919 resultados para FIBER MICROELECTRODES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel launch scheme is proposed for multimode-fiber (MMF) links. Enhanced performance in 10 Gb/s MMF links using electronic equalization is demonstrated by statistical analysis of installed-base fiber and an experimental investigation. © 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transmitter-based equalization is investigated for enhanced performance in 10 Gb/s multimodefiber links. Rigorous simulations and proof-of-principle experiments over 500 m of FDDI-grade fiber confirm for the first time the potential superiority of the technique relative to receiver-based schemes. © 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel twin-spot launch is proposed for multimode-fiber (MMF) links. Experimental and theoretical investigation of the launch indicates a penalty reduction of ≈50% of the 10 Gigabit Ethernet allocation for EDC-enabled links over worst-case MMF. © 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rigorous statistical analysis is applied for the first time to identify optimal launch conditions and carrier frequencies for SCM transmission over worst-case MMF. The feasibility of multichannel schemes for 10 Gb/s over 300 m is demonstrated. © 2005 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uncooled directly-modulated 1.3μm VCSELs are shown to exhibit dynamic range, linearity and noise performance required for wireless LAN applications. A multimode fiber based WLAN 802.11b system shows performances comparable to systems with state-of-the-art DFB lasers. © 2005 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uncooled directly-modulated 1.3μm VCSELs are shown to exhibit dynamic range, linearity and noise performance required for wireless LAN applications. A multimode fiber based WLAN 802.11b system shows performances comparable to systems with state-of-the-art DFB lasers. © 2005 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rigorous statistical analysis is applied for the first time to identify optimal launch conditions and carrier frequencies for SCM transmission over worst-case MMF. The feasibility of multichannel schemes for 10 Gb/s over 300 m is demonstrated. © 2005 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel fiber coated with novel sol-gel (5,11,17,23-tetra-tert-butyl-25,27-dihydroxy-26,28-diglycidyloxycalix[4]arene/hydroxy-terminated silicone oil; diglycidyloxy-C[4]/OH-TSO) was prepared for use with headspace solid-phase microextraction (HS-SPME) combined with gas chromatography (GC) and electron capture detection (ECD), which was applied in order to determine nine chlorobenzenes in soil matrices. Due to the improved fiber preparation, which increases the percentage of calixarene in the coating, the new calixarene fiber exhibits very high extraction selectivity and sensitivity to chlorine-substituted compounds. Various parameters affecting the extraction efficiency were optimized in order to maximize the sensitivity during the chlorobenzene analysis. Interferences from different soil matrices with different characteristics were investigated, and the amount extracted was strongly influenced by the matrix. Therefore, a standard addition protocol was performed on the real soil samples. The linear ranges of detection for the chlorobenzenes tested covered three orders of magnitude, and correlation coefficients > 0.9976 and relative standard deviations (RSD) < 8% were observed. The detection limits were found at sub-ng/g of soil levels, which were about an order of magnitude lower than those given by the commercial poly(dimethylsiloxane) (PDMS) coating for most of the compounds. The recoveries ranged from 64 to 109.6% for each analyte in the real kaleyard soil matrix when different concentration levels were determined over the linear range, which confirmed the reliability and feasibility of the HS-SPME/GC-ECD approach using the fiber coated with diglycidyloxy-C[4]/OH-TSO for the ultratrace analysis of chlorobenzenes in complex matrices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single-wall carbon nanotubes (SWNTs) and graphene have emerged as promising saturable absorbers (SAs), due to their broad operation bandwidth and fast recovery times [1-3]. However, Yb-doped fiber lasers mode-locked using CNT and graphene SAs have generated relatively long pulses. All-fiber cavity designs are highly favored for their environmental robustness. Here, we demonstrate an all-fiber Yb-doped laser based on a SWNT saturable absorber, which allows generation of 8.7 ps-long pulses, externally compressed to 118 fs. To the best of our knowledge, these are the shortest pulses obtained with SWNT SAs from a Yb-doped fiber laser. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonic solvent extraction combined with solid-phase microextraction (SPME) with calix[4]arene/hydroxy-terminated silicone (C[4]/OHTSO) oil coated fiber was used to extract phthalate acid esters (PAEs) plasticizers in plastic, such as blood bags, transfusion tubing, food packaging bag, and mineral water bottle for analysis by gas chromatography (GC). Both extraction parameters (i.e. extraction time, extraction temperature, ionic strength) and conditions of the thermal desorption in a GC injector were optimized by analysis of eight phthalates. The fiber shows wonderful sensitivity and selectivity to the tested compounds. Owing to its high thermal stability (380 degreesC), the carryover effect that often encountered when using conventional fibers can be reduced by appropriately enhancing the injector temperature. The method showed linear response over two to four orders of magnitude with correlation coefficients (r) better than 0.996, and limits of detection (LOD) ranged between 0.006 and 0.084 mug l(-1). The relative standard deviation values obtained were less than or equal to 10%. bis-2-Ethylhexyl phthalate (DEHP) was the sole analyte detected in these plastics and recoveries were in the ranges 95.5-101.4% in all the samples. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transmission properties of data amplitude modulation (AM) and frequency modulation (FM) in radio-over-fiber (RoF) system are studied numerically. The influences of fiber dispersion and nonlinearity on different microwave modulation schemes, including double side band (DSB), single side band (SSB) and optical carrier suppression (OCS), are investigated and compared. The power penalties at the base station (BS) and the eye opening penalties of the recovered data at the end users are both calculated and analyzed. Numerical simulation results reveal that the power penalty of FM can be drastically decreased due to the larger modulation depth it can achieve than that of AM. The local spectrum broadening around subcarrier microwave frequency of AM due to fiber nonlinearity can also be eliminated with FM. It is demonstrated for the first time that the eye openings of the FM recovered data can be controlled by its modulation depths and the coding formats. Negative voltage encoding format was used to further decrease the RF frequency thus increase the fluctuation period considering their inverse relationship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The idler is separated from the co-propagating pump in a degenerate four-wave mixing (DFWM) with a symmetrical parametric loop mirror (PALM), which is composed of two identical SOAs and a 70 m highly-nonlinear photonic crystal fiber (HN-PCF). The signal and pump are coupled into the symmetrical PALM from different ports, respectively. After the DFWM based wavelength conversion (WC) in the clockwise and anticlockwise, the idler exits from the signal port, while the pump outputs from its input port. Therefore, the pump is effectively suppressed in the idler channel without a high-speed tunable filter. Contrast to a traditional PALM, the DFWM based conversion efficiency is increased greatly, and the functions of the amplification and the WC are integrated in the smart SOA and HN-PCF PALM. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fiber Bragg grating (FBG) hydrophone with high sensitivity was demonstrated. This hydrophone used a rubber diaphragm and a copper hard core as the sensing element. To compensate the hydrostatic pressure, a capillary tube was fixed at the end of the hydrophone. Theoretical analysis of the acoustic pressure sensitivity was given in this letter. Experiments were carried out to test the frequency response of the hydrophone. The result shows that when the Young's modulus of the diaphragm is higher, a flatter frequency response will be obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed study on analyzing the crosstalk in a wavelength division multiplexed fiber laser sensor array system based on a digital phase generated carrier interferometric interrogation scheme is reported. The crosstalk effects induced by the limited optical channel isolation of a dense wavelength division demultiplexer (DWDM) are presented, and the necessary channel isolation to keep the crosstalk negligible to the output signal was calculated via Bessel function expansion and demonstrated by a two serial fiber laser sensors system. Finally, a three-element fiber laser sensor array system with a 50-dB channel-isolation DWDM was built up. Experimental results demonstrated that there was no measurable crosstalk between the output channels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fiber laser hydrophone with enhanced sensitivity is demonstrated. Two diaphragms with a hard core fixed at each center are used as the sensing element. Theoretical analysis shows that the Young's modulus of the diaphragm and the radius of the hard core have significant effect on the acoustic sensitivity. Experiments are carried out to test this effect and the performance of the hydrophone. The experimental result agrees well with the theoretical result, and a sensitivity of 7 nm/MPa has been achieved.