601 resultados para Consultórios odontológicos - Ergonomia
Resumo:
In hospitals, health professionals may face different situations and problems. By following them, it is remarkable that one of the difficulties is related to the support provided by the facilities to carry out their work. This also affects the quality of treatment offered to patients. One of the points of improvement that could be studied is hospital beds. The Fawler's simplest hospital bed type, used in most Brazilian public hospitals, is designed with an ergonomic average height that offers a default position for analysis and treatment of patients. There is no possibility of adjusting the height of those beds, and hence there is a limitation in this regard since that height is fixed, but the physical structures of the workers and patients may vary widely and there may be a conflict when there are people too large or small involved in this process. Beyond that, studies by experts show that beds with height adjustment decreases the muscular effort and improve the movement quality of the spine of nursing staff, reducing the force on certain vertebrae and also the ergonomic risk. Of course, patient comfort is also affected accordingly. As the beds made with height adjustment are very expensive, this study aims to design a device to adapt the not adjustable beds. The project must be viable from an economic and mechanic standpoint, being able to adapt both old and new simplest Fawler hospital bed models, since their dimensions are similar. The final result shows that it is possible to adapt such beds using the designed concept at a viable cost. Furthermore, this concept could be applied in other bed types or objects that have hollow feet
Resumo:
With the popularization of information technology and government incentives for inclusion in the digital era, an important issue for science and for industry is the design of tool s for entrance of input to the device, that is , the peripherals at tached to the computer that are reaching the consumer. In order to minimize the impact of repetitive use of these tools for entry, whether when playing games or working, more studies are in need to developper ipherals that enable comfort and effi ciency. This study examined the per formance of individuals with differents izes of hand (i.e., large and small ) in performance of three task s on the computer us ing mouses of small and large sizes. For thi s study, 19 young adul ts were volunteers and asked to per form activities with greater precision and speed. In addition, al l participants were asked on the use of computers. The results showed no statistically significant differences in the performance related to the size of the mouse between subjects with small and large hands. However, an interest ingresult as observed with respect to the performance of individuals with a large hand to perform tas ks more quickly. The results of this study suggest that with both, the small and the large mouse, individuals with big hands have a fas terper formancein tasks of dragging and clicking when compared with the performance of indi viduals with small hand.
Resumo:
Continuous improvement of industrial processes is one way to become companies more competitive in the market. For this, a fairly widespread use is the methodology of lean production systems, by eliminating waste. One of the tools of these systems is the method of rapid exchange of die or also called SMED, which will be applied in this study. The study aims to develop proposals for reducing the time of set up of two machines in two machining lines, watching also the ergonomics and safety conditions in this operations. The set up time reduction is justified among others, due to increase the machine productivity. In applying the connecting rod machining line, there were two types of exchange. Reductions in time to set up proposals reached values of 47% to one of them, and 55% to the other. It is important to underline that to reach this result, there was no need for large investments. In the application in block machining line, was developed an improvement in the ergonomic area. It was placed a pulley block that came to increase the time of tool change. Aiming to improve the security of the exchange, without productivity loss, the method was applied to reduce this time. It was developed two proposals.: the first would reduce that time by 19%, and does not require many resources of the company. The second involves the parallelization of the exchange, so that the reduction is 48%. However, this proposal requires one more manpower at the time of exchange and it is not always possible
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O Projeto de Extensão foi desenvolvido na Farmácia-Escola Prof. Dr. Antônio Alonso Martinez, que faz parte do NAC (Núcleo de Atendimento à Comunidade), pertencente à Faculdade de Ciências Farmacêuticas da UNESP. Desenvolveu-se um Sistema de Gestão Interno para o controle das amostras grátis e medicamentos que são destinados à doação para a população de Araraquara e região. Realizou-se a orientação e conscientização da população sobre o reaproveitamento de medicamentos e amostras grátis que não seriam mais utilizados e que estavam dentro do prazo de validade. A divulgação foi efetuada com folder explicativo que foi distribuído na Farmácia-Escola, em consultórios médicos e nas faculdades da UNESP do Câmpus de Araraquara. Além disso, houve divulgação na Semana de Atenção Farmacêutica Estudantil (SAFE) e no site e jornal da EPTV. O prazo de validade de cada produto foi verificado e a dispensação desses medicamentos foi feita mediante a apresentação de prescrição médica. Além disso, realizou-se a Assistência Farmacêutica ao informar ao paciente os detalhes da posologia e possíveis interações medicamentosas, de modo a esclarecer eventuais dúvidas dos pacientes. Os medicamentos mais doados foram anti-hipertensivos e hormônios, refletindo no maior número de formas farmacêuticas doadas como sendo comprimidos e cápsulas. O objetivo da divulgação foi alcançado com o aumento de doações realizadas nos meses subsequentes ao início da mesma e com o aumento de 61,9 % em relação ao ano de 2012
Resumo:
Introduction and Objective: Microorganisms are responsible for multiple infections and pathologies; this is why it is important to control microbes that can be found in the triple syringe used for irrigation in different dental procedures. The aim of this study was to identify cultivable species of microbes (fungus and bacteria) found in some dental units water lines of a private dental clinic from Medellín, Colombia. Materials and Methods: Random samples were taken from 11 chairs from a total of 89; a sample of water of 500ml was collected from the triple syringe of each selected chair. The study aim to search for the presence of total coliforms, filamentous fungi and leavened Results: the average presence of microorganisms was between 40CFU and more of 200 CFU. Microorganisms such as Aeromona salmonicida, Actinobacilus sp and Pseudomona maltophil were isolated. No total coliforms neither fecal coliforms were found. Conclusions: the high levels of contamination suggest that there is a mature biofilm in somewhere of the dental unit water line, but the absence of total and fecalis coliforms suggest that the water had been treated.
Resumo:
Nanotechnology, the science of minuscule, has developed products which are able t o manipulate atoms and molecules that could be applied in the sterilization process of dental instruments. Objetives: The objective of the present study was to evaluate the self-cleaning action of TiO2 and Ag nanoparticles coating on dental instruments by the photocataliys process under UV and visible light irradiation. Material and method: Microbiologic tests were done using dental cement spatulas coated with TiO2 and Ag nanoparticles (one or three layers), and contaminated with 10 mcrl of Pseudomonas aeruginosa and Enterococcus faecalis, respectively. After contamination, they were exposed to ultraviolet light and visible light for 120 minutes. Next, they were transferred to and stored in test tubes with BHI (Brain Heart Infusion) and incubated in 35 to 37 °C. Checking times for bacterial growth and for control and retrieval tests were done at: 24, 48, 72 and 96 hours. Result: The Pseudomonas aeruginosa was inactive after 120 minutes of ultraviolet light irradiation, thus confirming the heterogeneous photocatalytic activity of TiO2 and Ag. The Pseudomonas aeruginosa was not inactivated under visible light irradiation and the Enterococcus faecalis was not inactivated under UV and visible light irradiation of the dental cement spatulas coated with TiO2 and Ag nanoparticles in the readings to 96 hours, showing bacterial growth. Conclusion: There were no influence of one or three layers of TiO2 and Ag nanoparticles coating of the spatulas in the results. The heterogeneous photocatalysis activity of TiO2 and Ag under UV light irradiation was confirmed for Pseudomonas aeruginosa but not under visible light. Enterococcus faecalis did not confirmed the photocatalytics activity of TiO2 and Ag under UV light irradiation and visible lights irradiation.
Resumo:
The purpose of this in vitro study was to evaluate the effect of air-abrasion/zirconia sintering order on the yttria partially stabilized tetragonal zirconia polycrystal (Y-TZP) surface characterization (roughness, morphology, and phase transformation), flexural strength (FS), and shear bond strength (SBS) to a resin cement. Y-TZP specimens were air abraded with 50-μm Al2O3 particles after (AS), before (BS), or before and after zirconia sintering (BAS). For roughness (Ra), 30 block specimens (12×12×3.0 mm; n=10) had their surfaces analyzed by a profilometer. Next, on the air-abraded surfaces of these specimens, composite resin discs (n=30) were bonded with RelyX ARC. The bonded specimens were stored for 24 hours in distilled water at 37°C before shear testing. Failure mode was determined with a stereomicroscope (20×). The surface morphology (n=2) was evaluated by SEM (500×). For the four-point flexural strength test (EMIC DL2000), 39 bar-shaped specimens (20×4.0×1.2 mm; n=13) were air abraded according to the three conditions proposed, and an additional group (nonabraded) was evaluated (n=13). The quantitative analysis of phase transformation (n=1) was completed with Rietveld refinement with X-ray diffraction data. Ra (μm) and SBS (MPa) data were analyzed by one-way analysis of variance (ANOVA) and the Tukey test (α=0.05). Pearson correlation analysis was used to determine if there was a correlation between roughness and SBS. For FS (MPa) data, one-way ANOVA and the Dunnett C-test (α=0.05) were used. The air-abrasion/zirconia sintering order influenced significantly (p<0.001) Ra, SBS, and FS. The BS and AS groups presented the highest (1.3 μm) and the lowest (0.7 μm) Ra. The highest SBS (7.0 MPa) was exhibited by the BAS group, followed by the AS group (5.4 MPa) and finally by the BS group (2.6 MPa). All groups presented 100% adhesive failure. A weak correlation (r=−0.45, p<0.05) was found between roughness and SBS. The air-abrasion/zirconia sintering order provided differences in the surface morphology. The nonabraded (926.8 MPa) and BS (816.3 MPa) groups exhibited statistically similar FS values but lower values than the AS (1249.1 MPa) and BAS (1181.4 MPa) groups, with no significant difference between them. The nonabraded, AS, BS, and BAS groups exhibited, respectively, percentages of monoclinic phase of 0.0 wt%, 12.2 wt%, 0.0 wt%, and 8.6 wt%. The rougher surface provided by the air-abrasion before zirconia sintering may have impaired the bonding with the resin cement. The morphological patterns were consistent with the surface roughness. Considering the short-term SBS and FS, the BAS group exhibited the best performance. Air abrasion, regardless of its performance order, provides tetragonal to monoclinic transformation, while sintering tends to zero the monoclinic phase content.
Resumo:
The contemporary implant dentistry is in constant technological development, improving the oral rehabilitation process of partial or totally edentulous patients. On the other hand, anatomical limitations, such as the maxillary sinus and the mandibular canal in the posterior region of the jaws can limit the implant placement. Furthermore, due to the absence of dental elements, alveolar ridge atrophy is frequently observed. This aspect represents a loss either in quantity or quality of the bone tissue available for the dental implant rehabilitation. To make possible the dental implant rehabilitation even in adverse conditions, some solutions have been considered, such as the use of short implants (≤ 10 mm length) and/or small diameter implants (2,8; 3,3 and 3,5 mm width). The aim of this study is to present a literature review considering the use of short implants in oral rehabilitation, presenting the currently view of the matter. Based on the literature review, the use of short implants produced similar clinical success to conventional implants (greater than 10 mm in length). Therefore, its use can be considered a viable alternative, where anatomical limitations are present.
Resumo:
Statement of problem Because zirconia is a glass-free material, alternative surface treatments such as airborne-particle abrasion or silica coating should be used for long-term bonding. However, these surface treatments in combination with different bonding agents and luting cements have not yet been studied. Purpose The purpose of the study was to evaluate the effect of surface treatments on the shear bond strength (SBS) of luting cements to Y-TZP ceramic. Material and methods Zirconia disks (N=240) were airborne-particle abraded with the following particles (n=48): 50 μm Al2O3; 120 μm Al2O3; 30 μm silica-coated Al2O3 (Rocatec Soft); 120 μm Al2O3+110 μm silica-coated Al2O3 (Rocatec Plus); and Rocatec Plus. After silanization of the zirconia surface, composite resin disks were bonded with (n=12) RelyX Luting 2; RelyX ARC; RelyX U100; and Panavia F. The bonded specimens were thermocycled (10 000 cycles) and tested for SBS. Failure mode was determined with a stereomicroscope (×20). The morphology and elemental composition of airborne-particle abraded surfaces were evaluated with scanning electron microscopy (×500) and energy-dispersive x-ray spectroscopy (×50). Results Surface treatments, cements, and their interaction were significant (P<.001). For RelyX ARC, Rocatec Soft and Rocatec Plus provided the highest SBS. In general, surface treatments did not influence the SBS of RelyX U100 and Panavia F. Regardless of the cement, no significant difference was found between 50 μm and 120 μm Al2O3 particles, between Rocatec Soft and Rocatec Plus, or between Rocatec Plus and 120 μm Al2O3 particles+Rocatec Plus. All groups showed adhesive failures. Different particle sizes provided differences in morphological patterns. The elemental composition comprised Al and Al/Si for alumina and silica-abraded zirconia. Conclusions Particle size did not influence the SBS of the groups abraded exclusively with alumina or silica-coated particles. RelyX ARC was more surface-treatment dependent than RelyX U100 or Panavia F.
Resumo:
Introduction: Currently, there are many questions regarding the cleaning methods seeking greater efficiency and less loss of burs. Aim: the aim of this study was to evaluate the influence of cleaning methods on the cutting efficiency and morphological characteristics of stainless steel burs tungsten carbide (carbide). Materials and method: Thirty burs were divided into five groups (n = 5) according with the cleaning method: L1 - steel brush, L2 - nylon brush, L3 - ultrasound + distilled water, L4 - ultrasound + descaling solution and L5 - no cleaning method (control). The burs were used for the cutting of bovine enamel during six periods of 12 minutes each. After each period, the burs were cleaned (except L5 ) following the protocol established for each group. The cutting efficiency was determined by mass loss and morphological characteristics. Result: The average amount of wear after 72 minutes of use were L1 = 0.3558 g; L2 = 0.4275 g; L3 = 0.4652 g; L4 = 0.4396 g e L5 = 0.4854 g; significant differences in the time of use (p < 0.001) and cleaning method (p < 0.001). The L1 group showed the worst performance. Regardless of the experimental group, morphological analysis revealed alterations in the cutting blades soon after the first 12 minutes, being L1 the most affected group. Conclusion: The cleaning with wire brush was the most damaging method to the cutting efficiency and to the morphology of carbide burs.
Resumo:
The aim of this in vitro study was to comparatively evaluate the mesio and distal furcation entrance measurements of first maxillary premolar. The measurements were compared with different curette blades. A caliper was used by an examinator to acquire the measurements of root trunk (TR); 1 mm (D1) and 2 mm (D2) both below the furcation entrance. For this study Gracey, Mini Gracey, Padua Lima (PL) and Goldman Fox 4 curettes (Millenium) were selected. Measurements of DT - total distance of the active blade length, DI - width of the active blade, DM - width of the medium part of the active blade were obtained for the curettes. The measurements were obtained in both the coronary face and in the lateral face. The data TR, D1 and D2 presented normal distribution and were statistically analyzed by paired t-test. Statistically significant differences were found in the mesial root trunk region (TR) of both premolars. The mean of the measurements was greater than the distal. Mean and standard deviation were obtained, and both Gracey and Mini Gracey showed mean measurements compatible with the closer furcation entrance (D1 - 1 mm). Goldman Fox 4 showed adaptation only in the mesial face, and Padua Lima showed no access to any of the faces. Thereby it is concluded that the access of the furcation is narrow (D1). The mesial face of the root trunk (TR) showed mean measurement greater than distal face. Gracey and Mini Gracey curettes demonstrated to be compatible for both faces, mesial and distal of the first maxillary premolars studied.
Interação entre odontologia restauradora e periodontia - parte 1: planejamento e protocolo cirúrgico
Resumo:
Current dental treatments search for alternatives to achieve restablishment of esthetics and function. The increased demand for high esthetic patterns stimulates an interaction between the dental specialties towards a comprehensive treatment in order to solve slinical cases effectively. Knowing the components involved in the dental smile harmony is essential for treatment planning and implementation. It is also important to be aware of the changes that may impair suck harmony and become a patient's complaint. This article addresses a multidisciplinary treatment that involved the integration between Periodontics and Restorative Dentistry. After the surgical-restorative planning, periodontal procedures were performed to obtain an adequate balance between the teeth and soft tiessues.
Resumo:
The development of new dental materials has expanded dental therapeutic modalities ensuring excellence in aesthetic restorative treatments. Thus, the direct restorative procedures have been used in cases of dental reconstruction allowing an effective treatment with a low cost, while preserving healthy tooth structure. However, the clinician must be used to the techniques and the material in order to ensure longevity and success in the direct restorative procedure. The aim of this paper is to descrive, after completion of periodontal surgical procedures, the direct restorative step performed for dental reconstruction and diastema closure. The integration between Restorative Dentistry and periodontics enableb the restoration of a harmonious smile in a conservative manner, ensuring aesthetics and patient stisfaction.