909 resultados para Concentration Phenomena
Resumo:
In this study, a neuro-fuzzy estimator was developed for the estimation of biomass concentration of the microalgae Synechococcus nidulans from initial batch concentrations, aiming to predict daily productivity. Nine replica experiments were performed. The growth was monitored daily through the culture medium optic density and kept constant up to the end of the exponential phase. The network training followed a full 3³ factorial design, in which the factors were the number of days in the entry vector (3,5 and 7 days), number of clusters (10, 30 and 50 clusters) and internal weight softening parameter (Sigma) (0.30, 0.45 and 0.60). These factors were confronted with the sum of the quadratic error in the validations. The validations had 24 (A) and 18 (B) days of culture growth. The validations demonstrated that in long-term experiments (Validation A) the use of a few clusters and high Sigma is necessary. However, in short-term experiments (Validation B), Sigma did not influence the result. The optimum point occurred within 3 days in the entry vector, 10 clusters and 0.60 Sigma and the mean determination coefficient was 0.95. The neuro-fuzzy estimator proved a credible alternative to predict the microalgae growth.
Resumo:
Vegetable oils are the richest dietary sources of vitamin E. Vitamin E determination levels in foods are of great importance to adjust the ingestion of nutrients by the population. The purpose of this paper is to determine the concentration of alpha-tocopherol and gamma-tocopherol in vegetable oils and compare the alpha-tocopherol value to the nutritional requirement of vitamin E. The analysis was performed using High Performance Liquid Chromatography. The values expressed as mg/kg for alpha and gamma-tocopherol were, respectively, 120.3±4.2 and 122.0±7.9 in canola oil; 432.3±86.6 and 92.3±9.5 in sunflower oil; 173.0±82.3 and 259.7±43.8 in corn oil; 71.3±6.4 and 273.3±11.1 in soybean oil. A significant difference was encountered between the alpha-tocopherol concentrations in vegetable oils. Similar results were found for gamma-tocopherol, except for corn and soybean oils. It was concluded that the soybean oil was not considered a source of vitamin E. The canola and corn oils were considered sources, and the sunflower oil was considered an excellent source.
Resumo:
Red wines from different countries have been assessed in order to determine the influence of terroir and grape variety in their concentration of chloride. Chloride analysis was carried out by Laboratório de Bebidas de Origem Vegetal do Espírito Santo (Labeves), using the potentiometric method, in which the dosing is directly applied to the sample with an Ag/AgCl electrode. Data were collected to establish the level of chloride, as presented in the analysis reports issued by Labeves, and to serve as a wine categorization database, according to grape variety and country of origin. Australia and Argentina presented the highest levels of chloride and the wines made from the Syrah variety presented the highest concentration of such ion. We have, therefore, found that terroir and grape variety do have an influence over the concentration of chloride in red wines.
Resumo:
Abstract Bread is one of the most consumed foods in the world, and alternatives have been sought to extend its shell life, and freezing is one of the most popular methods. The purpose of this study was to evaluate the effect of freezing rate and trehalose concentration on the fermentative and viscoelastic properties of dough and bread quality. Dough was prepared and trehalose was added at three concentrations (0, 400, 800 ppm); dough was pre fermented and frozen at two freezing rates then stored for 42 days. Frozen dough samples were thawed every two weeks. CO2 production and elastic and viscous modulus were determined. In addition, bread was elaborated and specific volume and firmness were evaluated. High trehalose concentrations (400 and 800 ppm) produced dough with the best viscoelastic and fermentative properties. Greater bread volume and less firmness were observed when a slow freezing rate (-.14 °C/min) was employed.
Resumo:
The relationship between photoperiod, plasma concentration of ionic calcium and the histology of the prolactin-secreting cells of the rostral pars distalis of the pituitary gland, the Corpuscles of Stannius and the Ultimobranchial gland were investigated. Neither the plasma concentration of ionic calcium nor histologically apparent prolactin cell activity could be correlated with photoperiod. Some evidence of a photoperiodic effect on both the Corpuscles of Stannius and the Ultimobranchial gland was obtained. The expected reciprocal relationship between the activity of these glands was not obvious at the histological level . Quantitative and qualitative analysis at the light microscope level revealed, however, that the hormone prolactin-secreting eta cells of the rostral pars distalis and the hypocalcin-secreting cells of the Corpuscles of Stannius may be arranged in a lamellar pattern comprized of synchronous bands of cells in like-phase of a secretory cycle consisting of four stages - synthesis, storage, release and reorganization. Such synchronized cell cycles in these glands have not heretofore been described in literature. It is suggested that the maintenance of at least 255? of the cells in any one phase of the cycle ensures a supply of the required hormone at all times.
Resumo:
Several automated reversed-phase HPLC methods have been developed to determine trace concentrations of carbamate pesticides (which are of concern in Ontario environmental samples) in water by utilizing two solid sorbent extraction techniques. One of the methods is known as on-line pre-concentration'. This technique involves passing 100 milliliters of sample water through a 3 cm pre-column, packed with 5 micron ODS sorbent, at flow rates varying from 5-10 mUmin. By the use of a valve apparatus, the HPLC system is then switched to a gradient mobile phase program consisting of acetonitrile and water. The analytes, Propoxur, Carbofuran, Carbaryl, Propham, Captan, Chloropropham, Barban, and Butylate, which are pre-concentrated on the pre-column, are eluted and separated on a 25 cm C-8 analytical column and determined by UV absorption at 220 nm. The total analytical time is 60 minutes, and the pre-column can be used repeatedly for the analysis of as many as thirty samples. The method is highly sensitive as 100 percent of the analytes present in the sample can be injected into the HPLC. No breakthrough of any of the analytes was observed and the minimum detectable concentrations range from 10 to 480 ng/L. The developed method is totally automated for the analysis of one sample. When the above mobile phase is modified with a buffer solution, Aminocarb, Benomyl, and its degradation product, MBC, can also be detected along with the above pesticides with baseline resolution for all of the analytes. The method can also be easily modified to determine Benomyl and MBC both as solute and as particulate matter. By using a commercially available solid phase extraction cartridge, in lieu of a pre-column, for the extraction and concentration of analytes, a completely automated method has been developed with the aid of the Waters Millilab Workstation. Sample water is loaded at 10 mL/min through a cartridge and the concentrated analytes are eluted from the sorbent with acetonitrile. The resulting eluate is blown-down under nitrogen, made up to volume with water, and injected into the HPLC. The total analytical time is 90 minutes. Fifty percent of the analytes present in the sample can be injected into the HPLC, and recoveries for the above eight pesticides ranged from 84 to 93 percent. The minimum detectable concentrations range from 20 to 960 ng/L. The developed method is totally automated for the analysis of up to thirty consecutive samples. The method has proven to be applicable to both purer water samples as well as untreated lake water samples.
Resumo:
This work includes two major parts. The first part of the work concentrated on the studies of the application of the highperfonnance liquid chromatography-particle beam interface-mass spectrometry system of some pesticides. Factors that have effects on the detection sensitivity were studied. The linearity ranges and detection limits of ten pesticides are also given in this work. The second part of the work concentrated on the studies of the reduction phenomena of nitro compounds in the HPLC-PB-MS system. Direct probe mass spectrometry and gas chromatography-mass spectrometry techniques were also used in the work. Factors that have effects on the reduction of the nitro compounds were studied, and the possible explanation is proposed. The final part of this work included the studies of reduction behavior of some other compounds in the HPLC-PB-MS system, included in them are: quinones, sulfoxides, and sulfones.
Resumo:
The effects. of moisture, cation concentration, dens ity , temper~ t ure and grai n si ze on the electrical resistivity of so il s are examined using laboratory prepared soils. An i nexpen si ve method for preparing soils of different compositions was developed by mixing various size fractions i n the laboratory. Moisture and cation c oncentration are related to soil resistivity by powe r functions, whereas soil resistiv ity and temperature, density, Yo gravel, sand , sil t, and clay are related by exponential functions . A total of 1066 cases (8528 data) from all the experiments were used in a step-wise multiple linear r egression to determine the effect of each variable on soil resistivity. Six variables out of the eight variables studied account for 92.57/. of the total variance in so il resistivity with a correlation coefficient of 0.96. The other two variables (silt and gravel) did not increase the · variance. Moisture content was found to be - the most important Yo clay. variable- affecting s oil res istivi ty followed by These two variables account for 90.81Yo of the total variance in soil resistivity with a correlation ~oefficient ·.of 0 . 95. Based on these results an equation to ' ~~ed{ ct soil r esist ivi ty using moisture and Yo clay is developed . To t est the predicted equation, resistivity measurements were made on natural soils both in s i tu a nd i n the laboratory. The data show that field and laboratory measurements are comparable. The predicted regression line c losely coinciqes with resistivity data from area A and area B soils ~clayey and silty~clayey sands). Resistivity data and the predicted regression line in the case of c layey soils (clays> 40%) do not coincide, especially a t l ess than 15% moisture. The regression equation overestimates the resistivity of so i l s from area C and underestimates for area D soils. Laboratory prepared high clay soils give similar trends. The deviations are probably caused by heterogeneous distribution of mo i sture and difference in the type o f cl ays present in these soils.
Resumo:
3-alkyl-2-methoxypyrazines (MPs) are grape- and insect-derived odor-active compounds responsible for vegetative percepts that are detrimental to wine quality when elevated. This study tested both the effect of closure/packaging types and light/temperature storage conditions on MPs (isopropyl-, secbutyl-, and isobutyl-MP) in wine. An MP-emiched wine rapidly (after 140 hours) and significantly decreased in MP concentration after natural and synthetic cork contact (immersion of closures in wine). This decrease was greatest with synthetic closures (70% - 89% reduction) and secbutyl-MP. Subsequently storage trials tested the effects of commercial closure/packaging options (natural cork, agglomerate cork, synthetic corks, screwcaps and TetraPak® cartons) on MPs in MP-emiched Riesling and Cabernet Franc over 18 months. Regardless of packaging, isobutyl-MP was the most altered from bottling. Notably, all MP levels tended to decrease to the greatest extent in TetraPak® cartons (~34% for all MPs) and there was evidence of contribution ofisoproyl- and secbutyl-MP from cork-based closures (i.e. ~30% increase in secbutyl-MP after 6 months) or from an unidentified wine constituent. To test the effects of various light/temperature conditions (light exposed at ambient temperature in three different bottle hues, light excluded at ambient temperature and light excluded at a "cellar" temperature (14°C)), MP-emiched Riesling and Cabernet Franc were also analyzed for MP concentrations over 12 months. MPs did not vary consistently with light or temperature. Other odorants and physico-chemical properties were tested in all wines during storage trials and closely agree with previous literature. These results provide novel insights into MPs during ageing, interactions with packaging and storage conditions, and assist in the selection of storage conditions/packaging for optimal wine quality.
Resumo:
UANL
Resumo:
Les microcantileviers fonctionnalisés offrent une plateforme idéale pour la nano- et micro-mécanique et pour le développement de (bio-) capteurs tres sensible. Le principe d’opération consiste dans des évènements physicochimiques qui se passent du côté fonctionnalisé du microcantilevier induisant une différence de stress de surface entre les deux côtés du cantilevier qui cause une déflexion verticale du levier. Par contre, les facteurs et les phénomènes interfacials qui régissent la nature et l'intensité du stress de surface sont encore méconnus. Pour éclaircir ce phénomène, la première partie de cette thèse porte sur l'étude des réactions de microcantileviers qui sont recouverts d'or et fonctionnalisés par une monocouche auto-assemblée (MAA) électroactive. La formation d'une MAA de ferrocènylundécanethiol (FcC11SH) à la surface d'or d'un microcantilevier est le modèle utilisé pour mieux comprendre le stress de surface induit par l’électrochimie. Les résultats obtenus démontrent qu'une transformation rédox de la MAA de FcC11SH crée un stress de surface qui résulte dans une déflexion verticale du microcantilevier. Dépendamment de la flexibilité du microcantilevier, cette déflexion peut varier de quelques nanomètres à quelques micromètres. L’oxydation de cette MAA de FcC11SH dans un environnement d'ions perchlorate génère un changement de stress de surface compressive. Les résultats indiquent que la déflexion du microcantilevier est due à une tension latérale provenant d'une réorientation et d'une expansion moléculaire lors du transfért de charge et de pairage d’anions. Pour vérifier cette hypothèse, les mêmes expériences ont été répéteés avec des microcantileviers qui ont été couverts d'une MAA mixte, où les groupements électroactifs de ferrocène sont isolés par des alkylthiols inactifs. Lorsqu’un potentiel est appliqué, un courant est détecté mais le microcantilevier ne signale aucune déflexion. Ces résultats confirment que la déflexion du microcantilevier est due à une pression latérale provenant du ferrocènium qui se réorganise et qui crée une pression sur ses pairs avoisinants plutôt que du couplage d’anions. L’amplitude de la déflexion verticale du microcantilevier dépend de la structure moléculaire de la MAA et du le type d’anion utilisés lors de la réaction électrochimique. Dans la prochaine partie de la thèse, l’électrochimie et la spectroscopie de résonance de plasmon en surface ont été combinées pour arriver à une description de l’adsorption et de l’agrégation des n-alkyl sulfates à l’interface FcC11SAu/électrolyte. À toutes les concentrations de solution, les molécules d'agent tensio-actif sont empilées perpendiculairement à la surface d'électrode sous forme de monocouche condensé entrecroisé. Cependant, la densité du film spécifiquement adsorbé s'est avérée être affectée par l'état d'organisation des agents tensio-actifs en solution. À faible concentration, où les molécules d'agent tensio-actif sont présentes en tant que monomères solvatés, les monomères peuvent facilement s'adapter à l’évolution de la concentration en surface du ferrocènium lors du balayage du potential. Cependant, lorsque les molécules sont présentes en solution en tant que micelles une densité plus faible d'agent tensio-actif a été trouvée en raison de l'incapacité de répondre effectivement à la surface de ferrocenium générée dynamiquement.
Resumo:
La présente étude porte sur l’évaluation d’une méthode d’acquisition de la solution de sol présente à l’interface sol-racine, dans la rhizosphère. Cette interface constitue le lieu privilégié de prise en charge par les plantes des contaminants, tels que les métaux traces. Comme les plantes acquièrent ces éléments à partir de la phase liquide, la solution de sol de la rhizosphère est une composante clé pour déterminer la fraction de métaux traces biodisponibles. La microlysimétrie est la méthode in situ la plus appropriée pour aborder les difficultés liées à l’échelle microscopique de la rhizosphère. Ainsi, dans les études sur la biodisponibilité des métaux traces au niveau de la rhizosphère, les microlysimètres (Rhizon©) gagnent en popularité sans, toutefois, avoir fait l’objet d’études exhaustives. L’objectif de cette étude est donc d’évaluer la capacité de ces microlysimètres à préserver l’intégrité chimique de la solution, tout en optimisant leur utilisation. Pour ce faire, les microlysimètres ont été soumis à une série d’expériences en présence de solutions et de sols, où la quantité de solution prélevée et le comportement des métaux traces (Cd, Cu, Ni, Pb, Zn) ont été étudiés. Les résultats montrent que les microlysimètres fonctionnent de façon optimale lorsque le contenu en eau du sol est au-dessus de la capacité au champ et lorsqu’il y a peu de matière organique et d’argile. Les sols sableux ayant un faible contenu en C organique reproduisent mieux le volume prélevé et la solution sous la capacité au champ peut être récoltée. L’utilisation des microlysimètres dans ces sols est donc optimale. Dans les essais en solution, les microlysimètres ont atteint un équilibre avec la solution après 10 h de prélèvement. En respectant ce délai et les conditions optimales préalablement établies (pH acide et COD élevé), les microlysimètres préservent la composition chimique de la solution. Dans les essais en sol, cet équilibre n’a pas été atteint après dix jours et huit prélèvements. Le contenu en matière organique et l’activité microbienne semblent responsables de la modification des concentrations en métaux au cours de ces prélèvements, notamment, dans l’horizon FH où les microlysimètres performent très mal. En revanche, dans l’horizon B, les concentrations tendent à se stabiliser vers la fin de la série de prélèvements en se rapprochant des valeurs de référence. Bien que des valeurs plus élevées s’observent pour les microlysimètres, leurs concentrations en métaux sont comparables à celles des méthodes de référence (extrait à l’eau, lysimètres de terrain avec et sans tension). En somme, les microlysimètres se comportent généralement mieux dans l’horizon B. Même si leur utilisation est plus optimale dans un sol sableux, cet horizon est privilégié pour de futures études sur le terrain avec les microlysimètres.