867 resultados para Coated fertilizer
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Eucalyptus plantations have seldom responded to N fertilization in tropical and subtropical regions of Brazil. This implies that rates of N mineralization have been adequate to supply tree needs. However, subsequent crop rotations with low N fertilization may result in declining concentrations of organic and potentially mineralizable N (N-0), and consequent loss of wood productivity. This study investigated (a) in situ N mineralization and N-0 in soils of eucalypt plantations in Sao Paulo state, Brazil; (b) tree growth responses to N fertilizer applied 6-18 months after planting; and (c) the relationships between N-0,N- other soil attributes and tree growth. We established eleven N fertilizer trials (maximum 240 kg ha(-1) of N) in E. grandis and E. grandis x urophylla plantations. The soil types at most sites were Oxisols and Quartzipsamments, with a range of organic matter (18 to 55 g kg(-1)) and clay contents (8% to 67%) in the 0-20 cm layer. Concentrations of N-0 were measured using anaerobic incubation on soil samples collected every three months (different seasons). The samples collected in spring and summer had N-0 140-400 kg ha(-1) (10%-19% total soil N), which were best correlated with soil texture and organic matter content. Rates of in situ net N mineralization (0-20 cm) ranged from 100 to 200 kg ha(-1) year(-1) and were not correlated with clay, total N, or N-0. These high N mineralization rates resulted in a low response to N fertilizer application during the early ages of stand growth, which were highest on sandy soils. At the end of the crop rotation, the response to N fertilizer was negligible and non-significant at all sites.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Natural rubber latex (NRL) is a flexible biomembrane that possesses angiogenic properties and has recently been used for guided bone regeneration, enhancing healing without fibrous tissue, allergies or rejection. Calcium phosphate (Ca/P) ceramics have chemical, biological, and mechanical properties similar to mineral phase of bone, and ability to bond to the host tissue, although it can disperse from where it is applied. Therefore, to create a composite that could enhance the properties of both materials, NRL biomembranes were coated with Ca/P. NRL biomembranes were soaked in 1.5 times concentrated SBF solution for seven days, avoiding the use of high temperatures. SEM showed that Ca/P has been coated in NRL biomembrane, XRD showed low crystallinity and FTIR showed that is the carbonated type B. Furthermore, hemolysis of erythrocytes, quantified spectrophotometrically using materials (Ca/P, NRL, and NRL + Ca/P) showed no hemolytic effects up to 0.125 mg/mL (compounds and mixtures), indicating no detectable disturbance of the red blood cell membranes. The results show that the biomimetic is an appropriate method to coat NRL with Ca/P without using high temperatures, aiming a new biomembrane to improve guided bone regeneration.
Resumo:
PREPARATION OF COATED MICROTOOLS FOR ELECTROCHEMICAL MACHINING APPLICATIONS Ajaya K. Swain, M.S. University of Nebraska, 2010 Advisor: K.P. Rajurkar Coated tools have improved the performance of both traditional and nontraditional machining processes and have resulted in higher material removal, better surface finish, and increased wear resistance. However, a study on the performance of coated tools in micromachining has not yet been adequately conducted. One possible reason is the difficulties associated with the preparation of coated microtools. Besides the technical requirement, economic and environmental aspects of the material and the coating technique used also play a significant role in coating microtools. This, in fact, restricts the range of coating materials and the type of coating process. Handling is another major issue in case of microtools purely because of their miniature size. This research focuses on the preparation of coated microtools for pulse electrochemical machining by electrodeposition. The motivation of this research is derived from the fact that although there were reports of improved machining by using insulating coatings on ECM tools, particularly in ECM drilling operations, not much literature was found relating to use of metallic coating materials in other ECM process types. An ideal ECM tool should be good thermal and electrical conductor, corrosion resistant, electrochemically stable, and stiff enough to withstand electrolyte pressure. Tungsten has almost all the properties desired in an ECM tool material except being electrochemically unstable. Tungsten can be oxidized during machining resulting in poor machining quality. Electrochemical stability of a tungsten ECM tool can be improved by electroplating it with nickel which has superior electrochemical resistance. Moreover, a tungsten tool can be coated in situ reducing the tool handling and breakage frequency. The tungsten microtool was electroplated with nickel with direct and pulse current. The effect of the various input parameters on the coating characteristics was studied and performance of the coated microtool was evaluated in pulse ECM. The coated tool removed more material (about 28%) than the uncoated tool under similar conditions and was more electrochemical stable. It was concluded that nickel coated tungsten microtool can improve the pulse ECM performance.
Resumo:
The hemocompatibility of nanoparticles is of critical importance for their systemic administration as drug delivery systems. Formulations of lipid-core nanocapsules, stabilized with polysorbate 80-lecithin and uncoated or coated with chitosan (LNC and LNC-CS), were prepared and characterized by laser diffraction (D[4,3]: 129 and 134 nm), dynamic light scattering (119 nm and 133 nm), nanoparticle tracking (D50: 124 and 139 nm) and particle mobility (zeta potential: -15.1 mV and + 9.3 mV) analysis. In vitro hemocompatibility studies were carried out with mixtures of nanocapsule suspensions in human blood at 2% and 10% (v/v). The prothrombin time showed no significant change independently of the nanocapsule surface potential or its concentration in plasma. Regarding the activated partial thromboplastin time, both suspensions at 2% (v/v) in plasma did not influence the clotting time. Even though suspensions at 10% (v/v) in plasma decreased the clotting times (p < 0.05), the values were within the normal range. The ability of plasma to activate the coagulation system was maintained after the addition of the formulations. Suspensions at 2% (v/v) in blood showed no significant hemolysis or platelet aggregation. In conclusion, the lipid-core nanocapsules uncoated or coated with chitosan are hemocompatible representing a potential innovative nanotechnological formulation for intravenous administration. (C) 2012 Elsevier B. V. All rights reserved.
Resumo:
In this study we systematically investigated how the solvent composition used for polymer dissolution affects the porous structures of spin-coated polymers films. Cellulose acetate butyrate (CAB) and poly(methylmethacrylate) with low(PMMA-L) and high (PMMA-H) molecular weights were dissolved in mixtures of acetone (AC) and ethyl acetate (EA) at constant polymer concentration of 10 g/L The films were spin-coated at a relative air humidity of 55+/-5%, their thickness and index of refraction were determined by means of ellipsometry and their morphology was analyzed by atomic force microscopy. The dimensions and frequency of nanocavities on polymer films increased with the acetone content (phi(AC)) in the solvent mixture and decreased with increasing polymer molecular weight. Consequently, as the void content increased in the films, their apparent thicknesses increased and their indices of refraction decreased, creating low-cost anti-reflection surface. The void depth was larger for PMMA-L than for CAB. This effect was attributed to different activities of EA and AC in CAB or PMMA-L solution, the larger mobility of chains and the lower polarity of PMMA-L in comparison to CAB. (C) 2012 Elsevier B. V. All rights reserved.
Resumo:
PHYSICO-CHEMICAL EVALUATION OF AN EFFLUENT TREATED IN ANAEROBIC BIODIGESTER REGARDING ITS EFFICIENCE AND APPLICATION AS FERTILIZER. The use of biodigester for basic and environmental sanitation has large demand in Brazil. A biodigester was built to treat conjunctly the human and pig feces and urine, regarding to its future application in rural small towns. The results show that the biodigester can reduce 90% of COD and BOD and, up to 99.99% of thermotolerant coliforms. The treated effluent has variable quantities of macro- and micro-nutrients; and organic matter. However, the concentration variability of the nutrients makes difficult a dosed application into soil. The soluble salts (mainly as Na+ form) make necessary a controlled use to avoid environmental degradation.
Resumo:
An exact expression is derived for the time-averaged electromagnetic energy within a magneto-dielectric coated sphere, which is irradiated by a plane and time-harmonic electromagnetic wave. Both the spherical shell and core are considered to be dispersive and lossy, with a realistic dispersion relation of an isotropic split-ring resonator metamaterial. We obtain analytical expressions for the stored electromagnetic energies inside the core and the shell separately and calculate their contributions to the total average energy density. The stored electromagnetic energy is calculated for two situations involving a metamaterial coated sphere: a dielectric shell and dispersive metamaterial core, and vice versa. An explicit relation between the stored energy and the optical absorption efficiency is also obtained. We show that the stored electromagnetic energy is an observable sensitive to field interferences responsible for the Fano effect. This result, together with the fact that the Fano effect is more likely to occur in metamaterials with negative refraction, suggest that our findings may be explored in applications.