877 resultados para Cervical spine
Resumo:
[EN] Background: Cervical cancer is treated mainly by surgery and radiotherapy. Toxicity due to radiation is a limiting factor for treatment success. Determination of lymphocyte radiosensitivity by radio-induced apoptosis arises as a possible method for predictive test development. The aim of this study was to analyze radio-induced apoptosis of peripheral blood lymphocytes. Methods: Ninety four consecutive patients suffering from cervical carcinoma, diagnosed and treated in our institution, and four healthy controls were included in the study. Toxicity was evaluated using the Lent-Soma scale. Peripheral blood lymphocytes were isolated and irradiated at 0, 1, 2 and 8 Gy during 24, 48 and 72 hours. Apoptosis was measured by flow cytometry using annexin V/propidium iodide to determine early and late apoptosis. Lymphocytes were marked with CD45 APC-conjugated monoclonal antibody. Results: Radiation-induced apoptosis (RIA) increased with radiation dose and time of incubation. Data strongly fitted to a semi logarithmic model as follows: RIA = βln(Gy) + α. This mathematical model was defined by two constants: α, is the origin of the curve in the Y axis and determines the percentage of spontaneous cell death and β, is the slope of the curve and determines the percentage of cell death induced at a determined radiation dose (β = ΔRIA/Δln(Gy)). Higher β values (increased rate of RIA at given radiation doses) were observed in patients with low sexual toxicity (Exp(B) = 0.83, C.I. 95% (0.73-0.95), p = 0.007; Exp(B) = 0.88, C.I. 95% (0.82-0.94), p = 0.001; Exp(B) = 0.93, C.I. 95% (0.88-0.99), p = 0.026 for 24, 48 and 72 hours respectively). This relation was also found with rectal (Exp(B) = 0.89, C.I. 95% (0.81-0.98), p = 0.026; Exp(B) = 0.95, C.I. 95% (0.91-0.98), p = 0.013 for 48 and 72 hours respectively) and urinary (Exp(B) = 0.83, C.I. 95% (0.71-0.97), p = 0.021 for 24 hours) toxicity. Conclusion: Radiation induced apoptosis at different time points and radiation doses fitted to a semi logarithmic model defined by a mathematical equation that gives an individual value of radiosensitivity and could predict late toxicity due to radiotherapy. Other prospective studies with higher number of patients are needed to validate these results.
Resumo:
The Swiss Federal Office of Public Health demanded a nationwide health technology assessment registry for cervical and lumbar total disc arthroplasty and for balloon kyphoplasty (BKP) to make a decision about reimbursement of these interventions.
Resumo:
BACKGROUND: Mechanical pain sensitivity is assessed in every patient with pain, either by palpation or by quantitative pressure algometry. Despite widespread use, no studies have formally addressed the usefulness of this practice for the identification of the source of pain. We tested the hypothesis that assessing mechanical pain sensitivity distinguishes damaged from healthy cervical zygapophysial (facet) joints. METHODS: Thirty-three patients with chronic unilateral neck pain were studied. Pressure pain thresholds (PPTs) were assessed bilaterally at all cervical zygapophysial joints. The diagnosis of zygapophysial joint pain was made by selective nerve blocks. Primary analysis was the comparison of the PPT between symptomatic and contralateral asymptomatic joints. The secondary end points were as follows: differences in PPT between affected and asymptomatic joints of the same side of patients with zygapophysial joint pain; differences in PPT at the painful side between patients with and without zygapophysial joint pain; and sensitivity and specificity of PPT for 2 different cutoffs (difference in PPT between affected and contralateral side by 1 and 30 kPa, meaning that the test was considered positive if the difference in PPT between painful and contralateral side was negative by at least 1 and 30 kPa, respectively). The PPT of patients was also compared with the PPT of 12 pain-free subjects. RESULTS: Zygapophysial joint pain was present in 14 patients. In these cases, the difference in mean PPT between affected and contralateral side (primary analysis) was −6.2 kPa (95% confidence interval: −19.5 to 7.2, P = 0.34). In addition, the secondary analyses yielded no statistically significant differences. For the cutoff of 1 kPa, sensitivity and specificity of PPT were 67% and 16%, respectively, resulting in a positive likelihood ratio of 0.79 and a diagnostic confidence of 38%. When the cutoff of 30 kPa was considered, the sensitivity decreased to only 13%, whereas the specificity increased to 95%, resulting in a positive likelihood ratio of 2.53 and a diagnostic confidence of 67%. The PPT was significantly lower in patients than in pain-free subjects (P < 0.001). CONCLUSIONS: Assessing mechanical pain sensitivity is not diagnostic for cervical zygapophysial joint pain. The finding should stimulate further research into a diagnostic tool that is widely used in the clinical examination of patients with pain.