888 resultados para Edge detection method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microcystin-LR (MC-LR) is a dangerous toxin found in environmental waters, quantified by high performance liquid chromatography and/or enzyme-linked immunosorbent assays. Quick, low cost and on-site analysis is thus required to ensure human safety and wide screening programs. This work proposes label-free potentiometric sensors made of solid-contact electrodes coated with a surface imprinted polymer on the surface of Multi-Walled Carbon NanoTubes (CNTs) incorporated in a polyvinyl chloride membrane. The imprinting effect was checked by using non-imprinted materials. The MC-LR sensitive sensors were evaluated, characterized and applied successfully in spiked environmental waters. The presented method offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The formalin-Tween sedimentation method was compared with the formalin-ether sedimentation for parasitic detection. Of a total 297 fecal specimens examined, 72.1% were positive. The formalin-tween technique was effective for ascertaining helminths, particularly Ascaris lumbricoides, Trichuris trichiura and hookworm eggs; however it has less capability for protozoa detection. This method is simple, inexpensive, less time consuming and highly sensitive when detecting the parasitic infection, particularly when focusing on helminth eggs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: A new method for determining serum specific IgE (IMMULITE“ 2000 3gAllergy) has recently become available. Objective: To evaluate the clinical performance of IMMULITE 2000 in the diagnosis of cow’s milk allergy compared with that of UniCAP“. Additionally, we verified the behavior of both methods at two diagnostic decision points proposed by other authors. Methods: The study population consisted of 31 children with cow’s milk allergy (group A) and a control group of 19 atopic children without food allergy(group B). A blood sample from each child was tested using both methods and the results were compared. Results: In group A, the values for cow’s milk IgE ranged from 0.35 kU/L (the lowest common detection limit) to above 100 kU/L. In group B, the values were less than 1.1 kU/L for IMMULITE 2000 and less than 1.6 kU/L for UniCAP. An agreement of 90 % in IgE classes was obtained. Both methods demonstrated exactly the same diagnostic performance(sensitivity: 100 %; specificity: 78.9 %; negative predictive value: 100%; positive predictive value: 84.6%;efficiency: 90.2 %). The evaluation of the two methods at the two different decision points proposed in the literature showed a better positive predictive value with UniCAP, but we obtained equivalent performance with IMMULITE 2000 by choosing higher cutoff values. Conclusions: We conclude that IMMULITE 2000 is as effective as UniCAP in the diagnosis of cow’s milk allergy. Both methods can be used to obtain site-specific decision points that are population, age and disease dependent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cryptococcus neoformans detection was optimized using PCR technique with the objective of application in the clinical laboratory diagnosis. The amplification area was ITS and 5,6S which encodes the ribosomal RNA (rRNA). A total of 72 cerebrospinal fluid (CSF) samples were used, obtained from cases with and without AIDS. The patients had cryptococcal meningitis (n = 56) and meningitis caused by other agents (n = 16). The results demonstrated that PCR test had the highest sensitivity rates, superior to culture (85.7%) and to India ink test (76.8%). PCR was found to be sensitive in detecting 1 cell/mL and highly specific since it did not amplify other fungal DNA. The comparative analysis of the methods showed that PCR is more sensitive and specific and is applicable as an important laboratorial resource for neurocryptococcosis diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Twenty-four whole blood and serum samples were drawn from an eight year-old heart transplant child during a 36 months follow-up. EBV serology was positive for VCA-IgM and IgG, and negative for EBNA-IgG at the age of five years old when the child presented with signs and symptoms suggestive of acute infectious mononucleosis. After 14 months, serological parameters were: positive VCA-IgG, EBNA-IgG and negative VCA-IgM. This serological pattern has been maintained since then even during episodes suggestive of EBV reactivation. PCR amplified a specific DNA fragment from the EBV gp220 (detection limit of 100 viral copies). All twenty-four whole blood samples yielded positive results by PCR, while 12 out of 24 serum samples were positive. We aimed at analyzing whether detection of EBV-DNA in serum samples by PCR was associated with overt disease as stated by the need of antiviral treatment and hospitalization. Statistical analysis showed agreement between the two parameters evidenced by the Kappa test (value 0.750; p < 0.001). We concluded that detection of EBV-DNA in serum samples of immunosuppressed patients might be used as a laboratory marker of active EBV disease when a Real-Time PCR or another quantitative method is not available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oceans - San Diego, 2013

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Prolonged survival of patients under HAART has resulted in new demands for assisted reproductive technologies. HIV serodiscordant couples wish to make use of assisted reproduction techniques in order to avoid viral transmission to the partner or to the newborn. It is therefore essential to test the effectiveness of techniques aimed at reducing HIV and HCV loads in infected semen using molecular biology tests. METHODS: After seminal analysis, semen samples from 20 coinfected patients were submitted to cell fractioning and isolation of motile spermatozoa by density gradient centrifugation and swim-up. HIV and HCV RNA detection tests were performed with RNA obtained from sperm, seminal plasma and total semen. RESULTS: In pre-washing semen, HIV RNA was detected in 100% of total semen samples, whereas HCV RNA was concomitantly amplified in only one specimen. Neither HIV nor HCV were detected either in the swim-up or in the post-washing semen fractions. CONCLUSIONS: Reduction of HIV and/or HCV shedding in semen by density gradient centrifugation followed by swim-up is an efficient method. These findings lead us to believe that, although semen is rarely found to contain HCV, semen processing is highly beneficial for HIV/HCV coinfected individuals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The diagnosis of American cutaneous leishmaniasis (ACL) is frequently based on clinical and epidemiological data associated with the results of laboratory tests. Some laboratory methods are currently being applied for the diagnosis of ACL, among them the indirect immunofluorescence reaction (IIFR), the Montenegro skin test (MST), histopathological examination, and the polymerase chain reaction (PCR). The performance of these methods varies in a considerable proportion of patients. After the standardization of an immunoenzymatic test (ELISA) for the detection of IgG in the serum of patients with ACL using a crude Leishmania braziliensis antigen, the results obtained were compared to those of other tests routinely used for the diagnosis. The tests revealed the following sensitivity, when analyzed separately: 85% for ELISA IgG, 81% for PCR, 64.4% for MST, 58.1% for IIFR, and 34% for the presence of parasites in the biopsy. ELISA was positive in 75% of patients with ACL presenting a negative MST, in 84.8% of ACL patients with negative skin or mucous biopsies for the presence of the parasite, and in 100% of cases with a negative PCR. Thus, ELISA presented a higher sensitivity than the other tests and was useful as a complementary method for the diagnosis of ACL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Progressive disseminated histoplasmosis (PDH) is an increasingly common cause of infection in patients with acquired immune deficiency syndrome (AIDS). We report 21 cases of PDH associated with AIDS diagnosed by lysis-centrifugation blood culture method. The most prevalent clinical findings were fever, weight loss, respiratory symptoms, and mucocutaneous lesions. Chest roentgenogram showed diffuse pulmonary infiltrates in 13 of 21 patients (62%). Brochoalveolar fluid has yelded positive culture in four patients only in medium with cycloheximide.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An "in-house" RT-PCR method was developed that allows the simultaneous detection of the RNA of the Hepatitis C Virus (HCV) and an artificial RNA employed as an external control. Samples were analyzed in pools of 6-12 donations, each donation included in two pools, one horizontal and one vertical, permitting the immediate identification of a reactive donation, obviating the need for pool dismembering. The whole process took 6-8 hours per day and results were issued in parallel to serology. The method was shown to detect all six HCV genotypes and a sensitivity of 500 IU/mL was achieved (95% hit rate). Until July 2005, 139,678 donations were tested and 315 (0.23%) were found reactive for HCV-RNA. Except for five false-positives, all 310 presented the corresponding antibody as well, so the yield of NAT-only donations was zero, presenting a specificity of 99.83%. Detection of a window period donation, in the population studied, will probably demand testing of a larger number of donations. International experience is showing a rate of 1:200,000 - 1:500,000 of isolated HCV-RNA reactive donations.