861 resultados para Clinical assessment
Resumo:
Semiquantitative assessment of the knee by expert magnetic resonance imaging readers is a powerful research tool for understanding the natural history of osteoarthritis (OA). Several reliable semiquantitative scoring systems have been applied to large observational cross-sectional and longitudinal epidemiologic studies and interventional clinical trials. Such evaluations have enabled understanding of the relevance of disease in structures within the knee joint to explain pain and progression of OA. Compositional imaging of cartilage has added to our ability to detect early degeneration before morphologic changes are present, which may help to prevent the permanent morphologic changes commonly seen in knee OA.
Resumo:
Speech understanding disorders in the elderly may be due to peripheral or central auditory dysfunctions. Asymmetry of results in dichotic testing increases with age, and may reflect on a lack of inter-hemisphere transmission and cognitive decline. Aim: To investigate auditory processing of aged people with no hearing complaints. Study design: clinical prospective. Materials and Methods: Twenty-two voluntary individuals, aged between 55 and 75 years, were evaluated. They reported no hearing complaints and had maximal auditory thresholds of 40 dB HL until 4 KHz, 80% of minimal speech recognition scores and peripheral symmetry between the ears. We used two kinds of tests: speech in noise and dichotic alternated dissyllables (SSW). Results were compared between males and females, right and left ears and between age groups. Results: There were no significant differences between genders, in both tests. Their Left ears showed worse results, in the competitive condition of SSW. Individuals aged 65 or older had poorer performances than those aged 55 to 64. Conclusion: Central auditory tests showed worse performance with aging. The employment of a dichotic test in the auditory evaluation setting in the elderly may help in the early identification of degenerative processes, which are common among these patients.
Resumo:
Magnetic resonance (MR) imaging is the most important imaging modality for the evaluation of traumatic or degenerative cartilaginous lesions in the knee. It is a powerful noninvasive tool for detecting such lesions and monitoring the effects of pharmacologic and surgical therapy. The specific MR imaging techniques used for these purposes can be divided into two broad categories according to their usefulness for morphologic or compositional evaluation. To assess the structure of knee cartilage, standard spin-echo (SE) and gradient-recalled echo (GRE) sequences, fast SE sequences, and three-dimensional SE and GRE sequences are available. These techniques allow the detection of morphologic defects in the articular cartilage of the knee and are commonly used in research for semiquantitative and quantitative assessments of cartilage. To evaluate the collagen network and proteoglycan content in the knee cartilage matrix, compositional assessment techniques such as T2 mapping, delayed gadolinium-enhanced MR imaging of cartilage (or dGEMRIC), T1 rho imaging, sodium imaging, and diffusion-weighted imaging are available. These techniques may be used in various combinations and at various magnetic field strengths in clinical and research settings to improve the characterization of changes in cartilage. (C)RSNA, 2011 , radiographics.rsna.org
Resumo:
Objective. The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. Study design. The study population consisted of 15 dry human skulls that were submitted to CBCT, and 3-dimensional (3D) images were generated. Linear and angular measurements based on conventional craniometric anatomical landmarks, and were identified in 3D-CBCT images by 2 radiologists twice each independently. Subsequently, physical measurements were made by a third examiner using a digital caliper and a digital goniometer. Results. The results demonstrated no statistically significant difference between inter-and intra-examiner analysis. Regarding accuracy test, no statistically significant differences were found of the comparison between the physical and CBCT-based linear and angular measurements for both examiners (P = .968 and .915, P = .844 and .700, respectively). Conclusions. 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 430-436)
Resumo:
The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 249-257)
Resumo:
Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objectives: To compare the circulating levels of matrix metalloproteinase (MMP)-8, pro-MMP-2, pro-MMP-9, and total MMP-9, their endogenous inhibitors, the tissue inhibitors of metalloproteinases (TIMP)-1 and TIMP-2, and the MMP-8/TIMP-1, MMP-9/TIMP-1, and MMP-2/TIMP-2 ratios in normotensive obese children and adolescents with those found in non obese children and adolescents. Design and methods: We studied 40 obese and 40 non obese (controls) children and adolescents in this cross-sectional study. MMP and TIMP concentrations were measured in plasma samples by gelatin zymography and ELISA. Results: Obese children and adolescents had higher circulating MMP-8 concentrations, lower plasma TIMP-1 concentrations, and higher MMP-8/TIMP-1 ratios than non obese controls (P < 0.05). We found no differences in pro-MMP-9 or total MMP-9 levels, or in MMP-9/TIMP-1 ratios between groups (P > 0.05). While we found no significant differences in pro-MMP-2 levels (P > 0.05) obese Subjects had higher TIMP-2 concentrations and lower pro-MMP-2/TIMP-2 ratios (P < 0.05) than non obese controls. Conclusions: In conclusion, we found evidence indicating higher net MMP-8 (but not MMP-9 and MMP-2) activity in childhood obesity. The increased MMP-8 levels found in obese children suggest a possibly relevant pathophysiological mechanism that may be involved in the increase of cardiovascular risk associated with childhood obesity. (c) 2009 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Resumo:
Objectives. To compare immunohistochemical scoring with clinical scoring and radiology for the assessment of rheumatoid arthritis (RA) disease activity, synovial tissue (ST) biopsied arthroscopically was assessed from 18 patients before and after commencement of disease-modifying anti-rheumatic drug (DMARD) therapy. Methods. Lymphocytes, macrophages, differentiated dendritic cells (DC), vascularity, tumour necrosis factor (TNF)alpha and interleukin-1 beta levels were scored. Clinical status was scored using the American College of Rheumatology (ACR) core set and serial radiographs were scored using the Larsen and Sharp methods. Histopathological evidence of activity included infiltration by lymphocytes, DC, macrophages. tissue vascularity, and expression of lining and sublining TNF alpha. These indices co-varied across the set of ST biopsies and were combined as a synovial activity score for each biopsy. Results. The change in synovial activity with treatment correlated with the ACR clinical response and with decreased radiological progression by the Larsen score, The ACR response to DMARD therapy. the change in synovial activity score and the slowing of radiological progression were each greatest in patients with high initial synovial vascularity. Conclusions. The data demonstrate an association between clinical, radiological and synovial immunopathological responses to anti-rheumatic treatment in RA. High ST vascularity may predict favourable clinical and radiological responses to treatment.
Resumo:
We describe the progress towards developing a patient rated toxicity index that meets all of the patient-important attributes defined by the OMERACT Drug Safety Working Party, These attributes are frequency, severity. importance to patient, importance to the clinician, impact on economics, impact on activities, and integration of adverse effects with benefits. The Stanford Toxicity Index (STI) has been revised to collect all attributes with the exception of impact on activities. However, since the STI is a part of the Health Assessment Questionnaire (HAQ). impact on activities is collected by the HAQ. In particular, a new question asks patients to rate overall satisfaction, taking into consideration both benefits and adverse effects. The nest step in the development of this tool is to ensure that the STI meets the OMERACT filter of truth, discrimination, and feasibility. Although truth and feasibility have been confirmed by comparisons within the ARAMIS database, discrimination needs to be assessed in clinical trials.
Resumo:
There is a surprising lack of published experience on the use of videoconferencing in clinical genetics. Patients were randomly allocated to either a telegenetic (cases) or face-to-face (control) conventional clinic. The telegenetic consultation was done by videoconferencing, using ISDN lines at 384 kbit/s. Evaluation by the doctor and counsellor took place immediately after each appointment. The patient was asked to evaluate the appointment by telephone questionnaire about four weeks after the event. Forty-two patients were invited to participate and 33 (79%) returned their consent forms. Four patients declined to participate and were seen in ordinary face-to-face clinics. Preliminary results showed that the assessment of the telegenetics consultations by doctors, counsellors and patients was very favourable, and they responded positively when asked if they would be happy to use telemedicine in the future. For use in selected consultations, videoconferencing does appear to fulfil a useful role in clinical genetics.
Resumo:
International research has demonstrated significant shortcomings in the health of adults with intellectual disability (ID). Because general practitioners (GPs) are the main providers of primary healthcare for this population, strategies to improve general practice care are an important aspect of rectifying these shortcomings. The present pilot study aimed to determine the effect of various interventions on health maintenance activities and to assess their acceptability to GPs, with a view to informing larger scale studies. The GPs were recruited through an earlier questionnaire-based postal survey. The GPs identified all their adult patients with ID, then obtained consent for participation from three patients randomly selected by the investigators. The GPs completed two self-evaluation forms and case note audits 12 months apart, read a synopsis of the relevant literature provided by the researchers, and completed a comprehensive health assessment (CHA) of their three patients. Forty-five GPs agreed to participate in the CHA programme (CHAP), and 15 completed the project. Thirty-eight patients completed the project. The number of patient-GP dyads who completed the project was too small to demonstrate statistically significant changes in health issues over time. The GPs found that the synopsis of the literature was the best intervention for increasing knowledge and was also the most practical to use in general practice. The CHAP was the intervention that prompted the most action from the GP which would not have been undertaken otherwise. The CHAP appeared to provide a superior review process compared to the other interventions used in the present study. The numbers of health maintenance activities found to be overdue and the number of health issues detected as a result of the process were considerable. The CHAP served as a communication tool and an educative instrument, providing a basis for future studies and strategies to improve the general practice care of adults with ID.
Resumo:
Two hazard risk assessment matrices for the ranking of occupational health risks are described. The qualitative matrix uses qualitative measures of probability and consequence to determine risk assessment codes for hazard-disease combinations. A walk-through survey of an underground metalliferous mine and concentrator is used to demonstrate how the qualitative matrix can be applied to determine priorities for the control of occupational health hazards. The semi-quantitative matrix uses attributable risk as a quantitative measure of probability and uses qualitative measures of consequence. A practical application of this matrix is the determination of occupational health priorities using existing epidemiological studies. Calculated attributable risks from epidemiological studies of hazard-disease combinations in mining and minerals processing are used as examples. These historic response data do not reflect the risks associated with current exposures. A method using current exposure data, known exposure-response relationships and the semi-quantitative matrix is proposed for more accurate and current risk rankings.
Resumo:
Objective: To develop a reliable, valid, and responsive self-administered questionnaire to probe pain, stiffness and physical disability in patients with osteoarthritis (OA) of the hand. Design: In order to assess the dimensionality of the symptomatology of hand OA, a self-administered questionnaire was developed to probe various aspects of pain (10 items), stiffness (two items), and physical function (83 items). The question inventory was generated from eight existing health status measures and an interactive process involving four rheumatologists, two physiotherapists, and an orthopaedic surgeon. Results: Face-to-face interviews were conducted with 50 OA hand patients; 39 females and 11 males with mean age 62.8 years and mean disease duration 9.4 years. Items retained were those which fulfilled specified selection criteria: prevalence greater than or equal to60% and mean importance score approximating or exceeding 2.0 Item exclusion criteria included low prevalence, gender-based, ambiguous, duplicates or similarities, alternatives, composite items, and items that were too restrictive. This process resulted in five pain, one stiffness and nine function items which have been proposed for incorporation in the AUSCAN Index. Conclusions: Using a traditional development strategy, we have constructed a self-administered multi-dimensional outcome measure for assessing hand OA. The next stage includes reliability, validity and responsiveness testing of the 15-item questionnaire. (C) 2002 OsteoArthritis Research Society Intenational. Published by Elsevier Science Ltd. All rights reserved.
Resumo:
Background: The Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index is a previously described self-administered questionnaire covering three domains: pain, stiffness and function. It has been validated in patients with osteoarthritis (OA) of the hip or knee in a paper-based format. Aim: To validate the WOMAC 3.0 using a numerical rating scale in a computerized touch screen format allowing immediate evaluation of the questionnaire. In the computed version cartoons, written and audio instruments were included in order facilitate application. Methods: Fifty patients, demographically balanced, with radiographically proven primary hip or knee OA completed the classical paper and the new computerized WOMAC version. Subjects were randomized either to paper format or computerized format first to balance possible order effects, Results: The intra-class correlation coefficients for pain, stiffness and function values were 0.915, 0.745 and 0.940, respectively. The Spearman correlation coefficients for pain, stiffness and function were 0.88, 0.77 and 0.87, respectively. Conclusion: These data indicate that the computerized WOMAC OA index 3.0 is comparable to the paper WOMAC in all three dimensions. The computerized version would allow physicians to get an immediate result and if present a direct comparison with a previous exam. (C) 2002 OsteoArthritis Research Society International. Published by Elsevier Science Ltd. All rights reserved.
Resumo:
The aim of this study was to develop and trial a method to monitor the evolution of clinical reasoning in a PBL curriculum that is suitable for use in a large medical school. Termed Clinical Reasoning Problems (CRPs), it is based on the notion that clinical reasoning is dependent on the identification and correct interpretation of certain critical clinical features. Each problem consists of a clinical scenario comprising presentation, history and physical examination. Based on this information, subjects are asked to nominate the two most likely diagnoses and to list the clinical features that they considered in formulating their diagnoses, indicating whether these features supported or opposed the nominated diagnoses. Students at different levels of medical training completed a set of 10 CRPs as well as the Diagnostic Thinking Inventory, a self-reporting questionnaire designed to assess reasoning style. Responses were scored against those of a reference group of general practitioners. Results indicate that the CRPs are an easily administered, reliable and valid assessment of clinical reasoning, able to successfully monitor its development throughout medical training. Consequently, they can be employed to assess clinical reasoning skill in individual students and to evaluate the success of undergraduate medical schools in providing effective tuition in clinical reasoning.