, causing serious deficiencies in this type of construction. One of the problems is that the detachment of the new cement-based mortar rendering only occurs after some time but, until that occurrence, degradations develop in the wall itself. When the render detaches, instead of needing only a new render, the surface has to be repaired in depth, with a repair mortar. Consequently, it has been stablished that the renders, and particularly repair mortars, should have physical, mechanical and chemical properties similar to those of the rammed earth walls. This article intends to contribute to a better knowledge of earth-based mortars used to repair the surface of rammed earth walls. The studied mortars are based on four types of earth: three of them were collected from non-deteriorated parts of walls of unstabilized rammed earth buildings located in Alentejo region, south of Portugal; the fourth is a commercial earth, consisting mainly of clay. Other components were also used, particularly: sand to control shrinkage; binders stabilizers such as dry hydrated air-lime, natural hydraulic lime, Portland cement and natural cement; as well as natural vegetal fibers (hemp fibers). The experimental analysis of the mortars in the fresh state consisted in determining the consistency by flow table and the bulk density. In the hardened state, the tests made it possible to evaluate the following properties: linear and volumetric shrinkage; capillary water absorption; drying capacity; dynamic modulus of elasticity; flexural and compressive strength.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Characterization of the structural changes occurring in the pulmonary arteries resulting from surgically produced congenital diaphragmatic hernia in rabbits, with particular emphasis on the preventive effects of prenatal tracheal ligation or administration of intra-amniotic dexamethasone or surfactant. METHODS: Twenty rabbit fetuses underwent surgical creation of a left-sided congenital diaphragmatic hernia on the 24th or 25th gestational day. They were divided according to the following procedures: congenital diaphragmatic hernia (n = 5), congenital diaphragmatic hernia plus tracheal ligation (n = 5), congenital diaphragmatic hernia plus intra-amniotic administration of dexamethasone 0.4 mg (n = 5) or surfactant (Curosurf 40 mg, n = 5). On gestational day 30, all the fetuses were delivered by caesarean section and killed. A control group consisted of five nonoperated fetuses. Histomorphometric analysis of medial thickness, cell nuclei density, and elastic fiber density of pulmonary arterial walls was performed. RESULTS: Arteries with an external diameter > 100 mum have a decreased medial thickness, lower cell nuclei density, and greater elastic fiber density when compared with arteries with external diameter <= 100 mum. Congenital diaphragmatic hernia promoted a significant decrease in medial thickness and an increase in cell nuclei density in artery walls with external diameter > 100 mum. Prenatal treatments with tracheal ligation or intra-amniotic administration of dexamethasone or surfactant prevented these changes. In arteries with external diameter <= 100 mum, congenital diaphragmatic hernia promoted a significant increase in medial thickness and in cell nuclei density and a decrease in elastic fiber density. The prenatal treatments with tracheal ligation or intra-amniotic administration of dexamethasone or surfactant prevented these changes, although no effect was observed in elastic fiber density in the congenital diaphragmatic hernia plus dexamethasone group. CONCLUSIONS: Congenital diaphragmatic hernia promoted different structural changes for large or small arteries. The prenatal intra-amniotic administration of dexamethasone or surfactant had positive effects on the lung structural changes promoted by congenital diaphragmatic hernia, and these effects were comparable to the changes induced by tracheal ligation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Diffuse panbronchiolitis is a clinical pathologic condition characterized by chronic inflammation of respiratory bronchioles, with clinical features that position it as a differential diagnosis among the sinopulmonary syndromes. METHODS AND RESULTS: We present 4 cases (1 Black, 2 Japanese descendants, and 1 Japanese), living in Brazil, in which the diagnosis was made by the clinical and radiological features and confirmed by transbronchial biopsy. The clinical findings included chronic sinusitis, productive cough, rhonchi, and wheezes. The pulmonary function tests showed an obstructive pattern. High resolution computerized tomography showed a diffuse nodular pattern, airway ectasia, and airway wall thickening. The biopsy showed interstitial accumulation of foam cells and lymphoid cells in the walls of respiratory bronchioles: 2 of our cases had bronchus-associated lymphoid tissue hyperplasia. We searched for the HLA Bw54 in all of our patients, but only 1 was positive. A low dose macrolide treatment was introduced, resulting in with clinical and functional improvement. A score that rated the extent of nodules, airway ectasia, mucus plugging, and airway wall thickening was applied on pre- and post-treatment High resolution computerized tomography results, revealing an improvement in tomographic pattern related to that observed in the pulmonary function tests. CONCLUSION: We conclude that diffuse panbronchiolitis is a systemic disease that is not exclusive to the Asian population, whose clinical and radiological features should be better known by occidental pulmonary physicians.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the investigation and diagnosis of damages to historical masonry structures, the state of stress of the masonry is an important characteristic that must be determined with as much accuracy as possible. Flat-jack testing is a traditional method used to determine the state of stress in historical masonry structures. However, when irregular masonry is tested the method can cause damage to the masonry units and the accuracy of the method is reduced. An enhanced technique, called tube-jack testing, is being developed at the University of Minho to reduce the damage caused during testing and improve the accuracy when used on irregular masonry. This method uses multiple cylindrical jacks inserted in a line of holes drilled in the mortar joints of the masonry, avoiding damage to the masonry units. Concurrently with the development of tube-jack testing, the effect of stress state on sonic testing is being studied. Sonic testing is often used to determine locations of voids and damage in masonry. The focus of these studies was to determine if the state of stress is influencing the sonic test results. In this paper the results of tube-jack testing and sonic testing on masonry walls, built for the purpose of this study in the laboratory, loaded in compression is presented. The tube-jack testing is used to estimate the state of stress in the masonry and the sonic test results are evaluated based on the effect of the applied load on the wall. Future testing and study are suggested for continued development of these test methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Timber connections represent the crucial part of a timber structure and a great variability exists in terms of types of connections and mechanisms. Taking as case study the widespread traditional timber frame structures, in particular the Portuguese Pombalino buildings, one of the most common timber connection is the half-lap joint. Connections play a major role in the overall behaviour of a structure, particularly when assessing their seismic response, since damage is concentrated at the connections. For this reason, an experimental campaign was designed and distinct types of tests were carried out on traditional half-lap joints to assess their in-plane response. In particular, pull-out and in-plane cyclic tests were carried out on real scale unreinforced connections. Subsequently, the connections were retrofitted, using strengthening techniques such as self-tapping screws, steel plates and GFRP sheets. The tests chosen were meant to capture the hysteretic behaviour and dissipative capacity of the connections and characterise their response and, therefore, their influence on the seismic response of timber frame walls, particularly concerning their uplifting and rotation capacity, that could lead to rocking in the walls. In this paper, the results of the experimental campaign are presented in terms of hysteretic curves, dissipated energy and equivalent viscous damping ratio. Moreover, recommendations are provided on the most appropriate retrofitting solutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the assessment of the out-of-plane response due to seismic loading of a masonry structure without rigid diaphragm. This structure corresponds to real scale brick masonry specimen with a main façade connected to two return walls. Two modelling approaches were defined for this evaluation. The first one consisted on macro modelling, whereas the second one on simplified micro modelling. As a first step of this study, static nonlinear analyses were conducted to the macro model aiming at evaluating the out-of-plane response and failure mechanism of the masonry structure. A sensibility analyses was performed in order to assess the mesh size and material model dependency. In addition, the macro models were subjected to dynamic nonlinear analyses with time integration in order to assess the collapse mechanism. Finally, these analyses were also applied to a simplified micro model of the masonry structure. Furthermore, these results were compared to experimental response from shaking table tests. It was observed that these numerical techniques simulate correctly the in-plane behaviour of masonry structures. However, the