980 resultados para Ensaios em ANSYS workbench e ANSYS classic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research is developed in areas of horticulture in the city of Natal, in the neighborhoods of Lagoa Azul, Pajuçara and Redinha, along the Doce River, border area with Extremoz city, Rio Grande do Norte State. The region of the fluvial plain of Doce River is located in an Environmental Protection Zone (ZPA-9). This is one of the ZPA which is not under the regulatory marks and there are several environmental problems caused by use and land occupation, featuring an evident disregard of environmental laws and whose protection is hindered by the lack of specific legal mechanisms. This study aims to provide an overview of the use of pesticides in the lower course of the Doce River, in Natal, Rio Grande do Norte, and to assess environmental degradation in the area through chronic toxicity tests using the microcrustaceous Ceriodaphnia dubia Richard 1894 (Cladocera, Crustacea) as test organism. Visits were made to the area in 2009 and 2010. To obtain information a diagnosis of the local situation was accomplished based on personal observation and non-participatory photographic record, with the aim of assessing the environmental characteristics, population diversity and work processes of horticulturists. During the visits four different points of the Doce River were chosen to collect water for ecotoxicological tests and survey of physico-chemical parameters (dissolved oxygen, pH, chloride, turbidity, conductivity and temperature), which were measured in the field using Multiparameter Probe (TROLL 9500). The adverse effects of pesticide use in the lower course of the Doce River is a major problem for both the environmental and human health, since many of the substances and active principles that enter in the composition of the products are synthesized molecules whose effects can only be evaluated through different studies on their actions and behavior at short, medium or long term

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study explores the symbolism of evil way in the novel Grande sertão: veredas, by Guimarães Rosa, regarding faustian pact by Goethe, and so tries to understand how the rosiana language are present to the strategies which put in suspense the effectiveness of the demonic agreement and enable, with poetic intensity, different interpretations, especially as regards the anguish of the human condition. This research thus has drawn upon the Mythical Symbolism, in Literary Criticism and aspects of Metaphysics, in addition to analyzing classic literary essays in approaching of Rosa s masterpiece structure. It has also demonstrated that the incorporation of the Faust legend in Grande sertão reflects the same desire for happiness that is not done completely, and in this manner, instigates a discussion about the limits to the satisfaction of being human. Therefore, it has observed that epic narrative of ex-gangster Riobaldo to the doctor of city speculates on human man, in the continuous learning of his passing

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Genetic biomarkers of head and neck tumors could be useful for distinguishing among patients with similar clinical and histopathologic characteristics but having differential probabilities of survival. The purpose of this study was to investigate chromosomal alterations in head and neck carcinomas and to correlate the results with clinical and epidentiologic variables.Experimental Design: Cytogenetic analysis of short-term cultures from 64 primary untreated head and neck squamous cell carcinomas was used to determine the overall pattern of chromosome aberrations. A representative subset of tumors was analyzed in detail by spectral karyotyping and/or confirmatory fluorescence in situ hybridization analysis.Results: Recurrent losses of chromosomes Y (26 cases) and 19 (14 cases), and gains of chromosomes 22 (23 cases), 8 and 20 (11 cases each) were observed. The most frequent structural aberration was del(22)(q13.1) followed by rearrangements involving 6q and 12p. The presence of specific cytogenetic aberrations was found to correlate significantly with an unfavorable outcome. There was a significant association between survival and gains in chromosomes 10 (P = 0.008) and 20 (P = 0.002) and losses of chromosomes 15 (P = 0.005) and 22 (P = 0.021). Univariate analysis indicated that acquisition of monosomy 17 was a significant (P = 0.0012) factor for patients with a previous family history of cancer.Conclusions: the significant associations found in this study emphasize that alterations of distinct regions of the genome may be genetic biomarkers for a poor prognosis. Losses of chromosomes 17 and 22 can be associated with a family history of cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare the influence of single-standing or connected implants on stress distribution in bone of mandibular overdentures by means of two-dimensional finite element analysis. Two finite element models were designed using software (ANSYS) for 2 situations: bar-clip (BC) group-model of an edentulous mandible supporting an overdenture over 2 connected implants with BC system, and o'ring (OR) group-model of an edentulous mandible supporting an overdenture over 2 single-standing implants with OR abutments. Axial loads (100 N) were applied on either central (L1) or lateral (L2) regions of the models. Stress distribution was concentrated mostly in the cortical bone surrounding the implants. When comparing the groups, BC (L1, 52.0 MPa and L2, 74.2 MPa) showed lower first principal stress values on supporting tissue than OR (L1, 78.4 MPa and L2, 76.7 MPa). Connected implants with BC attachment were more favorable on stress distribution over peri-implant-supporting tissue for both loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study aimed to evaluate the influence of implants with or without threads representation on the outcome of a two-dimensional finite element (FE) analysis. Materials and Methods: Two-dimensional FE models that reproduced a frontal section of edentulous mandibular posterior bone were constructed using a standard crown/implant/screw system representation. To evaluate the effect of implant threads, two models were created: a model in which the implant threads were accurately simulated (precise model) and a model in which implants with a smooth surface (press-fit implant) were used (simplified model). An evaluation was performed on ANSYS software, in which a load of 133 N was applied at a 30-degree angulation and 2 mm off-axis from the long axis of the implant on the models, The Von Mises stresses were measured. Results: The precise model (1.45 MPa) showed higher maximum stress values than the simplified model (1.2 MPa). Whereas in the cortical bone, the stress values differed by about 36% (292.95 MPa for the precise model and 401.14 MPa for the simplified model), in trabecular bone (19.35 MPa and 20.35 MPa, respectively), the stress distribution and stress values were similar. Stress concentrations occurred around the implant neck and the implant apex. Conclusions: Considering implant and cortical bone analysis, remarkable differences in stress values were found between the models. Although the models showed different absolute stress values, the stress distribution was similar. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:1040-1044

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the stress distribution induced by posterior functional loads on conventional complete dentures and implant-retained overdentures with different attachment systems using a two-dimentional Finite Element Analysis (FEA-2D). Three models representative of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture over two splinted implants connected with the bar-clip system; Group C, a model of edentuluos mandible supporting an overdenture over two unsplinted impants with the O-ring system. Evaluation was conducted on Ansys software, with a vertical force of 100 N applied on the mandibular left first molar. When the stress was evaluated in supporting tissues, groups B (51.0 MPa) and C (52.6 MPa) demonstrated higher stress values than group A (10.1 MPa). Within the limits of this study, it may be conclued that the use of an attachment system increased stress values; furthermore, the use of splinted implants associated with the bar-clip attachment system favoured a lower stress distribution over the supporting tissue than the unsplinted implants with an O-ring abutment to retain the manibular overdenture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate, using three-dimensional finite element analysis (3D FEA), the stress distribution in peri-implant bone tissue, implants, and prosthetic components of implant-supported single crowns with the use of the platform-switching concept. Materials and Methods: Three 3D finite element models were created to replicate an external-hexagonal implant system with peri-implant bone tissue in which three different implant-abutment configurations were represented. In the regular platform (RP) group, a regular 4.1-mm-diameter abutment (UCLA) was connected to regular 4.1-mm-diameter implant. The platform-switching (PS) group was simulated by the connection of a wide implant (5.0 mm diameter) to a regular 4.1-mm-diameter UCLA abutment. In the wide-platform (WP) group, a 5.0-mm-diameter UCLA abutment was connected to a 5.0-mm-diameter implant. An occlusal load of 100 N was applied either axially or obliquely on the models using ANSYS software. Results: Both the increase in implant diameter and the use of platform switching played roles in stress reduction. The PS group presented lower stress values than the RP and WP groups for bone and implant. In the peri-implant area, cortical bone exhibited a higher stress concentration than the trabecular bone in all models and both loading situations. Under oblique loading, higher intensity and greater distribution of stress were observed than under axial loading. Platform switching reduced von Mises (17.5% and 9.3% for axial and oblique loads, respectively), minimum (compressive) (19.4% for axial load and 21.9% for oblique load), and maximum (tensile) principal stress values (46.6% for axial load and 26.7% for oblique load) in the peri-implant bone tissue. Conclusion: Platform switching led to improved biomechanical stress distribution in peri-implant bone tissue. Oblique loads resulted in higher stress concentrations than axial loads for all models. Wide-diameter implants had a large influence in reducing stress values in the implant system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:482-491

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred it) supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the tendency of displacement of the supporting structures of the distal extension removable partial denture (DERPD) associated to the implant with different inclinations of alveolar ridge and implant localizations through a two-dimensional finite-element method. Sixteen mandibular models were fabricated, presenting horizontal, distally descending, distally ascending, or descending-ascending ridges. All models presented the left canine and were rehabilitated with conventional DERPD or implant-retained prosthesis with the ERA system. The models were obtained by the AutoCAD software and transferred to the finite-element software ANSYS 9.0 for analysis. A force of 50 N was applied on the cusp tips of the teeth, with 5 points of loading of 10 N. The results were visualized by displacement maps. For all ridge inclinations, the assembly of the DERPD with distal plate retained by an anterior implant exhibited the lowest requisition of the supporting structures. The highest tendency of displacement occurred in the model with distally ascending ridge with incisal rest. It was concluded that the association of the implant decreased the displacement of the DERPD, and the anterior positioning of the implant associated to the DERPD with the distal plate preserved the supporting structures for all ridges.