505 resultados para Electromyography.
Resumo:
Previous research has shown that the postural configuration adopted by a subject, such as active leaning, influences the postural response to an unpredictable support surface translation. While those studies have examined large differences in postural conditions, it is of additional interest to examine the effects of naturally occurring changes in standing posture. Thus, it was hypothesized that the normal postural sway observed during quiet standing would affect the responses to an unpredictable support surface translation. Seventeen young adults stood quietly on a moveable platform and were perturbed in either the forward or backward direction when the location of the center of pressure (COP) was either 1.5 standard deviations anterior or posterior to the mean baseline COP signal. Postural responses, in the form of electromyographic (EMG) latencies and amplitudes, were recorded from lower limb and trunk muscles. When the location of the COP at the time of the translation was in the opposite, as compared to the same, direction as the upcoming translation, there was a significantly earlier onset of the antagonists (10-23%, i.e. 15-45 ms) and a greater EMG amplitude (14-39%) in four of the six recorded muscles. Stepping responses were most frequently observed during trials where the position of the COP was opposite to the direction of the translation. The results support the hypothesis that postural responses to unpredictable support surface translations are influenced by the normal movements of postural sway. The results may help to explain the large variability of postural responses found between past studies.
Resumo:
The purpose of this study was to investigate the effects of three different weight training protocols, that varied in the way training volume was measured, on acute muscular fatigue. Ten resistance-trained males performed all three protocols which involved dynamic constant resistance exercise of the elbow flexors. Protocol A provided a standard for the time the muscle group was under tension (TUT) and volume load (VL), expressed as the product of the total number of repetitions and the load that was lifted. Protocol B involved 40% of the TUT but the same VL compared to protocol A; protocol C was equated with protocol A for TUT but only involved 50% of the VL. Fatigue was assessed by changes in maximum voluntary isometric force and integrated electromyography (iEMG) between the pre- and post-training protocols. The results of the study showed that, when equated for VL, greater TUT produced greater overall muscular fatigue ( p
Resumo:
A novel surface electromyographic (EMG) technique was recently described for the detection of deep cervical flexor muscle activity. Further investigation of this technique is warranted to ensure EMG activity from neighbouring muscles is not markedly influencing the signals recorded. This study compared deep cervical flexor (DCF) muscle activity with the activity of surrounding neck and jaw muscles during various anatomical movements of the neck and jaw in 10 volunteer subjects. DCF EMG activity was recorded with custom electrodes inserted via the nose and fixed by suction to the posterior mucosa of the oropharynx. Surface electrodes were placed over the sternocleidomastoid, anterior scalene, masseter and suprahyoid muscles. Positioned in supine, subjects performed isometric cranio-cervical flexion, cervical flexion, right and left cervical rotation,jaw clench and resisted jaw opening. Across all movements examined, EMG amplitude of the DCF muscles was greatest during neck movements that would require activity of the DCF muscles, particularly during cranio-cervical flexion, their primary anatomical action. The actions of jaw clench and resisted jaw opening demonstrated significantly less DCF EMG activity than the cranio-cervical flexion action (p < 0.05). Across all other movements, the neighbouring neck and jaw muscles demonstrated greatest EMG amplitude during their respective primary anatomical actions, which occurred in the absence of increased EMG amplitude recorded from the DCF muscles. The finding of substantial EMG activity of the DCF muscles only during neck actions that would require their activity, particularly cranio-cervical flexion, and not during actions involving the jaw, provide further assurance that the majority of myoelectric signals detected from the nasopharyngeal electrode are from the DCF muscles. (C) 2005 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this study was to determine whether postural activity of the pelvic floor (PF) and abdominal muscles differs between continent and incontinent women during rapid arm movements that present a postural challenge to the trunk. A further aim was to study the effect of bladder filling. Electromyographic activity (EMG) of the PF, abdominal, erector spinae (ES), and deltoid muscles was recorded with surface electrodes. During rapid shoulder flexion and extension, PF EMG increased before that of the deltoid in continent women, but after the deltoid in incontinent women (p= 0.002). In many incontinent women, PF EMG decreased before the postural activation. Although delayed, postural PF EMG amplitude was greater in women with incontinence ( p= 0.010). In both groups, PF EMG decreased and abdominal and ES EMG increased when the bladder was moderately full. These findings would be expected to have negative consequences for continence and lumbopelvic stability in women with incontinence.
Resumo:
Study Design. A comparative study of trunk and hip extensor muscle recruitment patterns in 2 subject groups. Objective. To examine for changes in recruitment of the hip and back extensor muscles during low level isometric trunk rotation efforts in chronic low back pain (CLBP) subjects by comparison with matched asymptomatic control subjects. Summary of Background Data. Anatomic and biomechanical models have provided evidence that muscles attaching to the thoracolumbar fascia (TLF) are important for providing stabilization to the lumbopelvic region during trunk rotation. This has guided rehabilitation programs. The muscles that link diagonally to the posterior layer of the TLF have not previously been examined individually and compared during low-level trunk rotation efforts in CLBP patients and matched controls. Methods. Thirty CLBP patients and 30 matched controls were assessed using surface electromyography (EMG) as they performed low-level isometric rotation efforts while standing upright. Muscles studied included latissimus dorsi, erector spinae, upper and lower gluteus maximus, and biceps femoris. Subjects performed the rotation exertion with various levels of external trunk support, related to different functional tasks. Results. EMG results demonstrated that subjects with CLBP had significantly higher levels of recruitment for the lower and upper gluteus maximus (P < 0.05), hamstrings (P < 0.05), and erector spinae muscles (P < 0.05) during rotation to the left compared with the control subjects. Conclusion. This study provided evidence of increased muscle recruitment in CLBP patients when performing a standardized trunk rotation task. These results may have implications for the design of therapeutic exercise programs for CLBP patients.
Resumo:
This work has, as its objective, the development of non-invasive and low-cost systems for monitoring and automatic diagnosing specific neonatal diseases by means of the analysis of suitable video signals. We focus on monitoring infants potentially at risk of diseases characterized by the presence or absence of rhythmic movements of one or more body parts. Seizures and respiratory diseases are specifically considered, but the approach is general. Seizures are defined as sudden neurological and behavioural alterations. They are age-dependent phenomena and the most common sign of central nervous system dysfunction. Neonatal seizures have onset within the 28th day of life in newborns at term and within the 44th week of conceptional age in preterm infants. Their main causes are hypoxic-ischaemic encephalopathy, intracranial haemorrhage, and sepsis. Studies indicate an incidence rate of neonatal seizures of 0.2% live births, 1.1% for preterm neonates, and 1.3% for infants weighing less than 2500 g at birth. Neonatal seizures can be classified into four main categories: clonic, tonic, myoclonic, and subtle. Seizures in newborns have to be promptly and accurately recognized in order to establish timely treatments that could avoid an increase of the underlying brain damage. Respiratory diseases related to the occurrence of apnoea episodes may be caused by cerebrovascular events. Among the wide range of causes of apnoea, besides seizures, a relevant one is Congenital Central Hypoventilation Syndrome (CCHS) \cite{Healy}. With a reported prevalence of 1 in 200,000 live births, CCHS, formerly known as Ondine's curse, is a rare life-threatening disorder characterized by a failure of the automatic control of breathing, caused by mutations in a gene classified as PHOX2B. CCHS manifests itself, in the neonatal period, with episodes of cyanosis or apnoea, especially during quiet sleep. The reported mortality rates range from 8% to 38% of newborn with genetically confirmed CCHS. Nowadays, CCHS is considered a disorder of autonomic regulation, with related risk of sudden infant death syndrome (SIDS). Currently, the standard method of diagnosis, for both diseases, is based on polysomnography, a set of sensors such as ElectroEncephaloGram (EEG) sensors, ElectroMyoGraphy (EMG) sensors, ElectroCardioGraphy (ECG) sensors, elastic belt sensors, pulse-oximeter and nasal flow-meters. This monitoring system is very expensive, time-consuming, moderately invasive and requires particularly skilled medical personnel, not always available in a Neonatal Intensive Care Unit (NICU). Therefore, automatic, real-time and non-invasive monitoring equipments able to reliably recognize these diseases would be of significant value in the NICU. A very appealing monitoring tool to automatically detect neonatal seizures or breathing disorders may be based on acquiring, through a network of sensors, e.g., a set of video cameras, the movements of the newborn's body (e.g., limbs, chest) and properly processing the relevant signals. An automatic multi-sensor system could be used to permanently monitor every patient in the NICU or specific patients at home. Furthermore, a wire-free technique may be more user-friendly and highly desirable when used with infants, in particular with newborns. This work has focused on a reliable method to estimate the periodicity in pathological movements based on the use of the Maximum Likelihood (ML) criterion. In particular, average differential luminance signals from multiple Red, Green and Blue (RGB) cameras or depth-sensor devices are extracted and the presence or absence of a significant periodicity is analysed in order to detect possible pathological conditions. The efficacy of this monitoring system has been measured on the basis of video recordings provided by the Department of Neurosciences of the University of Parma. Concerning clonic seizures, a kinematic analysis was performed to establish a relationship between neonatal seizures and human inborn pattern of quadrupedal locomotion. Moreover, we have decided to realize simulators able to replicate the symptomatic movements characteristic of the diseases under consideration. The reasons is, essentially, the opportunity to have, at any time, a 'subject' on which to test the continuously evolving detection algorithms. Finally, we have developed a smartphone App, called 'Smartphone based contactless epilepsy detector' (SmartCED), able to detect neonatal clonic seizures and warn the user about the occurrence in real-time.
Resumo:
The thesis presents new methodology and algorithms that can be used to analyse and measure the hand tremor and fatigue of surgeons while performing surgery. This will assist them in deriving useful information about their fatigue levels, and make them aware of the changes in their tool point accuracies. This thesis proposes that muscular changes of surgeons, which occur through a day of operating, can be monitored using Electromyography (EMG) signals. The multi-channel EMG signals are measured at different muscles in the upper arm of surgeons. The dependence of EMG signals has been examined to test the hypothesis that EMG signals are coupled with and dependent on each other. The results demonstrated that EMG signals collected from different channels while mimicking an operating posture are independent. Consequently, single channel fatigue analysis has been performed. In measuring hand tremor, a new method for determining the maximum tremor amplitude using Principal Component Analysis (PCA) and a new technique to detrend acceleration signals using Empirical Mode Decomposition algorithm were introduced. This tremor determination method is more representative for surgeons and it is suggested as an alternative fatigue measure. This was combined with the complexity analysis method, and applied to surgically captured data to determine if operating has an effect on a surgeon’s fatigue and tremor levels. It was found that surgical tremor and fatigue are developed throughout a day of operating and that this could be determined based solely on their initial values. Finally, several Nonlinear AutoRegressive with eXogenous inputs (NARX) neural networks were evaluated. The results suggest that it is possible to monitor surgeon tremor variations during surgery from their EMG fatigue measurements.
Resumo:
In the case of surgical scalpels, blade retraction and disposability have been incorporated into a number of commercial designs to address sharps injury and infection transmission issues. Despite these new designs, the traditional metal reusable scalpel is still extensively used and this paper attempts to determine whether the introduction of safety features has compromised the ergonomics and so potentially the take-up of the newer designs. Examples of scalpels have been analysed to determine the ergonomic impact of these design changes. Trials and questionnaires were carried out using both clinical and non-clinical user groups, with the trials making use of assessment of incision quality, cutting force, electromyography and video monitoring. The results showed that ergonomic performance was altered by the design changes and that while these could be for the worse, the introduction of safety features could act as a catalyst to encourage re-evaluation of the ergonomic demands of a highly traditional product.
Resumo:
The aim of this work is to contribute to the analysis and characterization of training with whole body vibration (WBV) and the resultant neuromuscular response. WBV aims to mechanically activate muscle by eliciting stretch reflexes. Generally, surface electromyography is utilized to assess muscular response elicited by vibrations. However, EMG analysis could potentially bring to erroneous conclusions if not accurately filtered. Tiny and lightweight MEMS accelerometers were found helpful in monitoring muscle motion. Displacements were estimated integrating twice the acceleration data after gravity and small postural subject adjustments contribution removal. Results showed the relevant presence of motion artifacts on EMG recordings, the high correlation between muscle motion and EMG activity and how resonance frequencies and dumping factors depended on subject and his positioning onto the vibrating platform. Stimulations at the resonant frequency maximize muscles lengthening and in turn, muscle spindle solicitation , which may produce more muscle activation. Local mechanical stimulus characterization (Le, muscle motion analysis) could be meaningful in discovering proper muscle stimulation and may contribute to suggest appropriate and effective WBV exercise protocols. ©2009 IEEE.
Resumo:
Vibration treatment by oscillating platforms is more and more employed in the fields of exercise physiology and bone research. The rationale of this treatment is based on the neuromuscular system response elicited by vibration loads. surface Electromyography (EMG) is largely utilized to assess muscular response elicited by vibrations and Root Mean Square of the electromyography signals is often used as a concise quantitative index of muscle activity; in general, EMG envelope or RMS is expected to increase during vibration. However, it is well known that during surface bio-potential recording, motion artifacts may arise from relative motion between electrodes and skin and between skin layers. Also the only skin stretch, modifying the internal charge distribution, results in a variation of electrode potential. The aim of this study is to highlight the movements of muscles, and the succeeding relevance of motion artifacts on electrodes, in subjects undergoing vibration treatments. EMGs from quadriceps of fifteen subjects were recorded during vibration at different frequencies (15-40 Hz); Triaxial accelerometers were placed onto quadriceps, as close as possible to muscle belly, to monitor motion. The computed muscle belly displacements showed a peculiar behavior reflecting the mechanical properties of the structures involved. Motion artifact related to the impressed vibration have been recognized and related to movement of the soft tissues. In fact large artifacts are visible on EMGs and patellar electrodes recordings during vibration. Signals spectra also revealed sharp peaks corresponding to vibration frequency and its harmonics, in accordance with accelerometers data. © 2008 Springer-Verlag.
Resumo:
Older adults may have trouble when performing activities of daily living due to decrease in physical strength and degradation of neuromotor and musculoskeletal function. Motor activation patterns during Lateral Step Down and Step Up from 4-inch and 8-inch step heights was assessed in younger (n=8, 24.4 years) and older adults (n=8, 58.9 years) using joint angle kinematics and electromyography of lower extremity muscles. Ground reaction forces were used to ascertain the loading, stabilization and unloading phases of the tasks. Older adults had an altered muscle activation sequence and significantly longer muscle bursts during loading for the tibialis anterior, gastrocnemius, vastus medialis, bicep femoris, gluteus medius and gluteus maximus muscles of the stationary leg. They also demonstrated a significantly larger swing time (579.1 ms vs. 444.8 ms) during the step down task for the moving leg. The novel data suggests presence of age-related differences in motor coordination during lateral stepping.
Resumo:
Aim : To evaluate and to standardize surface electromyography (sEMG) normalization procedures for respiratory muscles by comparing muscle activation during Maximal Voluntary Isometric Contraction (MVIC) and Maximal Respiratory Pressures (MIP, MEP and sniff test). Methods: Healthy subjects were evalua ted regarding demographics, spirometry and sEMG during the five maneuvers: sniff test, MIP , MEP and Maximal Voluntary Isometric C ontraction (MVIC) of RA, SCM and SC A . For electrode placement, skin was prepared with abrasion, followed by shaving in the foll owing regions for acquisition of el ectromyographic signals: (1) SC M: lower third of the distance between the mastoid process and t he sternoclavicular joint; (2) SC A : 5 cm to the right from the sternoclavicular joint and at this point, up to 2 cm; and (3 ) RA: the level of umbilicus, 4 cm to the right. In electromyographic variables analysis , the data normality was assessed by Shapiro - Wilk test. Comparisons among studied maneuvers were performed by Friedman Test and Dunn’s post - hoc for multiple comparisons a mong inspiratory maneuvers, and Mann Whitney test for expiratory maneuvers. Subgroups differences between genders were performed by Student's t test or Mann - Whitney test according to data normality. Results: 35 subjects participated in the study, b ut 5 we re excluded (BMI> 25 kg/ m²). Sample consisted of 30 subjects (1 5 women), mean age 27.3±7.43 years, BMI 22.2 ± 1.69 kg/m² and spirometric indices within normal limits. Specific MVIC for SCM, SCA and RA showed the highest RMS. When we grouped sample into gender we found no difference among RMS values for the studied SCM maneuvers, while for SCA, MVIC SCM / SCA was the one with the highest RMS and for RA, MVIC RA in men. Once considering women, MVIC SCM/SCA showed the highest RMS for SCM, SCA and MVIC RA showed t he highest value for RA. Conclusion: MVIC for SCM, SCA and RA muscles showed the highest RMS values. When comparing RMS between the studied groups, there was no significant difference between men and women.
Resumo:
The classifier support vector machine is used in several problems in various areas of knowledge. Basically the method used in this classier is to end the hyperplane that maximizes the distance between the groups, to increase the generalization of the classifier. In this work, we treated some problems of binary classification of data obtained by electroencephalography (EEG) and electromyography (EMG) using Support Vector Machine with some complementary techniques, such as: Principal Component Analysis to identify the active regions of the brain, the periodogram method which is obtained by Fourier analysis to help discriminate between groups and Simple Moving Average to eliminate some of the existing noise in the data. It was developed two functions in the software R, for the realization of training tasks and classification. Also, it was proposed two weights systems and a summarized measure to help on deciding in classification of groups. The application of these techniques, weights and the summarized measure in the classier, showed quite satisfactory results, where the best results were an average rate of 95.31% to visual stimuli data, 100% of correct classification for epilepsy data and rates of 91.22% and 96.89% to object motion data for two subjects.