874 resultados para Determination of law
Resumo:
This study shows the possibility offered by modern ultra-high performance supercritical fluid chromatography combined with tandem mass spectrometry in doping control analysis. A high throughput screening method was developed for 100 substances belonging to the challenging classes of anabolic agents, hormones and metabolic modulators, synthetic cannabinoids and glucocorticoids, which should be detected at low concentrations in urine. To selectively extract these doping agents from urine, a supported liquid extraction procedure was implemented in a 48-well plate format. At the tested concentration levels ranging from 0.5 to 5 ng/mL, the recoveries were better than 70% for 48-68% of the compounds and higher than 50% for 83-87% of the tested substances. Due to the numerous interferences related to isomers of steroids and ions produced by the loss of water in the electrospray source, the choice of SFC separation conditions was very challenging. After careful optimization, a Diol stationary phase was employed. The total analysis time for the screening assay was only 8 min, and interferences as well as susceptibility to matrix effect (ME) were minimized. With the developed method, about 70% of the compounds had relative ME within the range ±20%, at a concentration of 1 and 5 ng/mL. Finally, limits of detection achieved with the above-described strategy including 5-fold preconcentration were below 0.1 ng/mL for the majority of the tested compounds. Therefore, LODs were systematically better than the minimum required performance levels established by the World anti-doping agency, except for very few metabolites.
Resumo:
PURPOSE: This study aims to identify which aspects of the pupil light reflex are most influenced by rods and cones independently by analyzing pupil recordings from different mouse models of photoreceptor deficiency. METHODS: One-month-old wild type (WT), rodless (Rho-/-), coneless (Cnga3-/-), or photoreceptor less (Cnga3-/-; Rho-/- or Gnat1-/-) mice were subjected to brief red and blue light stimuli of increasing intensity. To describe the initial dynamic response to light, the maximal pupillary constriction amplitudes and the derivative curve of the first 3 seconds were determined. To estimate the postillumination phase, the constriction amplitude at 9.5 seconds after light termination was related to the maximal constriction amplitude. RESULTS: Rho-/- mice showed decreased constriction amplitude but more prolonged pupilloconstriction to all blue and red light stimuli compared to wild type mice. Cnga3-/- mice had constriction amplitudes similar to WT however following maximal constriction, the early and rapid dilation to low intensity blue light was decreased. To high intensity blue light, the Cnga3-/- mice demonstrated marked prolongation of the pupillary constriction. Cnga3-/-; Rho-/- mice had no pupil response to red light of low and medium intensity. CONCLUSIONS: From specific gene defective mouse models which selectively voided the rod or cone function, we determined that mouse rod photoreceptors are highly contributing to the pupil response to blue light stimuli but also to low and medium red stimuli. We also observed that cone cells mainly drive the partial rapid dilation of the initial response to low blue light stimuli. Thus photoreceptor dysfunction can be derived from chromatic pupillometry in mouse models.
Resumo:
X-This work shows an alternative method to copper determination by X-Ray Fluorescence (XRF). Since copper concentration in natural waters is not enough to reach XRF detection limit, a liquid-solid preconcentration procedure was proposed. Glycerin was used to complex the metal increasing its adsorption on activated charcoal. The solid phase was used to XRF determination. Several parameters were evaluated, such as, the complexation pH, the charcoal adsorption limit and the glycerin concentration. The interferences are lead and bismuth and the sensitivities decreased in the order Cu2+, Bi3+ and Pb2+. The advantages of the method are its simplicity, low cost and low spectral interference.
Resumo:
The strength properties of paper coating layer are very important in converting and printing operations. Too great or low strength of the coating can affect several problems in printing. One of the problems caused by the strength of coating is the cracking at the fold. After printing the paper is folded to final form and the pages are stapled together. In folding the paper coating can crack causing aesthetic damage over printed image or in the worst case the centre sheet can fall off in stapling. When folding the paper other side undergoes tensile stresses and the other side compressive stresses. If the difference between these stresses is too high, the coating can crack on the folding. To better predict and prevent cracking at the fold it is good to know the strength properties of coating layer. It has measured earlier the tensile strength of coating layer but not the compressive strength. In this study it was tried to find some way to measure the compressive strength of the coating layer and investigate how different coatings behave in compression. It was used the short span crush test, which is used to measure the in-plane compressive strength of paperboards, to measure the compressive strength of the coating layer. In this method the free span of the specimen is very small which prevent buckling. It was measured the compressive strength of free coating films as well as coated paper. It was also measured the tensile strength and the Bendtsen air permeance of the coating film. The results showed that the shape of pigment has a great effect to the strength of coating. Platy pigment gave much better strength than round or needle-like pigment. On the other hand calcined kaolin, which is also platy but the particles are aggregated, decreased the strength substantially. The difference in the strength can be explained with packing of the particles which is affecting to the porosity and thus to the strength. The platy kaolin packs up much better than others and creates less porous structure. The results also showed that the binder properties have a great effect to the compressive strength of coating layer. The amount of latex and the glass transition temperature, Tg, affect to the strength. As the amount of latex is increasing, the strength of coating is increasing also. Larger amount of latex is binding the pigment particles better together and decreasing the porosity. Compressive strength was increasing when the Tg was increasing because the hard latex gives a stiffer and less elastic film than soft latex.
Resumo:
This work presents a comparison between three analytical methods developed for the simultaneous determination of eight quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, sarafloxacin, oxolinic acid and flumequine) in pig muscle, using liquid chromatography with fluorescence detection (LC-FD), liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The procedures involve an extraction of the quinolones from the tissues, a step for clean-up and preconcentration of the analytes by solid-phase extraction and a subsequent liquid chromatographic analysis. The limits of detection of the methods ranged from 0.1 to 2.1 ng g−1 using LC-FD, from 0.3 to 1.8 using LC-MS and from 0.2 to 0.3 using LC-MS/MS, while inter- and intra-day variability was under 15 % in all cases. Most of those data are notably lower than the maximum residue limits established by the European Union for quinolones in pig tissues. The methods have been applied for the determination of quinolones in six different commercial pig muscle samples purchased in different supermarkets located in the city of Granada (south-east Spain).
Resumo:
The present study reports details of the stoichiometric characterization of the mixed complex system, V(H2O2)PAR, formed when vanadium adequately reacts with hydrogen peroxide and with 4-(2-Pyridilazo)Resorcinol. Also the presence of polynuclear species was investigated in order to elucidate about unambiguous assignment of the molar absorptivity, stability constant and composition of the complex. Two mathematical treatments methods of the experimental results were employed. From the results it can be concluded that this system corresponds to a mononuclear complex with 1:1:1 stoichiometry.
Resumo:
A spectrofluorometric method has been developed and validated for the determination of gemfibrozil. The method is based on the excitation and emission capacities of gemfibrozil with excitation and emission wavelengths of 276 and 304 nm respectively. This method allows de determination of the drug in a self-nanoemulsifying drug delivery system (SNEDDS) for improve its intestinal absorption. Results obtained showed linear relationships with good correlation coefficients (r(2)>0.999) and low limits of detection and quantification (LOD of 0.075 μg mL(-1) and LOQ of 0.226 μg mL(-1)) in the range of 0.2-5 μg mL(-1), equally this method showed a good robustness and stability. Thus the amounts of gemfibrozil released from SNEDDS contained in gastro resistant hard gelatine capsules were analysed, and release studies could be performed satisfactorily.
Resumo:
A new method has been developed for determining the content of mixtures of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), the HMX/RDX ratio, in explosive compositions by Fourier transform infrared spectroscopy (FT-IR), in the regions MIR (mid infrared) and NIR (near infrared) with reference values obtained by chromatographic analysis (HPLC). Plots of relative MIR (A917 / A783) or NIR absorbance values (A4412 / A4317) versus HMX/RDX ratio determined by HPLC analysis revealed good linear relationships.
Resumo:
A rapid and sensitive method is described for the determination of clofentezine residues in apple, papaya, mango and orange. The procedure is based on the extraction of the sample with a hexane:ethyl acetate mixture (1:1, v/v) and liquid chromatographic analysis using UV detection. Mean recoveries from 4 replicates of fortified fruit samples ranged from 81% to 96%, with coefficients of variation from 8.9% to 12.5%. The detection and quantification limits of the method were of 0.05 and 0.1 mg kg-1, respectively.
Resumo:
Two high performance liquid chromatography (HPLC) methods for the quantitative determination of indinavir sulfate were tested, validated and statistically compared. Assays were carried out using as mobile phases mixtures of dibutylammonium phosphate buffer pH 6.5 and acetonitrile (55:45) at 1 mL/min or citrate buffer pH 5 and acetonitrile (60:40) at 1 mL/min, an octylsilane column (RP-8) and a UV spectrophotometric detector at 260 nm. Both methods showed good sensitivity, linearity, precision and accuracy. The statistical analysis using the t-student test for the determination of indinavir sulfate raw material and capsules indicated no statistically significant difference between the two methods.
Resumo:
A simple and rapid precipitation titration method was developed and validated to determine sulfate ion content in indinavir sulfate raw material. 0.1 mol L-1 lead nitrate volumetric solution was used as titrant employing potentiometric endpoint determination using a lead-specific electrode. The United States Pharmacopoeia Forum indicates a potentiometric method for sulfate ion quantitation using 0.1 mol L-1 lead perchlorate as titrant. Both methods were validated concerning linearity, precision and accuracy, yielding good results. The sulfate ion content found by the two validated methods was compared by the statistical t-student test, indicating that there was no statistically significant difference between the methods.
Resumo:
Zidovudine (AZT) and stavudine (D4T) are nucleoside reverse transcriptase inhibitors extensively used in human immunodeficiency virus (HIV) infected patients. In order to evaluate the quality of these drugs, two stability indicating HPLC methods were developed. The validated methods were applied in quantitative determination of AZT, D4T and their induced degradation products in capsule preparations. The stability studies were conducted at controlled temperature and relative humidity conditions based on the International Conference on Harmonization stability studies protocol for Zone IV areas. Easy sample preparation and low-cost make these methods especially useful for quality control and stability studies of AZT and D4T in drug products.
Resumo:
A method is proposed for the determination of the moisture content of aromatic plants. This method is based on the co-distillation of the starting material in a modified Clevenger apparatus with four organic solvents (toluene, cyclohexane, dichloromethane and carbon tetrachloride). The results were compared with those obtained by oven drying at 105 ºC and steam distillation of the essential oil. The efficiencies of the methods were shown to be equivalent. The solvent distillation method was more practical, especially with respect to operating time (2 h).
Resumo:
An analytical study based on extraction with acetonitrile-water, immunoaffinity column cleanup, and HPLC/fluorescence detection for separation and identification of ochratoxin A in coriander was carried out. Validation of the applied methodology was done through accuracy and precision studies. Homogenized samples of coriander were spiked in triplicate with ochratoxin A at 0.5, 1.0, 2.0, and 5.0 µg/kg levels. Recovery values were in the range of 98% for a fortification level at 0.5 µg/kg to 109.1% at 1.0 µg/kg. Application to coriander samples available in Portuguese markes showed no contamination with ochratoxin A.
Resumo:
Worldwide cultivation of corn is expanding, due in part to the increasing production of bioethanol. In consequence, huge amounts of corn stalks residues are been produced. Instead of incineration, we transformed the corn stalks into a semichemical pulp and successfully applied it as reinforcement in polypropylene composites. PP composites reinforced with 40% wt corn stalk single fibers were prepared, and their mechanical properties were evaluated. Through mechanical properties modeling of the composites, the intrinsic tensile strength of the cellulosic fibers that constitute the corn stalk have been determined