806 resultados para Difference logic
Electroacupuncture analgesia in dogs: is there a difference between uni- and bi-lateral stimulation?
Resumo:
Objective To compare the analgesic effect of uni- and bi-lateral electroacupuncture (EA) in response to thermal and mechanical nociceptive stimuli and to investigate the cardiorespiratory, endocrine, and behavioral changes in dogs submitted to EA.Study design Prospective, randomized cross-over experimental study.Animals Eight adult, clinically healthy, cross-breed dogs, weighing 13 +/- 4 kg.Methods Dogs underwent electrostimulation at false acupoints (T-false); bilateral EA at acupoints, stomach 36, gall bladder 34 and spleen 6 (T-EA/bil); unilateral EA at the same points (T-EA/uni) or were untreated (T-control). All animals received acepromazine (0.05 mg kg(-1)) IV; and heart rate, pulse oximetry, indirect arterial blood pressure, respiratory rate, PECO2, rectal temperature, and plasma cortisol concentration were measured before, during, and after EA. Analgesia was tested using thoracic and abdominal cutaneous thermal and mechanical stimuli, and an interdigital thermal stimulus. Behavior was classified as calm or restless. Analysis of variance for repeated measures followed by Tukey's test was used for analysis of the data.Results There were no cardiorespiratory differences among the treatments. The cutaneous pain threshold was higher after EA, compared with false points. The latency period was shorter and analgesia was more intense in T-EA/bil than T-EA/uni, when both were compared with T-false and T-control. Six out of eight animals treated with EA were calm during treatment, and 5/8 and 4/8 of the T-false and T-control animals, respectively, were restless. Latency to interdigital thermal stimulation increased in T-EA/bil compared with the others. There was no difference in plasma cortisol concentrations among the treatments.Conclusions Bilateral EA produced a shorter latency period, a greater intensity, and longer duration of analgesia than unilateral stimulation, without stimulating a stress response.Clinical relevance Bilateral EA produces a better analgesic effect than unilateral EA.
Resumo:
We suggest a pseudospectral method for solving the three-dimensional time-dependent Gross-Pitaevskii (GP) equation, and use it to study the resonance dynamics of a trapped Bose-Einstein condensate induced by a periodic variation in the atomic scattering length. When the frequency of oscillation of the scattering length is an even multiple of one of the trapping frequencies along the x, y or z direction, the corresponding size of the condensate executes resonant oscillation. Using the concept of the differentiation matrix, the partial-differential GP equation is reduced to a set of coupled ordinary differential equations, which is solved by a fourth-order adaptive step-size control Runge-Kutta method. The pseudospectral method is contrasted with the finite-difference method for the same problem, where the time evolution is performed by the Crank-Nicholson algorithm. The latter method is illustrated to be more suitable for a three-dimensional standing-wave optical-lattice trapping potential.
Resumo:
We combine the D0 measurement of the width difference between the light and heavy B-s(0) mass eigenstates and of the CP-violating mixing phase determined from the time-dependent angular distributions in the B-s(0)-> J/psi phi decays along with the charge asymmetry in semileptonic decays also measured with the D0 detector. With the additional constraint from the world average of the flavor-specific B-s(0) lifetime, we obtain Delta Gamma(s)equivalent to(Gamma(L)-Gamma(H))=0.13 +/- 0.09 ps(-1) and vertical bar phi(s)vertical bar=0.70(-0.47)(+0.39) or Delta Gamma(s)=-0.13 +/- 0.09 ps(-1) and vertical bar phi(s)vertical bar=2.44(-0.39)(+0.47). The data sample corresponds to an integrated luminosity of 1.1 fb(-1) accumulated with the D0 detector at the Fermilab Tevatron Collider.
Resumo:
We present a study of the decay B-s(0)-> J/psi phi. We obtain the CP-odd fraction in the final state at time zero R-perpendicular to = 0.16 +/- 0.10 (stat) +/- 0.02(syst), the average lifetime of the (B-s(0), (B) over bar (0)(s)) system, (tau) over bar (B-s(0)) = 1.39(-0.16)(+0.13)(stat)(-0.02)(+0.01)(syst) ps, and the relative width difference between the heavy and light mass eigen-states, Delta Gamma/(Gamma) over bar = (Gamma(L) - Gamma(H))/(Gamma) over bar = 0.24(-0.38)(+0.28)(stat)(-0.04)(+0.03)(syst). With the additional constraint from the world average of the B-s(0) lifetime measurements using semileptonic decays, we find (tau) over bar (B-s(0)) = 1.39 +/- 0.06 ps and Delta Gamma/(Gamma) over bar = 0.25(-0.15)(+0.14). For the ratio of the B-s(0) and B-0 lifetimes we obtain (tau) over bar (B-s(0))/tau(B-s(0)) = 0.91 +/- 0.09(stat) +/- 0.003(syst).
Resumo:
From an analysis of the decay B-s(0)-> J/psi phi, we obtain the width difference between the light and heavy mass eigenstates Delta Gamma equivalent to(Gamma(L)-Gamma(H))=0.17 +/- 0.09(stat)+/- 0.02(syst) ps(-1) and the CP-violating phase phi(s)=-0.79 +/- 0.56(stat)(-0.01)(+0.14)(syst). Under the hypothesis of no CP violation (phi(s)equivalent to 0), we obtain 1/Gamma=tau/(B-s(0))=1.52 +/- 0.08(stat)(-0.03)(+0.01)(syst) ps and Delta Gamma=0.12(-0.10)(+0.08)(stat)+/- 0.02(syst) ps(-1). The data sample corresponds to an integrated luminosity of about 1.1 fb(-1) accumulated with the D0 detector at the Fermilab Tevatron collider. This is the first direct measurement of the CP-violating mixing phase in the B-s(0) system.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The crossflow filtration process differs of the conventional filtration by presenting the circulation flow tangentially to the filtration surface. The conventional mathematical models used to represent the process have some limitations in relation to the identification and generalization of the system behavior. In this paper, a system based on fuzzy logic systems is developed to overcome the problems usually found in the conventional mathematical models. Imprecisions and uncertainties associated with the measurements made on the system are automatically incorporated in the fuzzy approach. Simulation results are presented to justify the validity of the proposed approach.
Resumo:
Variance dispersion graphs have become a popular tool in aiding the choice of a response surface design. Often differences in response from some particular point, such as the expected position of the optimum or standard operating conditions, are more important than the response itself. We describe two examples from food technology. In the first, an experiment was conducted to find the levels of three factors which optimized the yield of valuable products enzymatically synthesized from sugars and to discover how the yield changed as the levels of the factors were changed from the optimum. In the second example, an experiment was conducted on a mixing process for pastry dough to discover how three factors affected a number of properties of the pastry, with a view to using these factors to control the process. We introduce the difference variance dispersion graph (DVDG) to help in the choice of a design in these circumstances. The DVDG for blocked designs is developed and the examples are used to show how the DVDG can be used in practice. In both examples a design was chosen by using the DVDG, as well as other properties, and the experiments were conducted and produced results that were useful to the experimenters. In both cases the conclusions were drawn partly by comparing responses at different points on the response surface.
Resumo:
It can be observed that the number and the complexity of the application's domains, where the Paraconsistent Annotated Logic has been used, have grown a lot in the last decade. This increase in the complexity of the application's domain is an extra challenge for the designers of such systems, once there are not suitable computer hardware to run paraconsistent systems. This work proposes a new hardware architecture for the building Paraconsistent system.
Resumo:
Paracoccidioides brasiliensis causes infection by the host inhalation of airborne propagules of the mycelia phase of the fungus. These particles reach the lungs, and disseminate to virtually all organs. Here we describe the identification of differentially expressed genes in studies of host-fungus interaction. We analyzed two cDNA populations of P. brasiliensis, one obtained from infected animals and the other an admixture of fungus and human blood thus mimicking the hematologic events of the fungal dissemination. Our analysis identified transcripts differentially expressed. Genes related to iron acquisition, melanin synthesis and cell defense were specially upregulated in the mouse model of infection. The upregulated transcripts of yeast cells during incubation with human blood were those predominantly related to cell wall remodeling/synthesis. The expression pattern of genes was independently confirmed in host conditions, revealing their potential role in the infection process. This work can facilitate functional studies of novel regulated genes that may be important for the survival and growth strategies of P. brasiliensis in humans. (c) 2006 Elsevier Masson SAS. All rights reserved.
Resumo:
Biochemical computing is an emerging field of unconventional computing that attempts to process information with biomolecules and biological objects using digital logic. In this work we survey filtering in general, in biochemical computing, and summarize the experimental realization of an and logic gate with sigmoid response in one of the inputs. The logic gate is realized with electrode-immobilized glucose-6-phosphate dehydrogenase enzyme that catalyzes a reaction corresponding to the Boolean and functions. A kinetic model is also developed and used to evaluate the extent to which the performance of the experimentally realized logic gate is close to optimal.