610 resultados para Corrosão eletroquímica


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The contamination of underground waters is a subject of great importance, since a lot of people use this kind of source for public supply. This paperwork manages with how gas stations can contaminate these waters and what are some remediation techniques, used nowadays to solve this problem. The contamination caused by the gas stations can have its origin in the underground storage tanks when they suffer corrosion and show leaking problems. It’s a topic of great relevance, because the hydrocarbons derivated from petroleum present in the fuels can stay for a long time in the environment. Besides that, an analyses of the risk of contamination by gas stations in the city of Rio Claro was made based on three parameters: density of the gas stations, depth of the underground water and hydraulic conductivity. To achieve such goal, maps were elaborated considering those parameters individually and considering the three of them together. Analyzing those maps, it was concluded see that the spots that represent the biggest risks of contamination in Rio Claro are located southeast and center-west.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Há uma grande expectativa para o desenvolvimento de biossensores miniaturizados, que permitam análises mais eficientes e rápidas, em matrizes complexas como as encontradas: no ar, alimentos, águas residuais e em medicamentos. Recentemente, filmes poliméricos inteligentes ativados por estímulo externo têm atraído bastante interesse no desenvolvimento desses tais nanosensores para uso em sistemas químicos e bioquímicos. Estes materiais apresentam uma alta sensibilidade a alterações físicas ou químicas ocorridas na sua interface, e respondem seletivamente a essas mudanças para se adaptarem ao meio. Juntando-se as propriedades estímulo-responsivas desses polímeros com a alta seletividade de reações biológicas tem-se uma excelente combinação para a criação de nano biossensores. A esse tipo de sistema: interfaces/material biológico adota-se a nomenclatura biointerface. As biointerfaces são biossensores em potencial, e na preparação dos biossensores a tarefa mais complicada na sua preparação é o desenvolvimento de superfícies adequadas para o interfaceamento com material biológico, de maneira que a parte biológica possa atuar de forma sensível e estável. A primeira etapa consistiu na produção e caracterização dos polímeros escova (P2VP), os quais serão preparados pelo processo de deposição térmica. A caracterização dos mesmos foi realizada por imagens microscopia de força atômica (AFM), via eletroquímica e por transmissão de ressonância plasmônica de superfície. Na etapa posterior foi estudada a imobilização da glicose oxidase para a preparação do biossensor. O dispositivo fabricado foi empregado para a determinação direta de glicose. Desta forma, esperou-se obter uma metodologia de menor custo e tempo de análise. Logo, este estudo irá contribuir de forma significativa sobre os processos de montagem de biossensores a partir de compostos nanoestruturados. Foram utilizadas técnicas de ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The search for materials with higher properties and characteristics (wear resistance, oxidation, corrosion, etc.) has driven research of various materials. Among the materials that are being studied with such properties and characteristics are super alloys based on nickel which has an important role in the aeronautical, automotive, marine, production of gas turbines and now in space vehicles, rocket engineering , experimental aircraft, nuclear reactors, steam-powered plants, petrochemical and many other applications because besides having all the characteristics and properties mentioned above also have an excellent performance at high temperatures. The super alloy based on nickel studied in this work is the super alloy Pyromet 31v normally used in the manufacture of exhaust valves in common engines and diesel engines of high power by cater requirements such as mechanical strength and corrosion resistance at temperatures of approximately 815 ° C. The objective of this work is to produce results to demonstrate more specific information about the real influence of coatings on cutting tools and cutting fluids in turning and thus promote the optimization of the machining of these alloys. The super alloy Pyromet 31v was processed through turning, being performed with various machining parameters such as cutting speed, feed rate, depth in conditions of Minimum Amount of Fluid (MAF), abundant fluid, cutting tools with coating and without coating in early in his work life and with wear. After turning were obtained several samples of chips and the part generated during the machining process, was measured roughness of the material, subsequently made macrostructural analysis of the tools used order to detect possible wear and microstructural analysis of samples collected being that the latter was used for Optical Microscopy, Scanning Electron Microscopy (SEM) and ... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Silver nanoparticles (Ag) were deposited on multi-walled carbon nanotube by eletroless. The hybrid Ag/MWCNT was used in the modification of glassy carbon electrode (GC) surface. The electrochemical characterization confirmed the presence of Ag in the nanocomposite has been showed that the synthesis was successful. The GC electrode modified with Ag/MWCNT film was evaluated for electro-oxidation of benzene. The electrochemical behavior presented an improvement on the catalytic surface in relation to non-modified GC electrode. The anodic peak current increased the magnitude in three times when compared with the CG electrode modified only with MWCNT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The glassy carbon is a material with a huge technological evolution. Due to its lightness, biocompatibility and their thermal and electrical properties this material finds applications in several industrial fields such as electronics, medical, aerospace and chemical. In order to explore the conductive properties of glassy carbon for use as modified electrodes, the present work aims the processing of monolithic and reticulated glassy carbon with colloidal copper for use in electrochemical applications. First, the best parameters for the cure of furfuryl alcohol resin doped were established through viscosimetry measurements and pressurized differential scanning calorimetry. The analysis of the micrographs of the cured resins show that copper concentrations above 3% weight, generate higher porosity in the material. The characterizations of the monolithic and reticulated glassy carbon resulting from carbonization were performed by scanning electron microscopy (SEM), Raman and Electrochemical impedance spectroscopy, and although it was not possible to detect the presence of copper by SEM, the influence of these particles have been observed by Raman and FT-IR spectra and electrochemical behavior of the material. The decrease in conductivity of monolithic and reticulated glassy carbon in the presence of copper may be related to the defects caused by the presence of copper in the structure of the material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In engineering, for correct designing the structural components required for cyclical stresses, it is necessary to determine a limit of resistance to fatigue, which is the maximum amplitude of the applied tension under which the fatigue failure does not occurs after a certain number cycles. The marine environment is hostile, not only by the high pressure, corrosion, but also by low temperatures. Petrol Production units, composed of the risers (pipelines connecting the oil well to the ship), are dimensioned to remain installed for periods of 20 up to 30 years, and must therefore be prepared to support various efforts, such as tidal, wind currents and everything that is related. This paper focuses on a study on the fatigue behavior of microalloyed steel, API 5L Grade X70, used to transport oil and gas by pipelines. For analysis, we obtained the curves S-N (stress vs. number of cycles) using laboratory data collected from cylindrical longitudinal and transverse specimens used in axial fatigue test in accordance with ASTM E466. The tensile tests and microhardness were performed to characterize the mechanical properties of the samples, and it was found that the values meet the specifications of the standard API 5L. To characterize microstructurally the material, it was also made a metallographic analysis of the steel under study, and the origin of the fatigue crack was investigated with the support of a scanning electron microscope (SEM).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The non-ferrous materials have got so many mechanical, physical and chemical advantageous properties so that is provided to them consolidated position in industry. In this context, aluminium alloys have been seen a lot on many applications of engineering areas – specially on automotive, aeronautical and aerospace due to their main properties such as low density, high corrosion resistance, favorable structure weight / material resistance relation, among others characteristics that are mencioned through this study. This study aims to analyze the aluminium alloys behavior on a general context when they are used on turning process, taking for examples the 6262 and 7050 aluminium alloys. In this way, the analysis studies the datas obtained during the turning tests realized on 3 steps each one; those datas are concerning the medium and total rugosities – obtained with the assistance of a portable Surface Roughness Finish Tester, as well as the chips obtained during the tests - visual analysis, and the cutting tools wear – with the assistance of an optical microscope, under different conditions of application of cutting fluids (dry machining, application of coolant in abundance and MQL – Minimum Quantity of Lubricant). The results concerning this study show detailed information about influence of cutting fluids on the machining by turning of the aluminium alloys related on this work and also about aluminium alloys in general when they are used on turning processes with different conditions from one another. By this way, it was evident the MQL technique is the best one for the 6262 alloy. However, for 7050 alloy, it was evident that the dry machining is responsible for the best results

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In view of the need to develop a device for security and lateral protection, due to the Resolution 323/09 of CONTRAN, which requires the use of such equipment for most trucks and tow trucks, the objective of this work is to develop a project for an aluminum lateral protection device, according to the ABNT NBR 14.148 regulation, that, among many specifications, stipulates that the equipment must support a load of 5 kN and suffer a maximum deflection of 30mm, but does not say what material it should be made of. The reason for choosing aluminum is because of its low density, so as not to significantly increase the curb weight of the truck, which, consequently, reduces CO2 emissions and maintenance expenses. Additionally, this material presents a good resistance/weight ratio, high resistance to corrosion, excellent surface finish and it's fully recyclable; reason why it has been gaining the attention of many industry segments. For the realization of the project, profiles were chosen to make the assembly of the set, and then a finite elements analysis was performed in the HyperWorks software, to verify if the designed device would support the loads stipulated by the regulation. One details to note is that these simulation programs could show inaccuracies, because of the size and shape of the elements that compose the mesh, and for many other reasons, so it is necessary that, even with the results coming back satisfactory, actual physical tests are conducted to validate the proper functioning of the equipment, which was not done for this study

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a study on the development of a manufacturing system of printed circuit boards through copper milling. An advantage of this system is the replacement of chemical processes by physical process presenting a sustainable solution. The paper uses programs that will generate G-code needed to establish the coordinates where the milling forms the tracks. After obtaining the code, it will be transformed into steps that will be sent through the serial port to the microcontroller and the serial communication control will be in software. After obtaining information the microcontroller will execute the movement of the stepper motors through their drivers, H-bridge, the microcontroller also drives the spindle motor responsible for rotating the grinding tool, using a driver with a optocoupler and TRIAC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titanium and its alloys have been used for biomedical applications due their excellent properties such as high corrosion resistance, biocompatibility and mechanical properites. In this study, microstructural and mechanical properties of Ti-30Ta alloy was evaluated during its processing. Ti-30Ta alloy ingots were produced from sheets of commercially pure titanium (99.9%) and tantalum (99.9%). Its melting was realized in arc melting furnace in an argon atmosphere. After homogenizing at 1200ºC, ingots were cold worked by swaging. Samples with 13 mm in diameter were obtained. They were forging at the reduction ratios of 15%. After deformation, microstructure was evaluated by optical microscopy in each condition. Also, Vickers microhardness of samples was measured and phase constitution was evaluated using XRD analysis

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of technology for structural composites has as one of its ends form a set of materials that combine high values of mechanical strength and stiffness and low density. Today, companies like Embraer and PETROBRAS and research institutions like NASA, working with these materials with recognized advantages in terms of weight gain, increased performance and low corrosion. We have developed a systematic study to determine the bond strength between composite carbon fiber / epoxy and fiberglass / epoxy laminate both bonded to a carbon steel which are widely used in the petrochemical industry and repair. For morphological evaluation and bonding between materials of different natures, ultrasound analysis, optical microscopy and stereoscopy were performed. To simulate actual conditions, the composites were subjected to conditioning by using heat shock temperatures from -50 to 80 ° C for 1000 cycles for composite carbon fiber / epoxy composites and 2000 cycles for fiberglass / epoxy . The use of composites studied here proved to be efficient to perform repairs in metallic pipes with application petrochemical, as when exposed to sudden changes of temperature (-50 ° to 80 ° C) cycling at 1000 to 2000 times, its mechanical properties (shear and tensile) practically do not change

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Being the corrosion one of the great problems facing the industry today, specifically the internal corrosion of pipes in chemical and petrochemical industries, hence this work proposes a new type of internal coating in order to avoid fouling and decrease the pressure loss in the flow. For this, we use a composition of vinyl ester resins and manometric loads, which after cleaning and preparation of the internal surface of the tube will be applied through a process of centrifugation, adjusted by a lathe. After curing the resin, a test of roughness will be realized in order to analyze the reduction of friction factor and thus be able to conclude whether there was a significant decrease in pressure drop. With test results in hand, we hope to obtain a coating that meets most of the properties required by the industry and to provide a reduction in operating costs and a visible improvement in the conditions of use of the pipe

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A combinação de polímeros com nanopartículas de metais nobres resultam na formação de filmes finos, que podem ser utilizado na fabricação de nanosensores. Esses filmes finos possuem propriedades exclusivas, que causam ressonância plasmônica de superfície pela mudança conformacional dos mesmos. Essa variação conformacional é causada pela interação com analito ou por estímulo externo, podendo ser analisada por espectroscopia de absorção na região do UV-vis. Este simples e econômico meio de transdução do sinal apresenta-se como uma ferramenta bastante promissora, e se combinado com a alta seletividade encontrada em reações biológicas, torna-se ainda mais promissora no desenvolvimento de sensores. Os esforços desse projeto foram concentrados para o desenvolvimento dos sensores que respondam a estímulos externo e baseado na utilização de polímeros escovas. Este trabalho de conclusão de curso foi baseada na produção de sensores nanoplasmônicos, que na presença de fatores externos causam modificação estrutural dos filmes finos poliméricos depositados sobre um substrato e dão um resposta altamente seletiva. As mudanças conduzirão à geração de sinais ópticos ou eletroquímico, que serão medidos por transmissão de ressonância plasmônica de superfície ou via eletroquímica. Foram realizados experimentos de voltametria cíclica e impedância eletroquímica em pH=3 para avaliar a capacidade de eletródica deste material. Também foram efetuados experimentos por espectrofotometria de absorção na região de ultravioleta-visível em pHs variando de 3 a 7 para se analisar o efeito plasmônico do material. Pode-se notar que em pH mais ácidos o polímero se mostrou mais condutor e de acordo com a literatura este efeito é causado pela expansão polimérica que deixa o mesmo em seu estado ativo ON (expandido). Já em pH mais básicos os polímeros demonstraram um comportamento inverso por os mesmo se contraem, ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As they have excellent mechanical properties, corrosion resistance and biocompatibility, much research has been conducted with respect to biomedical applications of titanium alloys. This work aims to study the experimental system binary alloy Ti-15Mo, in the raw state of fusion and heat treatment after homogenization, solubilization and calcination (simulating conditions employed for nanotube growth) targeting biomedical applications. Samples were obtained by casting the components in an electric arc furnace with inert atmosphere of argon. After obtaining the alloy, it was heat treated at three different heat treatments, namely homogenizing, calcining and simulation solubilization. The phases present were analyzed by X-ray diffraction, optical microscopy and microhardness testing

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho apresenta o estudo de dois sistemas de liberação prolongada, microemulsão e lipossomas, contendo peptídeo regulatório de fatores de crescimento, “osteogenic growth peptide” OGP, para aplicação em regeneração óssea. A base de adsorção para estes sistemas de liberação foi a celulose bacteriana (CB) produzida pela bactéria Gluconacetobacter xylinus. Foi escolhida devido às suas propriedades físicas e químicas, tais como como alta resistência à corrosão química, bio absorção, biocompatibilidade, porosidade e ainda boa resistência mecânica, o que a torna um biopolímero com grande potencial a ser explorado pela ciência biomédica. Estudos in vitro foram realizados para avaliar o perfil de liberação do peptídeo dos diferentes sistemas de liberação prolongada. O peptídeo OGP foi sintetizado pelo método da fase sólida (estratégia SPFS Fmoc); foi purificado e caracterizado por HPLC, espectrometria de massas e análise de aminoácidos e, em seguida, marcados com 5,6 carboxifluoresceína (CF) para análise por espectroscopia de fluorescência. O peptídeo marcado foi incorporado aos sistemas de liberação no momento do respectivo preparo, foram adsorvidos na CB por um período de 72h, seguido de sua liberação prolongada em sistema fechado de fluxo constante contendo tampão PBS pH 7,4, por um período de 24h. Após a análise da liberação, observou se que o sistema que obteve melhor resultado foi a microemulsão, sendo sua liberação prolongada nas primeiras 6,5 h, liberando 21,5% do valor teórico de peptídeo incorporado, seguido de uma liberação constante a partir desse período. Dessa forma, tem se que a microemulsão pode ser um sistema promissor para liberação prolongada do OGP em processos de regeneração óssea