1000 resultados para Double-émulsion
Resumo:
A new ECTT-DHPT with InGaAsP(lambda=1.55 mu m) as base and InGaAsP(lambda=1.3 mu m) as collector as well as waveguide was designed and fabricated, the DC characteristics reveal that the ECTT-DRPT can perform good optoelectronic mix operation and linear amplification operation by optically biased at two appropriate value respectively. Responsivity of more than 52A/W and dark current of 70nA (when V-ce=1V) were obtained.
Resumo:
We report a new technique, called SAP, for side pumping of double-clad, rare-earth-doped fiber lasers using fiber-coupled pump sources. The highest coupling efficiency can even exceed 92% in theory with this structure.
Resumo:
An analytic method is used to study the reflection and transmission coefficients of the double submerged rectangular blocks (DSRBs) in oblique waves.. The scattering potentials are obtained by means of the eigenfunction expansion method, and expressions for the reflection and transmission coefficients are determined. The boundary element method is employed to verify the correctness of the present analytical method. The DSRBs have better performance than the single submerged rectangular block (SSRB) in certain cases. The reflection and transmission properties of the DSRBs are investigated for some specific cases, and the influences of the geometric parameters are also presented.
Resumo:
It is predicted that large and opposite generalized Goos-Hanchen (GGH) shifts may occur simultaneously for TE and TM light beams upon reflection from an asymmetric double-prism configuration when the angle of incidence is below but near the critical angle for total reflection, which may lead to interesting applications in optical devices and integrated optics. Numerical simulations show that the magnitude of the GGH shift can be of the order of beam's width.
Resumo:
We present a novel X-ray frame camera with variable exposure time that is based on double-gated micro-channel plates (MCP). Two MCPs are connected so that their channels form a Chevron-MCP structure, and four parallel micro-strip lines (MSLs) are deposited on each surface of the Chevron-MCP. The MSLs on opposing surfaces of the Chevron-MCP are oriented normal to each other and subjected to high voltage. The MSLs on the input and output surfaces are fed high voltage pulses to form a gating action. In forming two-dimensional images, modifying the width of the gating pulse serves to set exposure times (ranging from ps to ms) and modifying the delay between each gating pulse serves to set capture times. This prototype provides a new tool for high-speed X-ray imaging, and this paper presents both simulations and experimental results obtained with the camera.
Resumo:
A novel type of interferometer, the moving-mirror-pair interferometer, is presented, and its principle and properties are studied. The new interferometer is built with three flat mirrors, which include two flat moving mirrors fixed as a single moving part by a rigid structure and one flat fixed mirror. The optical path difference (OPD) is obtained by the straight reciprocating motion of the double moving mirror, and the OPD value is four times the physical shift value of the double moving mirror. The tilt tolerance of the double moving mirror of the novel interferometer is systematically analyzed by means of modulation depth and phase error. Where the square aperture is concerned, the formulas of the tilt tolerance were derived. Due to the novel interferometer's large OPD value and low cost, it is very applicable to the high-spectral-resolution Fourier-transform spectrometers for any wavenumber region from the far infrared to the ultraviolet. (C) 2008 Optical Society of America.